Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Homogenization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Computational simulation of a 100 kW dual circulating fluidized bed reactor processing coal by chemical looping with oxygen uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a promising carbon capture technology that utilizes two interconnected fluidized-bed reactors to separate oxygen from air using a metal oxide, and then to use that oxygen to combust fuel in a nitrogen-free environment. CLOU is particularly well suited for solid fuels such as coal since released O 2 will readily combust with solid char. This study presents simulations of the University of Utah's dual fluidized bed chemical looping process development unit (PDU) operating as a CLOU system at 100 kW th , using CPFD Software's Barracuda-VR™ CFD modeling program. A full 3D model of the PDU was used including both reactors, as well as loop seals and cyclone separators. Hydrodynamic settings and the drag model are based on previous cold-flow validation experiments. Mechanisms describing CLOU reaction kinetics for cuprous oxide oxidation in the air reactor and cupric oxide reduction in the fuel reactor were adapted from previously completed experimental work. Coal char kinetics were based on the carbon-hydrogen-nitrogen-oxygen-sulfur, CHNOS, method. Submodels for devolatilization, gasification, and homogenous gas-phase reactions used relationships from the literature. Results predict volatile burnout almost immediately, though coal combustion continues into the upper portions of the fuel reactor and cyclone. Lastly, nitrogen gas leakage into the fuel reactor is shown to be mostly carryover from the air reactor

42 ENGINEERING↗

Corrosion resistance of functionally graded TiN/Ti coatings for proton exchange membrane fuel cells

Bipolar Plates (BPP) are important components of proton exchange membrane fuel cell (PEMFC) stacks. In the development of innovative fuel cell designs, it is advantageous to use aluminum for these applications, however, this material lacks the necessary corrosion resistance. Since the performance of PEMFC stacks depends on BPP properties, in particular, corrosion resistance, depositing titanium nitride (TiN) thin films onto aluminum substrates may improve their efficiency and durability. Present work focuses on improving corrosion resistance and hydrophobicity of TiN/Ti by using N graded films deposited onto aluminum substrates (AA-1100) by grid-assisted magnetron sputtering (GAMS). Electrochemical impedance spectroscopy (EIS) with potentiodynamic and potentiostatic polarization are used to investigate the performance of the substrate/film system at room temperature and 70 oC, thus simulating a prototypic PEMFC electrolyte environment. Electrochemical test results showed that graded TiN films improved corrosion resistance when compared with both the homogeneous films and the AA1100 uncoated substrate. Furthermore, contact angle results reveal improved hydrophobicity for both homogeneous and graded TiN coatings when compared with the AA1100 substrate.

25 ENERGY STORAGE↗

FEM modeling of plastic flow and strain-induced phase transformation in BN under high pressure and large shear in a rotational diamond anvil cell

In this study, combined three-dimensional plastic flow and strain-induced phase transformation (PT) in boron nitride (BN) under high pressure and large shear in a rotational diamond anvil cell (rotational DAC or RDAC) are investigated. Geometrically nonlinear frameworks including finite elastic, transformational, and plastic deformations and finite element method (FEM) are utilized. Quantitative information is obtained on the evolutions of the stress tensor, plastic strain, volume fraction of phases in the entire sample, and slip-cohesion transitions, all during torsion under a fixed compressive load in RDAC. The effects of the applied compressive stress and the sample radius on PT and plastic flow are discussed. In comparison with DAC, the same amount of the high-pressure phase can be obtained at a much lower pressure in RDAC, which reduces the required force and the risk of diamond fracture. Also, RDAC has a potential to complete PT during torsion under pressure close to the minimum possible. A quasi-homogeneous pressure can be obtained in a transforming sample in RDAC under a proper choice of properties and parameters of a gasket. A number of experimental phenomena, including the pressure self-multiplication and quasi-homogeneous pressures in DAC and RDAC, are reproduced and interpreted. Finally, the simulation results provide a significant insight into coupled PTs and plastic flow in material in RDAC, and are important for the optimum design of experiments and the extraction of material parameters for PT, as well as for the optimization and control of PTs by the variation of various parameters.

