Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

High resolution analysis of three bands of the electronic transition A{sup 2}Σ{sup +}-X{sup 2}Π of N{sub 2}O{sup +} radical: 100-000, 000-001, and 001-001

In this article three vibrational bands of the electronic transition A{sup 2}Σ{sup +}-X{sup 2}Π of the N{sub 2}O{sup +} radical (100-000, 000-001, and 001-001) are analysed through high resolution Fourier transform spectroscopy. The N{sub 2}O{sup +} radical was produced by Penning ionization of N{sub 2}O by colliding with metastable atoms of He(2{sup 3}S) in a reaction chamber. The spectra was recorded in a spectral range of 24 500–30 000 cm{sup −1} and obtained from 200 coadded interferograms recorded at an apodized resolution of 0.08 cm{sup −1}. Through a recursive way, the wavenumbers of the correspondent rotational transitions were reduced into molecular constants, improving the values previously reported. New values for the first vibrational energies ν{sub 1}{sup ′}, ν{sub 3}{sup ″}, and ν{sub 3}{sup ′} are also obtained and compared with previous values reported in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Measurement techniques and applications of charge transfer to aerospace research

A technique of developing high-velocity low-intensity neutral gas beams for use in aerospace research problems is described. This technique involves ionization of gaseous species with a mass spectrometer and focusing the resulting primary ion beam into a collision chamber containing a static gas at a known pressure and temperature. Equations are given to show how charge-transfer cross sections are obtained from a total-current measurement technique. Important parameters are defined for the charge-transfer process.

Smith, A.↗

Arc/gas electrode

A gas/arc electrode is disclosed for use under vacuum conditions where a first housing encloses a second housing, with an end of the second housing extending through an opening in the first housing and having an outlet orifice. Provisions are made for circulating a coolant through the first housing to surround and cool the second housing. An electrical current and a gas, such as argon, as passed through the second housing, with the current flowing through a narrow stream of the ionized gas flowing through the outlet orifice to a workpiece to be treated. The second housing forms a chamber which has a cross sectional area, in a plane perpendicular to the direction of gas flow, of at least ten times the cross sectional area of the outlet orifice such that a gas pressure can be maintained in the chamber to reduce erosion of the chamber walls.

Poorman, Richard M.↗

First Optical Constants of Laboratory-Generated Organic Refractory Materials (Tholins) Produced in the NASA Ames COSmIC Facility from the Visible to the Near Infrared (0.4–1.6 μm): Application to Titan’s Aerosols

We have measured the complex refractive indices, from 0.4 to 1.6μm, of five laboratory-generated organic refractory materials (tholins) produced at low temperature(150 K)using plasma chemistry in the stream of a supersonic expansion in NASA Ames’ COsmic SImulation Chamber(COSmIC)facility. Three samples were produced from N2:CH4gas precursors(with different voltages inducing different degrees of ionization in the plasma), one sample was produced from N2:CH4:C2H2, and one sample was produced from Ar:CH4in order to produce a purely carbonaceous sample. The optical constants, n and k, of the samples were determined using spectral reflectance measurements. We observe that both n and k appear to be correlated with the nitrogen content in the solid sample, with samples containing more nitrogen having higher n and k. Comparisons to previous laboratory studies and Titan aerosol optical constants derived from observations show that the COSmIC tholins with a higher nitrogen content (higher n and k)are closer analogs of Titan aerosols. We also present a new analysis of Cassini Visible Infrared Mapping Spectrometer observations of Titan’s atmosphere in the visible to near infrared using the COSmIC tholin optical constants in a radiative transfer model. The COSmIC tholin sample produced from N2:CH4with the lowest energy level has a spectral behavior that appears well suited to reproduce the observed Titan aerosol properties. This study has therefore demonstrated that this COSmIC tholin sample has valuable and promising optical properties for the analysis of Cassini’s Titan atmospheric observations.

Optical Constants↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

Mapping and imaging ionizing radiation in two and three dimensions

A two-dimensional imaging system and a two-dimensional or three-dimensional optical tomographic mapping system, each employing gas scintillation induced by ionizing radiation, i.e., radioluminescence, and corresponding methods, are disclosed. The systems may employ one or more cameras and corresponding UV filters (potentially solar blind filters) for imaging a radioluminescent scene. For two-dimensional or three-dimensional mapping, the resultant UV images are spatially registered with one another and then reconstructed to form a three-dimensional tomographic map of the ionizing radiation. The two-dimensional map is a plane of the three-dimensional map. The UV images may be spatially registered by using a reference source, optionally, a calibrated reference source allowing dosimetry calculations for the ionizing radiation. Molecular nitrogen is the primary candidate for the radioluminescent gas, though a controlled ambient in a chamber of nitric oxide, argon, krypton, or xenon may be employed. The reconstruction process employs an algebraic reconstruction technique or an Abel inversion.

