In situ spectral calibration method for the impurity influx monitor (divertor) for ITER using angled physical contact fibers

The in situ calibration method for the impurity influx monitor (divertor) is experimentally examined. The total reflectance of the optical path from the focal point of the Cassegrain telescope to the first mirror is derived using a micro retroreflector array. An optical fiber with angled physical contact (APC) connectors reduces the return edge reflection. APC fibers and a multimode coupler increase the signal-to-noise ratio by about one order compared to that of triple-branched fibers and enable measurement of the wavelength dependence of the total reflectance of the optical system even after potential deterioration of mirror surfaces reduces reflectance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of voltage holding and high current beam acceleration by MeV accelerator for ITER NB

Voltage holding of -1 MV is an essential issue in development of a multi-aperture multi-grid (MAMuG) negative ion accelerator, of which target is to accelerate 200 A/m{sup 2} H{sup -} ion beam up to the energy of 1 MeV for several tens seconds. Review of voltage holding results ever obtained with various geometries of the accelerators showed that the voltage holding capability was about a half of designed value based on the experiment obtained from ideal small electrode. This is considered due to local electric field concentration in the accelerators, such as edge and steps between multi-aperture grids and its support structures. Based on the detailed investigation with electric field analysis, accelerator was modified to reduce the electric field concentration by reshaping the support structures and expanding the gap length between the grid supports. After the modifications, the accelerator succeeded in sustaining -1 MV for more than one hour in vacuum. Improvement of the voltage holding characteristics progressed the energy and current accelerated by the MeV accelerator. Up to 2010, beam parameters achieved by the MAMuG accelerator were increased to 879 keV, 0.36 A (157 A/m{sup 2}) at perveance matched condition and 937 keV, 0.33 A (144 A/m{sup 2}) slightly under perveance.

43 PARTICLE ACCELERATORS↗

Extraction of a strongly focusing He{sup +} beam from three-stage concave electrodes for alpha particle measurement system in ITER

A strongly focusing He{sup +} ion beam source equipped with concave multi-aperture electrodes was developed for production of He{sup -} through a charge exchange cell. The beam was extracted at a voltage less than 20 kV from 301 apertures distributed in an area of 100 mm {phi}, and focused at 750 mm distance. The beam current and the beam size of 2 A and 20 mm in diameter, respectively, were achieved with an arc power less than 10 kW. The optimum perveance was obtained at 0.02 A/kV{sup 1.5} at the beam energy less than 20 keV which is suitable for the conversion to He{sup -} in an alkali vapor cell.

43 PARTICLE ACCELERATORS↗

Cryodynamics can solve the energy problem by stabilizing ITER: A prediction

An optimistic scenario is sketched which only at first sight appears unrealistic. The ingredients go back to the names of Zwicky and Chandrasekhar. Thermodynamics is not the only basis on which to build macroscopic machines. The recently described sister discipline of cryodynamics is characterized by a decrease in entropy and enables thereby, in conjunction with the entropy increase of thermodynamics, an eternally recycling cosmos. A first down-to-earth application is proposed that would be highly beneficial in stabilizing hot fusion. Skepticism and hope still are in balance but a new industrial age with unlimited energy is proposed to be dawning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a backscatter 14-MeV neutron time-of-flight spectrometer for experiments at ITER

Neutron energy spectrometry diagnostics play an important role in present-day experiments related to fusion energy research. Measurements and thorough analysis of the neutron emission from the fusion plasma give information on a number of basic fusion performance quantities, on the condition of the neutron source and plasma behavior. Here we discuss the backscatter Time-of-Flight (bTOF) spectrometer concept as a possible instrument for performing high resolution measurements of 14 MeV neutrons. The instrument is based on two sets of scintillators, a first scatterer exposed to a collimated neutron beam and a second detector set placed in the backward direction. The scintillators of the first set are enriched in deuterium to achieve neutron backscattering. The energy resolution and efficiency of a bTOF instrument have been determined for various geometrical configurations. A preliminary design of optimal geometry for the two scintillator sets has been obtained by Monte Carlo simulations based on the MCNPX code.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of the negative ion beams relevant to ITER and JT-60SA at Japan Atomic Energy Agency

In order to realize negative ion sources and accelerators to be applicable to International Thermonuclear Experimental Reactor and JT-60 Super Advanced, a large cesium (Cs)-seeded negative ion source and a multi-aperture and multi-stage electric acceleration have been developed at Japan Atomic Energy Agency (JAEA). Long pulse production and acceleration of the negative ion beams have been independently carried out. The long pulse production of the high current beams has achieved 100 s at the beam current of 15 A by modifying the JT-60 negative ion source. The pulse duration time is increased three times longer than that before the modification. As for the acceleration, a pulse duration time has been also extended two orders of magnitudes from 0.4 s to 60 s. The developments of the negative ion source and acceleration at JAEA are well in progress towards the realization of the negative ion sources and accelerators for fusion applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-vessel calibration of the imaging diagnostics for the real-time protection of the JET ITER-like wall

The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nash equilibrium in differential games and the construction of the programmed iteration method

This work is devoted to the study of nonzero-sum differential games. The set of payoffs in a situation of Nash equilibrium is examined. It is shown that the set of payoffs in a situation of Nash equilibrium coincides with the set of values of consistent functions which are fixed points of the program absorption operator. A condition for functions to be consistent is given in terms of the weak invariance of the graph of the functions under a certain differential inclusion. Bibliography: 18 titles.

