Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A Case for Electron-Astrophysics

Abstract The smallest characteristic scales, at which electron dynamics determines the plasma behaviour, are the next frontier in space and astrophysical plasma research. The analysis of astrophysical processes at these scales lies at the heart of the research theme of electron-astrophysics. Electron scales are the ultimate bottleneck for dissipation of plasma turbulence, which is a fundamental process not understood in the electron-kinetic regime. In addition, plasma electrons often play an important role for the spatial transfer of thermal energy due to the high heat flux associated with their velocity distribution. The regulation of this electron heat flux is likewise not understood. By focussing on these and other fundamental electron processes, the research theme of electron-astrophysics links outstanding science questions of great importance to the fields of space physics, astrophysics, and laboratory plasma physics. In this White Paper, submitted to ESA in response to the Voyage 2050 call, we review a selection of these outstanding questions, discuss their importance, and present a roadmap for answering them through novel space-mission concepts.

79 ASTRONOMY AND ASTROPHYSICS↗

BRAHMS-Sensitive Bolometer Arrays for the SPICA Imaging Polarimetry

A high-sensitivity cryogenic sub-millimetre camera is planned for the SPICA space observatory. At the heart of this instrument, new all-silicon bolometer arrays integrate in pixel instrumental polarimetry capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Porous Media Characterization Using Minkowski Functionals: Theories, Applications and Future Directions

Porous materials are ubiquitous, from biological tissues (skin, cartilage, bones, heart tissue), to manufactured materials (paper, functional porous materials, batteries, drug delivery systems, diapers), to environmental materials (rocks, soils, plants). Because these materials are composed of multiple phases, the effects of flow, heat transfer, chemical reactions, and deformations including swelling and shrinking are more complex than that for a single phase such as a gas, liquid, or solid. The realization that porous materials, regardless of the application, have commonalities in modeling approaches, experimental methods, and numerical methods was the impetus of this journal, Transport in Porous Media (founded by Jacob Bear in 1986) and of the International Society for Porous Media (InterPore, interpore.org), which at its roots, originated in 2006. The growth of TIPM and of InterPore mirrors the explosive interest in porous media research that is now recognized as a field of research in and of itself. It is in the honor of InterPore’s 10th anniversary, celebrated at the InterPore 10th Annual Meeting and Jubilee in 2018 in New Orleans, USA, that this special issue was conceived.

Armstrong, Ryan T. (ORCID:0000000164317902)↗

Thermo-chemical Fluid Flow Simulation in Hot-Dip Galvanizing: The Evaluation of Dross Build-Up Formation

This paper presents a new computational framework to investigate the driving force for the formation of intermetallic dross particles in the zinc bath and dross build-up on the bath hardware. This is a major problem in continuous hot-dip galvanizing lines. The Computational Fluid Dynamics (CFD) model calculates the turbulent thermo-chemical flow conditions within the liquid melt. A detailed modeling of the steel strip–liquid interface enhances this approach, by means of a conjugated heat transfer calculation and a spatially resolved, temperature- and concentration-dependent iron dissolution and aluminum uptake. The heart of the computational framework is a thermodynamic model, which assesses the driving force for the formation or dissolution of dross particles in the bath and dross build-up on stationary and rotating equipment. The simulation results are validated with temperature and species depth profile measurements. The applicability of the CFD model is shown by investigating the locally resolved aluminum uptake and iron dissolution at the steel-strip surface, and the multi-physics conditions in the region near the roll. The novel approach of evaluating the thermodynamic driving force enables the assessment of the formation of dross build-up at the roll surface.

36 MATERIALS SCIENCE↗

The Onco-cardiologist Dilemma: to Implant, to Defer, or to Avoid Transcatheter Aortic Valve Replacement in Cancer Patients with Aortic Stenosis?

