Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Fast synthesis of sub-10 nm β-NaYF4:Yb3+, Er3+@NaYF4 core-shell upconversion nanocrystals mediated by oleate ligands

Highlights: • Fast synthesize ultra-small β-NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} UCNCs with 0 min reaction or down to 5.3 nm. • Highly bright sub-10 nm β-NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} core-shell NCs were obtained. • OA{sup −} ligands cannot only promote the α-to-β phase transition, but also inhibit the crystal growth. • OA{sup −} ligands manipulated phase transition and size evaluation is also applicable to other UCNCs. - Abstract: We developed a facile approach for the fast synthesis of ultrasmall and monodisperse β-NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} nanocrystals down to 5.3 nm with the assistant of oleate ligands, based on which the highly bright sub-10 nm β-NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+}@NaYF{sub 4} core-shell nanocrystals with three order of magnitude increased upconversion emission were successfully obtained by a seed-mediated growth method. The reaction time and temperature dependent experimental results implied that the introduciton of extra oleate ligands can both promote the α-to-β phase transition and impeded the crystal growth of NaYF{sub 4}, which is due to the oleate ligand induced orderly arrangement of Y{sup 3+} and capping effect, respectively. It is expected that the oleate ligands mediated phase transition and size evaluation, demonstrated here in NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} NCs, is also applicable to other lanthanide-doped upconversion nanocrystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Anomalous fast atomic dynamics in bulk metallic glasses

It is believed that the strong glass formers tend to be dense packing and have rather slow atomic dynamics. Here, we report that the anomalous fast atomic dynamics exist in an Au 55 Cu 20 Ag 5 Si 20 metallic glass (MG) with good glass forming ability (GFA) by combining X-ray photon correlation spectroscopy measurements with ab initio molecular dynamics simulations. The fast dynamics are mainly originated from the increased mobility of Cu atoms by Ag addition. Ag atoms are inclined to locate at Cu-centered <0, 2, 8, 1> motifs, which slow or accelerate the dynamics of shell Cu atoms, depending on whether Ag atoms appear at the first shells or not, leading to the formation of structural heterogeneity at the atomic level. The results enrich the understanding of atomic dynamics in Cue-Ag-containing MGs and will trigger more studies on the dynamics-GFA relationship in MGs.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fast-switching elliptically polarized soft X-ray beam X13A at NSLS

The X13A beamline at NSLS is dedicated to the generation and uses of fast-switching elliptically polarized soft X-ray radiation in the energy range from 250 to {approx}1600 eV. The source for this beamline is an elliptically polarized wiggler (EPW) that delivers linearly elliptically polarized soft X-rays at a switching rate, between right- and left-handed polarization, up to 100 Hz. The optical design is a spherical grating monochromator (SGM) that focuses and diffracts in plane orthogonal to the polarization switching direction. The X13A beamline scientific program is dedicated to spectroscopy and scattering studies of magnetism and magnetic materials. The fast-switching capability of the EPW enables the use of lock-in techniques, thereby greatly enhancing the detection sensitivity for small polarization-dependent signals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fast method for optical simulation of flood maps of light-sharing detector modules

Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. Here, we present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We also simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. And while the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The performance of the γ-ray tracking array GRETINA for γ-ray spectroscopy with fast beams of rare isotopes

The gamma-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The gamma-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the gamma-ray analysis in terms of Doppler reconstruction and spectral quality. Finally, the results reported in this work were obtained from GRETINA consisting of 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First experimental demonstration of time-resolved X-ray measurements with next-generation fast-timing MCP-PMT

We report the first successful time-resolved X-ray measurements at the APS 10-ID-B beamline by coupling ultrafast scintillators with photodetectors. Multiple scintillator and sensor pairs (LYSO, plastic scintillator, dynode PMTs, MCP-PMT), as well as a standalone detector (diamond), were tested to demonstrate the time-resolved measurements using hard X-rays at energies of 20 keV and above. The experimental results show that a number of choices exist for time-resolved high-energy X-ray beam measurement. Notably, by gating the photocathode, the Argonne fabricated fast-timing microchannel plate photomultiplier and LYSO crystal pair achieved fast signal detection with a rise time of 6 ns and a decay time of 33 ns. Furthermore, these experiments pave the way towards ultrafast imaging technologies using hard X-rays for many applications.

