Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Effect of oxy-firing on fireside corrosion

Using oxygen, rather than air, in coal-fired boilers has been studied for several years as a strategy to reduce NO{sub x} and concentrate CO{sub 2} for capture. In combination with flue gas recirculation, higher levels of CO{sub 2}, H{sub 2}O and likely SO{sub 2} are expected. In order to understand the role of substrate composition on corrosion, a combination of commercial and model alloys are being investigated both with and without the presence of synthetic coal ash. The current project is focusing on ferritic steels but rates will be compared with austenitic steels, Ni-base alloys, and potential coating compositions.

01 COAL, LIGNITE, AND PEAT↗

Heat Transfer and Thermophotovoltaic Power Generation in Oil-fired Heating Systems

The focus of this study is the production of electric power in an oil-fired, residential heatingsystem using thermophotovoltaic (TPV) conversion devices. This work uses experimental, computational, and analytical methods to investigate thermal mechanisms that drive electric power production in the TPV systems. An objective of this work is to produce results that will lead to the development of systems that generate enough electricity such that the boiler is self-powering. An important design constraint employed in this investigation is the use of conventional, yellow-flame oil burners, integrated with a typical boiler. The power production target for the systems developed here is 100 W - the power requirement for a boiler that uses low-power auxiliary components. The important heattransfer coupling mechanisms that drive power production in the systems studied are discussed. The results of this work may lead to the development of systems that export power to the home electric system.

02 PETROLEUM↗

Fire and Explosion Hazards Expected in a Laboratory

Scientists at universities across Iraq are actively working to report actual incidents and accidents occurring in their laboratories, as well as structural improvements made to improve safety and security, to raise awareness and encourage openness, leading to widespread adoption of robust Chemical Safety and Security (CSS) practices. This manuscript is the fifth in a series of five case studies describing laboratory incidents, accidents, and laboratory improvements. In this study, we summarize unsafe practices involving the improper installation of a Gas Chromatograph (GC) at an Iraqi university which, if not corrected, could have resulted in a dangerous fire and explosion. We summarize the identified infractions and highlight lessons learned. Here, by openly sharing the experiences at the university involved, we hope to minimize the possibility of another researcher being injured due to similarly unsafe practices in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Development of a Residential Gas-Fired Heat Pump

Heating, ventilating, and air-conditioning equipment consumes 43% of the total primary energy consumption in U.S. households. Presently, conventional gas furnaces have maximum heating efficiencies of 98%. Electric air conditioners used in association with the furnace for cooling have a minimum seasonal energy efficiency ratio (SEER) of 14.0. A residential gas-fired heat pump (RGHP) was developed and tested under standard rating conditions, resulting in a significant increase in heating efficiency of over 40% versus conventional natural gas furnaces. The associated efficiency of the RGHP in cooling mode is comparable in efficiency to an electric air conditioner (14.0 SEER) when compared on a primary energy basis. The RGHP is similar in nature to a conventional heat pump but with two main differences. First, the primary energy savings are higher, based on a site versus source comparison, as the result of using natural gas to supply shaft power to the compressor rather than an electric motor. Second, waste heat is recovered from the engine to supplement space heating and reduce the energy input. It can also be used to provide supplemental water heating. The system utilizes a programmable logic controller that allows variable-speed operation to achieve improved control to meet building loads. RGHPs significantly reduce peak electric use during periods of high demand, especially peak summer loads, as well as peak winter loads in regions with widespread use of electric heating. This contributes to leveling year-round gas loads, with the potential to increase annual gas demand in some regions. The widespread adoption of RGHPs will contribute to significant reductions in primary energy consumption and carbon emissions through improved efficiencies.

energy efficiency↗

Comparison of aerosol optical properties above clouds between POLDER and AeroCom models over the South East Atlantic Ocean during the fire season

