Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Supersonic compressor

A supersonic compressor including a rotor to deliver a gas at supersonic conditions to a diffuser. The diffuser includes a plurality of aerodynamic ducts that have converging and diverging portions, for deceleration of gas to subsonic conditions and then for expansion of subsonic gas, to change kinetic energy of the gas to static pressure. The aerodynamic ducts include vortex generating structures for controlling boundary layer, and structures for changing the effective contraction ratio to enable starting even when the aerodynamic ducts are designed for high pressure ratios, and structures for boundary layer control. In an embodiment, aerodynamic ducts are provided having an aspect ratio of in excess of two to one, when viewed in cross-section orthogonal to flow direction at an entrance to the aerodynamic duct.

42 ENGINEERING↗

Density Effects on Lock Exchange Flow During a DCC

The High Temperature Test Facility (HTTF) is a scaled, electric model at Oregon State University (OSU) of the Modular High Temperature Gas Reactor (MHTGR) by General Atomics. There are a few major differences between the design and the OSU facility. In the HTTF the reactor pressure vessel and the reactor cavity are in two separate tanks connected by a crossover duct similar to the crossover duct that would be seen between the reactor core and the steam generator in the MHTGR. This feature allows for the facility to open two main break valves simulating a Double-Ended Guillotine Break (DEGB) of the cross over duct, synonymous to a crossover duct break in the MHTGR. The density gradient driven flow phenomena in the HTTF duct can then be studied further. This break would cause a depressurization of the reactor and a loss of flow. It is called the Depressurized Loss of Forced Convection Accident (D-LOFC), also known as the Depressurized Conduction Cool-Down Event for High Temperature Gas Reactors (HTGRs) because heat removal is by conduction through the core and radiation out of the vessel. The HTTF was built and scaled to maintain the highest accuracy for the DCC. Prototypical temperatures with an inlet temperature of 259 deg. C and an outlet temperature of 687 deg. C are maintained in the HTTF. The temperature profile is also maintained in the smaller volume by using a ceramic core. The HTTF uses graphite heaters because the resistive heat produced does not change significantly with temperature . In order to produce a facility of similar temperatures within the allotted budget, sacrifices had to be made in other areas. The HTTF is scaled one-fourth in diameter, one-fourth in height and one-eighth in pressure of the MHTGR. There are also a few limitations for the HTTF. While in the MHTGR, the cavity is filled with air, the HTTF uses highly pure Nitrogen and does not have the ability to simulate a full depressurization. The DCC event is traditionally comprised of multiple stages: depressurization, molecular diffusion and natural circulation. However, this traditional interpretation ignores lock exchange flow which will occur immediately following depressurization and could have significant consequences in the reactor. It was found that the traditional model underestimates the amount of air ingress by at least 660 times according to Oh and Kim in their theoretical research of air ingress. Molecular diffusion also decreases with stratification. Any model that specifies the gases are stratified has further underestimated the air ingress of the DCC event. In addition, molecular diffusion is a much slower process, allowing the reactor to shut down and cool off considerably from operating temperatures. Thus, understanding lock exchange flow, the air ingress concentrations and the time scale is critical to MHTGR research and licensing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coupled Neutron and Gamma Heating Calculation Based on VARIANT Nodal Transport Method

