Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Chandra Serendipitous and Cycle 1 Targeted Surveys

A team led by scientists at the Chandra X-ray Center (CXC, formally known as the AXAF Science Center) is developing plans for a Serendipitous Survey using a selected subset of Chandra observations starting with Cycle 1. This survey will include two parts: (1) for sources sufficiently bright to be identified in available sky surveys (V approximately < 21), probable optical identifications and related imaging data will be, provided with the X-ray data as part of the Chandra data products. (2) at fainter flux X-ray source identifications will be determined from publically available, archival data and new optical imaging observations. We estimate that this survey will yield approximately 2500 source identifications in Cycle 1 down to X-ray flux levels approximately 10(exp -15) erg/sq cm.s and covering an area of sky approximately 10 sq degs. Optical spectroscopy and radio imaging will also be obtained for a subset of these sources. We are exploring appropriate ways to involve interested Chandra observers as well as other scientists in this survey project. A general overview of the various surveys which comprise a portion of the Chandra Cycle 1 GTO and GO programs and are not covered elsewhere in these proceedings will also be presented.

Wilkes, Belinda↗

Joint Strong and Weak Lensing Analysis of the Massive Cluster Field J0850+3604

In this work, we present a combined strong and weak lensing analysis of the J085007.6+360428 (J0850) field, which contains the massive cluster Zwicky 1953. This field was selected for its high projected concentration of luminous red galaxies. Using Subaru/Suprime-Cam ${{BVR}}_{c}{I}_{c}{i}^{\prime }{z}^{\prime }$ imaging and MMT/Hectospec spectroscopy, we first perform a weak lensing shear analysis to constrain the mass distribution in this field, including the cluster at z = 0.3774 and a smaller foreground halo at z = 0.2713. We then add a strong lensing constraint from a multiply imaged galaxy in the imaging data with a photometric redshift of z ≈ 5.03. Unlike previous cluster-scale lens analyses, our technique accounts for the full three-dimensional mass structure in the beam, including galaxies along the line of sight. In contrast with past cluster analyses that used only lensed image positions as constraints, we use the full surface brightness distribution of the images. This method predicts that the source galaxy crosses a lensing caustic, such that one image is a highly magnified "fold arc" that could be used to probe the source galaxy's structure at ultra-high spatial resolution (<30 pc). We calculate the mass of the primary cluster to be ${M}_{\mathrm{vir}}={2.93}_{-0.65}^{+0.71}\times {10}^{15}\,{M}_{\odot }$ with a concentration of ${c}_{\mathrm{vir}}={3.46}_{-0.59}^{+0.70}$, consistent with the mass–concentration relation of massive clusters at a similar redshift. Finally, the large mass of this cluster makes J0850 an excellent field for leveraging lensing magnification to search for high-redshift galaxies, competitive with and complementary to that of well-studied clusters such as the HST Frontier Fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact low resolution spectrograph, an imaging and long slit spectrograph for robotic telescopes

The COmpact LOw REsolution Spectrograph (COLORES) is a compact and lightweight (13 kg) f/8 imaging spectrograph designed for robotic telescopes, now installed and operating on the TELMA, a rapid-slewing 60 cm telescope of the BOOTES-2 observatory in Málaga (Spain). COLORES is a multi-mode instrument that enables the observer to seamlessly switch between low-dispersion spectroscopy and direct imaging modes during an observation. In this paper, we describe the instrument and its development, from the initial scientific requirements through the optical design process to final configuration with theoretical performance calculations. The mechanical and electronic design is described, methods of calibration are discussed and early laboratory and scientific results are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is a promising hydrogen carrier due to its favorable storage and transport characteristics. However, its direct use in combustion systems is limited by low flammability and potential for high nitrogen oxide emissions. To better understand ammonia combustion, researchers conducted experiments using a flat flame burner and measured species profiles using tunable-diode-laser-absorption-spectroscopy and chemiluminescence imaging. They tested three flame conditions with different ammonia-hydrogen blends and oxygen levels. The results were compared to simulations using various kinetic mechanisms, including one that accounts for excited species chemistry. The goal is to provide direct information about species profiles in a simple system, isolating chemical kinetics from fluid dynamic effects, which can inform the development of more efficient and low-emission combustion systems using ammonia.