Aerosol properties above clouds have been retrieved over the South East Atlantic Ocean during the fire season 2006 using satellite observations from POLDER (Polarization and Directionality of Earth Reflectances). From June to October, POLDER has observed a mean Above-Cloud Aerosol Optical Thickness (ACAOT) of 0.28 and a mean Above-Clouds Single Scattering Albedo (ACSSA) of 0.87 at 550nm. These results have been used to evaluate the simulation of aerosols above clouds in 5 AeroCom (Aerosol Comparisons between Observations and Models) models (GOCART, HadGEM3, ECHAM5-HAM2, OsloCTM2 and SPRINTARS). Most models do not reproduce the observed large aerosol load episodes. The comparison highlights the importance of the injection height and the vertical transport parameterizations to simulate the large ACAOT observed by POLDER. Moreover, some models overestimate the ACSSA. In accordance with recent recommendations of the black carbon refractive index, a higher prescription of the imaginary part allows a better comparison with POLDER’s ACSSA.

54 ENVIRONMENTAL SCIENCES↗

Fabrication of diatomite‐based microencapsulated flame retardant and its improved fire safety of unsaturated polyester resin

To achive excellent fire resistance, new microcapsule flame retardants (DMCAD and DMPPD) were prepared using 9,10‐dihydro‐9‐oxa‐10‐phosphaphenanthrene‐10‐oxide combined with melamine cyanurate or melamine polyphosphate as the shell material and diatomite as the core material. The successful assembly of DMCAD and DMPPD was detailed characterized by Fourier transform infrared (FT‐IR) spectra, X‐ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM). Meanwhile, the flame retardancy and thermal stability of the unsaturated polyester resin (UPR)/DMCAD and UPR/DMPPD composites were also studied. The addition of DMCAD and DMPPD effectively improves the flame retardance properties of UPR, and the effect of DMPPD was better. The limiting oxygen index (LOI) of UPR/DMPPD‐3 increased by 11.6% when compared with that of UPR, and the sample achieved V‐0 rating. Moreover, the peak heat release rate (pHRR) and the total heat release (THR) rate of UPR/DMPPD‐3 were reduced by 67% and 26%, respectively. Under nitrogen condition and air condition, UPR/DMPPD showed better thermal stability and char‐forming ability from the thermogravimetric (TG) results. Residual char of the UPR composites was systematically analyzed with SEM and XPS. Finally, the flame retardant mechanism of DMPPD was proposed.

Chen, Gang↗

Fire and Explosion Safe Technology of Storage and Regasification of Liquefied Petroleum Gas

The technology of storage and regasification of liquefied petroleum gas that implies storage in an isothermal tank and overheating the gas with subsequent supply of the vapor phase to the consumer is offered. The necessary storage and regasification temperatures are achieved by means of utilizing a vapor-compression refrigeration unit in the technological process. The technology allows to improve energy efficiency of the processes, reduce fire-and-explosion hazard, minimize LPG losses, exclude conditions formation of a combustible environment, regulate the storage temperature of LPG of various composition and efficiency of the regasification process, and ensure the composition of volatilized LPG remains constant during regasification.

02 PETROLEUM↗

Investigation of in situ high temperature sensor based on the direct absorption spectroscopy signal of ammonia gas for coal-fired power plant

The selective catalytic reduction and non-selective catalytic reduction (SCR/SNCR) are the most popular de-NOx processes for coal-fired power plant, where the real-time temperature is a significant parameter. A new developed tunable diode laser spectroscopy used for measuring the temperature of ammonia (NH{sub 3}) in the process of SCR/SNCR influenced by strong exhaust gas matrices CO{sub 2} and H{sub 2}O was presented in this paper. Two lines near 6605 cm{sup −1} were selected, with rather weak temperature dependency and minimal interface from CO{sub 2} and H{sub 2}O according to HITRAN12 database. A homemade heating equipment for high temperature laser spectroscopy measurement was developed based on an ARM microcontroller. The temperature calibration experiments of absorption lines were carried out at variable concentrations under different temperatures. The spectral signals of 2.5%, 3.5% and 4.5% NH{sub 3} were observed for validation of the generalization and robustness of the sensor. The calibration and validation experimental results show that the maximum measurement error and global average error of the temperature sensor with the temperature ranging from 453 to 653 K are less than 2% and 1.38%, respectively. It demonstrates that our proposed sensor with high accuracy and linearity, and can be utilized to measure the temperature in SNCR/SCR process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Failure Analysis and Magnetic Evaluation of Tertiary Superheater Tube Used in Gas-Fired Boiler