Purpose of Review: Aging is associated with an increased prevalence of both cancer and heart disease. The progression of aortic valve calcification to aortic stenosis may be accelerated by both cardiovascular risk factors and cancer treatments, such as radiotherapy with mediastinal involvement. Symptomatic aortic stenosis is occasionally diagnosed in cancer patients undergoing cardiovascular evaluation; likewise, cancer is often recognized during assessment preceding aortic valve interventions. In these complex cases, physicians face difficult treatment decisions. Due to a myriad of clinical presentations of cancer and valve disease, specific guidelines for this patient population are not currently in place. Management is currently based on clinical judgment, on an individual basis. Recent Findings: Patients with cancer in remission or with a favorable prognosis should be treated according to current cardiovascular guidelines. In these patients, aortic valve replacement can be performed either by surgery or transcatheter. Significant challenges arise in patients with active cancer, especially those receiving anti-cancer treatment. Recent data suggests that these patients can be offered aortic valve replacement, with a trend of favoring the transcatheter route in order to minimize perioperative risk and complications associated with major surgery. Patients with advanced cancer and severe aortic stenosis should be offered palliative care and can benefit from aortic balloon valvuloplasty if indicated. Modern cancer treatments associated with improved long-term prognosis may allow the appropriate cure of aortic stenosis. Summary: We discuss the protocol, outcomes, and evolving recommendations of aortic valve replacement in cancer patients with aortic stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Strategies for Evaluating Low-Flow, Low-Gradient Aortic Stenosis with Reduced and Preserved Left Ventricular Ejection Fraction

Purpose of Review: Aortic stenosis (AS) is one of the most common valvular heart diseases, and aortic valve replacement (AVR) provides both symptomatic and survival benefit in symptomatic severe AS patients. The purpose of this review is to discuss low-flow low-gradient AS which is still a challenging diagnostic entity. Recent Findings: Thirty–forty percent of patients with AS have low flow which makes it difficult to differentiate truly severe AS that benefits from AVR compared to pseudo-severe AS which is currently managed conservatively. Patients with low-flow low-gradient AS (LF-LG AS) include those with reduced left ventricular systolic function (classical LF-LG AS) and those with preserved left ventricular systolic function (paradoxical LF-LG AS). Low-dose dobutamine stress echocardiography (DSE) helps to identify truly severe stenosis in patients with classical LF-LG AS. Aortic valve calcium scoring with multidetector computed tomography plays a major role in patients with paradoxical LF-LG AS and also among classical LF-LG AS patients who have reduced contractile reserve on DSE. Summary: This article will provide an overview of imaging strategies for evaluating LF-LG AS with reduced and preserved left ventricular ejection fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apela Promotes Cardiomyocyte Differentiation from Transgenic Human Embryonic Stem Cell Lines

Although embryonic stem (ES) cells (ESCs) may be a promising donor source for the repair of infarcted or ischemic heart tissues, their successful application in regenerative medicine has been hampered by difficulties in enriching, identifying, and selecting cardiomyocytes from the differentiating cells. We established transgenic human ES cell lines by transcriptional control of the α-cardiac myosin heavy chain (α-MHC) promoter driving green fluorescent protein (GFP) expression. Differentiated GFP-expressing cells display the characteristics of cardiomyocytes (CMs). Apela, a recently identified short peptide, up-regulated the expression of the cardiac-restricted transcription factors Tbx5 and GATA4 as well as differentiated the cardiomyocyte markers α-MHC and β-MHC. Flow cytometric analysis showed that apela increased the percentage of GFP-expressing cells in the beating foci of the embryoid bodies. The percentage of cardiac troponin T (TNT)-positive cells and the protein expression of TNT were increased in the ES cell-derived CMs with apela treatment. Functionally, the contractile frequency of the ES-derived CMs responded appropriately to the vasoactive drugs isoprenaline and carbachol. Our work presented a protocol for specially labelling and enriching CMs by combining transgenic human ES cell lines and exogenous growth factor treatment.

60 APPLIED LIFE SCIENCES↗

Prognostic value of left ventricular dyssynchrony evaluated by gated myocardial perfusion imaging in patients with chronic kidney disease and normal perfusion defect scores

Background: This study aimed to investigate whether indices of left ventricular (LV) dyssynchrony by gated myocardial perfusion SPECT (GMPS) could be useful to predict prognosis in chronic kidney disease (CKD) patients with normal perfusion defect scores. Methods: One hundred and sixty-seven CKD patients with normal perfusion defect scores on adenosine-stress {sup 201}Tl GMPS and no previous history of overt heart diseases were enrolled. Phase standard deviation (PSD) and bandwidth (BW) were automatically calculated from GMPS. The major adverse cardiac events (MACEs) for a mean of 560 days were defined as sudden cardiac death, fatal arrhythmias, and acute coronary syndrome requiring urgent coronary revascularization. Patients were divided into two groups according to the presence or absence of MACEs. Results: The MACEs occurred in 12 patients (7.1%). Patients who experienced MACEs showed significantly higher PSD and wider BW than those who did not. In the Kaplan-Meier event-free survival analysis, cardiac event rate was significantly higher in the high-PSD and wide-BW group (n = 81) than in the low-PSD and narrow-BW group (n = 71) (P = .002). The multivariate regression analysis revealed that the PSD was associated with MACEs (odds ratio 1.33, 95% confidence interval 1.05-1.69, P = .01). Conclusion: The LV dyssynchrony indices from GMPS may be novel prognostic predictors in CKD patients with normal perfusion defect scores.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume-based glucose metabolic analysis of FDG PET/CT: The optimum threshold and conditions to suppress physiological myocardial uptake