36 MATERIALS SCIENCE↗

Multiscale modeling of twinning and detwinning behavior of HCP polycrystals

A multiscale scheme is presented here to capture the twinning and detwinning mechanisms during cyclic loading of HCP polycrystals. In the current framework, the crystal plasticity finite element (CPFE) method is employed at the microstructural scale. The response of twinned regions at a material point is calculated using a novel homogenization scheme via a Taylor-type model. The homogenized behavior is then used in the CPFE to obtain the response of a polycrystal. An efficient rate-independent crystal plasticity model that has been incorporated into the open source PRISMS-Plasticity software is introduced here to capture the response of the twinned region. Accordingly, the corresponding algorithmic tangent modulus is derived. Finally, this multiscale scheme is validated against data available for the cyclic response of Mg alloy ZK60A. The results show that the multiscale model can capture the key elements of the sample response observed during the experiment.

36 MATERIALS SCIENCE↗

Helical Tomotherapy Planning for Left-Sided Breast Cancer Patients With Positive Lymph Nodes: Comparison to Conventional Multiport Breast Technique

Purpose: To evaluate the feasibility of using helical tomotherapy for locally advanced left-sided breast cancer. Methods and Materials: Treatment plans were generated for 10 left-sided breast cancer patients with positive lymph nodes comparing a multiport breast (three-dimensional) technique with the tomotherapy treatment planning system. The planning target volumes, including the chest wall/breast, supraclavicular, axillary, and internal mammary lymph nodes, were contoured. The treatment plans were generated on the tomotherapy treatment planning system to deliver 50.4 Gy to the planning target volume. To spare the contralateral tissues, directional blocking was applied to the right breast and right lung. The optimization goals were to protect the lungs, heart, and right breast. Results: The tomotherapy plans increased the minimal dose to the planning target volume (minimal dose received by 99% of target volume = 46.2 {+-} 1.3 Gy vs. 27.9 {+-} 17.1 Gy) while improving the dose homogeneity (dose difference between the minimal dose received by 5% and 95% of the planning target volume = 7.5 {+-} 1.8 Gy vs. 37.5 {+-} 26.9 Gy). The mean percentage of the left lung volume receiving {>=}20 Gy in the tomotherapy plans decreased from 32.6% {+-} 4.1% to 17.6% {+-} 3.5%, while restricting the right-lung mean dose to <5 Gy. However, the mean percentage of volume receiving {>=}5 Gy for the total lung increased from 25.2% {+-} 4.2% for the three-dimensional technique to 46.9% {+-} 8.4% for the tomotherapy plan. The mean volume receiving {>=}35 Gy for the heart decreased from 5.6% {+-} 4.8% to 2.2% {+-} 1.5% in the tomotherapy plans. However, the mean heart dose for tomotherapy delivery increased from 7.5 {+-} 3.4 Gy to 12.2 {+-} 1.8 Gy. Conclusion: The tomotherapy plans provided better dose conformity and homogeneity than did the three-dimensional plans for treatment of left-sided breast tumors with regional lymph node involvement, while allowing greater sparing of the heart and left lung from doses associated with increased complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Intensity-Modulated Arc Therapy Vs. Conventional IMRT in Head-and-Neck Cancer: A Comparative Planning and Dosimetric Study

Purpose: Volumetric intensity-modulated arc therapy (RA) allows for rapid delivery of highly conformal dose distributions. In this study, planning and dosimetry of RA were compared with conventional intensity-modulated radiation therapy (IMRT) plans of head-and-neck cancer patients. Materials and Methods: Computed tomography scans of 12 patients who had completed IMRT for advanced tumors of the naso-, oro- and hypopharynx were replanned using RA using either one or two arcs. Calculated doses to planning target volume (PTV) and organs at risk (OAR) were compared between IMRT and RA plans. Dose distributions for single arc (n = 8) and double arc (n = 4) plans were verified using film dosimetry in three to five coronal planes using a quality assurance phantom. Results: RA plans allowed for a mean reduction in number of monitor units (MU) by nearly 60%, relative to seven field sliding window IMRT plans. RA plans achieved similar sparing of all OAR as IMRT. Double arc RA provided the best dose homogeneity to PTV with a lower standard deviation of PTV dose (1.4 Gy), vs. single arc plans (2.0 Gy) and IMRT (1.7 Gy). Film measurements showed good correspondence with calculated doses; the mean gamma value was 0.30 (double arc) and area of the film with a gamma exceeding 1 was 0.82%. Conclusions: RA is a fast, safe, and accurate technique that uses lower MUs than conventional IMRT. Double arc plans provided at least similar sparing of OAR and better PTV dose homogeneity than single arc or IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Device for Intravaginal Electronic Brachytherapy