97 MATHEMATICS AND COMPUTING↗

Mixed-precision iterative refinement using tensor cores on GPUs to accelerate solution of linear systems

Double-precision floating-point arithmetic (FP64) has been the de facto standard for engineering and scientific simulations for several decades. Problem complexity and the sheer volume of data coming from various instruments and sensors motivate researchers to mix and match various approaches to optimize compute resources, including different levels of floating-point precision. In recent years, machine learning has motivated hardware support for half-precision floating-point arithmetic. A primary challenge in high-performance computing is to leverage reduced-precision and mixed-precision hardware. We show how the FP16/FP32 Tensor Cores on NVIDIA GPUs can be exploited to accelerate the solution of linear systems of equations Ax = b without sacrificing numerical stability. The techniques we employ include multiprecision LU factorization, the preconditioned generalized minimal residual algorithm (GMRES), and scaling and auto-adaptive rounding to avoid overflow. We also show how to efficiently handle systems with multiple right-hand sides. On the NVIDIA Quadro GV100 (Volta) GPU, we achieve a 4×-5× performance increase and 5× better energy efficiency versus the standard FP64 implementation while maintaining an FP64 level of numerical stability.

GMRES↗

TU-A-9A-03: Development and Verification of a Forward Model That Assists in Iterative Post-Processing Algorithms Used to Reduce Blur in Compton Backscatter Imaging Systems

Purpose: In Compton Backscatter Imaging (CBI), the source and detector reside on the same side of the patient. We previously demonstrated the applicability of CBI systems for medical purposes using an industrial system. To assist in post-processing images from a CBI system, a forward model based on radiation absorption and scatter principles has been developed. Methods: The forward model was developed in C++ using raytracing to track particles. The algorithm accepts phantoms of any size and resolution to calculate the fraction of incident photons scattered back to the detector, and can perform these calculations for any detector geometry and source specification. To validate the model, results were compared to MCNP-X, which is a Monte Carlo based simulation software, for various combinations of source specifications, detector geometries, and phantom compositions. Results: The model verified that the backscatter signal to the detector was based on three interaction probabilities: a) attenuation of photons going into the phantom, b) Compton scatter of photons toward the detector, and c) attenuation of photons coming out of the phantom. The results from the MCNP-X simulations and the forward model varied from 1 to 5%. This difference was less than 1% for energies higher than 30 keV, but was up to 4% for lower energies. At 50 keV, the difference was less than 1% for multiple detector widths and for both homogeneous and heterogeneous phantoms. Conclusion: As part of the optimization of a medical CBI system, an efficient and accurate forward model was constructed in C++ to estimate the output of CBI system. The model characterized individual components contributing to CBI output and increased computational efficiency over Monte Carlo simulations. It is now used in the development of novel post-processing algorithms that reduce image blur by reversing undesired contribution from outside the region of interest.

07 ISOTOPE AND RADIATION SOURCES↗

MO-FG-204-09: High Spatial Resolution and Artifact-Free CT Bone Imaging at Off-Centered Positions: An Application of Model-Based Iterative Reconstruction

Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positions using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p<1e-3) and a 68% increase in noise nonuniformity (p<0.02). A visible drop in bone sharpness was observed. In contrast, no significant difference in the noise magnitude or the noise nonuniformity between the centered and off-centered MBIR images was found. The image sharpness of off-centered MBIR images outperformed that of FBP images reconstructed with the Bone Plus kernel. In images of the swine elbow off-centered by 20 cm, not only was the noise and spatial resolution performance improved by MBIR, truncation artifacts were also elliminated. The human subject study generated similar results, in which the visibility of the off-centered lumbar spine was significantly improved. Conclusion: High quality CT bone imaging at off-centered positions can be achieved using MBIR. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX. A. Budde, J. Hsieh: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-03: Task-Based KV and MAs Optimization for Radiation Dose Reduction in CT: From FBP to Statistical Model-Based Iterative Reconstruction (MBIR)

Purpose: The introduction of the highly nonlinear MBIR algorithm to clinical CT systems has made CNR an invalid metric for kV optimization. The purpose of this work was to develop a task-based framework to unify kV and mAs optimization for both FBP- and MBIR-based CT systems. Methods: The kV-mAs optimization was formulated as a constrained minimization problem: to select kV and mAs to minimize dose under the constraint of maintaining the detection performance as clinically prescribed. To experimentally solve this optimization problem, exhaustive measurements of detectability index (d’) for a hepatic lesion detection task were performed at 15 different mA levels and 4 kV levels using an anthropomorphic phantom. The measured d’ values were used to generate an iso-detectability map; similarly, dose levels recorded at different kV-mAs combinations were used to generate an iso-dose map. The iso-detectability map was overlaid on top of the iso-dose map so that for a prescribed detectability level d’, the optimal kV-mA can be determined from the crossing between the d’ contour and the dose contour that corresponds to the minimum dose. Results: Taking d’=16 as an example: the kV-mAs combinations on the measured iso-d’ line of MBIR are 80–150 (3.8), 100–140 (6.6), 120–150 (11.3), and 140–160 (17.2), where values in the parentheses are measured dose values. As a Result, the optimal kV was 80 and optimal mA was 150. In comparison, the optimal kV and mA for FBP were 100 and 500, which corresponded to a dose level of 24 mGy. Results of in vivo animal experiments were consistent with the phantom results. Conclusion: A new method to optimize kV and mAs selection has been developed. This method is applicable to both linear and nonlinear CT systems such as those using MBIR. Additional dose savings can be achieved by combining MBIR with this method. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona, M. G. Lubner: Nothing to disclose. P. J. Pickhardt: Co-founder, VirtuoCTC, LLC Stockholder, Cellectar Biosciences, Inc. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX.