Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Study and evaluation of impulse mass spectrometers for ion analysis in the D and E regions of the ionosphere

Theoretical and numerical analyses were made of planar, cylindrical and spherical electrode time-of-flight mass spectrometers in order to optimize their operating conditions. A numerical analysis of potential barrier gating in time-of-flight spectrometers was also made. The results were used in the design of several small mass spectrometers. These were constructed and tested in a laboratory space simulator. Detailed experimental studies of a miniature cylindrical electrode time of flight mass spectrometer and of a miniature hemispherical electrode time of flight mass spectrometer were made. The extremely high sensitivity of these instruments and their ability to operate at D region pressures with an open source make them ideal instruments for D region ion composition measurements.

Kendall, B. R.↗

A core handling device for the Mars Sample Return Mission

A core handling device for use on Mars is being designed. To provide a context for the design study, it was assumed that a Mars Rover/Sample Return (MRSR) Mission would have the following characteristics: a year or more in length; visits by the rover to 50 or more sites; 100 or more meter-long cores being drilled by the rover; and the capability of returning about 5 kg of Mars regolith to Earth. These characteristics lead to the belief that in order to bring back a variegated set of samples that can address the range of scientific objetives for a MRSR mission to Mars there needs to be considerable analysis done on board the rover. Furthermore, the discrepancy between the amount of sample gathered and the amount to be returned suggests that there needs to be some method of choosing the optimal set of samples. This type of analysis will require pristine material-unaltered by the drilling process. Since the core drill thermally and mechanically alters the outer diameter (about 10 pct) of the core sample, this outer area cannot be used. The primary function of the core handling device is to extract subsamples from the core and to position these subsamples, and the core itself if needed, with respect to the various analytical instruments that can be used to perform these analyses.

Gwynne, Owen↗

Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing

A set of automated planning algorithms is the current operations baseline approach for the Intelligent Payload Module (IPM) of the proposed Hyper spectral Infrared Imager (HyspIRI) mission. For this operations concept, there are only local (e.g. non-depletable) operations constraints, such as real-time downlink and onboard memory, and the forward sweeping algorithm is optimal for determining which science products should be generated onboard and on ground based on geographical overflights, science priorities, alerts, requests, and onboard and ground processing constraints. This automated planning approach was developed for the HyspIRI IPM concept. The HyspIRI IPM is proposed to use an X-band Direct Broadcast (DB) capability that would enable data to be delivered to ground stations virtually as it is acquired. However, the HyspIRI VSWIR and TIR instruments will produce approximately 1 Gbps data, while the DB capability is 15 Mbps for a approx. =60X oversubscription. In order to address this mismatch, this innovation determines which data to downlink based on both the type of surface the spacecraft is overflying, and the onboard processing of data to detect events. For example, when the spacecraft is overflying Polar Regions, it might downlink a snow/ice product. Additionally, the onboard software will search for thermal signatures indicative of a volcanic event or wild fire and downlink summary information (extent, spectra) when detected, thereby reducing data volume. The planning system described above automatically generated the IPM mission plan based on requested products, the overflight regions, and available resources.

Chien, Steve A.↗

Use Of EOS-AURA Observation In The MERRA-2 Reanalysis

Meteorological reanalyses provide multi-year gridded datasets that describe the evolution of the atmosphere. Such products use a data assimilation system, comprising of an atmospheric model, a broad suite of observations, and an analysis system that optimally combines the model forecast with the observations, using an algorithm that includes information about model and data accuracy. The mixture of observations is of central importance to the quality of the assimilated datasets. The Modern-era Retrospective Analysis for Research and Applications (MERRA) included constraints on the thermal structure of the middle atmosphere from nadir sounders on the NOAA polar-orbiting platforms (Stratospheric Sounding Units and Advanced Microwave Sounding Units). These instruments have peak sensitivities that occur well below the stratopause. As such, the radiance measurements do not provide strong constraints on stratopause temperature. The new MERRA-2 reanalysis is using EOS-MLS temperature retrievals after they are available: it will be demonstrated that these data lead to a more realistic stratopause structure in MERRA-2 than in MERRA. Similarly, the work demonstrates the improvements in lower stratospheric ozone in MERRA-2 than in MERRA, for the period when EOS-MLS ozone data are assimilated. This improvement occurs because of the ozone profile information offered by MLS in the low stratosphere, in contrast to the SBUV/2 data used for the rest of MERRA-2. The impacts of choosing to use the EOS-MLS datasets are discussed in context of the continuity of the data record in MERRA- 2.