Bentz, Brian Z.↗

Sub-band-gap photoconductivity in Co2+-doped ZnO

Variable-temperature and polarized scanning photoconductivity measurements on Zn1-xCoxO epitaxial films allow description of Co2+-derived sub-bandgap photoionization excited states in this archetypal diluted magnetic oxide. Low-temperature (27 K) measurements demonstrate spontaneous ionization from the photo-generated 4T1(P) d-d excited state, despite the highly localized nature of this excitation. Ionization involves relaxation from this d-d state to the lower Co2+/3+ donor-type photoionization level. Variable-temperature photoconductivity measurements reveal an additional thermally assisted ionization process that enhances the d-d photoconductivity at higher temperatures. The energy barrier to thermal ionization from the 4T1(P) excited state at low temperatures is estimated to be Ea ≈ 40 meV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gaseous time projection chambers for rare event detection: results from the T-REX project. I. Double beta decay

As part of the T-REX project, a number of R and D and prototyping activities have been carried out during the last years to explore the applicability of gaseous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) in rare event searches like double beta decay, axion research and low-mass WIMP searches. In both this and its companion paper, we compile the main results of the project and give an outlook of application prospects for this detection technique. While in the companion paper we focus on axions and WIMPs, in this paper we focus on the results regarding the measurement of the double beta decay (DBD) of {sup 136}Xe in a high pressure Xe (HPXe) TPC. Micromegas of the microbulk type have been extensively studied in high pressure Xe and Xe mixtures. Particularly relevant are the results obtained in Xe + trimethylamine (TMA) mixtures, showing very promising results in terms of gain, stability of operation, and energy resolution at high pressures up to 10 bar. The addition of TMA at levels of ∼ 1% reduces electron diffusion by up to a factor of 10 with respect to pure Xe, improving the quality of the topological pattern, with a positive impact on the discrimination capability. Operation with a medium size prototype of 30 cm diameter and 38 cm of drift (holding about 1 kg of Xe at 10 bar in the fiducial volume, enough to contain high energy electron tracks in the detector volume) has allowed to test the detection concept in realistic experimental conditions. Microbulk Micromegas are able to image the DBD ionization signature with high quality while, at the same time, measuring its energy deposition with a resolution of at least a ∼ 3% FWHM @ Q{sub ββ}. This value was experimentally demonstrated for high-energy extended tracks at 10 bar, and is probably improvable down to the ∼ 1% FWHM levels as extrapolated from low energy events. In addition, first results on the topological signature information (one straggling track ending in two blobs) show promising background discrimination capabilities out of reach of other experimental implementations. Moreover, microbulk Micromegas have very low levels of intrinsic radioactivity, and offer cost-effective scaling-up options. All these results demonstrate that Micromegas-read HPXe TPC remains a very competitive technique for the next generation DBD experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon

We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We also report measurements of the scintillation yields for nuclear recoils with energies from 10.3 to 57.3 keV and for median applied electric fields from 0 to 970 V/cm. For the ionization yields, we report measurements from 16.9 to 57.3 keV and for electric fields from 96.4 to 486 V/cm. Furthermore, we report the observation of an anticorrelation between scintillation and ionization from nuclear recoils, which is similar to the anticorrelation between scintillation and ionization from electron recoils. Assuming that the energy loss partitions into excitons and ion pairs from 83m Kr internal conversion electrons is comparable to that from 207 Bi conversion electrons, we obtained the numbers of excitons (N ex ) and ion pairs (N i ) and their ratio (N ex /N i ) produced by nuclear recoils from 16.9 to 57.3 keV. Motivated by arguments suggesting direction sensitivity in LAr-TPC signals due to columnar recombination, a comparison of the light and charge yield of recoils parallel and perpendicular to the applied electric field is presented for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber

In this work, the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Building a multi-cathode-gas-filled scintillator detector for fission fragments

Radiation cannot be detected directly by human senses, indeed detecting and identifying the fission products or decay yield with high accuracy is a great challenge for experimental physicist. In this work we are building a Multi-Cathode-Gas-filled Scintillator MCGS detector. The detector consists of two parts. First: anode-wire proportional chamber and cathode strip foil, which measure the energy loss of the particles in the gas, due to the ionization, and identifies the position of the products on the detector plane depending on their energy with the presence of a magnetic field. Second: a 7 mm thick scintillator attached to a photomultiplier tube in the back end of the detector. This part measures the rest energy of the particles. A data acquisition system records the events and the particles infonnation. The yields are identified from the energy loss to rest energy ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-induced fission fragment angular distributions, anisotropy, and linear momentum transfer measured with the NIFFTE fission time projection chamber

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measuring the opening angle between the fission fragments. Using this measured linear momentum, fission fragment angular distributions can be converted to the center-of-mass frame for anisotropy measurements. Angular anisotropy is an important experimental observable for understanding the quantum mechanical state of the fissioning nucleus and vital to determining detection efficiency for cross section measurements. Neutron linear momentum transfer to fissioning 235 U, 238 U, and 239Pu and fission fragment angular anisotropy of 235 U and 238 U as a function of neutron energies in the range 130 keV–250 MeV are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring the readout temperature in the ICARUS TPC (2023 Italian Students Program Final Report)

