Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curve fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

SU-E-T-223: Computed Radiography Dose Measurements of External Radiotherapy Beams

Purpose: To obtain quantitative, two-dimensional dose measurements of external radiotherapy beams with a computed radiography (CR) system and to derive volume correction factors for ionization chambers in small fields. Methods: A commercial Kodak ACR2000i CR system with Kodak Flexible Phosphor Screen HR storage foils was used. Suitable measurement conditions and procedures were established. Several corrections were derived, including image fading, length-scale corrections and long-term stability corrections. Dose calibration curves were obtained for cobalt, 4 MV, 8 MV and 25 MV photons, and for 10 MeV, 15 MeV and 18 MeV electrons in a water phantom. Inherent measurement inhomogeneities were studied as well as directional dependence of the response. Finally, 2D scans with ionization chambers were directly compared to CR measurements, and volume correction factors were derived. Results: Dose calibration curves (0.01 Gy to 7 Gy) were obtained for multiple photon and electron beam qualities. For each beam quality, the calibration curves can be described by a single fit equation over the whole dose range. The energy dependence of the dose response was determined. The length scale on the images was adjusted scan-by-scan, typically by 2 percent horizontally and by 3 percent vertically. The remaining inhomogeneities after the system’s standard calibration procedure were corrected for. After correction, the homogeneity is on the order of a few percent. The storage foils can be rotated by up to 30 degrees without a significant effect on the measured signal. First results on the determination of volume correction factors were obtained. Conclusion: With CR, quantitative, two-dimensional dose measurements with a high spatial resolution (sub-mm) can be obtained over a large dose range. In order to make use of these advantages, several calibrations, corrections and supporting measurements are needed. This work was funded by the European Metrology Research Programme (EMRP) project HLT09 MetrExtRT Metrology for Radiotherapy using Complex Radiation Fields.

60 APPLIED LIFE SCIENCES↗

SU-F-T-64: An Alternative Approach to Determining the Reference Air-Kerma Rate from Extrapolation Chamber Measurements

Purpose: Since 2008 the Physikalisch-Technische Bundesanstalt (PTB) has been offering the calibration of {sup 125}I-brachytherapy sources in terms of the reference air-kerma rate (RAKR). The primary standard is a large air-filled parallel-plate extrapolation chamber. The measurement principle is based on the fact that the air-kerma rate is proportional to the increment of ionization per increment of chamber volume at chamber depths greater than the range of secondary electrons originating from the electrode x{sub 0}. Methods: Two methods for deriving the RAKR from the measured ionization charges are: (1) to determine the RAKR from the slope of the linear fit to the so-called ’extrapolation curve’, the measured ionization charges Q vs. plate separations x or (2) to differentiate Q(x) and to derive the RAKR by a linear extrapolation towards zero plate separation. For both methods, correcting the measured data for all known influencing effects before the evaluation method is applied is a precondition. However, the discrepancy of their results is larger than the uncertainty given for the determination of the RAKR with both methods. Results: A new approach to derive the RAKR from the measurements is investigated as an alternative. The method was developed from the ground up, based on radiation transport theory. A conversion factor C(x{sub 1}, x{sub 2}) is applied to the difference of charges measured at the two plate separations x{sub 1} and x{sub 2}. This factor is composed of quotients of three air-kerma values calculated for different plate separations in the chamber: the air kerma Ka(0) for plate separation zero, and the mean air kermas at the plate separations x{sub 1} and x{sub 2}, respectively. The RAKR determined with method (1) yields 4.877 µGy/h, and with method (2) 4.596 µGy/h. The application of the alternative approach results in 4.810 µGy/h. Conclusion: The alternative method shall be established in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sci-Thur PM - Colourful Interactions: Highlights 06: Patient-specific calibration of cone-beam computed tomographic (CBCT) image sets for on-line dose tracking and plan assessment

Purpose: To develop a radiotherapy dose tracking and plan evaluation technique using cone-beam computed tomography (CBCT) images. Methods: We developed a patient-specific method of calibrating CBCT image sets for dose calculation. The planning CT was first registered with the CBCT using deformable image registration (DIR). A scatter plot was generated between the CT numbers of the planning CT and CBCT for each slice. The CBCT calibration curve was obtained by least-square fitting of the data, and applied to each CBCT slice. The calibrated CBCT was then merged with original planning CT to extend the small field of view of CBCT. Finally, the treatment plan was copied to the merged CT for dose tracking and plan evaluation. The proposed patient-specific calibration method was also compared to two methods proposed in literature. To evaluate the accuracy of each technique, 15 head-and-neck patients requiring plan adaptation were arbitrarily selected from our institution. The original plan was calculated on each method’s data set, including a second planning CT acquired within 48 hours of the CBCT (serving as gold standard). Clinically relevant dose metrics and 3D gamma analysis of dose distributions were compared between the different techniques. Results: Compared to the gold standard of using planning CTs, the patient-specific CBCT calibration method was shown to provide promising results with gamma pass rates above 95% and average dose metric agreement within 2.5%. Conclusions: The patient-specific CBCT calibration method could potentially be used for on-line dose tracking and plan evaluation, without requiring a re-planning CT session.

60 APPLIED LIFE SCIENCES↗

Leaf gas exchange and fitted parameters, two sites in Panama, 2022

Photosynthetic CO2 response curves (ACi curves), light response curves (AQ curves), dark adapted dark respiration, conductance curves, and survey measurements for leaves measured in the Parque Natural Metropolitano (PNM) and Gamboa, Panama, from January to April 2022 are presented. Measurements were made on leaves from 46 different tree, shrub and liana species, from sunlit canopy and understory locations. Leaf area index from 8 vertical profiles at PNM are also included. The aim of this measurement campaign was three-fold: (i) to improve our understanding of the vertical variation in leaf-level water use efficiency; (ii) to develop an understanding of the sensitivity of stomata to changes in environmental conditions, especially light, humidity, and temperature; (iii) to improve models which can predict leaf traits from leaf contact spectral measurements. All the gas exchange data and metadata are presented in .csv files and complete instrument output are included in .zip folders. Data and metadata meet the ESS-DIVE leaf-level gas exchange reporting format requirements. The protocol details are provided as pdf documents. In addition to gas exchange data reported here these samples were also used for measurement of leaf optical properties, carbon and nitrogen content, and leaf mass per unit leaf area (LMA). These data can be cross linked using the unique sample ID and are provided in separate data packages.

54 ENVIRONMENTAL SCIENCES↗

Multiobjective Optimization of Regional and Teleseismic Data to Constrain the Source of the 12 September 2016 Mw 5.4 Earthquake in South Korea

In this paper, we propose a new approach for source inversion with automatic criteria for the station selection process and using a multiobjective optimization scheme combining teleseismic body-wave and regional surface-wave observations. To illustrate the approach, we determine the source parameters of the 12 September 2016 M w 5.4 South Korea earthquake, as well as its foreshock (same day) and its main aftershock on 19 September 2016. Available teleseismic (short period and broadband) and regional (broadband) seismograms from the Incorporated Research Institutions for Seismology International–Federation of Digital Seismograph Networks (IRIS-FDSN) webservice are selected (see Data and Resources). First, all teleseismic data with signal-to-noise ratio (SNR) above 2 in the 0.3–1.5 Hz frequency band are selected and a cepstrum function is blindly applied to help detect reflected wave arrivals inside a P coda. This method allows the identification of records with weak P-coda and clear depth phase (pP, sP) arrivals and can be used to select an optimal set of teleseismic seismograms to be used for the inversion. Second, regional seismograms are selected according to the fit between their observed and theoretical dispersion curves extracted from local 1D velocity model. Depending on the epicentral distance, two frequency bands are proposed for regional data: 15–50 s for epicentral distances smaller than 2° and 30–80 s otherwise. Finally, we explore the space parameters from exhaustive grid searches for the two objective functions Tf and Rf for teleseismic and regional data, respectively. We show that the seismic moment parameters can be exclusively derived from Rf and can be fixed for Tf. However, the depth parameter is not sensitive to Rf and can be simultaneously inverted from both. The selection of the optimal solution satisfying both cost functions uses the optimum Pareto front that allows a decrease in epistemic uncertainty. Lastly, we discuss the advantage of this approach for improving the characterization of moderate earthquake sources in areas with limited regional instrumentation.

58 GEOSCIENCES↗

Yttrium solid phase equation of state with uncertainty quantification

We discuss the development of an equation of state (EOS) for solid yttrium up to roughly 80 GPa. The EOS makes use of different experimental datasets, including measurements of the isobaric density, isobaric specific heat, room temperature isotherm, and principal shock Hugoniot. The fitting procedure is carried out using Markov Chain Monte Carlo (MCMC), where we fit model parameters for both the cold curve and ion thermal models simultaneously. The results show close agreement with experimental data and provide meaningful uncertainty estimates on the model parameters. This work serves as a first step towards a multiphase EOS for yttrium, which will include higher pressure solid phases (> 80 GPa), as well as modeling of the liquid phase.