Failure analysis was carried out on a prematurely failed tertiary superheater tube used in gas-fired boiler. The analysis includes a comparative study of visual examination, chemical composition, hardness and microstructure at failed region, adjacent and far to failure as well as on fresh tube. The chemistry was found matching to the standard specification, whereas the hardness was low in failed tube compared to the fish mouth opening region and the fresh tube. Microscopic examination of failed sample revealed the presence of spheroidal carbides of Cr and Mo predominantly along the grain boundaries. The primary cause of failure is found to be localized heating. Magnetic hysteresis loop (MHL) measurements were carried out to correlate the magnetic parameters with microstructure and mechanical properties to establish a possible non-destructive evaluation (NDE) for health monitoring of the tubes. The coercivity of the MHL showed a very good correlation with microstructure and mechanical properties deterioration enabling a possible NDE technique for the health monitoring of the tubes.

36 MATERIALS SCIENCE↗

Potential reductions in fine particulate matter and premature mortality following implementation of air pollution controls on coal-fired power plants in India

Coal-fired power plants (CFPPs) account for > 70% of electricity generation in India, but < 5% of facilities have installed technologies for sulfur dioxide (SO 2 ) and nitrogen oxide (NO X ) removal. Emissions of these pollutants lead to the formation of fine particulate matter (PM 2.5 ) and an increased risk of premature mortality for exposed populations. Here, we use a nested version of the GEOS-Chem global chemical transport model (0.5° × 0.625° resolution) for India to estimate reductions in PM 2.5 concentrations that could have been achieved by implementing existing emission control technologies like flue-gas desulfurization (FGD) and/or selective catalytic reduction (SCR). We quantify the associated burden of disease using the integrated exposure response (IER) and global exposure mortality model (GEMM) functions and compare the costs of premature mortality to those for FGD installation. Model simulations for 2010 suggest installation of FGD would have reduced mean annual PM 2.5 concentrations across India by 8%, compared to 3% with SCR installation, and 11% with both FGD and SCR. A 7–28% reduction in PM 2.5 was simulated for local communities closest to CFPPs (same model grid cell), leading to up to 17% reduction in annual premature mortality. Overall, more than 0.21–0.48 million premature deaths would have been avoided over a 10-year period if FGD had been implemented on all CFPPs, compared to 0.09–0.21 million with SCR and 0.22–0.72 million with both FGD and SCR. Benefits associated with such actions are approximately $\$18.1$–$\$604$ billion USD per year, which is equivalent to ~ 0.44 to 10% of India’s GDP. These results suggest that monetary benefits from avoided premature mortality far outweigh the capital and operational costs of FGD and/or SCR installation of $\$19.5$ billion and/or $\$32.8$ billion per year, respectively. This information is essential because the high costs of installation and operation are often given as reasons for delaying installation and commissioning. Finally, we conclude that policy actions to control air pollution from CFPPs are economically justifiable.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Orexin-A signaling in the paraventricular nucleus modulates spontaneous firing of glucose-sensitive neurons and promotes food intake via the NPY pathway in rats

Understanding the mechanisms regulating feeding is crucial to unraveling the pathogenesis of obesity. The study primary explored the effects of orexin-A and neuropeptide Y (NPY) signaling in the hypothalamic paraventricular nucleus (PVN) on feeding and glucose-sensitive (GS) neuron activity in rats. Microinjection of orexin-A into the PVN promoted feeding and modulated the spontaneous firing of GS neurons. Those effects were eliminated by pre-injection of the orexin-A receptor-1 (OX1R) antagonist SB-334867 and weaken by the NPY-1 receptor (NPY-1R) antagonist BMS-193885. After orexin-A administration into the PVN, the number of c-fos cells in the arcuate nucleus (ARC) was significantly higher than that in the group receiving normal saline. Furthermore, most cells exhibited co-expression of NPY and c-fos, indicating activation of NPY neurons in the ARC by PVN-administered orexin-A, which might be involved in feeding regulation. These findings indicate that orexin-A and NPY signaling in the PVN are essential to regulating GS neuronal excitability and feeding in rats.

