Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Integrated Canada-U.S. Power Sector Modeling with the Regional Energy Deployment System (ReEDS)

The electric power system in North America is linked between the United States and Canada. Canada has historically been a net exporter of electricity to the United States. The extent to which this remains true will depend on the future evolution of power markets, technology deployment, and policies. To evaluate these and related questions, we modify the Regional Energy Deployment System (ReEDS) model to include an explicit representation of the grid-connected power system in Canada to the continental United States. ReEDS is unique among long-term capacity expansion models for its high spatial resolution and statistical treatment of the impact of variable renewable generation on capacity planning and dispatch. These unique traits are extended to new Canadian regions. We present example scenario results using the fully integrated Canada-U.S. version of ReEDS to demonstrate model capabilities. The newly developed, integrated Canada-U.S. ReEDS model can be used to analyze the dynamics of electricity transfers and other grid services between the two countries under different scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind and Solar Energy Curtailment: Experience and Practices in the United States

This report examines U.S. curtailment practices, with a particular emphasis on utilities in the Western states. The information presented here is based on a series of interviews conducted with utilities, system operators, wind energy developers, and non-governmental organizations. The report provides case studies of curtailment experience and examines the reasons for curtailment, curtailment procedures, compensation, and practices that can minimize curtailment.

14 SOLAR ENERGY↗

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE↗

Solar Resource Assessment

This report covers the solar resource assessment aspects of the Renewable Systems Interconnection study. The status of solar resource assessment in the United States is described, and summaries of the availability of modeled data sets are provided.

14 SOLAR ENERGY↗

Rooftop Photovoltaics Market Penetration Scenarios

The goal of this study was to model the market penetration of rooftop photovoltaics (PV) in the United States under a variety of scenarios, on a state-by-state basis, from 2007 to 2015.

14 SOLAR ENERGY↗

Building America Research Benchmark Definition: Updated December 19, 2008

To track progress toward aggressive multi-year whole-house energy savings goals of 40-70% and onsite power production of up to 30%, DOE's Residential Buildings Program and NREL developed the Building America Research Benchmark in consultation with the Building America industry teams.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable Electricity Futures Study - Volume One

This is part of a series of four volumes describing exploring a high-penetration renewable electricity future for the United States of America. This dataset is provides data for the entire volume one document and includes all data for the charts and graphs included in the document.

13 HYDRO ENERGY↗

Analysis of debris from Spacelab Space Life Sciences-1

Airborne microbiological and particulate contamination generated aboard Spacelab modules is a potential safety hazard. In order to shed light on the characteristics of these contaminants, microbial and chemical/particulate analyses were performed on debris vacuumed from cabin and avionics air filters in the Space Life Sciences-1 (SLS-1) module of the Space Transportation System 40 (STS-40) mission 1 month after landing. The debris was sorted into categories (e.g., metal, nonmetal, hair/fur, synthetic fibers, food particles, insect fragments, etc.). Elemental analysis of particles was done by energy dispersive analysis of x rays (metals) and Fourier transform infrared spectroscopy (nonmetals). Scanning electron micrographs were done of most particles. Microbiological samples were grown on R2A culture medium and identified. Clothing fibers dominated the debris by volume. Other particles, all attributed to the crew, resulted from abrasions and impacts during missions operations (e.g., paint chips, plastic, electronic scraps and clothing fibers). All bacterial species identified are commonly found in the atmosphere or on the human body. Bacillus sp. was the most frequently seen bacterium. One of the bacterial species, Enterobacter agglomerans, could cause illness in crew members with depressed immune systems.

Caruso, S. V.↗

Geothermal Power and Interconnection: The Economics of Getting to Market

This report provides a baseline description of the transmission issues affecting geothermal technologies. The report begins with a comprehensive overview of the grid, how it is planned, how it is used, and how it is paid for. The report then overlays onto this 'big picture' three types of geothermal technologies: conventional hydrothermal systems; emerging technologies such as enhanced engineered geothermal systems (EGS) and geopressured geothermal; and geothermal co-production with existing oil and gas wells. Each category of geothermal technology has its own set of interconnection issues, and these are examined separately for each. The report draws conclusions about each technology's market affinities as defined by factors related to transmission and distribution infrastructure. It finishes with an assessment of selected markets with known geothermal potential, identifying those that offer the best prospects for near-term commercial development and for demonstration projects.

03 NATURAL GAS↗

Cloud Based Applications and Platforms (Presentation)

Presentation to the Cloud Computing East 2014 Conference, where we are highlighting our cloud computing strategy, describing the platforms on the cloud (including Smartgrid.gov), and defining our process for implementing cloud based applications.

97 MATHEMATICS AND COMPUTING↗

Sensitivity Analysis of Occupant Preferences on Energy Usage in Residential Buildings: Preprint

Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand-side management (DSM) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs. It is important to account for occupant preferences in HEMS to ensure occupant satisfaction while participating in DSM programs. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foreseeTM HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful for controlling the electrical grid and developing HEMS solutions.

carbon footprint↗

Vertically Resolved Analysis of the Madden-Julian Oscillation Highlights the Role of Convective Transport of Moist Static Energy