Meteorological↗

Solar Array (Radiated/Non-Radiated): Materials Characterization and Cryogenic Thermal Cycling Qualification for the Planned Europa Clipper Mission (ECM)

Two special instruments were custom built for our critical study and manufactured and employed to test the SA materials of interest to cryogenic temperature conditions. We have procured custom manufactured two independent systems such as Thermo -Mechanical Analyzer (TMA) with Three Point Bend Probe (TPBP) module and Dilatometer. TMA can be used to measure Young’ s modulus or elastic modulus (e -modulus). Dilatometer can be used to measure Co -efficient of Thermal Expansion (CTE). We have optimized the materials configuration to measure physical properties of radiated and non -radiated materials for CTE and e -modulus, which will be useful to assess materials and processes reliability for cryogenic temperature applications. We have successfully implemented for some materials that are of interest to solar panels for the planned ECM project to measure CTE and Young's modulus. Also a separate study was undertaken to thermal cycle qualify SAs for ECM project. One can do thermal cycling to temperatures of 50 K and 133 K using liquid Helium (Lq He). This is in reality exorbitantly too expensive and is also inefficient. Furthermore, this is not technically controllable test to 133 K and 50 K temperatures. This is also too expensive to accomplish. Therefore, a vacuum set -up was made along with a cryostat successfully. This is a closed loop system where we do not lose the Helium gas. We were able to get to 35 K for a given test coupon size. These temperatures are lower than what we would intend to qualify the solar array technologies. This will allow to have some margin at cold temperatures. We successfully completed the qualification of solar array technologies down to 50 K temperatures. This is the first time we are reporting this accomplishment. In this paper, we will present the solar array materials properties for cryogenic temperatures down to 20 K temperatures and the thermal cycling qualification test results from 133 K to 50 K for three times the mission life of 120 thermal cycles to meet JPL Design.

Ramesham, Rajeshuni↗

Assessing the Altimetric Measurement from CYGNSS Data

The Cyclone Global Navigation Satellite System (CYGNSS) mission was designed to study hurricane intensification by measuring wind speeds in tropical cyclones. However, the delay-Doppler maps (DDM) that are produced can be used to estimate the sea surface height (SSH) at the specular reflection point on the ocean surface. Proofof-concept studies that DDMs are suitable to solve for SSH have been recently reported (Clarizia et al., 2016; Mashburn et al., 2018), based on data acquired by the demonstration satellite experiment Tech Demo Sat - 1 (TDS-1) carrying a GNSS-R receiver similar to the ones onboard CYGNSS. Although the precision of each 1sec averaged SSH is considerably lower than that of the existing satellite altimeters, by virtue of the dense coverage and frequent revisit time exhibited by the constellation of 8 microsats, the error may be smoothed down considerably by optimal interpolation (Li et al., 2016). Hence the CYGNSS dataset presents a potential opportunity to sample the tropical oceans, and investigate the sensitivity of the SSH measurements to mesoscale eddies. Our objective is to analyze the CYGNSS data and test a suite of retrieval algorithms, including that of Mashburn et al., 2018 to obtain SSH, to understand the error sources and possible corrections when available. Because of the limited antenna gain of the CYGNSS instrument, the power SNR for general wind conditions is expected to be too low to accurately track the reflection point contribution, resulting in altimetry errors of the order of several meters. Other significant error sources are the CYGNSS satellites orbit knowledge, the ionosphere, the troposphere, the mean sea surface and the tides; some of these errors can be reduced by using models. The corrected SSH data will be assimilated into the ROMS high-resolution ocean model to investigate their ability to reproduce mesoscale eddies in the tropical oceans.

