Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Gold Code-Phase-Shift Keying: A Power and Bandwidth Efficient Communication Scheme for Smart Buildings

Advanced communications, sensors and controls play an important role in reducing the energy consumption of smart buildings. Wireless sensors have been recently deployed in buildings to provide monitoring and control of several devices such as heating, ventilation, and air-conditioning (HVAC) and lighting systems. In this paper, we present a low-power bandwidth-efficient communication scheme that can be driven by energy harvesting in self-powered wireless sensors. The proposed communication scheme is based on Gold code-phase-shift keying (CPSK) spread-spectrum signaling that improves both transmitter range and power consumption. We present our efforts toward exploring the design, implementation, and performance evaluation of a hardware prototypic Gold CPSK spread-spectrum radio transceiver. Experimental testing in addition to end-to-end system-level simulation-based studies are conducted to evaluate the performance of the Gold CPSK transceiver in terms of receiver sensitivity, coverage range, average probability of bit-error over standard Gaussian and Rayleigh fading-type channels, and multiple access capabilities. The specific engineering tradeoffs are also discussed.

Killough, Stephen M.↗

Analysis of a GaN-Based CRM Totem-Pole PFC Converter Considering Current Sensing Delay

High-frequency soft-switched gallium-nitride (GaN) based critical conduction mode (CRM) totem-pole power factor correction (PFC) converter is one of the most potential candidates in data center power supplies. However, the high-speed cycle-by-cycle zero current detection (ZCD) brings challenges to zero-voltage-switching (ZVS) control. Current sensing delay (CSD) exists, and the ZCD circuit is sensitive to high di/dt switching noise. In this paper, mechanisms of the ZCD time error are elaborated, and impacts of the current sensing delay on converter switching frequency, inductor current, input current third harmonic distortion (THD), and power loss are analyzed. Qualification time is added within the controller for immunity to the swiching noise, and a CSD embedded converter model is proposed to compensate the ZCD time delay. Also, loss modeling of the CRM totem-pole PFC is conducted to aid in analysis of the proposed theory. A 1.5 kW single-phase CRM totem-pole PFC prototype is tested. Experimental results validiate the analysis, modeling, and the proposed compensation method for current sensing delay.

Sun, Jingjing↗

Characterization and Analysis of Insulated Metal Substrate-Based SiC Power Module for Traction Application

This paper presents the electrical characterization and drive cycle--based thermal analysis of an insulated metal substrate (IMS)--based silicon carbide power module for high-power traction inverters. The substrate was constructed using a thin layer of polymer--ceramic blend dielectric material with a thick copper core to improve transient thermal performance. The cooling performance of this module has already been validated with promising results. In this paper, an experimental test bed was set up to evaluate the dynamic and static electrical performance of the designed module under a wide range of operating conditions. The characterization results were then used to develop a drive cycle--based thermal model to validate the performance compared to the traditional direct bonded copper--based power module. The results indicate that the IMS-based power module is a suitable solution for high-power traction applications.

Chowdhury, Shajjad↗

Angle Droop Design for Grid-Forming Inverters Considering Impacts of Virtual Impedance Control

Grid-forming inverters (GFMs) based on active power-frequency droop control and reactive power-voltage droop control have been developed in recent years, which can generate voltage and frequency references for islanded power systems or microgrids to improve system-wide synchronization and power-sharing capability. It is known that the control delays in GFMs may cause system harmonic instability. To eliminate this issue, virtual impedance techniques are normally adopted. This paper gives a comprehensive examination of the impacts of virtual impedance control block Z v in GFMs on system stability. It is revealed that although Z v is effective in eliminating system harmonic stability, it may ruin system synchronization stability as a side effect. To compensate for the negative impacts caused by Z v , an active power-angle control block is added into the conventional droop control. Design criteria are also proposed accordingly to ensure system stability over the entire frequency range. Simulations and experimental testing are conducted to validate the analysis and the proposed design guidelines. It can be concluded that the Z v control-caused grid-synchronization instability issues can be eliminated with an appropriate active power-angle droop design.

Kong, Le↗

A PWM Strategy for Cascaded H-bridges to Reduce the Loss Caused by Parasitic Capacitances of Medium Voltage Dual Active Bridge Transformers

In this paper, to reduce the power loss caused by the parasitic capacitances of medium voltage medium frequency transformers in a two-stage dc/ac converter, including a dual active bridge (DAB)-based dc/dc stage and a cascaded H-bridge (CHB)-based dc/ac stage, a PWM strategy is proposed for the dc/ac stage. For each H-bridge, by shifting the high switching frequency to one half-bridge and having the other half-bridge switching at the fundamental frequency of the ac voltage, equivalent frequencies of transformer terminal-to-ground voltages are reduced. As a result, the frequencies of charging and discharging current to the parasitic capacitance are reduced, and therefore the loss caused by the parasitic capacitances is reduced. Compared to the conventional phase-shift PWM, the proposed PWM strategy can reduce the parasitic capacitance loss by about 75%. Experimental test results of one phase in the 13.8 kV/ 100 kW converter prototype are provided to validate the approach.