Purpose: Postoperative intravaginal brachytherapy for endometrial carcinoma is usually performed with {sup 192}Ir high-dose rate (HDR) afterloading. A potential alternative is treatment with a broadband 50kV X-ray point source, the advantage being its low energy and the consequential steep dose gradient. The aim of this study was to create and evaluate a homogeneous cylindrical energy deposition around a newly designed vaginal applicator. Methods and Materials: To create constant isodose layers along the cylindrical plastic vaginal applicator, the source (INTRABEAM system) was moved in steps of 17-19.5 mm outward from the tip of the applicator. Irradiation for a predetermined time was performed at each position. The axial shift was established by a stepping mechanism that was mounted on a table support. The total dose/dose distribution was determined using film dosimetry (Gafchromic EBT) in a 'solid water' phantom. The films were evaluated with Mathematica 5.2 and OmniPro-I'mRT 1.6. The results (dose D0/D5/D10 in 0/5/10 mm tissue depth) were compared with an {sup 192}Ir HDR afterloading plan for multiple sampling points around the applicator. Results: Three different dose distributions with lengths of 3.9-7.3 cm were created. The irradiation time based on the delivery of 5/7 Gy to a 5 mm tissue depth was 19/26 min to 27/38 min. D0/D5/D10 was 150%/100%/67% for electronic brachytherapy and 140%/100%/74% for the afterloading technique. The deviation for repeated measurements in the phantom was <7%. Conclusions: It is possible to create a homogeneous cylindrical dose distribution, similar to {sup 192}Ir HDR afterloading, through the superimposition of multiple spherical dose distributions by stepping a kilovolt point source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Utility of the Modified Segmental Boost Technique for Treatment of the Pelvis and Inguinal Nodes

Purpose: Low-lying pelvic malignancies often require simultaneous radiation to pelvis and inguinal nodes. We previously reported improved homogeneity with the modified segmental boost technique (MSBT) compared to that with traditional methods, using phantom models. Here we report our institutional clinical experience with MSBT. Methods and Materials: MSBT patients from May 2001 to March 2007 were evaluated. Parameters analyzed included isocenter/multileaf collimation shifts, time per fraction (four fields), monitor units (MU)/fraction, femoral doses, maximal dose relative to body mass index, and inguinal node depth. In addition, a dosimetric comparison of the MSBT versus intensity modulated radiation therapy (IMRT) was conducted. Results: Of the 37 MSBT patients identified, 32 were evaluable. Port film adjustments were required in 6% of films. Median values for each analyzed parameter were as follows: MU/fraction, 298 (range, 226-348); delivery time, 4 minutes; inguinal depth, 4.5 cm; volume receiving 45 Gy (V45), 7%; V27.5, 87%; body mass index, 25 (range, 16.0-33.8). Inguinal dose was 100% in all cases; in-field inhomogeneity ranged from 111% to 118%. IMRT resulted in significantly decreased dose to normal tissue but required more time for treatment planning and a higher number of MUs (1,184 vs. 313 MU). Conclusions: In our clinical experience, the mono-isocentric MSBT provides a high degree of accuracy, improved homogeneity compared with traditional techniques, ease of simulation, treatment planning, treatment delivery, and acceptable femoral doses for pelvic/inguinal radiation fields requiring 45 to 50.4 Gy. In addition, the MSBT delivers a relatively uniform dose distribution throughout the treatment volume, despite varying body habitus. Clinical scenarios for the use of MSBT vs. intensity-modulated radiation therapy are discussed. To our knowledge, this is the first study reporting the utility of MSBT in the clinical setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involved-Node and Involved-Field Volumetric Modulated Arc vs. Fixed Beam Intensity-Modulated Radiotherapy for Female Patients With Early-Stage Supra-Diaphragmatic Hodgkin Lymphoma: A Comparative Planning Study