Voronovich, Alexander↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying the secondary electron cutoff in ultraviolet photoemission spectra for work function measurements of non-ideal surfaces

Abstract Absolute values of work functions can be determined in ultraviolet photoemission spectroscopy (UPS) by measuring the minimum kinetic energy of secondary electrons generated by a known photon energy. However, some samples can produce spectra that are difficult to interpret due to additional intensity below the true secondary electron cutoff. Disordered absorbates on elemental metals add small intensity below the onset for the transition metal surfaces studied, which can be attributed to energy losses after photoelectrons are generated. In contrast, spectra from WO 3−x films can produce multiple onsets with comparable intensity which do not fit this model. False onsets (in the context of work function measurements) can be minimized by optimizing experimental detection parameters including limiting analyzer acceptance angles and pass energy. True work functions can be identified by examining the onsets as the sample bias is varied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimal deformation procedure for hybrid adaptive x-ray mirror based on mechanical and piezo-driven bending system

Here, a hybrid deformable x-ray mirror consisting of a mechanical bender and a bimorph deformable mirror has been developed to realize adaptive optical systems, such as zoom condenser optics, for synchrotron-radiation-based x-ray microscopy. In the developed system, both bending mechanisms comprehensively contribute to the formation of the target mirror shape and can narrow the role of piezoelectric actuators, thereby enabling a more stable operation. In this study, the behavior of the bimorph mirror under the clamped condition was investigated, and the sharing of the deformation amount for each bending mechanism was optimized to minimize the amplitude of the voltage distribution of the bimorph mirror.

47 OTHER INSTRUMENTATION↗

6000 lines/mm blazed grating for a high-resolution x-ray spectrometer

We have designed and fabricated a high groove density blazed grating for a Resonant Inelastic X-ray Scattering spectrometer for the new Qerlin beamline at the Advanced Light Source (ALS) synchrotron facility. The gratings were fabricated using a set of nanofabrication techniques including e-beam lithography, nanoimprint, plasma etch, and anisotropic wet etching. Two gratings with groove density of 6000 lines/mm and 3000 lines/mm and optimized for operation in the 1st and 2nd negative diffraction order respectively were fabricated and tested. We report on fabrication details and characterization of the gratings at beamline 6.3.2 of the ALS.

36 MATERIALS SCIENCE↗

Randomly Sampled-Data Control Systems

The purpose is to solve the Linear Quadratic Regulator (LQR) problem with random time sampling. Such a sampling scheme may arise from imperfect instrumentation as in the case of sampling jitter. It can also model the stochastic information exchange among decentralized controllers to name just a few. A practical suboptimal controller is proposed with the nice property of mean square stability. The proposed controller is suboptimal in the sense that the control structure is limited to be linear. Because of i. i. d. assumption, this does not seem unreasonable. Once the control structure is fixed, the stochastic discrete optimal control problem is transformed into an equivalent deterministic optimal control problem with dynamics described by the matrix difference equation. The N-horizon control problem is solved using the Lagrange's multiplier method. The infinite horizon control problem is formulated as a classical minimization problem. Assuming existence of solution to the minimization problem, the total system is shown to be mean square stable under certain observability conditions. Computer simulations are performed to illustrate these conditions.

Han, Kuoruey↗

High-throughput feedback-enabled optogenetic stimulation and spectroscopy in microwell plates

Abstract The ability to perform sophisticated, high-throughput optogenetic experiments has been greatly enhanced by recent open-source illumination devices that allow independent programming of light patterns in single wells of microwell plates. However, there is currently a lack of instrumentation to monitor such experiments in real time, necessitating repeated transfers of the samples to stand-alone analytical instruments, thus limiting the types of experiments that could be performed. Here we address this gap with the development of the optoPlateReader (oPR), an open-source, solid-state, compact device that allows automated optogenetic stimulation and spectroscopy in each well of a 96-well plate. The oPR integrates an optoPlate illumination module with a module called the optoReader, an array of 96 photodiodes and LEDs that allows 96 parallel light measurements. The oPR was optimized for stimulation with blue light and for measurements of optical density and fluorescence. After calibration of all device components, we used the oPR to measure growth and to induce and measure fluorescent protein expression in E. coli . We further demonstrated how the optical read/write capabilities of the oPR permit computer-in-the-loop feedback control, where the current state of the sample can be used to adjust the optical stimulation parameters of the sample according to pre-defined feedback algorithms. The oPR will thus help realize an untapped potential for optogenetic experiments by enabling automated reading, writing, and feedback in microwell plates through open-source hardware that is accessible, customizable, and inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗

