Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INERTIAL CONFINEMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Three-dimensional hot-spot x-ray emission tomography from cryogenic deuterium–tritium direct-drive implosions on OMEGA

A three-dimensional model of the hot-spot x-ray emission has been developed and applied to the study of low-mode drive asymmetries in direct-drive inertial confinement fusion implosions on OMEGA with cryogenic deuterium–tritium targets. Here, the steady-state model assumes an optically thin plasma and the data from four x-ray diagnostics along quasi-orthogonal lines of sight are used to obtain a tomographic reconstruction of the hot spot. A quantitative analysis of the hot-spot shape is achieved by projecting the x-ray emission into the diagnostic planes and comparing this projection to the measurements. The model was validated with radiation-hydrodynamic simulations assuming a mode-2 laser illumination perturbation resulting in an elliptically shaped hot spot, which was accurately reconstructed by the model using synthetic x-ray images. This technique was applied to experimental data from implosions in polar-direct-drive illumination geometry with a deliberate laser-drive asymmetry, and the hot-spot emission was reconstructed using spherical-harmonic modes of up to ℓ = 3. A 10% stronger drive on the equator relative to that on the poles resulted in a prolate-shaped hot spot at stagnation with a large negative A 2,0 coefficient of A 2,0 = –0.47 ± 0.03, directly connecting the modal contribution of the hot-spot shape with the modal contribution in laser-drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray imaging and radiation transport effects on cylindrical implosions

Magnetization of inertial confinement implosions is a promising means of improving their performance, owing to the potential reduction of energy losses within the target and mitigation of hydrodynamic instabilities. In particular, cylindrical implosions are useful for studying the influence of a magnetic field, thanks to their axial symmetry. In this work, we present experimental results from cylindrical implosions on the OMEGA-60 laser using a 40-beam, 14.5 kJ, 1.5 ns drive and an initial seed magnetic field of B 0 = 30 T along the axes of the targets, compared with reference results without an imposed B-field. Implosions were characterized using time-resolved x-ray imaging from two orthogonal lines of sight. We found that the data agree well with magnetohydrodynamic simulations, once radiation transport within the imploding plasma is considered. We show that for a correct interpretation of the data in these types of experiments, explicit radiation transport must be taken into account.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specular reflections (“glint”) of the inner beams in a gas-filled cylindrical hohlraum

Herein we report on the experimental measurement of specular reflection (“glint”) of laser beams off the hohlraum wall in inertial confinement fusion experiments at the National Ignition Facility. In a hohlraum, glinted light can escape the opposite laser entrance hole of the hohlraum and is a potential laser energy loss mechanism. The total measured glint on the inner cones of beams is measured to be less than 8 TW (when using the full National Ignition Facility laser), which is <2% of incident peak power. The simulated x-ray flux exceeds the measurement by 10%–20%, and glinted laser light is unable to account for this discrepancy. Similar inner beam glint was measured for ρ = 0.3 and 0.6 mg/cc gas fill hohlraums, but no glint was detected for 1.2 mg/cc densities. Inner beam glint is dominated by the lowest angle 21.5 beams within a 23.5 quad, and it is at most 30% sensitive to different quad polarization arrangements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design optimization for Richtmyer–Meshkov instability suppression at shock-compressed material interfaces

We report the Richtmyer–Meshkov instability (RMI) is a phenomenon that occurs at the interface of two substances of different densities due to an impulsive acceleration, such as a shock wave passing through this interface. Under these conditions, the instability can be seen as interface perturbations begin to grow into narrow jets or spikes of one substance that propagate into the other. In some cases, this interface may involve an elastic–plastic material, which can play a significant role in the development and behavior of the RMI. The ability to effectively control RMI jetting and spike growth is one major limiting factor in technological challenges, such as inertial confinement fusion, that involve using high-pressure shock waves to implode a fuel target. The propagation of RMI growth can lead to increased asymmetry in this implosion process and significantly reduce the obtained energy yield. We use hydrodynamics simulations of impactor shock-compression experiments and methods based in design optimization to suppress RMI spike growth by altering the geometry and other properties of a shock-compressed elastic–plastic material target that shares an interface with atmospheric air. These hydrodynamics simulations use an arbitrary Lagrangian–Eulerian method with a high-order finite element approach. Our results demonstrate that RMI suppression can be achieved by intentionally creating a separate upstream interface instability to counteract the growth of long narrow RMI spikes at an interface with initial perturbations.

