Vulnerability of the US western electric grid to hydro-climatological conditions: How bad can it get?
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Transportation electrification is forecast to bring millions of new electric vehicles to roads worldwide this decade. Planning to support those vehicles depends on detailed scenarios of their electricity demand in both uncontrolled and controlled or smart charging scenarios. In this work, we present a novel modeling approach to enable rapid generation of demand estimates that represent the impact of controlled charging for large-scale scenarios with millions of individual drivers. To model the effect of load modulation control on aggregate charging profiles, we propose a novel machine learning approach that replaces traditional optimization approaches. We demonstrate its performance modeling workplace charging control under a range of electricity rate schedules, achieving small errors (2.5%–4.5%) while accelerating computations by more than 4000 times. To generate the uncontrolled charging demand for scenarios with residential, workplace, and public charging we use statistical representations of a large data set of real charging sessions. We demonstrate the methodology by generating diverse sets of scenarios for California's charging demand in 2030 which consider multiple charging segments and controls, each run locally in under 50 s. We further demonstrate support for rate design by modeling the large-scale impact of a new, custom rate schedule for workplace charging.
Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.
Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.
Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.
The Chinese government has pledged to achieve overall carbon neutrality by 2060. Currently, the transportation sector contributes to about 10% of total greenhouse gas (GHG) emissions in China. Hence, China has created a well-defined energy vehicle development strategy to reduce GHG emissions from the transportation sector, further expanding into hydrogen vehicle technologies. In this study, the Transportation Energy Analysis Model (TEAM) investigates the potential of hydrogen internal combustion engine vehicles (H2- ICEVs) and fuel cell vehicles (FCEVs) as a reliable pathway towards the government's aspiration of carbon neutrality in the transportation sector. According to TEAM, by adopting FCEVs and H2-ICEVs in the vehicle market, hydrogen demand could reach 25% of the total light-duty transportation energy demand in 2050. Consequently, this will lead to an annual reduction of more than 35 million tons GHG compared to only counting on the electrification pathway in the decarbonization task. Besides, FCEVs would take longer to penetrate the light-duty vehicle market compared to H2-ICEVs, as the current fuel cell technology still requires much improvement to attain a competitive vehicle cost of production.
A growing hydrogen economy requires new hydrogen distribution infrastructure to link geographically distributed hubs of supply and demand. The Hydrogen Optimization with Deployment of Infrastructure (HOwDI) Model helps meet this requirement. The model is a spatially resolved optimization framework that determines location-specific hydrogen production and distribution infrastructure to cost-optimally meet a specified location-based demand. While these results are useful in understanding hydrogen infrastructure development, there is uncertainty in some costs that the model uses for inputs. Thus, the project team took the modeling effort a step further and developed a Monte Carlo methodology to help manage uncertainties. Seven scenarios were run using existing infrastructure and new demand in Texas exploring different policy and tax approaches. The inclusion of tax credits increased the percentage of runs that could deliver hydrogen at <$\$4$ /kg from 31% to 77% and decreased the average dispensed cost from $\$4.35$ /kg to $\$3.55$ /kg. However, even with tax credits there are still some runs where unabated SMR is deployed to meet new demand as the low-carbon production options are not competitive. Every scenario, except for the zero-carbon scenario (without tax credits), resulted in at least 20% of the runs meeting the $\$4$ /kg dispensed fuel cost target. This indicates that multiple pathways exist to deliver $\$4$ /kg hydrogen.
Medium and heavy-duty freight transportation requires hydrogen energy infrastructure that is cost-effective, operationally reliable, spatially coherent, and resilient to demand variability along major corridors. This paper presents an integrated hydrogen corridor planning framework using Oak Ridge National Laboratory's OR-AGENT that couples freight-driven, route-resolved hydrogen demand modeling with optimized station siting, sizing, and station-level techno-economic analysis. The framework is demonstrated for the Interstate 10 freight corridor and the Houston-to-Los-Angeles region. Hydrogen demand is derived from high-resolution origin–destination freight data, duty-cycle characterization, and physics-based energy consumption modeling. Candidate refueling sites are selected from existing heavy-duty diesel fueling locations and optimized subject to onboard storage and station capacity constraints. Resulting station throughputs are evaluated using established techno-economic models for electrolytic hydrogen production and dispensing infrastructure. Results show that a regional, portfolio-level aggregation, average dispensed electrolytic hydrogen cost of $6.87–$7.26/kg is currently feasible, and is strongly influenced by demand density and utilization.
This report assesses the scale of public fast charging needed to electrify approximately 20,000 vehicles across the yellow cab and for-hire segments in New York City. The analysis considers real-world trip data in conjunction with driver home locations, overnight charging access rates, driver schedules, and more. Outcomes indicate that the existing charging network in New York City is not adequate even in the most optimistic scenario; 1,054 150-kW ports are required when 15% of drivers have access to overnight charging, whereas 367 150-kW ports are needed when 100% of drivers have access. Results also indicate that although charging is demanded in areas nearby high trip demand, fast charging ports are also demanded in areas near driver residences as a supplement for home charging in scenarios with limited overnight charging access. These findings motivate investment into both overnight charging and public fast charging to meet the charging demands of ride-hailing fleets.
Accelerating energy technology development will increase demand for critical raw materials, such as gallium, that enable clean energy technologies. Processing of gallium is concentrated in mainland China (98 % of global production in 2023), resulting in high supply risks for importing countries. To investigate pathways for more resilient supply, we develop a material flow analysis and apply it to the United States, showing the impacts of future domestic primary raw material production and end-of-life (EoL) product recycling on reducing import reliance of raw gallium metal. We complement this analysis with a techno-economic assessment of North American gallium production costs under various demand growth scenarios. Our results indicate that sufficient domestic feedstocks exist to meet U.S. demand under most scenarios by 2035, while EoL recycling can supply up to 50 % under a low-demand growth scenario. Domestic primary production shows significant cost advantages over gallium recycling.
Wastewater treatment plants (WWTPs) consume significant amount of energy to sustain their operation. From this point, the current study aims to enhance the capacity of these facilities to meet their energy needs by integrating renewable energy sources. The study focused on the investigation of two primary solar energy systems in As Samra WWTP in Jordan. The first system combines parabolic trough collectors (PTCs) with thermal energy storage (TES). This system primarily serves to fulfill the thermal energy demands of the plant by reducing the demands from boiler units, which allows more biogas for electricity generation. The second system is a photovoltaic (PV) system with Lithium-Ion batteries, which directly produces electricity that will be used to cover part of the electrical energy demands of plant. To assess the optimal configuration, two distinct scenarios have been formulated and compared to the current case scenario (SC#1). The first scenario focuses on maximizing the net present value (NPV) and minimizing the levelized cost of electricity (LCOE). The second scenario is centred on minimizing the levelized cost of heat (LCOH). The findings indicate that both scenarios succeeded in reducing the reliance on the grid to a value that reach 1 %. Moreover, they both reduced biogas percentage in energy production from 88 % to approximately 65 % through the integration of the PV system. In terms of thermal demand, SC#2 reduced the reliance on biogas boiler units from 100 % to 25 %, while SC#3 achieved an even more impressive reduction to just 8 %. The best LCOE value was attained in SC#2, at 0.0895 USD/kWh, with an NPV of 10.54 million USD. Conversely, SC# 3 yielded an LCOH value of 0.0432 USD/kWh th compared to 0.0534 USD/kWh th USD for SC#2. In conclusion, despite their relatively high capital and operating costs, SC#2 and SC#3 managed to substantially decrease the annual electricity expenditure from approximately 2 million USD to 86,000 USD and 0 USD, respectively.
Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.
The data presented indicate that modest attention to the chemistry of the electrode rinse solution can yield as much as 56% improvement in process efficiency. When operating electrodialysis (ED) with salt concentrations greater than 10,000 mg/l (as NaCl) the amperage can be relatively high even at low voltages. To maximize the overall rate of ion transport from diluate to concentrate, there is a need to minimize resistances in the electrode cells since these can represent as much as 30% of the total resistances in the entire process and in this particular ED unit, represented resistance roughly equivalent to that within the membrane stack. This work describes the performance of a 10-cell pair, 200 cm 2 (0.02 m 2 ) per membrane, pilot ED unit operated in batch mode at 5 V potential. The feedstock to the stack was varied from 0.5% to 6% NaCl. Results from Volt-amp profiles (2.0–15 V) were used as the rationale for choosing the preferred electrode rinse solution, 90 g/l (kg/m 3 ) disodium sulfate at pH 12.5. The recommended solution of 30 g/l (kg/m 3 ) disodium sulfate at neutral pH was tested against stronger solutions (60, 90, and 120 g/l (kg/m 3 ) disodium sulfate) at neutral pH and with 1 g/l (kg/m 3 ) sodium hydroxide added to yield solutions at pH 12.5. There were stark differences in the performance of the ED unit between the solutions at pH 7 and those at pH 12.5. The slopes of the Volt-amp profiles improved indicating less resistance to ion flow at pH 12.5. Most of the difference can be attributed to the greater conductivity of sodium hydroxide compared to disodium sulfate, where even a modest addition of 1 g/l (kg/m 3 ) sodium hydroxide increased the conductivity of the solution between 8 and 20% depending on the concentration of disodium sulfate. Most notably, the initiation voltage was 2.39 ± 0.08 V with solutions at pH 7 and 1.99 V ± 0.04 V when the rinse solutions were around pH 12.5, a difference of around 0.42 V. Since the full batch runs were performed at 5.0 V, this 0.42 V differential represented a loss of 8% in process efficiency. A series of tests showed a shift in initiation voltage occurred between pH 11.5 and 12.5. Nernst equations for water electrolysis are coupled with a simple flux model that estimates the concentration of hydroxide and hydronium ions at the electrode surfaces. This model indicates that the potential demanded by the electrodes is directly linked to the current. Furthermore, there is a steep drop in the potential demanded by the anode when there is sufficient hydroxide available to generate oxygen from hydroxide as opposed to generation from water. The voltage demand is minimal at pH 12.5 and reflective of the reference standard voltage (just over 1.23 V predicted at 0.1 amps). However, the flux model predicts that the voltage demanded by the electrodes at pH 7 is 1.61 V at 0.1 amps (the lowest amperage measurable with the power pack). In conclusion, comparing this result to the reference standard (E 0 = -1.23 V) yields a satisfactory explanation for the observed difference below reference standard of 0.42 V.