Accurate determination of temperature distributions in fuel pins and duct walls is essential for fuel-pin performance and assembly bowing analyses. Currently, the multi-assembly, sub-channel analysis code SE2-ANL is used in thermalhydraulic analysis of sodium cooled fast reactors (SFR). SE2- ANL is interfaced with the DIF3D/GAMSOR/DIF3D procedure for coupled neutron and gamma heating calculations, developed at Argonne National Laboratory (ANL). In this procedure, the neutron flux distribution is first calculated using the finite-difference diffusion theory option of the DIF3D code. Using the neutron flux solution, the GAMSOR code computes the gamma source distribution for the subsequent gamma flux calculation with DIF3D. However, in the current heating calculation scheme, the neutron and gamma flux calculations are limited to six triangular meshes per hexagonal assembly. In addition, the pin power distributions are estimated by assuming that the power distribution within an assembly is separable in the radial and axial directions. In each assembly, the axial power profile is obtained by averaging the power densities of six triangular meshes at each axial mesh interval. The radial power profile is evaluated at a single axial mesh (e.g., at the core mid-plane) by approximating the neutron and gamma flux distributions by a linear or quadratic polynomial of two variables x and y, depending on the polynomial order specified by the user. The coefficients of the linear and quadratic polynomials are determined by the least squares fit of six and 24 triangular mesh fluxes, respectively. Furthermore, the total heat generation rate in an assembly duct wall is simply determined by a user-specified fraction of the total gamma heating within that assembly. With the advancement of computer technology, the nodal transport theory code VARIANT is routinely used in core design analyses of SFR instead of DIF3D. It is therefore necessary to develop a new heating calculation procedure based on VARIANT neutron and gamma transport calculations. In this study, a new, coupled neutron and gamma heating calculation scheme has been developed to determine the pin power distributions more accurately by eliminating the aforementioned limitations of the current procedure. For this, the GAMSOR code has been extended to generate the intra-nodal gamma source distribution to be consistent with the trial functions of VARIANT. In the new heating calculation procedure, the neutron flux distribution is determined first by solving an eigenvalue transport problem using VARIANT. The obtained neutron flux is then used in GAMSOR to calculate the gamma source distribution. Using this gamma source distribution, the gamma flux distribution is determined by solving a fixed-source transport problem using VARIANT again. Using the computed neutron and gamma flux distributions, the power distribution in each fuel pin and duct wall is determined using a new utility code CURVE, which has been developed to evaluate the VARIANT flux solution at each fuel pin position and along the duct mid-wall. For each pin segment contained in a VARIANT node, the axial power shape is represented as a quadratic profile. The performance of the new heating calculation scheme based on VARIANT transport solutions has been tested against the existing method of SE2-ANL, using the ABR-1000 metal core design. The gamma source distribution and the assembly, fuel pin and duct wall power distributions were calculated and compared. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CFD Verification and Validation of Wire-Wrapped Pin Assemblies

TerraPower is participating in a cooperative project among industry, the national lab system, and academia to perform Verification and Validation (V and V) of Computational Fluid Dynamics (CFD) methods for predicting the flow and heat transfer within liquid-metal-cooled nuclear fuel assemblies with wire-wrapped fuel pins. This project, consisting of both experimental and numerical components, uses surrogate fluids and electrically heated fuel pins to substitute for the liquid metal coolant and the nuclear heat source. The experiments include both unheated assemblies to measure the flow velocities with Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV), as well as heated assemblies to measure the temperatures of the fluid and the simulated fuel pins with thermocouples. Both sets of experiments also measure the pressure at multiple locations in the system. The numerical component of this work involves high-fidelity Large-Eddy Simulation (LES) modeling and industry-standard Reynolds-Averaged Navier-Stokes (RANS) modeling of the experiments. Furthermore, the experiments and simulations will be conducted on two duct geometries: the first is a non-deformed hexagonal duct that has flat internal duct faces that represents a beginning of life geometry. The other is a deformed duct where the internal hexagonal flow area enlarges then decreases along the axial height to represent the changes that occur to the duct geometry from pressure and irradiation effects in the core. This paper describes the methods and results of the industrial, RANS-based CFD code verification, solution verification, and solution validation. The V and V simulations are being performed for the following experiment test geometries: - Isothermal non-deformed bundle; - Heated non-deformed bundle; - Isothermal deformed bundle; - Heated deformed bundle. These flows have been computed at first with the pre-test design specifications, without the aid of any experimental results. Later, post-test calculations will be performed incorporating the actual test conditions and input from some of the experimental results. These RANS simulations of helically wire-wrapped fuel assemblies employ meshes of bare pins without the wire-wrap in the bundle. The effect of wire-wrap on the flow is accounted for by introducing a momentum source into the governing fluid equations. The momentum source is only applied to cells corresponding to the location of the wire-wrap, and its components in each cell are based on the local flow field. This methodology simplifies the geometry and mesh generation and reduces the cell count, while still capturing the effects of the wire-wrap. The momentum source approach is used for all of the assembly simulations performed in this study. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstration and Verification of Thermo-Mechanical Bowing in a Limited Free-Bow SFR Concept Using MOOSE