60 APPLIED LIFE SCIENCES↗

On the mechanism of polypropylene fibres in preventing fire spalling in self-compacting and high-performance cement paste

With the increasing application of self-compacting concrete (SCC) in construction and infrastructure, the fire spalling behavior of SCC has been attracting due attention. In high performance concrete (HPC), addition of polypropylene fibers (PP fibers) is widely used as an effective method to prevent explosive spalling. Hence, it would be useful to investigate whether the PP fibers are also efficient in SCC to avoid explosive spalling. However, no universal agreement exists concerning the fundamental mechanism of reducing the spalling risk by adding PP fiber. For SCC, the reduction of flowability should be considered when adding a significant amount of fibres. In this investigation, both the micro-level and macro-level properties of pastes with different fiber contents were studied in order to investigate the role of PP fiber at elevated temperature in self-compacting cement paste samples. The micro properties were studied by backscattering electron microscopy (BSE) and mercury intrusion porosimetry (MIP) tests. The modification of the pore structure at elevated temperature was investigated as well as the morphology of the PP fibers. Some macro properties were measured, such as the gas permeability of self-compacting cement paste after heating at different temperatures. The factors influencing gas permeability were analyzed. It is shown that with the melting of PP fiber, no significant increase in total pore volume is obtained. However, the connectivity of isolated pores increases, leading to an increase of gas permeability. With the increase of temperature, the addition of PP fibers reduces the damage of cement pastes, as seen from the total pore volume and the threshold pore diameter changes. From this investigation, it is concluded that the connectivity of pores as well as the creation of micro cracks are the major factors which determine the gas permeability after exposure to high temperatures. Furthermore, the connectivity of the pores acts as a dominant factor for temperatures below 300 deg. C. For higher temperatures micro cracks are becoming the major factor which influences the gas permeability.

36 MATERIALS SCIENCE↗

Effect of thickness on degradation of austenitic 347H steel by direct-fired supercritical CO 2 power cycle environment

Austenitic 347H steel of two thicknesses (2.54 and 0.6 mm) was exposed to a simulated direct-fired supercritical CO 2 (sCO 2 ) power cycle environment at 650°C and 1 atm for 1000 h then tensile stressed at room temperature to study the deformation behavior. The thicker 347H formed a protective chromia scale over most of the surface, which minimized carburization of the underlying steel and resulted in no change in mechanical performance. In stark contrast, the thinner 347H formed non-protective Fe-rich oxides over the entire surface, resulting in extensive carburization of the underlying steel. Finally, this led to increased strength but significantly reduced ductility, resulting in partially brittle failure

36 MATERIALS SCIENCE↗

Accumulation of trace elements and growth responses in Corbicula fluminea downstream of a coal-fired power plant

Lentic organisms exposed to coal-fired power plant (CFPP) discharges can have elevated trace element concentrations in their tissues, but this relationship and its potential consequences are unclear for lotic organisms. To explore these patterns in a lotic environment, we transplanted Corbicula fluminea from a reference stream to a stream receiving CFPP discharge. We assessed trace element accumulation and glutathione concentration in clam tissue, shell growth, and condition index at five sites along a contamination gradient. Clams at the most upstream and contaminated site had the highest growth rate, condition index, glutathione concentrations, and concentrations of arsenic (7.85 {+-} 0.25 {mu} g/g (dry mass)), selenium (17.75 {+-} 0.80 {mu} g/g), and cadmium (7.28 {+-} 0.34 {mu} g/g). Mercury concentrations declined from 4.33 {+-} 0.83 to 0.81 {+-} 0.11 {mu} g/g (dry mass) in clams transplanted into the selenium-rich environment nearest the power plant, but this effect was not as evident at less impacted, downstream sites. Even though dilution of trace elements within modest distances from the power plant reduced bioaccumulation potential in clams, long-term loading of trace elements to downstream depositional regions (e.g., slow moving, silty areas) is likely significant.

