At least 1,585 records · Page 88

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chance-Constrained AC Optimal Power Flow for Distribution Systems With Renewables

This paper focuses on distribution systems featuring renewable energy sources (RESs) and energy storage systems, and presents an AC optimal power flow (OPF) approach to optimize system-level performance objectives while coping with uncertainty in both RES generation and loads. The proposed method hinges on a chance-constrained AC OPF formulation where probabilistic constraints are utilized to enforce voltage regulation with prescribed probability. A computationally more affordable convex reformulation is developed by resorting to suitable linear approximations of the AC power-flow equations as well as convex approximations of the chance constraints. The approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive strategy is then obtained by embedding the proposed AC OPF task into a model predictive control framework. Finally, a distributed solver is developed to strategically distribute the solution of the optimization problems across utility and customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of electron energy distribution functions on plasma generated vacuum ultraviolet in a diffusion plasma excited by a microwave surface wave

Plasma generated vacuum ultraviolet (VUV) in diffusion plasma excited by a microwave surface wave has been studied by using dielectric-based VUV sensors. Evolution of plasma VUV in the diffusion plasma as a function of the distance from the power coupling surface is investigated. Experimental results have indicated that the energy and spatial distributions of plasma VUV are mainly controlled by the energy distribution functions of the plasma electrons, i.e., electron energy distribution functions (EEDFs). The study implies that by designing EEDF of plasma, one could be able to tailor plasma VUV in different applications such as in dielectric etching or photo resist smoothing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Polarized and unpolarized gluon PDFs: Generative machine learning applications for lattice QCD matrix elements at short distance and large momentum

Lattice quantum chromodynamics (QCD) calculations share a defining challenge by requiring a small finite range of spatial separation z between quark/gluon bilinears for controllable power corrections in the perturbative QCD factorization, and a large hadron boost p z for a successful determination of collinear parton distribution functions (PDFs). However, these two requirements make the determination of PDFs from lattice data very challenging. We present the application of generative machine learning algorithms to estimate the polarized and unpolarized gluon correlation functions utilizing short-distance data and extending the correlation up to z p z ≲ 14 , surpassing the current capabilities of lattice QCD calculations. We train physics-informed machine learning algorithms to learn from the short-distance correlation at z ≲ 0.36 fm and take the limit, p z → ∞ , thereby minimizing possible contamination from the higher-twist effects for a successful reconstruction of the polarized gluon PDF. We also expose the bias and problems with underestimating uncertainties associated with the use of model-dependent and overly constrained functional forms, such as x α ( 1 − x ) β and its variants to extract PDFs from the lattice data. We propose the use of generative machine learning algorithms to mitigate these issues and present our determination of the polarized and unpolarized gluon PDFs in the nucleon. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vehicle to Micro-Grid: Leveraging Existing Assets for Reliable Energy Management (Poster)

Fort Carson, a United States Army installation located south of Colorado Springs, Colorado, is seeking to be a net-zero energy facility. As part of this initiative, the base will be constructing a micro-grid that ties to various forms of renewable energy. To reduce petroleum consumption, Fort Carson is considering grid-connected vehicles (GCVs) such as pure electric trucks to replace some of itson-base truck fleet. As the availability and affordability of distributed renewable energy generation options increase, so will the GCV options (currently, three all-electric trucks are available on the GSA schedule). The presence of GCVs on-base opens up the possibility to utilize these vehicles to provide stability to the base micro-grid. This poster summarizes work to estimate the potentialimpacts of three electric vehicle grid interactions between the electric truck fleet and the Fort Carson micro-grid: 1) full-power charging without management, 2) full-power charging capability controlled by the local grid authority, and 3) full-power charge and discharge capability controlled by the local grid authority. We found that even at relatively small adoption rates, the control ofelectric vehicle charging at Fort Carson will aid in regulation of variable renewable generation loads and help stabilize the micro-grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Distributed Energy Resources on Conservation Voltage Reduction (CVR)

Conservation Voltage Reduction (CVR) is one of the cheapest technologies which can be intelligently leveraged to provide considerable energy savings. The addition of renewables in the form of distributed resources can affect the entire power system, but more importantly, affects the traditional substation control schemes at the distribution level. This paper looks at the effect on energy consumption, peak load reduction, and voltage profile changes due to the addition of distributed generation in a distribution feeder using combinations of volt var control. An IEEE 13-node system is used to simulate the various cases. Energy savings and peak load reduction for different simulation scenarios are compared.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

Johnson, Jay Tillay↗

Pulsed D-D Neutron Generator Measurements of HEU Oxide Fuel Pins

Pulsed neutron interrogation measurements have been performed on highly enriched uranium (HEU) oxide fuel pins and depleted uranium (DU) metal using a D-D neutron generator (2x10{sup 6} neutrons-s{sup -1}) and moderated {sup 3}He tubes at the Idaho National Laboratory Power Burst Facility. These measurements demonstrate the ability to distinguish HEU from DU by coincidence counting using a pulsed source. The amount of HEU measured was 8 kg in a sealed 55-gallon drum compared to 31 kg of DU. Neutron events were counted during and after the pulse with the Nuclear Materials Identification System (NMIS) and used to calculate the neutron coincidence time distributions. Passive measurements were also performed for comparison with the pulsed measurements. This paper presents the neutron coincidence time distribution and Feynman variance results from the measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Precise ROCOF estimation algorithm for low inertia power grids