36 MATERIALS SCIENCE↗

Positron annihilation lifetime spectroscopy using fast scintillators and digital electronics

Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron lifetime in a material sample under investigation. The positron trapping at vacancies in the material results in an increased positron lifetime. In this work, we have developed and optimized a PALS experimental setup using organic scintillators, fast digitizers, and advanced pulse processing algorithms. We tested three pairs of different organic scintillators: EJ-309 liquid, EJ-276 newly developed plastic, and BC- 418 plastic, and optimized the data processing parameters for each pair separately. Our high-throughput data analysis method is based on single-pulse interpolation and a constant fraction discrimination (CFD) algorithm. The setup based on the BC-418 detector achieved the best time resolution of 198.3 ± 0.8 ps. We used such optimized setup to analyze two single-crystal quartz samples and found lifetimes of 161 ± 4 ps, 343 ± 12 ps and 1.34 ± 0.05 ns, in good agreement with the characteristic time constants of this material. The proposed experimental set up achieves a time resolution comparable to the minimum positron lifetime in quartz, which makes it possible to accurately characterize material vacancies by discriminating between the lifetimes of either the spin singlet or triplet states of positronium. The optimized data processing algorithms are relevant to all the applications where fast timing is important, such as nuclear medicine and radiation imaging

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-neutron response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators

The response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators to fast neutrons is investigated. Neutron-induced charged-particle reactions are observed in both materials when exposed to the fast neutrons produced by an AmBe source, with pulse-shape discrimination used to separate channels. LaBr 3 (Ce) is found to have the best separation between reaction channels, while LaCl 3 (Ce) has a significantly higher efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative analysis of new crystal and plastic scintillators for fast and thermal neutron detection

This paper considers scintillation and physical properties of efficient organic scintillators tested as single crystals and as components of plastics with pulse shape discrimination (PSD). For the first time, single crystals of 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) were grown for studies of the basic scintillation properties of this new compound. Comparison to classical organic crystals, like anthracene, trans-stilbene, and p-terphenyl, and to more recently introduced organic glass showed that the new crystal belongs to a group of the most efficient scintillators, with light output exceeding that of trans-stilbene and PSD comparable to that of p-terphenyl. Furthermore, additional studies were conducted to evaluate scintillation performance and physical properties, like hardness and dye leaching, of plastic scintillators prepared with PhF, organic glass, and liquid diisopropylnaphthalene (DIPN) that were considered as examples for potential replacement of PPO (2,5-diphenyloxazole) in current commercial PSD plastic scintillators. Comparison of the highest performing plastic scintillators prepared with these dyes shows that PhF formulations produced a record light output (LO) increase of 69 % relative to EJ-200. Similar improvements obtained with 6 Li-loaded formulations showed that future development of PSD plastics should not be limited to use of PPO but must involve the search and exploration of new efficient dyes that may lead to discovery of much brighter organic scintillators with improved physical properties required for fast and thermal neutron detection, fast neutron spectroscopy, and antineutrino detection applications.

9,9-dimethyl-2-phenyl-9H-fluorene↗

Benchmarking fast-neutron response of 7 Li-enriched C 7 LYC scintillators: Simulations and experiment

New insights into the fast neutron response of 7 Li-enriched C 7 LYC scintillators have been obtained through detailed Geant4 simulations of 35 Cl(n,p) and 35 Cl(n, α) reactions that are primarily responsible for the fast neutron response of C 7 LYC. The light output of a 1” x1” C 7 LYC detector was simulated using the Birks equation for light quenching in scintillators. The simulations were benchmarked against neutron scattering data from a 12 C target obtained with a white neutron beam at the Los Alamos LANSCE facility and fourteen 1”x1” C 7 LYC detectors. Incident neutron energies extracted from time-of-flight measurements, and appropriate recoil corrections for the different detector angles were used to map the response of C 7 LYC to mono-energetic neutrons. Resonances in the 35 Cl(n,p) reaction cross-section below 3 MeV incident neutron energy were directly observed in C 7 LYC. The experimental data and simulations are compared with ENDF databases, as well as recent direct cross-section measurements of neutrons scattered from a 35 Cl target. In conclusion, the results suggest a scrutiny of the 35 Cl(n,p) and 35 Cl(n, α) cross sections at low energy in the ENDF library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LaBr 3 : Ce self-activation analysis for measuring fast neutron fields