Emerging mobility technologies are changing the transportation system landscape. This is especially evident at airports, such as the Dallas-Fort Worth International Airport (DFW). Without careful analysis, these changes could lead to inefficient and costly airport operations. This paper presents a modeling framework that integrates travel mode encoding, demand projection, and microsimulation to enable airports to develop, simulate, and evaluate curbside traffic managements policies and measure their impact. Here, the framework is utilized to analyze several traffic scenarios and policies for DFW: a baseline scenario which represents DFW traffic pattern as observed in 2018 and projected to 2045, a transit network company (TNC) electrification policy, a TNC queuing policy, a policy that increased transit ridership, a bus-only policy which considers the use of only buses inside DFW, an autonomous vehicle (AV) policy which investigates the impact of autonomous vehicle (AV) adoption on airport operations, and an example COVID-19 scenario which models the impact of the COVID19 pandemic. The simulations’ results demonstrate that: increasing the DFW transit ridership postpones the need for airport curbside expansion the most; encouraging shared-mobility with the bus-only policy produces the most savings in curbside congestion delays; automation and electrification for all passenger vehicle trips to/from DFW generates the most saving in fuel consumption and emissions; and uncontrolled AV adoption incurs the highest increase in fuel consumption, delay, and emissions and could require immediate airport capacity extension. Without policy intervention or investment in additional infrastructure capacity, these results predict the current operations would face significant congestion on high demand days starting as early as 2028. While derived in close partnership with DFW, the methodology presented here can be generalized to any airport.
Society increasingly demands the stable provision of ecosystem resources to support our population. Resource risks from climate-driven disturbances--including drought, heat, insect outbreaks, and wildfire--are rising as a chronic state of disequilibrium results from increasing temperatures and a greater frequency of extreme events. This confluence of increased demand and risk may soon reach critical thresholds. We explain here why extreme chronic disequilibrium of ecosystem function is likely to increase dramatically across the globe, creating no-analog conditions that challenge adaptation. We also present novel mechanistic theory that combines models for disturbance mortality and metabolic scaling to link size-dependent plant mortality to changes in ecosystem stocks and fluxes. Efforts must anticipate and model chronic ecosystem disequilibrium to properly prepare for resilience planning.
We present a simple method to estimate the maximum possible electrical energy saving that might be achieved by increasing the albedo of surfaces in a large city. We restrict this to the “indirect effect”, the cooling of outside air that lessens the demand for air conditioning (AC). Given the power demand of the electric utilities and data about the city, we can use a single linear equation to estimate the maximum savings. For example, the result for an albedo change of 0.2 of pavements in a typical warm city in California, such as Sacramento, is that the saving is less than about 2 kWh per m2 per year. This may help decision makers choose which heat island mitigation techniques are economical from an energy-saving perspective.
Formic acid (53 g H2/liter) is a promising liquid storage and delivery option for hydrogen for fuel cell power applications. In this work we compare and evaluate several process options using formic acid for energy storage. Each process requires different steps, which contribute to the overall energy demand. The first step, i.e. production of formic acid, is thermodynamically unfavorable. However, the energy demand can be reduced if a formate salt is produced via a bicarbonate route instead of forming the free acid from hydrogen and carbon dioxide. This bicarbonate / formate approach also turns out to be comparatively more efficient in terms of hydrogen release than the formic acid route. Even though less energy efficient, catalytic decomposition of formic acid has the advantage of reaching higher volumetric power densities during hydrogen release. Efficiencies of all process options involve aqueous media and are dependent on concentration. Heating water leads to additional energy demand for hydrogen release and thus lowers the overall efficiency. Separation and purification of hydrogen contributes a minor impact to the overall energy demand. However, its effect on efficiency is not negligible. Other process options like thermal decomposition of formic acid or direct formic acid fuel cells thus far do not appear competitive.
The electric power sector in the United States faces many challenges related to climate change. On the demand side, climate change could shift demand patterns due to increased air temperatures. On the supply side, climate change could lead to deratings of thermal units due to changes in air temperature, water temperature, and water availability. Past studies have typically analyzed these risks separately. Here, we developed an integrated, multimodel framework to analyze how compounding risks of climate-change impacts on demand and supply affect long-term planning decisions in the power system. In the southeast U.S., we found that compounding climate-change impacts could result in a 35% increase in installed capacity by 2050 relative to the reference case. Participation of renewables, particularly solar, in the fleet increased, driven mostly by the expected increase in summertime peak demand. Such capacity requirements would increase investment costs by approximately 31 billion (USD 2015) over the next 30 years, compared to the reference case. These changes in investment decisions align with carbon emission mitigation strategies, highlighting how adaptation and mitigation strategies can converge.