ammonia combustion↗

Science Measurement Requirements for Imaging Spectrometers from Airborne to Spaceborne

This slide presentation reviews the objectives of the work to create imaging spectrometers. The science objectives are to remotely determine the properties of the surface and atmosphere (physics, chemistry and biology) revealed by the interaction of electromagnetic energy with matter via spectroscopy. It presents a review the understanding of spectral, radiometric and spatial science measurement requirements for imaging spectrometers based upon science research results from past and current airborne and spaceborne instruments. It also examines the future requirements that will enable the next level of imaging spectroscopy science.

radiometric requirements↗

Robust framework and software implementation for fast speciation mapping

One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. In this work, several authors have used different multivariate data processing strategies to establish speciation maps. Furthermore, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. Additionally, the algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.

47 OTHER INSTRUMENTATION↗

Wide-Aperture Aspheric Optics for Formation of Subwavelength Caustics of a Terahertz Electromagnetic-Radiation Beam

A wide-aperture aspheric lens for focusing a terahertz electromagnetic-radiation beam in a circle of the subwavelength size is proposed. The calculation of the lens and the estimation of size of created caustic were carried out using computational methods of geometric optics and electrodynamics. The lens is made of high-density polyethylene with the help of a turning machine. For experimental estimation of the spatial resolution provided by the lens, a THz imaging system based on raster scanning of the object’s surface was created. The imaging system was used in combination with wide-aperture THz optics to record images of the streak plates with different spatial frequencies. Analysis of the experimental data showed that the aspheric lens allows the resolution of two objects spaced at a distance of 0.95λ, providing contrast of 15%. The proposed THz optics is superior to classical THz spherical lenses and off-axis parabolic mirrors, greatly expanding the capabilities of THz-spectroscopy methods and imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Updated models for the creation of a low-Z QSO absorber by a dwarf galaxy wind

We present new GALEX images and optical spectroscopy of J1229+02, a dwarf post-starburst galaxy located 81 kpc from the 1585 km s{sup −1} absorber in the 3C 273 sight line. The absence of Hα emission and the faint GALEX UV fluxes confirm that the galaxy's recent star formation rate is <10{sup −3} M{sub ⊙} yr{sup −1}. Absorption-line strengths and the UV−optical SED give similar estimates of the acceptable model parameters for its youngest stellar population where f{sub m}<60% of its total stars (by mass) formed in a burst t{sub sb}=0.7–3.4 Gyr ago with a stellar metallicity of −1.7<[Fe/H]<+0.2; we also estimate the stellar mass of J1229+02 to be 7.3<log(M{sub ∗}/M{sub ⊙})<7.8. Our previous study of J1229+02 found that a supernova-driven wind was capable of expelling all of the gas from the galaxy (none is observed today) and could by itself plausibly create the nearby absorber. But, using new data, we find a significantly higher galaxy/absorber velocity difference, a younger starburst age, and a smaller starburst mass than previously reported. Simple energy-conserving wind models for J1229+02 using fiducial values of f{sub m}∼0.1, t{sub sb}∼2 Gyr, and log(M{sub ∗}/M{sub ⊙})∼7.5 allow us to conclude that the galaxy alone cannot produce the observed QSO absorber; i.e., any putative ejecta must interact with ambient gas from outside J1229+02. Because J1229+02 is located in the southern extension of the Virgo cluster ample potential sources of this ambient gas exist. Based on the two nearest examples of strong metal-line absorbers discovered serendipitously (the current one and the 1700 km s{sup −1} metal-line absorber in the nearby Q1230 + 0115 sight line), we conclude that absorbers with 10{sup 14}<N{sub H} {sub I}<10{sup 16} cm{sup −2} at impact parameters ≳1 R{sub vir} are likely intergalactic systems and cannot be identified unambiguously as the circumgalactic material of any one individual galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