Objective: FDG PET/CT plays a significant role in the diagnosis of inflammatory heart diseases and cardiac tumors. We attempted to determine the optimal FDG uptake threshold for volume-based analyses and to evaluate the relationship between the myocardial physiological uptake volume in FDG PET and several clinical factors. Methods: A total of 190 patients were retrospectively analyzed. The cardiac metabolic volume (CMV) was defined as a volume within the boundary determined by a threshold (SUVmean of blood pool × 1.5). Results: The SUVmean of the blood pool measured in the descending aorta (DA) (r = 0.86, intraclass correlation coefficient [ICC] = 0.93, P < 0.0001) and that in the left ventricle (LV) cavity (r = 0.87, ICC = 0.90, P < 0.0001) showed high inter-operator reproducibility. However, the SUVmean in the LV cavity showed a significant correlation with the CMV (P = 0.0002, r = 0.26). The CMV in the patients who fasted < 18 hours were significantly higher (49.7 ± 73.2 vs. 18.0 ± 53.8 mL, P = 0.0013) compared to the patients with > 18-hour fasting. The multivariate analysis demonstrated that only the fasting period > 18 hours was independently associated with CMV = 0. Conclusion: Our findings revealed that the DA is suitable to decide the threshold for the volume-based analysis. The fasting time was significantly associated with the cardiac FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nutrition, risk factors, prevention, and imaging: The 2018 Mario Verani Lecture

Heart disease has been the leading cause of death in the United States since 1918. Cardiac mortality rates have dramatically decreased in this era of advanced medical and interventional therapies. However, this has been aptly described as “mopping up the floor instead of turning off the faucet.” With this recognition, prevention in cardiology is poised to become a central focus. Within prevention, dietary intervention is recognized as the single largest opportunity for improved cardiovascular outcomes, including improvement or elimination of cardiac risk factors, prevention of myocardial infarction, stroke and cardiovascular death, and reduction of plaque burden and myocardial ischemia. Cardiac imaging, particularly nuclear perfusion and coronary computed tomographic angiography, plays a critical role in early diagnosis and serial evaluation of myocardial ischemia and coronary artery disease. These techniques have the potential to help refine research protocols and evaluate their success by providing intermediate markers of improved myocardial blood flow and coronary plaque morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A need to reduce premature CV mortality in the developing world: How could appropriate use of non-invasive imaging help?

We discuss premature deaths due to coronary heart disease (CHD) in developing countries and the importance of a comprehensive approach, involving clinical judgement, prevention, appropriate use of technology to diagnose and guide CHD treatment. Healthcare policies and levels of knowledge vary tremendously resulting heterogeneous utilization of diagnostic strategies and treatments worldwide. Many countries with high mortality have low utilization of non-invasive cardiac imaging. Appropriate use coupled with guideline-based management could help to improve care in the developing world and potentially result in better life expectancy already experienced by most high-income countries. In a scenario of increasing costs, a rational utilization of resources is imperative for all nations. A stepwise approach to suspected CHD is necessary, starting from good judgement, adding tests only as needed, preferably filtering patients who might benefit from advanced imaging. In stable patients, non-invasive tests should be used as filters to invasive procedure, preventing stable patients from undergoing revascularizations of questionable benefit. In this article, we review the relative role of exercise testing, myocardial perfusion imaging, and coronary computed tomography angiography to evaluate CHD and how these can be utilized as ways to help guide management that could impact premature mortality in developing nations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid anatomo-functional imaging of coronary artery disease: Beneficial irrespective of its core components

