Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

In situ temperature measurements in sooting methane/air flames using synchrotron x-ray fluorescence of seeded krypton atoms

Synchrotron x-ray fluorescence has been used to measure temperatures in optically dense gases where traditional methods would fail. These data provide a benchmark for stringent tests of computational fluid dynamics models for complex systems where physical and chemical processes are intimately linked. The experiments measured krypton number densities in a sooting, atmospheric pressure, nonpremixed coflow flame that is widely used in combustion research. The experiments not only form targets for the models, but the simulations also identify potential sources of uncertainties in the measurements, allowing for future improvements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-61: Electrodynamics and Nano-Scale Fluid Dynamics in Protein Localization of Nuclear Pore Complexes

Purpose: To develop a simulation to catalyze a reevaluation of common assumptions about 3 dimensional diffusive processes and help cell biologists gain a more nuanced, intuitive understanding of the true physical hurdles of protein signaling cascades. Furthermore, to discuss the possibility of intracellular electrodynamics as a critical, unrecognized component of cellular biology and protein dynamics that is necessary for optimal information flow from the cell membrane to the nucleus. Methods: The Unity 3D gaming physics engine was used to build an accurate virtual scale model of the cytoplasm within a few hundred nanometers of the nuclear membrane. A cloud of simulated pERK proteins is controlled by the physics simulation, where diffusion is based on experimentally measured values and the electrodynamics are based on theoretical nano-fluid dynamics. The trajectories of pERK within the cytoplasm and through the 1250 nuclear pores on the nuclear surface is recorded and analyzed. Results: The simulation quickly demonstrates that pERKs moving solely by diffusion will rarely locate and come within capture distance of a nuclear pore. The addition of intracellular electrodynamics between charges on the nuclear pore complexes and on pERKs increases the number of successful translocations by allowing the electro-physical attractive effects to draw in pERKs from the cytoplasm. The effects of changes in intracellular shielding ion concentrations allowed for estimation of the “capture radius” under varying conditions. Conclusion: The simulation allows a shift in perspective that is paramount in attempting to communicate the scale and dynamics of intracellular protein cascade mechanics. This work has allowed researchers to more fully understand the parameters involved in intracellular electrodynamics, such as shielding anion concentration and protein charge. As these effects are still far below the spatial resolution of currently available measurement technology this simulation is invaluable to researchers to visualize and study current hypotheses concerning protein dynamics.

60 APPLIED LIFE SCIENCES↗

Efficient Measurement of Length Distribution of 1D Nanoparticles in Solution via Optical Polarimetry

The efficient measurement of the length distribution of nanotubes, nanowires, and other one-dimensional (1D) nanoparticles in solution is important to enable their incorporation into materials and devices and to optimize their processing for properties of interest, such as thermal/electrical conductivity or mechanical strength, in suspensions and composites. We report an electric-field (E-field)-assisted optical-polarimetry technique to measure the length distribution of ensembles of high-aspect-ratio particles in dilute suspension. The degree of alignment of polarizable 1D particles suspended in a fluid under Brownian motion explicitly depends on the E-field strength and the particle length. We show that it is possible to extract the length distribution of 1D nanoparticles suspended in an insulating fluid by applying a range of E-fields and using optical polarimetry to measure the corresponding alignment order parameter. Notably, the method is relatively insensitive to the diameter of the 1D particles, which can be poorly known or vary within a sample. The technique is validated with silver nanowires and carbon nanotubes of known lengths, as well as polymer-depletion-length-separated single-wall carbon nanotube samples with length distributions independently measured with analytical ultracentrifugation. Finally, we demonstrate the ability of the optical-polarimetry technique to quantify changes in the length distribution of ultranarrow, sub-nanometer-diameter single-wall carbon nanotubes under different types and durations of ultrasonication. Within its range of applicability (polarizable 1D nanoparticles in the 0.5 to 15 μm length range, constrained by the voltage stability of the media and the suspended particles), the E-field-assisted optical-polarimetry method is a particularly efficient and accurate method to measure the length distribution of nanowires and nanotubes in suspension.

