Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Systems Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Integrated Vulnerability and Impacts Assessment for Natural and Engineered Water-Energy Systems in the Southwest and Southern Rocky Mountain Region

In the Southwest and Southern Rocky Mountains (SWSRM), energy production, energy resource extraction, and other high volume uses depend on water supply from systems that are highly vulnerable to extreme, coupled hydro-ecosystem-climate events including prolonged drought, flooding, degrading snow cover, forest die off, and wildfire. These vulnerabilities, which increase under climate change, present a challenge for energy and resource planners in the region with the highest population growth rate in the nation. Currently, analytical tools are designed to address individual aspects of these regional energy and water vulnerabilities. Further, these tools are not linked, severely limiting the effectiveness of each individual tool. Linking established tools, which have varying degrees of spatial and temporal resolution as well as modeling objectives, and developing next-generation capabilities where needed would provide a unique and replicable platform for regional analyses of climate-water-ecosystem-energy interactions, while leveraging prior investments and current expertise (both within DOE and across other Federal agencies).

13 HYDRO ENERGY↗

Integrated Harsh Environment Gas / Temperature Wireless Microwave Acoustic Sensor System for Fossil Energy Applications

There is a significant need for sensors capable of detecting gases, such as H 2 , O 2 , NO x , SO x within harsh environments encountered in power plants, industrial manufacturing, oil and gas exploration, and aerospace applications. This project successfully demonstrated the use of wireless microwave acoustic sensor technology for the detection of gases (H 2 or O 2 ) from ambient temperatures up to 650°C. The work focused on langasite (LGS) based surface acoustic wave resonator (SAWR) sensors as the harsh-environment sensor platform and explored multiple combinations of high-temperature thin films and device structures which were used to increase the sensor platform stability and detection capability at temperatures in the operational range of 150°C to 700°C. Specific material configurations that were investigated include: yttria-stabilized-zirconia (YSZ) decorated with Pt nanoparticles, atomic layer deposited (ALD) Al 2 O 3 , palladium, and Pt/Al 2 O 3 co-deposited electrode alloys. Through the deposition of YSZ at temperatures as high as 850°C and the use of graded alloy concentrations of Pt in the fabrication of the Pt/Al 2 O 3 electrode structures, film stress problems were mitigated, and sensor operation and stability achieved. To test and evaluate SAWR sensor performance for the detection of H 2 and O 2 under the influence of temperature variations, a comprehensive gas sensor control system and test apparatus was created to operate within a laboratory box furnace-controlled environment. In addition to the advancement in thin film materials through the deposition and fabrication techniques mentioned above, the work characterized the performance of sensors containing these films in the presence of oxidizing and reducing gases between 25°C and 700°C. In particular, the work revealed that the exposure of the SAWR sensor surfaces to oxidizing environments significantly improve the sensor response to H 2 , whereas the exposure of the sensor to reducing environments at high temperatures (≈ 500°C) renders the sensor irresponsive to H 2 , requiring sensor surface treatment at high temperatures (above 500°C) to recover the responsiveness to H 2 . The SAWR sensors have been also tested for wireless operation and array operation using multiple orientations to resolve the detection of gases under temperature variations. The work developed at the University of Maine was aided by a collaboration with the NETL Research and Innovation Center, Pittsburgh, PA, where thin film materials and device structures fabricated at UMaine were tested and characterized using NETL gas reactors and surface analysis techniques. SAWR sensors fabricated at UMaine were exposed multiple times to temperatures up to 700°C and H 2 concentrations up to 100% in the NETL facilities to measure the sensor performance. Environetix Technologies Corporation, a UMaine harsh-environment sensor spin-off company, also provided support and assistance in sensor system testing and implementation. The sensor small size and configuration allows flexible sensor placement and embedding of multiple sensor arrays into a variety of components within power systems and other aerospace or industrial settings that need to be interrogated wirelessly. The SAW platform is an attractive option for high-temperature harsh-environment gas sensing applications due to its inherent features, namely small size, capability of battery-free and wireless operation, and cost effective scale production using well-established production techniques from the semiconductor industry. The research findings achieved in this work, particularly advances regarding the fabrication and performance of the SAWR gas sensor platform, can be adapted and transferred to industrial power plants and other harsh environments.