Rohit Bhartia↗

PymePix : a python library for SPIDR readout of Timepix3

PymePix is a new Python 3 library that provides control and acquisition for the Timepix3-SPIDR hardware. The rich set of data-structures and intuitive routines reduces time and coding effort to quickly configure, acquire, and visualize data from Timepix3. The highly extensible high-performance data-pipeline allows for alteration of the Timepix3 datastream into a form that is convinient for the user. This library is intended to be easily inserted into a standard scientific software stack as well as to allow for more direct interaction of Timepix3 with interactive flavors of Python. Included with the library are two example programs using PymePix: pymepix-acq is a command line control and acquisition program that can capture UDP packets and decode them into pixels and triggers. The second is pymepixviewer, an online control and data-acquisition program for general use, but with features geared toward mass-spectroscopy and ion imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of non‐native species formed during fibrillization of the myocilin olfactomedin domain

Abstract Glaucoma is a group of neurodegenerative diseases that together are the leading cause of irreversible blindness worldwide. Myocilin‐associated glaucoma is an inherited form of this disease, caused by intracellular aggregation of misfolded mutant myocilin. In vitro, the myocilin C‐terminal olfactomedin domain (OLF), the relevant domain for glaucoma pathogenesis, can be driven to form amyloid‐like fibrils under mild conditions. Here we characterize a species present during in vitro fibrillization. Purified OLF was subjected to fibrillization at concentrations required for downstream electron microscopy imaging and NMR spectroscopy. Additional biophysical techniques, including analytical ultracentrifugation and X‐ray crystallography, were employed to further characterize the multicomponent mixture. Negative stain transmission electron microscopy (TEM) shows a non‐native species reminiscent of known prefibrillar oligomers from other amyloid systems, NMR indicates a minor population of partially misfolded species is present in solution, and cryo‐EM imaging shows two‐dimensional protein arrays. The predominant soluble species remaining in solution after the fibril reaction is natively folded, as evidenced by X‐ray crystallography. In summary, after incubating OLF under fibrillization‐promoting conditions, there is a heterogeneous mixture consisting of soluble folded protein, mature amyloid‐like fibrils, and partially misfolded intermediate species that at present belie additional molecular detail. The characterization of OLF fibrillar species illustrates the challenges associated with developing a comprehensive understanding of the fibrillization process for large, non‐model amyloidogenic proteins.

Scelsi, Hailee F. [School of Chemistry and Biochem↗

No Neon, but Jets in the Remarkable Recurrent Nova M31N 2008-12a?—Hubble Space Telescope Spectroscopy of the 2015 Eruption

The 2008 discovery of an eruption of M31N 2008-12a began a journey on which the true nature of this remarkable recurrent nova continues to be revealed. M31N 2008-12a contains a white dwarf (WD) close to the Chandrasekhar limit, accreting at a high rate from its companion, and undergoes thermonuclear eruptions that are observed yearly and may even be twice as frequent. In this paper, we report on Hubble Space Telescope Space Telescope Imaging Spectrograph ultraviolet spectroscopy taken within days of the predicted 2015 eruption, coupled with Keck spectroscopy of the 2013 eruption. Together, this spectroscopy permits the reddening to be constrained to E(B−V)=0.10±0.03. The UV spectroscopy reveals evidence for highly ionized, structured, and high-velocity ejecta at early times. No evidence for neon is seen in these spectra, however, but it may be that little insight can be gained regarding the composition of the WD (CO versus ONe).

79 ASTRONOMY AND ASTROPHYSICS↗

Fluorescence-Correlation Spectroscopy Study of Molecular Transport within Reversed-Phase Chromatographic Particles Compared to Planar Model Surfaces

Reversed-phase liquid chromatography (RPLC) is a widely used technique for molecular separations. Stationary-phase materials for RPLC generally consist of porous silica-gel particles functionalized with n-alkane ligands. Understanding motions of molecules within the interior of these particles is important for developing efficient chromatographic materials and separations. To characterize these dynamics, time-resolved spectroscopic methods (photobleach recovery, fluorescence correlation, single-molecule imaging) have been adapted to measure molecular diffusion rates, typically at n-alkane-modified planar silica surfaces, which serve as models of chromatographic interfaces. A question arising from these studies is how dynamics of molecules on a planar surface relate to motions of molecules within the interior of a porous chromatographic particle. In this paper, imaging-fluorescence-correlation spectroscopy is used to measure diffusion rates of a fluorescent probe molecule 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine perchlorate (DiI) within authentic RPLC porous silica particles and compared with its diffusion at a planar C18-modified surface. The results show that surface diffusion on the planar C18 substrate is much faster than the diffusion rate of the probe molecule through a chromatographic particle. Surface diffusion within porous particles, however, is governed by molecular trajectories along the tortuous contours of the interior surface of the particles. By accounting for the greater surface area that a molecule must explore to diffuse macroscopic distances through the particle, the molecular-scale diffusion rates on the two surfaces can be compared, and they are virtually identical. Furthermore, these results provide support for the relevance of surface-diffusion measurements made on planar model surfaces to the dynamic behavior of molecules on the internal surfaces of porous chromatographic particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vibrational Spectroscopy of Water with High Spatial Resolution