Automatic Generation of Algorithms for High-Speed Reliable Lossy Data Compression (Final Report)

Fast reliable data compression is urgently needed for many leading-edge scientific instruments and for exascale high-performance computing applications because they produce vast amounts of data at extremely high rates. The goal of this project has been to develop a framework named LC that is able to automatically generate high-speed lossless and reliable lossy compression and decompression algorithms that can be customized for different kinds of data. The resulting LC framework is freely available on GitHub. To achieve high-speed operation, LC outputs optimized and parallelized CPU and GPU implementations of the generated algorithms. To ensure the quality of lossily compressed data, LC guarantees the user-provided error bound. To be able to customize the compression algorithm to various use cases, LC can synthesize millions of different algorithms and automatically search for the one that works best for the given data. We have already employed LC to create state-of-the-art lossless and lossy compressors for scientific data as well as leading lossless compressors for images. We hope that LC and the customized, fast, reliable, and CPU/GPU-compatible compression algorithms that it can generate will greatly benefit the many scientific applications that need not only high trustworthiness but also high performance.

97 MATHEMATICS AND COMPUTING↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

H Ly-alpha transmittance of thin foils of C, Si/C, and Al/C for keV particle detectors

A class of instruments designed for remote sensing of space plasmas by measuring energetic neutral atoms (ENA) uses a thin foil as both a signal generator and a light shield. An ENA imager must look directly at the ENA source region, which is also usually an intense source of H Ly-alpha (1216 A) photons. It is desirable to minimize the energy threshold for ENA detectors, at the same time maximizing the blocking of H Ly-alpha. Optimizing filter design to meet these two contrary requirements has led us to measure the transmittance of thin C, Si/C, and Al/C foils at H Ly-alpha. Our results indicate that (1) transmittance of less than 0.0007 can be achieved with 7 micro-g/sq cm Si on 1.7 micro-g/sq cm C; (2) an Si/C composite foil with a thin carbon layer is more effective in blocking UV radiation while having the lowest energy threshold of all the foils measured; and (3) transmittance of Si/C foils of known Si and C thicknesses cannot be accurately predicted, but must be measured.

Drake, V. A.↗

PACE Microphysical Aerosol Properties from Polarimetry (PACE-MAPP)

We present the Plankton, Aerosols, Clouds and Ecosystems Microphysical Aerosol Properties from Polarimetry (PACE-MAPP) polarimetric remote sensing algorithm developed for the newly launched NASA PACE satellite observing system. The objective of PACE-MAPP is to retrieve detailed fine-mode (marine, pollution and smoke) and coarse-mode (sea-salt and dust) aerosol properties over the ocean for a range of light to heavy aerosol loadings using PACE’s polarimetric-imaging capabilities at multiple angles and wavelengths from the ultraviolet (UV) to the near-infrared (NIR). An additional objective for PACE-MAPP is to discriminate aerosols from thin clouds. The PACE-MAPP polarimetric remote sensing retrieval algorithm uses coupled atmosphere-ocean vector radiative transfer, optimal estimation, artificial intelligence and powerful inherent optical property look-up-tables for the Earth’s aerosol, cloud, and hydrosol particles. PACE-MAPP is the only retrieval algorithm designed to invert aerosol/ocean products using both polarimeters onboard PACE. We present results using PACE-MAPP to retrieve aerosol and ocean remote sensing products from measurements by the Hyper-Angular Rainbow Polarimeter #2 (HARP2) and Spectro-polarimeter for Planetary Exploration one (SPEXone) polarimeter instruments onboard PACE.