1D nanoparticles↗

Advancing Reactive Tracer Methods for Measurement of Thermal Evolution in Geothermal Reservoirs (Final Report)

The injection of cold fluids into engineered geothermal system (EGS) and conventional geothermal reservoirs may be done to help extract heat from the subsurface or to maintain pressures within the reservoir (e.g., Rose et al., 2001). As these injected fluids move along fractures, they acquire heat from the rock matrix and remove it from the reservoir as they are extracted to the surface. A consequence of such injection is the migration of a cold-fluid front through the reservoir (Figure 1) that could eventually reach the production well and result in the lowering of the temperature of the produced fluids (thermal breakthrough). Efficient operation of an EGS as well as conventional geothermal systems involving cold-fluid injection requires accurate and timely information about thermal depletion of the reservoir in response to operation. In particular, accurate predictions of the time to thermal breakthrough and subsequent rate of thermal drawdown are necessary for reservoir management, design of fracture stimulation and well drilling programs, and forecasting of economic return. A potential method for estimating migration of a cold front between an injection well and a production well is through application of reactive tracer tests, using chemical whose rate of degradation is dependent on the reservoir temperature between the two wells (e.g., Robinson 1985). With repeated tests, the rate of migration of the thermal front can be determined, and the time to thermal breakthrough calculated. While the basic theory behind the concept of thermal tracers has been understood for some time, effective application of the method has yet to be demonstrated. This report describes results of a study that used several methods to investigate application of reactive tracers to monitoring the thermal evolution of a geothermal reservoir. These methods included (1) mathematical investigation of the sensitivity of known and hypothetical reactive tracers, (2) laboratory testing of novel tracers that would improve method sensitivity, (3) development of a software tool for design and interpretation of reactive tracer tests and (4) field testing of the reactive tracer temperature monitoring concept.

15 GEOTHERMAL ENERGY↗

Maladjustment of kidneys to microgravity: Design of measures to reduce the loss of calcium

Losses of skeletal calcium and body fluids occur during prolonged exposure to microgravity. The kidney plays a major role in regulating the physiological functions involved. Relative to this regulatory function, the kidney performs three operations: filtration of blood plasma through the glomeruli, reabsorption, and secretion of fluid and electrolytes so that needed components are retained and only waste is eliminated in the urine. Using data published in Biomedical Results from Skylab, researchers performed new calculations that reflect more directly the operations of the kidney in the handling of calcium, sodium, chloride, potassium and phosphate during space flight. These calculations revealed that the fraction of filtered calcium that was rejected by renal tubules and excreted in the urine increased by 71 percent, from 1.77 percent (preflight) to 3.02 percent (inflight) of the filtered load. This represents a large absolute increase because the total filtered amount is huge. Because the tubular rejection fraction of other ions increased relatively less than that of calcium, researchers postulate the inflight development of a specific renal defect that causes an excessive loss of calcium in urine and thereby contributes to the weakening of bones.

Nechay, Bohdan R.↗

Joule-Thomson effect and internal convection heat transfer in turbulent He II flow

The temperature rise in highly turbulent He II flowing in tubing was measured in the temperature range 1.6-2.1 K. The effect of internal convection heat transport on the predicted temperature profiles is calculated from the two-fluid model with mutual friction. The model predictions are in good agreement with the measurements, provided that the pressure gradient term is retained in the expression for internal convection heat flow.