Abstract The ability to examine the vibrational spectra of liquids with nanometer spatial resolution will greatly expand the potential to study liquids and liquid interfaces. In fact, the fundamental properties of water, including complexities in its phase diagram, electrochemistry, and bonding due to nanoscale confinement are current research topics. For any liquid, direct investigation of ordered liquid structures, interfacial double layers, and adsorbed species at liquid–solid interfaces are of interest. Here, a novel way of characterizing the vibrational properties of liquid water with high spatial resolution using transmission electron microscopy is reported. By encapsulating water between two sheets of boron nitride, the ability to capture vibrational spectra to quantify the structure of the liquid, its interaction with the liquid‐cell surfaces, and the ability to identify isotopes including H 2 O and D 2 O using electron energy‐loss spectroscopy is demonstrated. The electron microscope used here, equipped with a high‐energy‐resolution monochromator, is able to record vibrational spectra of liquids and molecules and is sensitive to surface and bulk morphological properties both at the nano‐ and micrometer scales. These results represent an important milestone for liquid and isotope‐labeled materials characterization with high spatial resolution, combining nanoscale imaging with vibrational spectroscopy.

Jokisaari, Jacob R.↗

SU-F-P-03: Management of Time to Treatment Inititation: Case for An Electronic Whiteboard

Purpose: To determine if data mining of an electronic whiteboard improves the management of the Time to Treatment Initiation (TTI) in radiation oncology. Methods: An electronic whiteboard designed to help in managing the planning workflow and improves communication regarding patient planning progress was used to record the dates at which each phase of the planning process began or completed. These are CT Sim date, Plan Start, Physician Review, Physicist Review, Approval for Treatment Delivery, Setup or Verification of Simulation. Results: During clinical implementation, the electronic whiteboard was able to fulfill its primary objective of providing a transparent account of the planning progress of each patient. Peer pressure also meant that individual tasks, such as contouring, were easily brought to the attention of the responsible party and prioritized accordingly. Data mining to analyze the electronic whiteboard per patient (figure 1), per diagnosis (figure 2), per treatment modality (figure 3), per physician (figure 4), per planner (figure 5), etc., added another sophisticated tool in the management of Time to Treatment Initiation without compromising quality of the plans being generated. A longer than necessary time between CT Sim and Plan Start can be discussed among the members of the treatment team as an indication of inadequate/outdated CT Simulator, Contouring Tools, Image Fusion Tools, Other Imaging Studies (MRI, PET/CT) performed, etc. The same for the Plan Start to Physician Review where an extended time than expected may be due unrealistic planning goals, limited planning system features, etc. Conclusion: An Electronic Whiteboard in radiation oncology is not only helping with organizing planning workflow, it is also a potent tool that can be used to reduce the Time to Treatment Initiation by providing the clinic with hard data about the duration of each phase treatment planning as a function of different variable affecting the planning process. The work is supported by the Global Medical Physics Institute.

60 APPLIED LIFE SCIENCES↗

Development of a new photoelectron spectroscopy instrument combining an electrospray ion source and photoelectron imaging

A new apparatus has been constructed that combines electrospray ionization with a quadrupole mass filter, hexapole ion trap, and velocity-map imaging. The purpose is to record photoelectron images of isolated chromophore anions. To demonstrate the capability of our instrument we have recorded the photodetachment spectra of isolated deprotonated phenol and indole anions. To our knowledge, this is the first time that the photodetachment energy of the deprotonated indole anion has been recorded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