Coronary artery disease (CAD) is the most common and important cause of ischemic heart disease, with major implications on global morbidity and mortality. Non-invasive testing is crucial in the diagnostic and prognostic work-up of patients with or at risk of CAD, and also to guide decision making in terms of pharmacologic and revascularization therapy. The traditional paradigm is to view anatomic (i.e., coronary computed tomography) and functional imaging (e.g., myocardial perfusion scintigraphy) tests as opposing alternatives. Such approach is too reductionist and does not capitalize on the strengths of each type of test while risking to overlook the inherent limitations. The combination of anatomic and functional tests in a logic of hybrid imaging holds the promise of overcoming the limitations inherent to anatomic and functional testing, enabling more accurate diagnosis, prognosis, and guidance for revascularization in patients with CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of regadenoson-induced myocardial creep on dynamic Rubidium-82 PET myocardial blood flow quantification

Background: Repositioning of the heart during myocardial perfusion imaging (MPI) using Rubidium-82 (Rb-82) PET may occur when using regadenoson. Our aim was to determine the prevalence and the effect of correcting for this myocardial creep on myocardial blood flow (MBF) quantification. Methods: We retrospectively included 119 consecutive patients who underwent dynamic rest- and regadenoson-induced stress MPI using Rb-82 PET. The presence of myocardial creep was visually assessed in the dynamic stress PET series by identifying differences between the automatically drawn myocardium contour and the activity. Uncorrected and corrected stress MBFs were compared for the three vascular territories (LAD, LCX, and RCA) and for the whole myocardium. Results: Myocardial creep was observed in 52% of the patients during stress. Mean MBF values decreased after correction in the RCA from 4.0 to 2.7 mL/min/g (P < 0.001), in the whole myocardium from 2.7 to 2.6 mL/min/g (P = 0.01), and increased in the LAD from 2.5 to 2.6 mL/min/g (P = 0.03) and remained comparable in the LCX (P = 0.3). Conclusions: Myocardial creep is a frequent phenomenon when performing regadenoson-induced stress Rb-82 PET and has a significant impact on MBF values, especially in the RCA territory. As this may hamper diagnostic accuracy, myocardial creep correction seems necessary for reliable quantification. [French] French Abstract: Contexte: Un repositionnement du cœur lors de l’imagerie de perfusion myocardique (MPI) à l’aide de la TEP au rubidium-82 (RB-82) peut survenir lors de l’utilisation du regadenoson. Notre objectif était de déterminer la prévalence et l’effet de la correction du fluage sur la quantification du débit sanguin myocardique (DSM). Méthodes: dans cette étude rétrospective, nous avons inclus 119 patients consécutifs ayant beneficié d’un examen au repos suivi d’un stress pharamacologique au régadénoson en utilisant le RB-82. La présence de fluage myocardique a été évaluée visuellement sur les images TEP de stress dynamique en utilisant les différences entre les contours automatiques et les images myocardiques. Les DSM de stress non corrigés et corrigés ont été comparés pour les trois territoires vasculaires (coronaire gauche-CG, la circonflexe-CX, et coronaire droite-CD) et pour l’ensemble du myocarde. Résultats: le fluage myocardique a été observé chez 52% des patients sur les examens de stress. Les valeurs moyennes de DSM ont diminué après correction dans le territoire de la CD de 4,0 à 2,7 mL/min/g (p < 0,001), dans le myocarde entier de 2,7 à 2,6 mL/min/g (p = 0,01) et augmenté dans le territoire de la CG de 2,5 à 2,6 mL/min/g (p = 0,03) et est resté comparable dans le territoire de la CX (p = 0,3). Conclusions: le fluage myocardique est un phénomène fréquent lors de l’exécution du stress phramacologique au régadénoson à l’aide du RB-82. Il a un impact significatif sur les valeurs de DSM, en particulier dans le territoire de la CD. La correction du fluage myocardique semble donc nécessaire pour une quantification fiable des flux coronariens. [Spanish] Spanish Abstract: Antecedentes: El movimiento del corazón durante la imagen de perfusión miocárdica usando Rubidio-82 (Rb-82) PET puede ocurrir cuando se usa regadenosón. Nuestro enfoque fue determinar la prevalencia y efecto de la corrección de este Artefacto de movimiento en la cuantificación del flujo sanguíneo miocárdico. Métodos: Se incluyeron de forma retrospectiva 119 pacientes que se realizaron estudio dinámico en reposo y estudio de perfusión miocárdica en estrés inducido por regadenosón usando Rb-82 PET. La presencia de el artefacto de movimiento fue evaluado visualmente en el estudio en serie de PET dinámico en estrés identificando las diferencias entre el contorno miocárdico dibujado automáticamente y la actividad. La perfusión miocárdica en estrés corregida y sin corregir se compararon para los tres territorios vasculares (Descendente Anterior, Circunfleja, Coronaria Derecha) y para todo el miocardio. Resultados: El artefacto de movimiento miocárdico se observo en un 52% de los pacientes durante el estrés. El promedio de los valores de flujo sanguíneo miocárdico disminuyen después de la corrección en la arteria coronaria derecha de 4.0 a 2.7 ml/min/g (p < 0.001), en todo el miocardio de 2.7 a 2.6 mL/min/g (p = 0.01) y un aumento en la arteria descendente anterior de 2.5 a 2.6 mL/min/g (p = 0.03) y se mantuvo comparable en la arteria circunfleja (p = 0.3). Conclusiones: El artefacto de movimiento miocárdico es un fenómeno frecuente cuando se realiza la prueba de estrés inducido con regadenosón Rb-82 PET y tiene un impacto significativo en los valores de flujo sanguíneo miocárdico, principalmente en el territorio de la coronaria derecha. Esto puede disminuir la precisión diagnostica, la corección del artefacto de movimiento es necesario para una cuantificación confiable. [Chinese] Chinese Abstract: 背景: 铷-82 (Rb-82) PET心肌灌注成像 (MPI) 过程在使用类伽腺苷时可能会发生心脏重定位。我们的目的是确定心肌蠕动 (myocardial creep) 校正对心肌血流灌注定量的影响及其普遍性。 方法: 我们连续回顾了119 名使用 Rb-82 PET 进行动态的静息与类伽腺苷负荷MPI的患者。通过识别自动绘制的心肌轮廓和心肌活动之间的差异, 在动态负荷 PET 检查中肉眼评估心肌蠕动的存在。分别在已校正和未校正的负荷 MBF上, 对三个血管区域 (LAD, LCX, RCA) 和整个心肌灌注情况进行比较。 结果: 负荷检查中, 52% 的患者观察到心肌蠕动。 RCA 校正后平均MBF值从4.0降至 2.7 mL / min / g (p <0.001), 整个心肌从 2.7降至 2.6 mL / min / g (p = 0.01) , LAD 从 2.5 升至 2.6mL / min / g (p = 0.03) 并且在LCX中保持不变 (p = 0.3) 。 结论: 类伽腺苷负荷 Rb-82 PET 检查中, 心肌蠕动是一种常见的现象, 并且对 MBF 值有显著影响, 特别在 RCA 区域。这可能妨碍诊断准确性, 因此心肌蠕动校正是准确定量的必要条件。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