01 COAL, LIGNITE, AND PEAT↗

Modeling and simulation of fire spreading through the activity tracking paradigm

Modeling and simulation is essential for understanding complex ecological systems. However, knowledge of the structure and behavior of these systems is limited, and models must be revised frequently as our understanding of a system improves. Moreover, the dynamic, spatial distribution of activity in very large systems necessitates mapping natural mechanisms as logically as possible onto computer structures. This paper describes theoretical and algorithmic tools for building component-based models and simulations of dynamic spatial phenomena. These methods focus attention on and exploit the irregular distribution of activity in ecological processes. We use the DEVS formalism as the basis for a component based approach to modeling spatially distributed systems. DEVS is a mathematical theory of discrete-event systems that is well suited for describing large systems that are described by small parts with irregular, short-range interactions. This event-based approach to modeling leads naturally to efficient simulations algorithms which focus on the active parts of a large model. Ecological modeling benefits from these efficient the simulation algorithms and the reusability of the model s basic components. Our event-based method is demonstrated with a physics-based model of fire spread.

54 ENVIRONMENTAL SCIENCES↗

Enabling CCS via Low-temperature Geothermal Energy Integration for Fossil-fired Power Generation

Here, among the key barriers to commercial scale deployment is the cost associated with CO 2 capture. This is particularly true for existing large, fossil-fired assets that account for a large fraction of the electricity generation fleet in developed nations, including the U.S. Fitting conventional combustion technologies with CO 2 capture systems can carry an energy penalty of thirty percent or more, resulting in an increased price of power to the grid, as well as an overall decrease in net plant output. Taken together with the positive growth in demand for electricity, this implies a need for accelerated capital build-out in the power generation markets to accommodate both demand growth and decreased output at retrofitted plants. In this paper, the authors present the results of a study to assess the potential to use geothermal energy to provide boiler feedwater preheating, capturing efficiency improvements designed to offset the losses associated with CO 2 capture. Based on NETL benchmark cases and subsequent analysis of the application using site-specific data from the North Valmy power plant, several cases for CO 2 capture were evaluated. These included geothermally assisted MEA capture, CO2BOLs capture, and stand-alone hybrid power generation, compared with a baseline, no-geothermal case. Based on Case 10, and assuming 2.7 MMlb/h of geothermally sourced 150 ºC water, the parasitic power load associated with MEA capture could be offset by roughly seven percent, resulting in a small (~1 percent) overall loss to net power generation, but at levelized costs of electricity similar to the no-geothermal CCS case. For the CO 2 BOLs case, the availability of 150°C geothermal fluid could allow the facility to not only offset the net power decrease associated with CO 2 BOLs capture alone, but could increase nameplate capacity by two percent. The geothermally coupled CO 2 BOLs case also decreases LCOE by 0.75 ¢/kWh relative to the non-hybrid CO 2 BOLs case, with the improved performance over the MEA case driven by the lower regeneration temperature and associated duty for CO 2 BOLs relative to MEA.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design screening and analysis of gas-fired ammonia-based chemisorption heat pumps for space heating in cold climate

Thermally-driven ammonia-based chemisorption heat pumps (CSHP) have the potential to provide high-efficiency space heating in cold climates. Using the reversible chemical bond between sorbent salt and ammonia, CSHP thermochemically pumps heat from the cold ambient to the end-uses of space heating at 50 °C. The heating coefficient of performance (COP) of a CSHP largely depends on the selection of the sorbent salts, cycle configuration, and the system operation. This study uses a thermodynamic model to investigate the performance of six CSHP system configurations, including four single-effect and two double-effect cycles. The feasibility and performance of 121 available NH 3 /salt reactions are studied for each configuration. The thermal COP of the cycles and the primary energy COP of the gas-fired CSHP systems are evaluated assuming 50 °C supply temperature for building space heating and the optimal system designs are identified. The highest thermal COP for single-effect and double-effect cycles under -25 °C ambient temperatures are predicted to be 1.22 and 1.57, respectively. The corresponding primary energy COPs are above 1.0 and 1.15, which are 30% higher than condensing furnaces and is sustained into the same cold temperatures.

42 ENGINEERING↗