36 MATERIALS SCIENCE↗

Characterization of the hardened single line of sight camera at the National Ignition Facility

The hardened single line of sight camera has been recently characterized in preparation for its deployment on the National Ignition Facility. The latest creation based on the pulse-dilation technology leads to many new features and improvements over the previous-generation cameras to provide better quality measurements of inertial confinement fusion experiments, including during high neutron yield implosions. Here, we present the characterization data that illustrate the main performance features of this instrument, such as extended dynamic range and adjustable internal magnification, leading to improved spatial resolution.

Trosseille, C. (ORCID:0000000289430482)↗

The development of a high-resolution Eulerian radiation-hydrodynamics simulation capability for laser-driven Hohlraums

Hohlraums are hollow cylindrical cavities with high-Z material walls used to convert laser energy into uniform x-ray radiation drives for inertial confinement fusion capsule implosions and high energy density physics experiments. Credible computational modeling of hohlraums requires detailed modeling and coupling of laser physics, hydrodynamics, radiation transport, heat transport, and atomic physics. We report on improvements to Los Alamos National Laboratory's xRAGE radiation-hydrodynamics code in order to enable hohlraum modeling. xRAGE's Eulerian hydrodynamics and adaptive mesh refinement make it uniquely well suited to study the impacts of multiscale features in hohlraums. In order to provide confidence in this new modeling capability, we demonstrate xRAGE's ability to produce reasonable agreement with data from several benchmark hohlraum experiments. We also use xRAGE to perform integrated simulations of a recent layered high density carbon capsule implosion on the National Ignition Facility in order to evaluate the potential impacts of the capsule support tent, mixed cell conductivity methodologies, plasma transport, and cross-beam energy transfer (XBT). We find that XBT, seeded by plasma flows in the laser entrance hole (LEH), causes a slight decrease in energy coupling to the capsule and that all of these impact the symmetry of the x-ray drive such that they have an appreciable impact on the capsule implosion shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

Neutron time-of-flight detectors (nTOF) used at Sandia’s Z-Machine

Neutron time-of-flight (nTOF) detectors have been used on Sandia National Laboratories’ Z-Machine for inertial confinement fusion and magnetized liner fusion experiments to infer physics parameters including the apparent fuel-ion temperature, neutron yield, the magnetic-radius product (BR), and the liner rho-r. Single-paddle, dual-paddle, and co-axial scintillation nTOF detectors are used in axial lines-of-sight (LOS) and LOS that are 12° from the midplane. Detector fabrication, characterization, and calibration are discussed.

Chandler, G. A. (ORCID:0000000219640927)↗

Design of the high-yield time-gated x-ray hot-spot imager for OMEGA

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester’s OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium–tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick–Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 10 14 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 μm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal–oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. As a result, the technical design space for the instrument will be discussed and the conceptual design will be presented.

47 OTHER INSTRUMENTATION↗

Machine learning for detection of 3D features using sparse x-ray tomographic reconstruction

In many inertial confinement fusion (ICF) experiments, the neutron yield and other parameters cannot be completely accounted for with one and two dimensional models. This discrepancy suggests that there are three dimensional effects that may be significant. Sources of these effects include defects in the shells and defects in shell interfaces, the fill tube of the capsule, and the joint feature in double shell targets. Due to their ability to penetrate materials, x rays are used to capture the internal structure of objects. Methods such as computational tomography use x-ray radiographs from hundreds of projections, in order to reconstruct a three dimensional model of the object. In experimental environments, such as the National Ignition Facility and Omega-60, the availability of these views is scarce, and in many cases only consists of a single line of sight. Mathematical reconstruction of a 3D object from sparse views is an ill-posed inverse problem. These types of problems are typically solved by utilizing prior information. Neural networks have been used for the task of 3D reconstruction as they are capable of encoding and leveraging this prior information. We utilize half a dozen, different convolutional neural networks to produce different 3D representations of ICF implosions from the experimental data. Deep supervision is utilized to train a neural network to produce high-resolution reconstructions. These representations are used to track 3D features of the capsules, such as the ablator, inner shell, and the joint between shell hemispheres. Machine learning, supplemented by different priors, is a promising method for 3D reconstructions in ICF and x-ray radiography, in general.