No need for frame-wise attenuation correction in dynamic Rubidium-82 PET for myocardial blood flow quantification

Background: Regadenoson-induced stress causes a repositioning of the heart, myocardial creep, in half of the patients undergoing Rubidium-82 (Rb-82) positron emission tomography (PET). As a result, misalignment of dynamic PET and computer tomography (CT) may occur, possibly affecting CT-based attenuation correction (AC) and thereby PET-based myocardial blood flow (MBF) quantification. Our aim was to determine the need for frame-wise PET-CT AC to obtain reliable MBF measurements. Methods: 31 Out of 64 consecutive patients had myocardial creep during regadenoson-induced stress Rb-82 PET-CT and were included. Prior to PET image reconstruction, we applied two AC methods; single PET-CT alignment and frame-wise alignment in which PET time-frames with myocardial creep were individually co-registered with CT. The PET-CT misalignment was then quantified and MBFs for the three vascular territories and whole myocardium were calculated and compared between both methods. Results: The magnitude of misalignment due to myocardial creep was 13.8 ± 4.5 mm in caudal-cranial direction, 1.8 ± 2.1 mm in medial-lateral and 2.5 ± 1.8 mm in anterior-posterior direction. Frame-wise PET-CT registration did not result in different MBF measurements (P ≥ .07) and the magnitude of misalignment and MBF differences did not correlate (P ≥ .58). Conclusion: There is no need for frame-wise AC in dynamic Rb-82 PET for MBF quantification. Single alignment seems sufficient in patients with myocardial creep.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comorbid conditions in individuals assessed by SPECT: Study of a reference cardiology center in Mexico City