Walstrom, P. L.↗

Grossite-Rich Refractory Inclusions in Carbonaceous Chondrites: Evidence for Early Generation of Different O-Isotope Reservoirs in the Protoplanetary Disk and O-Isotope Exchange During Fluid-Rock Interaction

The oxygen isotopic composition of the Sun inferred from the measurements of the solar wind returned by the Genesis spacecraft is O-16-enriched (△O-17 = -28.4±3.6‰) relative to the whole-rock O-isotope compositions of chondrites and achondrites, and chondrule phenocrysts, which all plot close to the terrestrial fractionation line (△O-17 ∼ ±5‰). Vast majority of refractory inclusions (CAIs and AOAs) in carbonaceous chondrites of petrologic types 2-3.0 are iso-topically uniform and have solar-like △O-17. In contrast, CAIs and AOAs in metamorphosed CV and CO chondrites are isotopically heterogeneous with melilite, anorthite, perovskite, Zr- and Sc-rich oxides and silicates, and occasionally Al, Ti-diopside being O-16-depleted relative to hibonite, spinel, Al-diopside, and forsterite. The timing of generation of different O-isotope reservoirs and the nature of O-isotope heterogeneity in refractory inclusions in CO3 and CV3 chondrites are poorly known. Grossite (CaAl4O7) is one of the first minerals predicted to condense from a gas of solar composition and therefore it could have recorded isotopic compositions of reservoirs during the earliest stages of the Solar System evolution. Here we report on O-isotope compositions of grossite-rich CAIs in CH3 and CO3 chondrites measured in situ with the UH Cameca ims-1280. For analytical procedures see [9].

A N Krot↗

Synthesis and Characterisation of Caesium Phosphomolybdate and Zirconium Molybdate found in the Highly Active Storage Tanks at Sellafield - 18154

Caesium phosphomolybdate (Cs{sub 3}PMo{sub 12}O{sub 40}.xH{sub 2}O, CPM) and zirconium molybdate (ZrMo{sub 2}O{sub 7}(OH){sub 2}.xH{sub 2}O, ZM) are two known fission products that precipitate out within the Highly Active Storage Tanks (HASTs) at Sellafield, potentially causing 'hot-spots' and blocking pipes. Currently, there is not enough behavioural understanding of these compounds present in the Highly Active Liquor (HAL) for effective Post Operational Clean Out (POCO) strategic planning. As the HASTs do not have an in situ monitoring system the behaviour of the HAL cannot be directly observed. Therefore, as with this research, non-radioactive simulants can be utilised to aid behavioural understanding to assist with the planning of future waste management programs. CPM, along with two different morphologies of ZM were characterised and compared to the common oxide particle material titanium dioxide (TiO{sub 2}). The study provides a detailed physical characterisation of the simulants including: particle shape, particle size, water content and crystal structure, along with zeta particle potential, suspension settling and compressive yield stress. CPM was found to be spheroidal in nature with a particle size of 275 nm and an x value of 13 H{sub 2}O which crystallises as a cubic lattice with space group Pn-3m. ZM was found to have a range of morphologies from cuboidal to wheat-sheaf, varying in size from 10 μm to 20 μm, with an x value of between 3 and 4 H{sub 2}O, which crystallise as a body-centred tetragonal lattice with space group I4{sub 1cd}. TiO{sub 2} used as a comparison simulant was found to be spheroidal in shape with particle size of 725 nm. The isoelectric points (IEPs) of the two ZM samples (ZM-A and ZM-B) with different morphologies were found to be pH 2.5, while for TiO{sub 2} it was pH 3.2. For CPM it could not be confidently identified due to its instability within the acidic environment. The settling rates and compressive yield stress of all simulants were tested in both water and 2 M nitric acid, conditions that replicate the HASTs. TiO{sub 2}, ZM-A and ZM-B all found settled faster in acid than in water. For CPM, slightly faster settling in acid was measured. For all samples it was found that as the particle concentration increased the settling rate decreased, which is a result of hindered settling. For compressive yield stress, similar trends were observed for CPM with little variation in its behaviour in acid and water, suggesting that the particles are highly aggregated in both fluids. For ZM samples little change in equilibrium volume fraction was measured with an increase in pressure (both acid and water). However, overall the sediment bed was denser in water, a result of the rapid settling in acid not allowing the non-spherical particles to pack in an ordered manner. It has been highlighted that both CPM and ZM within the acidic conditions of the HASTs, result in unstable and aggregated compounds, which settle quickly to form large open networks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Elastohydrodynamic film thickness model for heavily loaded contacts