Core bowing due to thermal gradients and irradiation induced swelling and creep introduces significant reactivity feedback effects in liquid metal-cooled fast spectrum reactors. During startup, normal operations, and transient events, differential thermal and flux gradients cause expansion, creep, and swelling, which results in bowing in preferential directions depending on local material properties and load-pad and restraint-ring design. The bowing phenomenon produces negative reactivity during accident conditions provided the restraint system has been properly designed to optimally guide the deformation outwards in the active core region. Under the Department of Energy Nuclear Energy Advanced Modeling and Simulation program, a Multiphysics Object Oriented Simulation Environment (MOOSE)-based multiphysics approach to model core bowing is being developed. The present work expands on previous modeling of simpler International Atomic Energy Agency (IAEA) verification problems with these tools by modeling IAEA Verification Problem 4, which involves a symmetric sector of a reactor core with ducted assemblies undergoing differential thermal expansion due to thermal gradients bowing outward with duct-to-duct contact. This model is available on the National Reactor Innovation Center Virtual Test Bed repository. This example was verified against benchmark participant results, which includes bowing deformation evaluation and duct-to-duct interactions at load pads with mechanical contact.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of the Group 5-6 (LB C2, LB S2, LV S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1 1999

This document reports on a series of tests to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 5-6 exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LB-C2, LV-S1, and LB S2 exhaust stacks were tested together as a group (Test Group 5-6) because the common factor in their design is that the last significant flow disturbance upstream of the air sampling probe is a reduction in duct diameter. Federal regulations( ) require that a sampling probe be located in the exhaust stack according to the criteria of the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The testing on scale models of the stacks conducted for this project was part of the River Protection Project—Waste Treatment Plant Support Program under Contract No. DE-AC05-76RL01830 according to the statement of work issued by Bechtel National Inc. (BNI, 24590-QL-SRA-W000-00101, N13.1-1999 Stack Monitor Scale Model Testing and Qualification, Revision 1, 9/12/2007) and Work Authorization 09 of Memorandum of Agreement 24590-QL-HC9-WA49-00001. The internal Pacific Northwest National Laboratory (PNNL) project for this task is 53024, Work for Hanford Contractors Stack Monitoring. The testing described in this document was further guided by the Test Plan Scale Model Testing the Waste Treatment Plant LB-C2, LB-S2, and LV-S1 (Test Group 5-6) Stack Air Sampling Positions (TP-RPP-WTP-594). The tests conducted by PNNL during 2009 and 2010 on the Group 5-6 scale model systems are described in this report. The series of tests consists of various measurements taken over a grid of points in the duct cross-section at the designed sampling probe locations and at five duct diameters up and downstream from the design location to accommodate potential construction variability. The tests were done only at the design sampling probe location on the scale model of LB-S2 because that ductwork was already constructed. The ANSI/HPS N13.1-1999 criteria and the corresponding results of the test series on the scale models are summarized in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANNULUS CLOSURE TECHNOLOGY DEVELOPMENT INSPECTION/SALT DEPOSIT CLEANING MAGNETIC WALL CRAWLER

The Liquid Waste Technology Development organization is investigating technologies to support closure of radioactive waste tanks at the Savannah River Site (SRS). Tank closure includes removal of the wastes that have propagated to the tank annulus. Although amounts and types of residual waste materials in the annuli of SRS tanks vary, simple salt deposits are predominant on tanks with known leak sites. This task focused on developing and demonstrating a technology to inspect and spot clean salt deposits from the outer primary tank wall located in the annulus of an SRS Type I tank. The Robotics, Remote and Specialty Equipment (RRSE) and Materials Science and Technology (MS&T) Sections of the Savannah River National Laboratory (SRNL) collaborated to modify and equip a Force Institute magnetic wall crawler with the tools necessary to demonstrate the inspection and spot cleaning in a mock-up of a Type I tank annulus. A remote control camera arm and cleaning head were developed, fabricated and mounted on the crawler. The crawler was then tested and demonstrated on a salt simulant also developed in this task. The demonstration showed that the camera is capable of being deployed in all specified locations and provided the views needed for the planned inspection. It also showed that the salt simulant readily dissolves with water. The crawler features two different techniques for delivering water to dissolve the salt deposits. Both water spay nozzles were able to dissolve the simulated salt, one is more controllable and the other delivers a larger water volume. The cleaning head also includes a rotary brush to mechanically remove the simulated salt nodules in the event insoluble material is encountered. The rotary brush proved to be effective in removing the salt nodules, although some fine tuning may be required to achieve the best results. This report describes the design process for developing technology to add features to a commercial wall crawler and the results of the demonstration testing performed on the integrated system. The crawler was modified to address the two primary objectives of the task (inspection and spot cleaning). SRNL recommends this technology as a viable option for annulus inspection and salt removal in tanks with minimal salt deposits (such as Tanks 5 and 6.) This report further recommends that the technology be prepared for field deployment by: (1) developing an improved mounting system for the magnetic idler wheel, (2) improving the robustness of the cleaning tool mounting, (3) resolving the nozzle selection valve connections, (4) determining alternatives for the brush and bristle assembly, and (5) adding a protective housing around the motors to shield them from water splash. In addition, SRNL suggests further technology development to address annulus cleaning issues that are apparent on other tanks that will also require salt removal in the future such as: (1) Developing a duct drilling device to facilitate dissolving salt inside ventilation ducts and draining the solution out the bottom of the ducts. (2) Investigating technologies to inspect inside the vertical annulus ventilation duct.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The development and initial testing of the Ice Pig cleaning method for nuclear reprocessing plants - 15363

There are numerous situations throughout the nuclear industry where it would be advantageous to clean out enclosed systems, e.g. ducts and pipes, to remove sediments and radioactive contamination. However, conventional flushing methods result in the production of significant volumes of contaminated liquor. The wall Shear achieved with water flushing is insufficient to remove and carry dense deposits often found in nuclear facilities. Conventional mechanical pigs can be propelled through the duct by application of a driving medium such as compressed air or water. These are able to achieve very high wall shears, but can also get physically stuck where there is variation in the pipe / duct diameter or small radius bends. The field of application is best suited to straight constant diameter systems with no discontinuities such as Tee pieces, valves and in-pipe instrumentation. Driven by the desire to clean and displace radioactive materials from complex topology ducts and pipes, without the risk of having conventional pigs becoming lodged in a plant and coupled with the need to minimize effluent volumes, the UK Nuclear Industry led by Sellafield Limited (on behalf of the UK Nuclear Decommissioning Authority), has worked to demonstrate and underpin the use of the ice pigging technology for the nuclear industry. It is found that high ice fraction slurries flow as viscous liquids that exhibit a number of mechanical properties that offer much higher shear rates. The 'Ice Pig' exerts shear rates on pipe walls which are typically 1000 times greater than those achieved with water flowing at the same velocity. The 'Ice Pig' is able to negotiate almost any topology, flow through pipe networks of vastly differing diameter, through heat exchangers and in-line instrumentation etc. Experimental data and operational experience from other industries demonstrates that whilst there is high shear, the 'Ice Pig' does not damage the surface of the pipe wall. A further attractive characteristic of the 'Ice Pig' is that it eventually melts rendering it a simple effluent for processing by downstream processes. Due to the special nature of ice slurry, its unique rheological and physical characteristics, together with the complementary underpinning experimental work undertaken by Sellafield Limited enables the Ice Pigging process to move from an 'interesting' technology to one suitable for use by the nuclear industry for operations, Post Operational Clean Out (POCO) and decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Distribution Retrofit Strategies for Affordable Housing

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Distribution Retrofit Strategies for Affordable Housing

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $\$$275 to $\$$511 per unit and for the injected spray sealant the cost was $\$$700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differences in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of software models for energy savings from cool roofs