Li, Haiguo↗

A Self-Organizing Nano Grid (SONG) for Energy Access Clusters

In this paper, a bottom-up dc Self-Organizing Nano Grid (SONG) for rural electrification at ultra-low-cost through a flexible and scalable topology is presented. The proposed nano grid requires no communication and uses dc-bus signaling to convey excess energy in the system through the bus voltage, allowing independent agents to conduct energy transactions based on their needs in a decentralized manner. Moreover, this article proposes a concept that uses a novel multi-source, multi-segment droop control strategy with demand coordination, allowing for dynamic self-balancing of the system under fluctuating operating conditions. The unique use of a surplus photovoltaic (PV) power droop mode precisely estimates energy availability to minimize load chattering that helps in stabilizing the dc-bus. In addition, this architecture uses standard dc/dc converters for a low-cost, modular, Plug and Play ( PnP ) solution with highly automated operation, enabling local assembly, operation, and maintenance by non-technical personnel. The proposed SONG concept was validated in simulation and with a 700W, laboratory-scale, custom made nano grid system. The simulation and experimental test cases show the feasibility of the SONG system by demonstrating the proposed multi-source, multi-segment droop control strategy without load chattering under varying operating conditions.

dc-dc converter↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]↗

Comparison of Magnetic Field Emission from Unipolar and Bipolar Coil-Based Wireless Charging Systems

In this study, the leakage magnetic field (LMF) from the unipolar (circular, rectangular, etc.) and bipolar (double-D) coil-based wireless charging systems (WCSs) are investigated and compared. The unipolar and bipolar pads, which are the two most widely adopted charging-pads, have significantly different magnetic field emission characteristics. In this paper, the spatial-distribution and vector-pattern of the leakage magnetic field are studied and compared for similar 11 kW unipolar and bipolar coil-based WCSs. The field emissions are simulated using finite element analysis (FEA) and tested experimentally with an 11 kW bipolar coil-based WCS prototype. The results show that the leakage magnetic field of the unipolar and bipolar pads have widely different vector-orientation and spatial distributions of the leakage magnetic field. The results show that the unipolar coil based WCS has a dominant vertical and the bipolar pads coil-based WCS has dominant horizontally aligned leakage magnetic field. Considering the shielding, the aluminum plate is found highly effective for the unipolar pad and almost ineffective for bipolar pads.

Mohammad, Mostak↗

Thermal Analysis of a 50 kW Three-Phase Wireless Charging System

In this paper, the thermal analysis of a 50 kW three-phase wireless charging system (WCS) is presented. Addressing the thermal challenge is essential for designing a compact charging pad for 50 kW and higher-power WCS pads. Low thermal conductivity of the Litz wire and ferrite, and uneven distribution of the coil, and core loss cause the high temperature in the charging pads. In this paper, the loss distribution of a 50 kW three-phase WCS is investigated, and the temperature distribution is simulated using finite element analysis (FEA) considering the magnetic and non-magnetic materials of a charging pad. The thermal characteristics of an extremely high-power density 50 kW WCS prototype are tested experimentally for 10 minutes of operation. The simulation and experimental results show that the coil temperature increases to 65°C, the core temperature varies between 50°C to 150°C, and the packaging temperature increases to 65°C after 10 minutes of operation at rated 50 kW output power.

Mohammad, Mostak↗

A Dynamic Photovoltaic Model Incorporating Capacitive and Reverse-Bias Characteristics

Photovoltaics (PVs) are typically modeled only for their forward-biased dc characteristics, as in the commonly used single-diode model. While this approach accurately models the I-V curve under steady forward bias, it lacks dynamic and reverse-bias characteristics. The dynamic characteristics, primarily parallel capacitance and series inductance, affect operation when a PV cell or string interacts with switching converters or experiences sudden transients. Reverse-bias characteristics are often ignored because PV devices are not intended to operate in the reverse-biased region. However, when partial shading occurs on a string of PVs, the shaded cell can become reverse biased and develop into a hot spot that permanently degrades the cell. To fully examine PV behavior under hot spots and various other faults, reverse-bias characteristics must also be modeled. This study develops a comprehensive mathematical PV model based on circuit components that accounts for forward bias, reverse bias, and dynamic characteristics. Using a series of three experimental tests on an unilluminated PV cell, all required model parameters are determined. The model is implemented in MATLAB Simulink and accurately models the measured data.

Kim, KA↗

Electromagnetic design of the RF cavity beam position monitor for the LCLS.

A high-resolution X-band cavity BPM has been developed for the LCLS. A dipole mode cavity and a monopole mode reference cavity have been designed in order to achieve micron-level accuracy of the beam position. The rf properties of the BPM as well as beam interaction with the cavities will be discussed including output power and tuning. In addition, methods will be presented for improving the isolation of the output ports to differentiate between horizontal/vertical beam motion and to reject extraneous modes from affecting the output signal. The predicted simulation results will be compared to data collected from low-power experimental tests.