01 COAL, LIGNITE, AND PEAT↗

Integrated floating wind farm layout design and mooring system optimization to increase annual energy production

As we cluster wind turbines in wind farms to gain energy from sites with high wind speeds, wake losses occur within the wind farm. Wake loss is a term used to describe the lower energy production of a downwind turbine that is totally or partially in the wake of an upwind turbine. To decrease wake losses inside the wind farm, the wind farm’s layout is optimized. However, a variety of factors constrain the wind farm layout optimization, such as the size of the lease area relative to the number of turbines to be placed, or the shape of the lease area. Therefore, many wind farms end up with a regular grid layout, such as the Horns Rev 1 wind farm in the North Sea. The ability of a floating offshore wind turbine (FOWT) to change its position based on the wind direction and its mooring system design presents an opportunity to further decrease wake losses in floating wind farms. In this work, we integrate the design of the FOWT mooring systems with the floating wind farm layout design with the goal of increasing the farm’s annual energy production. We use the Horns Rev 1 wind farm as a case study to demonstrate our method. The results show that allowing the FOWT to relocate can decrease wake losses up to 18%. Moreover, the newly developed mooring systems are less stiff and therefore allow larger motion of the FOWT; hence, the material cost of the mooring system decreases by an estimated 17%.

17 WIND ENERGY↗

Applications of Measuring and Valuing Resilience in Energy Systems

The electricity sector is vulnerable to numerous hazards that are being exacerbated by climate change, which can cause an increase in the hazards' frequency and intensity. Consumers, system regulators, system operators, and communities are now preparing to mitigate the increased risks posed by climate change. New York State's energy infrastructure resilience can be increased with targeted investments including but not limited to installing emergency backup systems, integrating microgrid solutions, weatherizing buildings, increasing energy efficiency, adding redundancy, investing in restoration and recovery, and hardening critical components. Such investments can reduce the likelihood, impact, and consequences of disruptive events but can also increase capital and operating costs. A barrier to prioritizing investments in resilience is that there is no widely established method for quantifying and assigning the benefits of resilience investments across various stakeholders. Decision-makers need better information detailing the value of resilience improvements. Developing methods to quantify, value, and price resilience helps meet resilience needs in an effective manner that also supports broader societal welfare. This report lays out considerations for quantifying and valuing resilience, discusses the current state of resilience valuation tools, and provides case studies of resilience projects that demonstrate how resilience attributes could be measured while highlighting broader, project-specific challenges to increasing resilience. Further, we present insights into methods and challenges to measuring, valuing, and enacting resilience investments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parameter Design and Optimal Control of an Open Core Flywheel Energy Storage System

In low earth orbit (LEO) satellite applications spacecraft power is provided by photovoltaic cells and batteries. To overcome battery shortcomings the University of Maryland, working in cooperation with NASA/GSFC and NASA/LeRC, has developed a magnetically suspended flywheel for energy storage applications. The system is referred to as an Open Core Composite Flywheel (OCCF) energy storage system. Successful application of flywheel energy storage requires integration of several technologies, viz. bearings, rotor design, motor/generator, power conditioning, and system control. In this paper we present a parameter design method which has been developed for analyzing the linear SISO model of the magnetic bearing controller for the OCCF. The objective of this continued research is to principally analyze the magnetic bearing system for nonlinear effects in order to increase the region of stability, as determined by high speed and large air gap control. This is achieved by four tasks: (1) physical modeling, design, prototyping, and testing of an improved magnetically suspended flywheel energy storage system, (2) identification of problems that limit performance and their corresponding solutions, (3) development of a design methodology for magnetic bearings, and (4) design of an optimal controller for future high speed applications. Both nonlinear SISO and MIMO models of the magnetic system were built to study limit cycle oscillations and power amplifier saturation phenomenon observed in experiments. The nonlinear models include the inductance of EM coils, the power amplifier saturation, and the physical limitation of the flywheel movement as discussed earlier. The control program EASY5 is used to study the nonlinear SISO and MIMO models. Our results have shown that the characteristics and frequency responses of the magnetic bearing system obtained from modeling are comparable to those obtained experimentally. Although magnetic saturation is shown in the bearings, there are good correlations between the theoretical model and experimental data. Both simulation and experiment confirm large variations of the magnetic bearing characteristics due to air gap growth. Therefore, the gap growth effect should be considered in the magnetic bearing system design. Additionally, the magnetic bearing control system will be compared to other design methods using not only parameter design but H-infinity optimal control and mu synthesis.