For this study, a web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. RSC simulates multiple roof and attic technologies for side-by-side comparison including reflective roofs, different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. Annual simulations of hour-by-hour, whole-building performance are used to provide estimated annual energy and cost savings from reduced HVAC use. While RSC reported similar cooling savings to other simulation engines, heating penalty varied significantly. RSC results show reduced cool roofing cost-effectiveness, thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC's projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus. Also included are comparisons to previous simulation-based studies, analysis of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model. Finally, radiant heat transfer and duct interaction not previously modeled is considered a major contributor to heating penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct numerical simulation of flame stabilization assisted by autoignition in a reheat gas turbine combustor

A three-dimensional direct numerical simulation (DNS) is performed for a turbulent hydrogen-air flame, represented with detailed chemistry, stabilized in a model gas-turbine combustor. The combustor geometry consists of a mixing duct followed by a sudden expansion and a combustion chamber, which represents a geometrically simplified version of Ansaldo Energia’s GT26/GT36 sequential combustor design. In this configuration, a very lean blend of hydrogen and vitiated air is prepared in the mixing duct and convected into the combustion chamber, where the residence time from the inlet of the mixing duct to the combustion chamber is designed to coincide with the ignition delay time of the mixture. The results show that when the flame is stabilized at its design position, combustion occurs due to both autoignition and flame propagation (deflagration) modes at different locations within the combustion chamber. A chemical explosive mode analysis (CEMA) reveals that most of the fuel is consumed due to autoignition in the bulk-flow along the centerline of the combustor, and lower amounts of fuel are consumed by flame propagation near the corners of the sudden expansion, where the unburnt temperature is reduced by the thermal wall boundary layers. An unstable operating condition is also identified, wherein periodic auto-ignition events occur within the mixing duct. These events appear upstream of the intended stabilization position, due to positive temperature fluctuations induced by pressure waves originating from within the combustion chamber. This DNS investigation represents the initial step of a comprehensive research effort aimed at gaining detailed physical insight into the rate-limiting processes that govern the sequential combustor behavior and avoid the insurgence of the off-design auto-ignition events.

20 FOSSIL-FUELED POWER PLANTS↗

Toward full simulations for a liquid metal blanket: part 2. Computations of MHD flows with volumetric heating for a PbLi blanket prototype at Ha ~10 4 and Gr ~10 12

On the pathway toward full simulations for a liquid metal (LM) blanket, this part 2 extends a previous study of purely magnetohydrodynamic (MHD) flows in a DCLL blanket in reference Chen et al (2020 Nucl. Fusion 60 076003) to more general conditions when the MHD flow is coupled with heat transfer. The simulated prototypic blanket module includes all components of a real LM blanket system, such as supply ducts, inlet and outlet manifolds, multiple poloidal ducts and a U-turn zone. Volumetric heating generated by fusion neutrons is added to simulate thermal effects in the flowing lead–lithium (PbLi) breeder. The MHD flow equations and the energy equation are solved with a DNS-type finite-volume code ‘MHD-UCAS’ on a very fine mesh of 470 × 10 6 cells. The applied magnetic field is 5 T (Hartmann number Ha ~ 10 4 ), the PbLi velocity in the poloidal ducts is 10 cm s –1 (Reynolds number Re ~10 5 ), whereas the maximum volumetric heating is 30 MW m –3 (Grashof number Gr ~ 10 12 ). Four cases have been simulated, including forced- and mixed-convection flows, and either an electrically conducting or insulating blanket structure. Various comparisons are made between the four computed cases and also against the purely MHD flows computed earlier in reference Chen et al (2020 Nucl. Fusion 60 076003) with regards to the (1) MHD pressure drop, (2) flow balancing, (3) temperature field, (4) flows in particular blanket components, and (5) 3D and turbulent flow effects. The strongest buoyancy effects were found in the poloidal ducts. In the electrically non-conducting blanket, the buoyancy forces lead to significant modifications of the flow structure, such as formation of reverse flows, whereas their effect on the MHD pressure drop is relatively small. In the electrically conducting blanket case, the buoyancy effects on the flow and MHD pressure drop are almost negligible.

Physics↗

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