43 PARTICLE ACCELERATORS↗

Fusion Materials Science and Technology Research Needs: Now and During the ITER era

The plasma facing components, first wall and blanket systems of future tokamak-based fusion power plants arguably represent the single greatest materials engineering challenge of all time. Indeed, the United States National Academy of Engineering has recently ranked the quest for fusion as one of the top grand challenges for engineering in the 21st Century. These challenges are even more pronounced by the lack of experimental testing facilities that replicate the extreme operating environment involving simultaneous high heat and particle fluxes, large time varying stresses, corrosive chemical environments, and large fluxes of 14-MeV peaked fusion neutrons. This paper will review, and attempt to prioritize, the materials research and development challenges facing fusion nuclear science and technology into the ITER era and beyond to DEMO. In particular, the presentation will highlight the materials degradation mechanisms we anticipate to occur in the fusion environment, the temperature- displacement goals for fusion materials and plasma facing components and the near and long-term materials challenges required for both ITER, a fusion nuclear science facility and longer term ultimately DEMO.

Wirth, Brian D.↗

3-D Thermal-Electric Finite Element Model of a Nb 3 Sn Coil During a Quench

High field superconducting magnets for particle accelerators often exhibit premature quenches. Once a normal zone is generated within the conductor, the quench may propagate causing temperature and resistive voltage rise along the coil. The resulting thermal gradients can potentially cause new peak stresses that might exceed the tolerable limits, degrading the conductor. The computation of the strain state in the coils during quench then becomes of paramount importance for magnet design, and requires a complete three-dimensional (3-D) analysis of quench phenomena. The objective of this paper is to present the first multiphysics modeling activities towards a new full 3-D methodology for the analysis of magnet mechanics during quench. As a first step, a 3-D thermal-electric finite element model of a Nb 3 Sn superconducting coil is developed and explained here. The model uses direct coupled-field elements to solve the system of thermal and electrical equations. A solving algorithm has also been implemented in order to investigate the physics behind quench transients. The output from this model, built in ANSYS APDL, can be easily coupled in a later stage to a mechanical model in order to estimate the strain state in the coil windings. In conclusion, a very good agreement has been observed between the numerical results and experimental tests performed in individual superconducting cables and real superconducting magnets.

43 PARTICLE ACCELERATORS↗

Record High Ramping Rates in HTS Based Superconducting Accelerator Magnet

Here we report results of experimental test of the High Temperature Superconductor (HTS) based fast-cycling prototype accelerator magnet capable to operate up to about 300 T/s field ramping rate with some 0.5 T B-field in the magnet gap. The measured upper limit for the cryogenic cooling power required to support magnet conductor operation at high ramping rates indicates great potential for such type of magnets in rapid cycling synchrotrons for neutrino research or acceleration of very short-lived muons. The test magnet design, construction and supporting cryogenic and power systems are briefly described. The magnet's power test results are discussed in terms of a possible upgrade of this magnet design to 2 T B-field, a maximum feasible with super-ferric magnet.

43 PARTICLE ACCELERATORS↗

Systematic Study on Aluminum Composition Nonuniformity in Aluminum Gallium Nitride Metal–Semiconductor–Metal Photodetectors

Here, the influence of aluminum composition (Al%) nonuniformity on AlGaN metal–semiconductor–metal photodetectors was thoroughly studied on a device level. The Al% fluctuation was precisely measured by x-ray photoelectron spectroscopy and mapped by energy dispersive spectrometry; the dislocation density was investigated by x-ray diffraction rocking curve. Both theoretical simulation and experimental testing showed a significant difference in the responsivity, dark current, and decay time in the device with different Al%. The Al% fluctuation is also a likely cause of the long decay time of the device.

36 MATERIALS SCIENCE↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Nonlinear Decoupling Control with ANFIS-based Unmodeled Dynamics Compensation for A Class of Complex Industrial Processes

Complex industrial processes are multivariable and generally exhibit strong coupling among their control loops with heavy nonlinear nature that make it very difficult to obtain an accurate model. As a result, the conventional and data driven control methods are difficulty to apply. Using a twin-tank level control system as an example, a novel multivariable decupling control algorithm with adaptive neural fuzzy inference system (ANFIS) based unmodeled dynamics (UD) compensation is proposed in this paper for a class of complex industrial processes. At first, a nonlinear multivariable decupling controller with UD compensation is introduced. Different from the general method, the decomposition estimation algorithm by ANFIS is used to estimate the UD, and the desired estimating and decoupling control effects are achieved. Secondly, the proposed method does not require the complex switching mechanism which has been commonly used in the literature. This simplifies the obtained decoupling algorithm and its realization. Thirdly, based on some new lemmas and theorems, the conditions on the stability and convergence of the closed-loop system are analyzed to show the uniform boundedness of all the variables. Finally, experimental tests on a heavily coupled nonlinear twin-tank system are carried out to demonstrate the effectiveness and the practicability of the proposed method.

Complex industrial process, ANFIS, multivariable a↗