Purpose: A comparative treatment planning study was performed to compare volumetric-modulated arc (RA) to conventional intensity modulated (IMRT) for involved-field (IFRT) and involved-node (INRT) radiotherapy for Hodgkin lymphoma (HL). Methods and Materials: Plans for 10 early-stage HL female patients were computed for RA and IMRT. First, the planning target volume (PTV) coverage and organs at risk (OAR) dose deposition was assessed between the two modalities. Second, the OAR (lung, breast, heart, thyroid, and submandibular gland) dose-volume histograms were computed and compared for IFRT and INRT, respectively. Results: For IFRT and INRT, PTV coverage was equally homogeneous with both RA and IMRT. By and large, the OAR irradiation with IFRT planning was not significantly different between RA and IMRT. For INRT, doses computed for RA were, however, usually lower than those with IMRT, particularly so for the lung, breast, and thyroid. Regardless of RA and IMRT modalities, a significant 20-50% decrease of the OAR computed mean doses was observed with INRT when compared with IFRT (Breast D{sub Mean} 1.5 +- 1.1 vs. 2.6 +- 1.7 Gy, p < 0.01 and 1.6 +- 1.1 vs. 2.9 +- 1.9 Gy, p < 0.01 for RA and IMRT, respectively). Conclusions: RA and IMRT results in similar level of dose homogeneity. With INRT but not IFRT planning, the computed doses to the PTV and OAR were usually higher and lower with RA when compared to IMRT. Regardless of the treatment modality, INRT when compared with IFRT planning led to a significant decrease in OAR doses, particularly so for the breast and heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy Improves Dosimetry and Reduces Treatment Time Compared to Conventional Intensity-Modulated Radiotherapy for Locoregional Radiotherapy of Left-Sided Breast Cancer and Internal Mammary Nodes

Purpose: Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (cIMRT), in which an optimized three-dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to RapidArc (Varian Medical System). This study compared VMAT with cIMRT and with conventional modified wide-tangent (MWT) techniques for locoregional radiotherapy for left-sided breast cancer, including internal mammary nodes. Methods and Materials: Therapy for 5 patients previously treated with 50 Gy/25 fractions using nine-field cIMRT was replanned with VMAT and MWT. Comparative endpoints were planning target volume (PTV) dose homogeneity, doses to surrounding structures, number of monitor units, and treatment delivery time. Results: For VMAT, two 190 deg. arcs with 2-cm overlapping jaws were required to optimize over the large treatment volumes. Treatment plans generated using VMAT optimization resulted in PTV homogeneity similar to that of cIMRT and MWT. The average heart volumes receiving >30 Gy for VMAT, cIMRT, and MWT were 2.6% +- 0.7%, 3.5% +- 0.8%, and 16.4% +- 4.3%, respectively, and the average ipsilateral lung volumes receiving >20 Gy were 16.9% +- 1.1%, 17.3% +- 0.9%, and 37.3% +- 7.2%, respectively. The average mean dose to the contralateral medial breast was 3.2 +- 0.6 Gy for VMAT, 4.3 +- 0.4 Gy for cIMRT, and 4.4 +- 4.7 Gy for MWT. The healthy tissue volume percentages receiving 5 Gy were significantly larger with VMAT (33.1% +- 2.1%) and IMRT (45.3% +- 3.1%) than with MWT (19.4% +- 3.7%). VMAT reduced the number of monitor units by 30% and the treatment time by 55% compared with cIMRT. Conclusions: VMAT achieved similar PTV coverage and sparing of organs at risk, with fewer monitor units and shorter delivery time than cIMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Postmastectomy Treatment With Helical TomoTherapy