An empirical elastohydrodynamic (EHD) film thickness formula for predicting the minimum film thickness occurring within heavily loaded contacts (maximum Hertz stresses above 150,000 psi) was developed. The formula was based upon X-ray film thickness measurements made with synthetic paraffinic, fluorocarbon, Type II ester and polyphenyl ether fluids covering a wide range of test conditions. Comparisons were made between predictions from an isothermal EHD theory and the test data. The deduced relationship was found to adequately reflect the high-load dependence exhibited by the measured data. The effects of contact geometry, material and lubricant properties on the form of the empirical model are also discussed.

Loewenthal, S. H.↗

Elastohydrodynamic film thickness model for heavily loaded contacts

An empirical elastohydrodynamic (EHD) film thickness formula for predicting the minimum film thickness occurring within heavily loaded contacts (maximum Hertz stresses above 1.04 GN/sq m (150,000 psi)) was developed. The formula was based upon X-ray film thickness measurements made with synthetic paraffinic, fluorocarbon, Type II ester, and polyphenyl ether fluids covering a wide range of test conditions. Comparisons were made between predictions from an isothermal EHD theory and the test data. The deduced relationship was found to adequately reflect the high-load dependence exhibited by the measured data. The effects of contact geometry, material, and lubricant properties on the form of the empirical model are also discussed.

Loewenthal, S. H.↗

Characterization of Aquifer Poroelastic Response to Impulse and Oscillatory Well Pressure Using Distributed Acoustic Sensing

Abstract The storage of fluids in the subsurface is critical for a broad spectrum of applications including managed aquifer recharge, storage of liquefied carbon dioxide and hydrogen, geothermal heat extraction and exploitation of hydrocarbon. It is surprising then, that there has been relatively little measurement of the vertical distribution of poroelastic storage in geologic formations as compared with permeability. We present experiments in which fluid was injected into an important regional aquifer and the depth‐dependent strain response measured using fiber optic distributed acoustic sensing. The formation expansion and contraction in response to fluid injection were several 100 nanostrain. Strain, and the implied storage distribution, was highly localized in specific strata and demonstrated complex, hydromechanical behavior. This new window into fluid‐geomechanical coupling undermines some typically use models and observations currently in practice, but provides potential for complete representation and prediction of fluid storage in the subsurface.

58 GEOSCIENCES↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Microgravity Emissions Laboratory Testing of the Light Microscopy Module Control Box Fan

The Microgravity Emissions Laboratory (MEL) was developed at the NASA Glenn Research Center for the characterization, simulation, and verification of the International Space Station (ISS) microgravity environment. This Glenn lab was developed in support of the Fluids and Combustion Facility (FCF). The MEL is a six-degrees-of-freedom inertial measurement system that can characterize the inertial response forces (emissions) of components, subrack payloads, or rack-level payloads down to 10 7g. The inertial force output data generated from the steady-state or transient operations of the test article are used with finite element analysis, statistical energy analysis, and other analysis tools to predict the on-orbit environment at specific science or rack interface locations. Customers of the MEL have used benefits in isolation performance testing in defining available attenuation during the engineering hardware design phase of their experiment s development. The Light Microscopy Module (LMM) Control Box (LCB) fan was tested in the MEL in June and July of 2002. The LMM is planned as a remotely controllable on-orbit microscope subrack facility that will be accommodated in an FCF Fluids Integrated Rack on the ISS. The disturbances measured in the MEL test resulted from operation of the air-circulation fan within the LCB. The objectives of the testing were (1) to identify an isolator to be added to the LCB fan assembly to reduce fan-speed harmonics and (2) to identify the fan-disturbance forcing functions for use in rack-response analysis of the LMM and Fluids Integrated Rack facility. This report describes the MEL, the testing process, and the results from ground-based MEL LCB fan testing.