Wolfe, Bradley T. (ORCID:0000000268301614)↗

A 2–4 keV multilayer mirrored channel for the NIF Dante system

During inertial confinement fusion experiments at the National Ignition Facility (NIF), a capsule filled with deuterium and tritium (DT) gas, surrounded by a DT ice layer and a high-density carbon ablator, is driven to the temperature and densities required to initiate fusion. In the indirect method, 2 MJ of NIF laser light heats the inside of a gold hohlraum to a radiation temperature of 300 eV; thermal x rays from the hohlraum interior couple to the capsule and create a central hotspot at tens of millions degrees Kelvin and a density of 100–200 g/cm3. During the laser interaction with the gold wall, m-band x rays are produced at ∼2.5 keV; these can penetrate into the capsule and preheat the ablator and DT fuel. Preheat can impact instability growth rates in the ablation front and at the fuel–ablator interface. Monitoring the hohlraum x-ray spectrum throughout the implosion is, therefore, critical; for this purpose, a Multilayer Mirror (MLM) with flat response in the 2–4 keV range has been installed in the NIF 37° Dante calorimeter. Precision engineering and x-ray calibration of components mean the channel will report 2–4 keV spectral power with an uncertainty of ±8.7%.

Rubery, M. S. (ORCID:0000000344152818)↗

A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Using tabulated NLTE data for Hohlraum simulations

Non-local thermodyamic equilibrium (NLTE) atomic kinetics is necessary in inertial confinement fusion Hohlraum simulations for adequately modeling high-Z walls and dopants but is computationally very expensive. We present here an approach for tabulating NLTE material data in an economical manner. Material properties for an arbitrary radiation field are provided through tabulated data for a limited set of radiation fields plus derivatives with respect to components of those radiation fields. We have implemented this method in a radiation-hydrodynamics code and compare Hohlraum simulations done with inline NLTE calculations with those done with tables constructed from the same atomic data. The results demonstrate that NLTE tables can replace inline calculations in Hohlraum simulations without a significant loss of accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding the fusion yield dependencies in OMEGA DT-layered implosion experiments using a physics-based statistical mapping model

Improving the performance of inertial confinement fusion implosions requires physics models that can accurately predict the response to changes in the experimental inputs. Good predictive capability has been demonstrated for the fusion yield using a statistical mapping of simulated outcomes to experimental data [Gopalaswamy et al., Nature 565(771), 581–586 (2019)]. In this paper, a physics-based statistical mapping approach is used to extract and quantify all the major sources of degradation of fusion yield for direct-drive implosions on the OMEGA laser. Here, the yield is found to be dependent on the age of the deuterium tritium fill, the ℓ = 1 asymmetry in the implosion core, the laser beam-to-target size ratio, and parameters related to the hydrodynamic stability. A controlled set of experiments were carried out where only the target fill age was varied while keeping all other parameters constant. The measurements were found to be in excellent agreement with the fill age dependency inferred using the mapping model. In addition, a new implosion design was created, guided by the statistical mapping model by optimizing the trade-offs between increased laser energy coupling at larger target size and the degradations caused by the laser beam-to-target size ratio and hydrodynamic instabilities. When experimentally performed, an increased fusion yield was demonstrated in targets with larger diameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactive co-sputtering of ternary Au–Ta–O films with tunable electrical resistivity

Heavy-metal-based films with high electrical resistivity are needed for hohlraums for magnetically-assisted inertial confinement fusion. Here, we study ternary Au-Ta-O films deposited by reactive direct-current magnetron co-sputtering from elemental Au and Ta targets in an oxygen containing atmosphere. By varying O content, the electrical resistivity of films can be tuned in a wide range of ~ 100 - 40,000 μΩ cm. With increasing O content, a drastic increase in resistivity occurs at ~ 45 at.% of O, separating regimes with two different dominant conduction mechanisms attributed to metallic conduction through the Au-Ta alloy matrix (for ≲ 45 at.% of O) and tunneling across insulating Ta 2 O 5 layers separating conducting islands (for ≳ 45 at.% of O). Post-deposition annealing at 300 °C leads to the segregation of Au into ~ 50-nm islands, sharply decreasing the resistivity for films with ≳ 45 at.% of O but not for the metal-like films with lower O content.

36 MATERIALS SCIENCE↗