Purpose: To investigate the potential of helical tomotherapy for postmastectomy radiation therapy. Methods and Materials: By use of the TomoTherapy Hi-Art II treatment-planning system (TomoTherapy Inc., Madison, WI), helical tomotherapy dose plans were developed for 5 patients and compared with the mixed-beam (electron-photon) plans with which they had been treated. The TomoTherapy plans were evaluated by use of dose-volume quantities, tumor control probability, normal tissue complication probability (NTCP), and secondary cancer complication probability (SCCP). Results: The TomoTherapy plans showed better dose homogeneity in the planning treatment volume containing the chest wall and internal mammary nodes (p = 0.001) and eliminated the need for abutting fields. For the normal tissues, the TomoTherapy plans showed a smaller fractional volume receiving 20Gy or greater for the ipsilateral lung (p = 0.05), no change in NTCP for postradiation pneumonitis, increased SCCP for each lung and both lungs together (p < 0.02), no change in the volume of the heart receiving more than 15Gy, no change in NTCP for excess cardiac mortality, and a larger mean dose and SCCP in the contralateral breast (p < 0.001). For nonspecific tissues, the volume receiving between 5Gy and 25Gy and SCCP were both larger for the TomoTherapy plans (p < 0.01). Total SCCP was larger for the TomoTherapy plans (p = 0.001). Conclusions: Overall, the TomoTherapy plans had comparable tumor control probability and NTCP to the mixed-beam plans and increased SCCP. The TomoTherapy plans showed significantly greater dose homogeneity in the chest wall, which offers the potential for improved cosmesis after treatment. These factors have resulted in TomoTherapy often being the treatment of choice for postmastectomy radiation therapy in our clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accurate Automatic Delineation of Heterogeneous Functional Volumes in Positron Emission Tomography for Oncology Applications

Purpose: Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. Methods and Materials: Current state-of-the-art algorithms for functional volume segmentation use adaptive thresholding. We developed an approach called fuzzy locally adaptive Bayesian (FLAB), validated on homogeneous objects, and then improved it by allowing the use of up to three tumor classes for the delineation of inhomogeneous tumors (3-FLAB). Simulated and real tumors with histology data containing homogeneous and heterogeneous activity distributions were used to assess the algorithm's accuracy. Results: The new 3-FLAB algorithm is able to extract the overall tumor from the background tissues and delineate variable uptake regions within the tumors, with higher accuracy and robustness compared with adaptive threshold (T{sub bckg}) and fuzzy C-means (FCM). 3-FLAB performed with a mean classification error of less than 9% +- 8% on the simulated tumors, whereas binary-only implementation led to errors of 15% +- 11%. T{sub bckg} and FCM led to mean errors of 20% +- 12% and 17% +- 14%, respectively. 3-FLAB also led to more robust estimation of the maximum diameters of tumors with histology measurements, with <6% standard deviation, whereas binary FLAB, T{sub bckg} and FCM lead to 10%, 12%, and 13%, respectively. Conclusion: These encouraging results warrant further investigation in future studies that will investigate the impact of 3-FLAB in radiotherapy treatment planning, diagnosis, and therapy response evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience With Volumetric IMRT (RapidArc) for Intracranial Stereotactic Radiosurgery

Purpose: Initial experience with delivering frameless stereotactic radiotherapy (SRT) using volumetric intensity-modulated radiation therapy (IMRT) delivered with RapidArc is presented. Methods and Materials: Treatment details for 12 patients (14 targets) with a mean clinical target volume (CTV) of 12.8 {+-} 4.0 cm{sup 3} were examined. Dosimetric indices for conformality, homogeneity, and dose gradient were calculated and compared with published results for other frameless, intracranial SRT techniques, including CyberKnife, TomoTherapy, and static-beam IMRT. Statistics on setup and treatment times and per patient dose validations were examined. Results: Dose indices compared favorably with other techniques. Mean conformality, gradient, and homogeneity index values were 1.10 {+-} 0.11, 64.9 {+-} 14.1, 1.083 {+-} 0.026, respectively. Median treatment times were 4.8 {+-} 1.7 min. Conclusion: SRT using volumetric IMRT is a viable alternative to other techniques and enables short treatment times. This is anticipated to have a positive impact on radiobiological effect and for facilitating wider use of SRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hippocampal-Sparing Whole-Brain Radiotherapy: A 'How-To' Technique Using Helical Tomotherapy and Linear Accelerator-Based Intensity-Modulated Radiotherapy