Pang, D.↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Greening the Grid: Advances in Production Cost Modeling for India Renewable Energy Grid Integration Study

The Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid study uses advanced weather and power system modeling to explore the operational impacts of meeting India's 2022 renewable energy targets and identify actions that may be favorable for integrating high levels of renewable energy into the Indian grid. The study relies primarily on a production cost model that simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. This fact sheet provides a detailed look at each of these models, including their common assumptions and the insights provided by each.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Considerations for Developing a Regulatory Roadmap for Distributed Energy Resource (DER) Integration in Colombia

The USAID-NREL Partnership in Colombia, in conjunction with SURE and USEA, selected four action plan teams from the Young Professionals Leadership Program to receive tailored NREL technical assistance to support action plan implementation. The four plans selected represent various aspects associated with planning for the efficient integration of DERs, including electric mobility, residential and commercial energy applications, distributed generation modeling, and regulatory considerations. In response to national grid modernization, decentralization, digitalization, and electrification trends, CREG is looking to update Colombia's electric distribution code, with an emphasis on the integration of electric vehicles and charging stations, but also energy storage systems, non-conventional sources of renewable energy, and other distributed energy resources (DERs). CREG aims to establish the general steps that must be carried out to update the distribution code for the integration of DERs, with a view to the design and development of new markets. The objective of the TA provided to CREG was to support them in identifying and outlining the general processes and approaches to consider when updating Colombia's distribution code for the integration of electric vehicles, distributed renewable energy systems, and energy storage systems, with a view to the design and development of new markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Savings Results from Small Commercial Building Retrofits in the US

Small commercial buildings, or those comprising less than 50,000 square feet of floor area, represent 94% of U.S commercial buildings by count and consume approximately 8% of the nation’s primary energy; as such, they represent a largely unexploited opportunity for energy savings. Small commercial buildings also represent a large economic market—the National Institute of Building Sciences (NIBS) estimated the small commercial retrofit market at USD 35.6 billion. Despite the prominence of small commercial buildings and the economic opportunity for energy retrofits, many energy efficiency programs focus on large commercial buildings, and create efficiency solutions that do not meet the needs of the small commercial market. This paper presents an analysis of 34 small commercial case study projects that implemented energy efficiency retrofits. This paper contributes to the existing building retrofit body of knowledge in the following ways: (1) it identifies the decision criteria used by small commercial building stakeholders that decided to complete an energy retrofit; (2) it identifies the most commonly implemented efficiency measures in small commercial buildings, and discusses why this is the case; and (3) it provides empirical evidence about the efficacy of installing single energy efficiency measures (EEMs) compared to packages of EEMs in small commercial buildings by reporting verified energy savings. To the authors’ knowledge, this paper is the first to catalog decision criteria and energy savings for the existing small commercial buildings market, and this research illustrates that small commercial building decision-makers seem most motivated to retrofit their spaces by energy cost savings and operational concerns. Furthermore, small commercial building decision-makers opted to implement single-system retrofits in fifteen (15) of the thirty-four cases studied. Finally, this research documents the improved savings, in the small commercial buildings market, associated with a more integrated package of EEMs compared to a single-system approach, achieving approximately 10% energy savings for a single-system approach and more than 20% energy savings for integrated approaches. These savings translate to CO2 savings of 1,324,000 kgCO2/year to 2,647,000 kgCO2/year, respectively, assuming small commercial buildings are retrofit at a rate of 0.95% of the stock annually.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proposal of a novel multifunctional energy system for cogeneration of coke, hydrogen, and power - article no. 052001