McNelis, Anne M.↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Defining Fe and H Speciation During Olivine Carbonation Under Highly Reducing Conditions

The overarching goal of this DOE EC project has been to examine the connections among the geochemical behavior of iron, and the extent of hydrogen, methane or carbonate mineral formation during the aqueous alteration of olivine and pyroxene bearing rocks at near surface temperatures and pressures. We used an integrated suite of microscale x-ray scattering and spectroscopic techniques to interrogate the reactivity and progressive alteration of peridotites during water/rock interaction. We also identified microbial communities in alkaline subsurface fluids, and their role in H 2 -consumption and methane production. A third research thrust integrated these themes, and involved measuring the stable isotope composition (δD and δ 13 C) of hydrogen, water and methane from subsurface fluids and our peridotite hydration experiments to determine whether the water-rock reaction pathways (including biologically influenced systems) can be detected and interpreted in-situ.

58 GEOSCIENCES↗

Pronghorn Porous Media Model Validation with Pressure Drop Measurements

The verification and validation (V&V) of Pronghorn is imperative to assert its accuracy when predicting the fluid velocity, temperature, and pressure in high temperature gas-cooled reactors. Pronghorn is a coarse-mesh, intermediate-fidelity, and multidimensional thermal-hydraulics (TH) code developed by the Idaho National Laboratory (INL). New pebble bed experiments are used to observe the details of the fluid motion and pressure drop in the porous bed under the reactor normal operation. This paper focuses on the validation of the Pronghorn compressible and incompressible Navier-Stokes equations using the pressure drop measurements performed at the engineering-scale pebble bed facility at the Texas A&M university (TAMU). Various pressure drop correlations and porosity functions are implemented in both Pronghorn and STAR-CCM+ to compare the pressure drop due to the combined viscous and inertial resistances in the porous bed. The correlations accounting for the near-wall effect are also utilized to observe if the pressure drop estimates can be improved. Pronghorn porous media models predict the pressure drop well relative to the STAR-CCM+ simulation results and 1D correlations, and both the finite element method (FEM) and finite volume method (FVM) perform accurately. Pronghorn models are also validated with the experimental measurements given the different Reynolds number ranges and specific aspect ratios. The likelihood of the statistical significance between the pressure drop measurements and specific correlations or simulations is low provided that the overlap of their confidence intervals is more than the half of a single arm. Several validation metrics are reasonable in regard to the similar studies from other literature. The precise average pebble bed porosity estimation has much impact on the pressure drop, and the Foumeny and Montillet (dense packing) models carry out the accurate pressure drop prediction by considering the near-wall effect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Turbulent Liquid Spray Atomization Model for Diesel Engine Simulations (Final Technical Report)

This project addresses the systematic lack of predictive capabilities by spray models within engine CFD codes. We develop a new modeling approach to predict the breakup of diesel sprays based on recent literature showing that liquid turbulence plays a fundamental role in spray atomization. A new body of quantitative validation data is also developed as a critical element of the project, leveraging the joint capabilities of Georgia Tech’s high-pressure continuous-flow spray chamber and Argonne National Lab’s near-nozzle x-ray diagnostics at the Advanced Photon Source. This project contributes spatially-resolved measurements of drop size distribution within well-characterized diesel injectors, Spray A and D, from the Engine Combustion Network (ECN) to the engine combustion community for the first time. Utilizing this new body of measurements, we validate and demonstrate a new spray model for diesel sprays, termed the KH-Faeth model, that predicts global and local spray characteristic more accurately than the widely adopted and employed KH model. Predicted drop size distributions are seen to predict measured drops sizes both quantitatively and predictively, with accurate response in droplet size distributions over a wide range of ambient density, injection pressure, and injector nozzle size (Spray A and D) without model tuning. The KH-Faeth model can reduce error in the predicted centerline droplet size profile by up to 80% for ECN Spray D simulations when compared to use of the widely employed KH model.

33 ADVANCED PROPULSION SYSTEMS↗