We simulate the Madden-Julian oscillation (MJO) over an aquaplanet with uniform surface temperature using the multiscale modeling framework (MMF) configuration of the Energy Exascale Earth System Model (E3SM-MMF). The model produces MJO-like features that have a similar spatial structure and propagation behavior to the observed MJO. To explore the processes involved in the propagation and maintenance of these MJO-like features, we perform a vertically resolved moist static energy (MSE) analysis for the MJO (Yao et al., 2022, https://doi.org/10.1175/jas-d-20-0254.1). Unlike the column-integrated MSE analysis, our method emphasizes the local production of MSE variance and quantifies how individual physical processes amplify and propagate the MJO's characteristic vertical structure. We find that radiation, convection, and boundary layer (BL) processes all contribute to maintaining the MJO, balanced by the large-scale MSE transport. Furthermore, large-scale dynamics, convection, and BL processes all contribute to the propagation of the MJO, while radiation slows the propagation. Additionally, we perform mechanism-denial experiments to examine the role of radiation and associated feedbacks in simulating the MJO. We find that the MJO can still self-emerge and maintain its characteristic structures without radiative feedbacks. This study highlights the role of convective MSE transport in the MJO dynamics, which was overlooked in the column-integrated MSE analysis.

54 ENVIRONMENTAL SCIENCES↗

Exploring the Tl 2H 2 potential energy surface: A comparative analysis with group 13 systems and experiment

Abstract Thallium chemistry is experiencing unprecedented importance. Therefore, it is valuable to characterize some of the simplest thallium compounds. Stationary points along the singlet and triplet TlH potential energy surface have been characterized. Stationary point geometries were optimized with the CCSD(T)/aug‐cc‐pwCVQZ‐PP method. Harmonic vibrational frequencies were computed at the same level of theory while anharmonic vibrational frequencies were computed at the CCSD(T)/aug‐cc‐pwCVTZ‐PP level of theory. Final energetics were obtained with the CCSDT(Q) method. Basis sets up to augmented quintuple‐zeta cardinality (aug‐cc‐pwCV5Z‐PP) were employed to obtain energetics in order to extrapolate to the complete basis set limits using the focal point approach. Zero‐point vibrational energy corrections were appended to the extrapolated energies in order to determine relative energies at 0 K. It was found that the planar dibridged isomer lies lowest in energy while the linear structure lies highest in energy. The results were compared to other group 13 MH (M = B, Al, Ga, In, and Tl) theoretical studies and some interesting variations are found. With respect to experiment, incompatibilities exist.

Chemistry↗

Higher-order mode analysis at the BNL Energy Recovery Linac

Understanding the prevalence and structure of higher-order modes (HOMs) in accelerator cavities is critical because their excitation can result in problematic single bunch and multi-bunch effects. Particularly hazardous are dipole modes, which are more easily excited due to their linear field nature near the beam center. During a recent superconducting test on the energy recovery linac (ERL) cavity at Brookhaven National Laboratory (BNL), 8 of the highest-Q HOMs were measured for the first time. In conjunction with analysis of CST Microwave Studio simulation results for the ERL model, one of these modes was further studied in the copper prototype ERL cavity. A method of identifying HOMs utilizing existing holes drilled in copper cavity cells was developed and used to conclude that the observed high-Q mode was a quadrupole.

43 PARTICLE ACCELERATORS↗

SU-C-BRE-07: Sensitivity Analysis of the Threshold Energy for the Creation of Strand Breaks and of Single and Double Strand Break Clustering Conditions

Purpose: To analyse the sensitivity of the creation of strand breaks (SB) to the threshold energy (Eth) and thresholding method and to quantify the impact of clustering conditions on single strand break (SSB) and double strand break (DSB) yields. Methods: Monte Carlo simulations using Geant4-DNA were conducted for electron tracks of 280 eV to 220 keV in a geometrical DNA model composed of nucleosomes of 396 phospho-diester groups (PDGs) each. A strand break was created inside a PDG when the sum of all energy deposits (method 1) or energy transfers (method 2) was higher than Eth or when at least one interaction deposited (method 3) or transferred (method 4) an energy higher than Eth. SBs were then clustered into SSBs and DSBs using clustering scoring criteria from the literature and compared to our own. Results: The total number of SBs decreases as Eth is increased. In addition, thresholding on the energy transfers (methods 2 and 4) produces a higher SB count than when thresholding on energy deposits (methods 1 and 3). Method 2 produces a step-like function and should be avoided when attempting to optimize Eth. When SBs are grouped into damage patterns, clustering conditions can underestimated SSBs by up to 18 % and DSBs can be overestimated by up to 12 % compared to our own implementation. Conclusion: We show that two often underreported simulation parameters have a non-negligible effect on overall DNA damage yields. First more SBs are counted when using energy transfers to the PDG rather than energy deposits. Also, SBs grouped according to different clustering conditions can influence reported SSB and DSB by as much as 20%. Careful handling of these parameters is required when trying to compare DNA damage yields from different authors. Research funding from the governments of Canada and Quebec. PP acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Application of HCMM data to regional geologic analysis for mineral and energy resource evaluation

The effects of topographic elevation and slope on thermal images were examined using representative field obstructions of the solar and sky radiation and a simple linearized thermal model. The forms are easily adapted for analysis of HCMM images using the DMA digital terrain data. From a representative set of field observations, it was found that flux variations with elevation can cause changes in the mean diurnal temperature gradient from -4 deg to -14 deg per km evaluated at 2000 m. Changes in the temperature difference gradient of 1 to 2 C per km are also produced which is equivalent to an effective thermal inertia gradient of 100 W s to the 1/2 power/sq m K/1 per km. Exposed bedrock on topographic ridges will appear to have a lower thermal inertia due to the additional effect.

Watson, K.↗