Purpose: Sparing the hippocampus during cranial irradiation poses important technical challenges with respect to contouring and treatment planning. Herein we report our preliminary experience with whole-brain radiotherapy using hippocampal sparing for patients with brain metastases. Methods and Materials: Five anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. The hippocampus was contoured, and hippocampal avoidance regions were created using a 5-mm volumetric expansion around the hippocampus. Helical tomotherapy and linear accelerator (LINAC)-based intensity-modulated radiotherapy (IMRT) treatment plans were generated for a prescription dose of 30 Gy in 10 fractions. Results: On average, the hippocampal avoidance volume was 3.3 cm{sup 3}, occupying 2.1% of the whole-brain planned target volume. Helical tomotherapy spared the hippocampus, with a median dose of 5.5 Gy and maximum dose of 12.8 Gy. LINAC-based IMRT spared the hippocampus, with a median dose of 7.8 Gy and maximum dose of 15.3 Gy. On a per-fraction basis, mean dose to the hippocampus (normalized to 2-Gy fractions) was reduced by 87% to 0.49 Gy{sub 2} using helical tomotherapy and by 81% to 0.73 Gy{sub 2} using LINAC-based IMRT. Target coverage and homogeneity was acceptable with both IMRT modalities, with differences largely attributed to more rapid dose fall-off with helical tomotherapy. Conclusion: Modern IMRT techniques allow for sparing of the hippocampus with acceptable target coverage and homogeneity. Based on compelling preclinical evidence, a Phase II cooperative group trial has been developed to test the postulated neurocognitive benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P<.001; r = 0.44, P=.03, respectively) and the medial and central contralateral breast (r = 0.73, P<.001; r = 0.88, P<.001, respectively). With 3D-CRT there was a significant correlation in the medial and lateral ipsilateral breast (r = 0.45, P=.03; r = 0.68, P<.001, respectively); the medial and central contralateral breast (r = 0.62, P=.001; r = 0.86, P<.001, respectively); and the mid neck (r = 0.42, P=.04, respectively). On average, HT-calculated dose overestimated the measured dose by 14%; 3D-CRT underestimated the dose by 0.4%. There was a borderline association between highest measured skin dose and moist desquamation (P=.05). Skin-sparing HT had greater skin homogeneity (homogeneity index of 1.39 vs 1.65, respectively; P=.005) than 3D-CRT plans. HT plans had a lower skin{sub V50} (1.4% vs 5.9%, respectively; P=.001) but higher skin{sub V40} and skin{sub V30} (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients receiving adjuvant breast RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hearing Outcomes After Stereotactic Radiosurgery for Unilateral Intracanalicular Vestibular Schwannomas: Implication of Transient Volume Expansion

Purpose: We evaluated the prognostic factors for hearing outcomes after stereotactic radiosurgery (SRS) for unilateral sporadic intracanalicular vestibular schwannomas (IC-VSs) as a clinical homogeneous group of VSs. Methods and Materials: Sixty consecutive patients with unilateral sporadic IC-VSs, defined as tumors in the internal acoustic canal, and serviceable hearing (Gardner-Roberson grade 1 or 2) were treated with SRS as an initial treatment. The mean tumor volume was 0.34 {+-} 0.03 cm{sup 3} (range, 0.03-1.00 cm{sup 3}), and the mean marginal dose was 12.2 {+-} 0.1 Gy (range, 11.5-13.0 Gy). The median follow-up duration was 62 months (range, 36-141 months). Results: The actuarial rates of serviceable hearing preservation were 70%, 63%, and 55% at 1, 2, and 5 years after SRS, respectively. In multivariate analysis, transient volume expansion of {>=}20% from initial tumor size was a statistically significant risk factor for loss of serviceable hearing and hearing deterioration (increase of pure tone average {>=}20 dB) (odds ratio = 7.638; 95% confidence interval, 2.317-25.181; P=.001 and odds ratio = 3.507; 95% confidence interval, 1.228-10.018; P=.019, respectively). The cochlear radiation dose did not reach statistical significance. Conclusions: Transient volume expansion after SRS for VSs seems to be correlated with hearing deterioration when defined properly in a clinically homogeneous group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