Being a Liquid Argon Time Projection Chamber (LAr-TPC) detector, ICARUS exploits a series of three parallel wire planes to measure and collect the ionization charge coming from an event inside the active volume. The wires are read out by A2795 custom boards, arranged in crates located on top of the two liquid Argon vessels. Each board is provided with two temperature sensors that allow temperature monitoring while the experiment is running: this is key in order to ensure data reliability and maintain hardware in safe conditions. Moreover, temperature-related problems may force unplanned shutdowns that result in losing valuable time for the experiment to run. In this work we are discussing the characterization of the ICARUS TPC board temperatures and the system we implemented in order to monitor them effectively. Among the tools used, Grafana results in a valid application for both displaying temperature data and sending alerts to the shifters whenever a pathological situation occurs.

42 ENGINEERING↗

Gas flow analysis during thermal vacuum test of a spacecraft.

The pressures indicated by two tubulated ionization gages, one pointing to a spinning spacecraft undergoing thermal vacuum test and the other the walls of the chamber, have been used in a computer program to calculate important parameters of flow kinetics in the vacuum chamber. These parameters calculated as a function of time are: the self-contamination of the spacecraft (defined as the return of outgassed molecules on its critical surfaces either in orbit or while undergoing vacuum test); the spacecraft outgassing including leaks from sealed compartments; and the gas pumping performance of the vacuum chamber. The test indicated the feasibility of this type of evaluation and the improvements in instrumentations and arrangements needed for future tests.

Scialdone, J. J.↗

Gas Pressure Gauge Based on Alpha-Particle Induced Ion Currents

The use of ionization currents for measuring pressure was first demonstrated in the late 1940's. The early gauges operated at high voltages and used rather large ion sources. The ionization gauge is actually a densitometer that is sensitive to the temperature and pressure of the gas in the chamber. This report describes the use of low voltages and small ion sources in the development of a prototype.

transducers gas pressure gauge alpha particles ion↗

Large area plasma source

An all permanent magnet Electron Cyclotron Resonance, large diameter (e.g., 40 cm) plasma source suitable for ion/plasma processing or electric propulsion, is capable of producing uniform ion current densities at its exit plane at very low power (e.g., below 200 W), and is electrodeless to avoid sputtering or contamination issues. Microwave input power is efficiently coupled with an ionizing gas without using a dielectric microwave window and without developing a throat plasma by providing a ferromagnetic cylindrical chamber wall with a conical end narrowing to an axial entrance hole for microwaves supplied on-axis from an open-ended waveguide. Permanent magnet rings are attached inside the wall with alternating polarities against the wall. An entrance magnet ring surrounding the entrance hole has a ferromagnetic pole piece that extends into the chamber from the entrance hole to a continuing second face that extends radially across an inner pole of the entrance magnet ring.

Foster, John↗

Effect of dimethylamine on the gas phase sulfuric acid concentration measured by Chemical Ionization Mass Spectrometry

Abstract Sulfuric acid is widely recognized as a very important substance driving atmospheric aerosol nucleation. Based on quantum chemical calculations it has been suggested that the quantitative detection of gas phase sulfuric acid (H 2 SO 4 ) by use of Chemical Ionization Mass Spectrometry (CIMS) could be biased in the presence of gas phase amines such as dimethylamine (DMA). An experiment (CLOUD7 campaign) was set up at the CLOUD (Cosmics Leaving OUtdoor Droplets) chamber to investigate the quantitative detection of H 2 SO 4 in the presence of dimethylamine by CIMS at atmospherically relevant concentrations. For the first time in the CLOUD experiment, the monomer sulfuric acid concentration was measured by a CIMS and by two CI‐APi‐TOF (Chemical Ionization‐Atmospheric Pressure interface‐Time Of Flight) mass spectrometers. In addition, neutral sulfuric acid clusters were measured with the CI‐APi‐TOFs. The CLOUD7 measurements show that in the presence of dimethylamine (<5 to 70 pptv) the sulfuric acid monomer measured by the CIMS represents only a fraction of the total H 2 SO 4 , contained in the monomer and the clusters that is available for particle growth. Although it was found that the addition of dimethylamine dramatically changes the H 2 SO 4 cluster distribution compared to binary (H 2 SO 4 ‐H 2 O) conditions, the CIMS detection efficiency does not seem to depend substantially on whether an individual H 2 SO 4 monomer is clustered with a DMA molecule. The experimental observations are supported by numerical simulations based on A Self‐contained Atmospheric chemistry coDe coupled with a molecular process model (Sulfuric Acid Water NUCleation) operated in the kinetic limit.

CLOUD experiment↗