The precise estimation of Rate Of Change Of Frequencies (ROCOFs) in a generation trip event can be helpful on power system inertia estimation, fast system response, and accurate event capturing. However, the ROCOF estimations from the existing Synchronized Measurement Devices (SMDs) are usually simply calculated by the finite difference between two adjacent frequency measurement points. The ineluctable noises, disturbances, and spikes from real-world frequency measurements can bring large dynamics to the ROCOF estimation and thus can result in an inaccurate estimation of the initial ROCOF. This issue becomes more serious when the target power grid has low inertia, and a large amount of distributed energy sources are deployed. To address this issue, a precise ROCOF estimation algorithm is designed based on least square method with flexible window size. In addition, a median filter is also designed and applied on the frequency measurements before using the proposed algorithm. The window size and thresholds in the proposed algorithm are determined with historical event data analysis. The proposed algorithm is deployed in a low cost, flexible, and distribution level universal grid analyzer (UGA) platform. In conclusion, multiple experiments are conducted in both a laboratory and the Hawaiian Islands to verify the effectiveness of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Wind Generation and Load Forecast Uncertainties into Power Grid Operations

In this paper, a new approach to evaluate the uncertainty ranges for the required generation performance envelope, including the balancing capacity, ramping capability and ramp duration is presented. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (CAISO) real life data have shown the effectiveness and efficiency of the proposed approach.

17 WIND ENERGY↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

An improved synthetic signal injection routine for HAYSTAC

Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion-photon conversion is on the order of 10-24 W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful. Here we present a method based on frequency hopping spread spectrum for synthesizing axion signals in a microwave cavity haloscope experiment. It allows us to generate a narrow and asymmetric shape in frequency space that mimics an axion's spectral distribution, which is derived from a Maxwell-Boltzmann distribution. In addition, we show that the synthetic axion's power can be calibrated with reference to the system noise. Compared to the synthetic axion injection in HAYSTAC phase I, we demonstrated synthetic signal injection with a more realistic lineshape and calibrated power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Vision for Co-optimized T&D System Interaction with Renewables and Demand Response

The evolution of the power system to the reliable, effi- cient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. The use of demand response to counterbalance the intermittency of re- newable generation brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distri- bution system, these resources are typically modeled as variables at the transmission network level. In this paper, a vision for co- optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system is described. In this frame- work, microgrids encompass consumers, distributed renewables and storage. The energy management system of the microgrid can also sell (buy) excess (necessary) energy from the transmission system. Preliminary work explores price mechanisms to manage the microgrid and its interactions with the transmission system. Wholesale market operations are addressed through the devel- opment of scalable stochastic optimization methods that provide the ability to co-optimize interactions between the transmission and distribution systems. Modeling challenges of the co-optimization are addressed via solution methods for large-scale stochastic op- timization, including decomposition and stochastic dual dynamic programming.

14 SOLAR ENERGY↗

Quantitative Thermal Imaging of Single-Walled Carbon Nanotube Devices by Scanning Joule Expansion Microscopy

Electrical generation of heat in single-walled carbon nanotubes (SWNTs) and subsequent thermal transport into the surroundings can critically affect the design, operation, and reliability of electronic and optoelectronic devices based on these materials. Here we investigate such heat generation and transport characteristics in perfectly aligned, horizontal arrays of SWNTs integrated into transistor structures. We present quantitative assessments of local thermometry at individual SWNTs in these arrays, evaluated using scanning Joule expansion microscopy. Measurements at different applied voltages reveal electronic behaviors, including metallic and semiconducting responses, spatial variations in diameter or chirality, and localized defect sites. Furthermore, analytical models, validated by measurements performed on different device structures at various conditions, enable accurate, quantitative extraction of temperature distributions at the level of individual SWNTs. Using current equipment, the spatial resolution and temperature precision are as good as ~100 nm and ~0.7 K, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient stability and control of renewable generators based on Hamiltonian surface shaping and power flow control. Part II, analysis.

The swing equations for renewable generators connected to the grid are developed and a wind turbine is used as an example. The swing equations for the renewable generators are formulated as a natural Hamiltonian system with externally applied non-conservative forces. A two-step process referred to as Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) is used to analyze and design feedback controllers for the renewable generators system. This formulation extends previous results on the analytical verification of the Potential Energy Boundary Surface (PEBS) method to nonlinear control analysis and design and justifies the decomposition of the system into conservative and non-conservative systems to enable a two-step, serial analysis and design procedure. The first step is to analyze the system as a conservative natural Hamiltonian system with no externally applied non-conservative forces. The Hamiltonian surface of the swing equations is related to the Equal-Area Criterion and the PEBS method to formulate the nonlinear transient stability problem. This formulation demonstrates the effectiveness of proportional feedback control to expand the stability region. The second step is to analyze the system as natural Hamiltonian system with externally applied non-conservative forces. The time derivative of the Hamiltonian produces the work/rate (power flow) equation which is used to ensure balanced power flows from the renewable generators to the loads. The Second Law of Thermodynamics is applied to the power flow equations to determine the stability boundaries (limit cycles) of the renewable generators system and enable design of feedback controllers that meet stability requirements while maximizing the power generation and flow to the load. Necessary and sufficient conditions for stability of renewable generators systems are determined based on the concepts of Hamiltonian systems, power flow, exergy (the maximum work that can be extracted from an energy flow) rate, and entropy rate. This paper will present the analysis and numerical simulation results for two nonlinear control design examples that include: (1) the One-Machine Infinite Bus (OMIB) system with a Unified Power Flow Controller (UPFC) and (2) the swing equation for a wind turbine connected to an infinite bus through a UPFC to determine the required performance of the UPFC to enable the maximum power output of a wind turbine subject to stochastic inputs while meeting the power system constraints on frequency and phase. The energy storage requirements will also be identified from the UPFC and/or FACTS devices while working in combination with the wind turbine.