Measurement of the fast neutron production rate in deuterium–tritium (D–T) fusion reactions is important for applications such as active interrogation, fusion diagnostics, and borehole logging. Such measurements are typically performed by neutron activation analysis of metal foils, especially copper. Copper foil activation analysis requires efficiency and energy calibrations of the detector used to measure the foil, and it relies on the detection of 511 keV gamma rays, which are prominent in the active background when neutrons are being produced. Alternatives, such as 79m Br produced by inelastic neutron scattering on 79 Br, are limited by short half-life, low-energy gamma emission, and inability to selectively measure D–T neutrons. This work describes a novel alternative approach to measure ≳10 MeV neutron fields based on self-activation analysis of a LaBr 3 :Ce detector. The activity of 78 Br, the activation product of the 79 Br(n,2n) 78 Br reaction, is used to determine the neutron flux and infer the neutron production rate. We experimentally demonstrate the method with a cylindrical LaBr 3 :Ce crystal with a diameter and height of 3.81 cm that was placed at an ~18 cm distance from the neutron production point, at a 90° angle with respect to the deuteron beam in a D–T neutron generator. Operating voltage and current of the generator were adjusted to evaluate the technique’s performance over a nominal generator output range of approximately (1 - 9) x 10 7 n/s. The neutron output obtained from LaBr 3 :Ce activation agrees to within three standard deviations of the output obtained using copper activation. The self-activation technique can be conveniently employed in a variety of applications to simplify measurements of fast neutrons produced in D–T fusion reactions.

Active interrogationLaBr3↗

A Fast-Valve System for Characterizing Effusive-Flow Properties of Vapor-Transport Systems: RIB Applications

Decay losses, associated with the times required for particles to diffuse from ISOL production targets and to effusively-flow to an ion source, must be reduced to as low as practically achievable levels in order to deliver useful beam intensities of short-lived isotopes for research at ISOL based Radioactive Ion Beam (RIB) facilities. We have developed a fast-valve system and complementary 3-D Monte-Carlo code which can be used separately or in combination to assess the effusive-flow properties of vapor-transport systems, independent of size, geometry and chemical properties of the transport species. In this report, we describe the fast valve and present time spectra and characteristic time data for noble gases flowing through serial- and parallel-coupled vapor-transport systems similar in geometry but longer than those used for RIB generation at the HRIBF with and without target coating matrices.

43 PARTICLE ACCELERATORS↗

Sustainable Thorium Nuclear Fuel Cycles: A Comparison of Intermediate and Fast Neutron Spectrum Systems

This paper presents analyses of possible reactor representations of a nuclear fuel cycle with continuous recycling of thorium and produced uranium (mostly U-233) with thorium-only feed. The analysis was performed in the context of a U.S. Department of Energy effort to develop a compendium of informative nuclear fuel cycle performance data. The objective of this paper is to determine whether intermediate spectrum systems, having a majority of fission events occurring with incident neutron energies between 1 eV and 10 5 eV, perform as well as fast spectrum systems in this fuel cycle. The intermediate spectrum options analyzed include tight lattice heavy or light water-cooled reactors, continuously refueled molten salt reactors, and a sodium-cooled reactor with hydride fuel. All options were modeled in reactor physics codes to calculate their lattice physics, spectrum characteristics, and fuel compositions over time. Based on these results, detailed metrics were calculated to compare the fuel cycle performance. These metrics include waste management and resource utilization, and are binned to accommodate uncertainties. The performance of the intermediate systems for this selfsustaining thorium fuel cycle was similar to a representative fast spectrum system. However, the number of fission neutrons emitted per neutron absorbed limits performance in intermediate spectrum systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High fidelity multiphysics tightly coupled model for a lead cooled fast reactor concept and application to statistical calculation of hot channel factors

A tightly coupled multiphysics code system is established using the MOOSE framework for hot channel factor (HCF) evaluation on a Lead Fast Reactor (LFR) concept. The coupled system is driven by the Griffin multiphysics coupling capability under which the MOOSE Heat Transfer module and NekRS computational fluid dynamics solver are coupled for conjugate heat transfer using the Cardinal application. The coupled capability is demonstrated on an LFR assembly model based on materials and geometry of a prototypical lead-cooled fast reactor design by Westinghouse Electric Company, LLC. Moreover, the work integrates the Multiphysics Object Oriented Simulation Environment (MOOSE) Stochastic Tools Module (STM) to perform calculations for statistical analysis of HCF. Furthermore, the coupling strategy and workflow demonstrated in this paper is not only useful for predicting accurate hot channel factors for different kinds of advanced reactors but also for other engineering applications such as control rod worth assessment, generation of high-fidelity database for Artificial intelligence (AI)/machine learning (ML) training, design optimization and multi-resolution modeling.

Cardinal↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