This paper proposes a novel multifunctional energy system (MES), which cogenerates coke, hydrogen, and power, through the use of coal and coke oven gas (COG). In this system, a new type of coke oven, firing coal instead of COG as heating resource for coking, is adopted. The COG rich in H{sub 2} is sent to a pressure swing adsorption (PSA) unit to separate about 80% of hydrogen first, and then the PSA purge gas is fed to a combined cycle as fuel. The new system combines the chemical processes and power generation system, along with the integration of chemical conversion and thermal energy utilization. In this manner, both the chemical energy of fuel and thermal energy can be used more effectively. With the same inputs of fuel and the same output of coking heat, the new system can produce about 65% more hydrogen than that of individual systems. As a result, the thermal efficiency of the new system is about 70%, and the exergy efficiency is about 66%. Compared with individual systems, the primary energy saving ratio can reach as high as 12.5%. Based on the graphical exergy analyses, we disclose that the integration of synthetic utilization of COG and coal plays a significant role in decreasing the exergy destruction of the MES system. The promising results obtained may lead to a clean coal technology that will utilize COG and coal more efficiently and economically.

08 HYDROGEN↗

NGEE Arctic Integrated Modeling (IM3): Improved snow-vegetation interaction

This data product represents the integration of new code capability for arctic tundra snow-vegetation-terrain interactions into the Energy Exascale Earth System Model (E3SM), through the E3SM Land Model (ELM) component. This code integration is the result of collaborative effort between the NGEE Arctic project and the E3SM project. The NGEE Arctic project developed a total of six Integrated Modeling (IM) modules informed by observations and experiments. New ELM capability represented by this data product (IM3) falls into three categories: 1) Downscaling from gridcell to topographic unit level when working through the existing coupler bypass code. 2) Four new parameters (taper, stocking, bendresist, and vegshape) have been added to ELM to allow for flexible definition of snow-vegetation interactions. 3) Vegshape and bendresist parameters are used to calculate the fraction of leaf area and/or stem area buried by snow for a given snow depth. This data record consists of a single document (pdf format) that describes the theoretical basis for the snow-vegetation-terrain interactions added to ELM, and describes the modifications made to the ELM code. The Methods section of this metadata record includes a link to the public E3SM code repository where the exact code modifications as integrated in E3SM can be accessed. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

Thornton, Peter E [ORNL] (ORCID:0000000247595158)↗

Advanced Control and Power System (ACAPS) Technology Program

The advanced control and power system (ACAPS) program is to establish the technology necessary to satisfy space station and related large space structures requirements for efficient, reliable, and cost effective energy storage and attitude control. Technology advances in the area of integrated flywheel systems capable of performing the dual functions of energy storage and attitude control are outlined.

Keckler, C. R.↗

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America and other programs to reduce energy use while improving the indoor environment. Next Steps The following steps are needed to bring the product to commercialization: (1) Value engineering to reduce costs; (2) Addition of zoning capability to improve marketability; (3) Fabrication and testing of additional prototypes; and (4) Identification of a manufacturer. Initial efforts to interest large air conditioner manufacturers has shown some interest, but the preferred path to market may be to employ a boutique manufacturer that markets to HVAC contractors. Distribution of the results of this work will improve opportunities for attracting manufacturers. Additional funding is needed to prepare the product for this final step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application Guide for the Cyber-Resilient Design Framework for Hybrid Systems

As the energy landscape evolves, hybrid power plants—integrating multiple renewable energy sources (e.g., solar, wind, and battery storage) with the bulk power electric system—play a crucial role in meeting growing energy demands. However, with a hybrid power plant’s increased number of components, complex network connectivity and digitization of controls, these systems face growing cybersecurity risks. To help mitigate these risks, Idaho National Laboratory (INL) presents this application guide specifically designed for operators and systems engineers to evaluate the cybersecurity resilience of their hybrid power plant’s design.

14 SOLAR ENERGY↗