Background: There is an increasing prevalence of comorbidities in patients with ischemic heart disease (IHD) in developing countries. The aim of this work is to assess the prevalence of comorbidities and associated factors for IHD among patients at a reference cardiology center. Design and Methods: This was a cross-sectional study. A complete clinical history which focused on the main comorbidities, previous myocardial infarction, and the main reason of referral was assessed. A single-photon emission computed tomography (SPECT) myocardial perfusion study (MPS) with two protocols was performed. Results: We included 1998 patients, 64.2% male, median age 63 (I.R.: 56–71) years. 1514 (75.8%) subjects had at least one associated comorbidity. The main comorbidity was diabetes (T2D) (772: 38.6%), followed by systemic hypertension (737: 36.9%), smoking (518: 25.9%), and dyslipidemia (517: 25.9%). 806 (40.3%) had histories of previous myocardial infarctions. The main cause of referral was angina (923: 46.2%). We identified 1330 (66.5%) abnormal MPS. 460 (23%) had ischemia, 292 (14.6%) infarction, and 578 (28.9%) ischemia and infarction. Conclusion: An increased prevalence of comorbidities was found in patients who were studied in the Nuclear Cardiology Department (NCD): most of them had traditional risk factors attributable to myocardial infarction. A great percentage were newly diagnosed with both ischemia and infarction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Electrode Geometry on the Classification Performance of Rapid Evaporative Ionization Mass Spectrometric (REIMS) Bacterial Identification

The recently developed automated, high-throughput monopolar REIMS platform is suited for the identification of clinically important microorganisms. Although already comparable to the previously reported bipolar forceps method, optimization of the geometry of monopolar electrodes, at the heart of the system, holds the most scope for further improvements to be made. For this, sharp tip and round shaped electrodes were optimized to maximize species-level classification accuracy. Following optimization of the distance between the sample contact point and tube inlet with the sharp tip electrodes, the overall cross-validation accuracy improved from 77% to 93% in negative and from 33% to 63% in positive ion detection modes, compared with the original 4 mm distance electrode. As an alternative geometry, round tube shaped electrodes were developed. Geometry optimization of these included hole size, number, and position, which were also required to prevent plate pick-up due to vacuum formation. Additional features, namely a metal “X”-shaped insert and a pin in the middle were included to increase the contact surface with a microbial biomass to maximize aerosol production. Following optimization, cross-validation scores showed improvement in classification accuracy from 77% to 93% in negative and from 33% to 91% in positive ion detection modes. Supervised models were also built, and after the leave 20% out cross-validation, the overall classification accuracy was 98.5% in negative and 99% in positive ion detection modes. This suggests that the new generation of monopolar REIMS electrodes could provide substantially improved species level identification accuracies in both polarity detection modes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Mass Spectrometer in Every Fume Hood

Since their inception, mass spectrometers have played a pivotal role in the direction and application of synthetic chemical research. The ability to develop new instrumentation to solve current analytical challenges in this area has always been at the heart of mass spectrometry, although progress has been slow at times. Herein, we briefly review the history of how mass spectrometry has been used to approach challenges in organic chemistry, how new developments in portable instrumentation and ambient ionization have been used to open novel areas of research, and how current techniques have the ability to expand on our knowledge of synthetic mechanisms and kinetics. Lastly, we discuss the relative paucity of work done in recent years to embrace the concept of improving benchtop synthetic chemistry with mass spectrometry, the disconnect between applications and fundamentals within these studies, and what hurdles still need to be overcome. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile healing of cracks in organic–inorganic halide perovskite thin films

Organic-inorganic halide perovskite (OIHP) thin films at the heart of the burgeoning thin-film perovskite solar cells (PSCs) technology possess poor mechanical properties, which is likely to limit the long-term reliability of PSCs as they are poised for commercialization. In an effort to address this issue, in this work we demonstrate that through-thickness cracks induced by bending-tension in thin films of the two prototypical OlHPs, methylammonium lead triiodide (MAPbl(3)) and formamidinium lead triiodide (FAPbl(3)), can be healed easily. This is through the application of either a moderate compressive stress (bending-compression) at room temperature or a simple heat-treatment at modest temperatures. The crack-healing process is found to be time-dependent, which indicates that facile mass-transport in OlHPs plays a key role in this phenomenon. An explanation for this phenomenon is provided, one based on the fundamentals of brittle fracture. This discovery has broad implications for the prevention and/or restoration of the overall performance, environmental stability, and mechanical reliability of PSCs, and other devices.

36 MATERIALS SCIENCE↗