Snorre Stamnes↗

Advanced Fuels Campaign Execution Plan

The Advanced Fuels Campaign (AFC) Execution Plan outlines the strategy, mission, scope, near-term and long-term goals, structure, and organization associated with nuclear fuels and materials research, development, and demonstration activities within the Department of Energy’s (DOE) Nuclear Fuel Cycle and Supply Chain (NFCSC) program. NFCSC has been given responsibility to identify and mature advanced fuel technologies for the DOE using a science-based approach, focused on developing a fundamental understanding of nuclear fuels and materials to drive development of integrated nuclear fuel and materials technology. This science-based approach combines theory, experiments, and multiscale modeling and simulation to achieve a predictive understanding of relevant behaviors ranging from fuel fabrication processes (and their resulting fuel microstructures) through fuel/cladding performance under irradiation (in contrast to more empirical, observation-based approaches frequently used in fuel performance modeling and fuel qualification). The traditional scope of AFC includes the evaluation and development of multiple fuel forms to support two fuel cycle options: once-through and full recycle. The word “fuel” is used generically to include conventional fuels, transmutation targets, and any associated cladding or duct materials. The once-through fuel cycle addresses advanced light water reactor fuels with enhanced performance, extended burnup, and reduced waste generation. In fiscal year (FY) 2012, AFC’s scope expanded to include research, development, and demonstration (RD&D) for light water reactor (LWR) fuels with enhanced accident tolerance. Fuel fabrication activities include the development of innovative methods to enhance process efficiencies, reduce waste, and improve control over as-fabricated fuel microstructural properties to achieve desired in-reactor performance. Using modern modeling and simulation approaches, the objective is to predict fresh fuel properties given the feedstock characteristics and fabrication process parameters. The performance-related activities include small-scale, in-reactor, and out-of-reactor phenomenological testing (distinct from, but synergistic with, integral prototypic testing) and extensive, quantitative characterization (focusing on characterization of fuel and cladding materials at the scale of microstructure) both before and after testing. Larger-scale, prototypic experiments are conducted in concert with phenomenological testing to drive a Fuel Development and Qualification program, incorporating a fundamental understanding of fuel behavior performance characteristics. Then, using the tools developed under the productive science-based approach, fuels will be optimized to meet specific performance requirements, thereby minimizing the need to repeatedly perform large-scale, integral experiments over a wide parametric range as a means of experimental exploration. Two significant initiatives are underway within AFC. First, a gap analysis completed in early FY 2019 identified critical irradiation testing needs that are lacking within the national light water reactor (LWR) fuels testbed since the shutdown of the Halden Reactor in 2018. The identified gaps are for instrumented, prototypic testing of LWR fuels, especially under boiling water reactor conditions, ramp conditions, and conditions leading to fuel failure; these needs exist for supporting current LWR fuels and their possible extension to higher burnups, but are especially urgent relative to near-term development and qualification of accident-tolerant fuels. Recommendations that resulted from the Halden Gap Analysis focused on enhancements at Advanced Test Reactor (ATR) and Transient Reactor Test Facility (TREAT) to fill gaps in testing capabilities relative to these needs. Second, a concerted effort to develop and demonstrate a systematic approach to accelerating the development, testing, and qualification of new fuel systems has been initiated. This is highlighted by a test strategy that combines the considerable advances in multiscale, mechanistic fuel modeling of recent years with a MiniFuel separate effects test program in the High Flux Isotope Reactor (HFIR) and a Fission Accelerated Steady-state Testing (FAST) semi-integral accelerated test program in ATR. This approach is being tested/demonstrated using the metallic fuel system, but if successful it is expected to be extensible to multiple fuel types and diverse applications. This document includes an overview of the NFCSC program, a definition of science-based development of nuclear fuels, near-term goals for Advanced LWR fuels (ALFs), and longer-term goals for Advanced Reactor Fuels (ARFs) RD&D. This includes the activities that will be conducted to achieve success toward the grand challenge, as well as the goals and milestones to be achieved over the next few decades of research and development. Long-term goals are based on the DOE Office of Nuclear Energ

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