36 MATERIALS SCIENCE↗

Optimization and Multimachine Learning Algorithms to Predict Nanometal Surface Area Transfer Parameters for Gold and Silver Nanoparticles

Interactions between gold metallic nanoparticles and molecular dyes have been well described by the nanometal surface energy transfer (NSET) mechanism. However, the expansion and testing of this model for nanoparticles of different metal composition is needed to develop a greater variety of nanosensors for medical and commercial applications. In this study, the NSET formula was slightly modified in the size-dependent dampening constant and skin depth terms to allow for modeling of different metals as well as testing the quenching effects created by variously sized gold, silver, copper, and platinum nanoparticles. Overall, the metal nanoparticles followed more closely the NSET prediction than for Förster resonance energy transfer, though scattering effects began to occur at 20 nm in the nanoparticle diameter. To further improve the NSET theoretical equation, an attempt was made to set a best-fit line of the NSET theoretical equation curve onto the Au and Ag data points. An exhaustive grid search optimizer was applied in the ranges for two variables, 0.1≤C≤2.0 and 0≤α≤4, representing the metal dampening constant and the orientation of donor to the metal surface, respectively. Three different grid searches, starting from coarse (entire range) to finer (narrower range), resulted in more than one million total calculations with values C=2.0 and α=0.0736. The results improved the calculation, but further analysis needed to be conducted in order to find any additional missing physics. With that motivation, two artificial intelligence/machine learning (AI/ML) algorithms, multilayer perception and least absolute shrinkage and selection operator regression, gave a correlation coefficient, R2, greater than 0.97, indicating that the small dataset was not overfitting and was method-independent. This analysis indicates that an investigation is warranted to focus on deeper physics informed machine learning for the NSET equations.

Demers, Steven M. E. (ORCID:0000000192213246)↗

OPTICAL OBSERVATIONS OF THE TYPE IA SUPERNOVA SN 2011fe IN M101 FOR NEARLY 500 DAYS

We present well-sampled optical observations of the bright Type Ia supernova (SN Ia) SN 2011fe in M101. Our data, starting from ∼16 days before maximum light and extending to ∼463 days after maximum, provide an unprecedented time series of spectra and photometry for a normal SN Ia. Fitting the early-time rising light curve, we find that the luminosity evolution of SN 2011fe follows a t{sup n} law, with the index n being close to 2.0 in the VRI bands but slightly larger in the U and B bands. Combining the published ultraviolet (UV) and near-infrared (NIR) photometry, we derive the contribution of UV/NIR emission relative to the optical. SN 2011fe is found to have stronger UV emission and reaches its UV peak a few days earlier than other SNe Ia with similar Δm{sub 15}(B), suggestive of less trapping of high-energy photons in the ejecta. Moreover, the U-band light curve shows a notably faster decline at late phases (t ≈ 100–300 days), which also suggests that the ejecta may be relatively transparent to UV photons. These results favor the notion that SN 2011fe might have a progenitor system with relatively lower metallicity. On the other hand, the early-phase spectra exhibit prominent high-velocity features (HVFs) of O i λ7773 and the Ca ii NIR triplet, but only barely detectable in Si ii 6355. This difference can be caused by either an ionization/temperature effect or an abundance enhancement scenario for the formation of HVFs; it suggests that the photospheric temperature of SN 2011fe is intrinsically low, perhaps owing to incomplete burning during the explosion of the white dwarf.

79 ASTRONOMY AND ASTROPHYSICS↗

STELLAR MAGNETIC CYCLES IN THE SOLAR-LIKE STARS KEPLER-17 AND KEPLER-63

The stellar magnetic field plays a crucial role in the star internal mechanisms, as in the interactions with its environment. The study of starspots provides information about the stellar magnetic field and can characterize the cycle. Moreover, the analysis of solar-type stars is also useful to shed light onto the origin of the solar magnetic field. The objective of this work is to characterize the magnetic activity of stars. Here, we studied two solar-type stars, Kepler-17 and Kepler-63, using two methods to estimate the magnetic cycle length. The first one characterizes the spots (radius, intensity, and location) by fitting the small variations in the light curve of a star caused by the occultation of a spot during a planetary transit. This approach yields the number of spots present in the stellar surface and the flux deficit subtracted from the star by their presence during each transit. The second method estimates the activity from the excess in the residuals of the transit light curves. This excess is obtained by subtracting a spotless model transit from the light curve and then integrating all the residuals during the transit. The presence of long-term periodicity is estimated in both time series. With the first method, we obtained P {sub cycle} = 1.12 ± 0.16 year (Kepler-17) and P {sub cycle} = 1.27 ± 0.16 year (Kepler-63), and for the second approach the values are 1.35 ± 0.27 year and 1.27 ± 0.12 year, respectively. The results of both methods agree with each other and confirm their robustness.

79 ASTRONOMY AND ASTROPHYSICS↗

An analytical study of reduced-gravity flow dynamics

Addition of surface tension forces to a marker-and-cell code and the performance of four incompressible fluid simulations in reduced gravity, were studied. This marker-and-cell code has a variable grid capability with arbitrary curved boundaries and time dependent acceleration fields. The surface tension logic includes a spline fit of surface marker particles as well as contact angle logic for straight and curved wall boundaries. Three types of flow motion were simulated with the improved code: impulsive settling in a model Centaur LH2 tank, continuous settling in a model and full scale Centaur LO2 tank and mixing in a Centaur LH2 tank. The impulsive settling case confirmed a drop tower analysis which indicated more orderly fluid collection flow patterns with this method providing a potential savings in settling propellants. In the LO2 tank, fluid collection and flow simulation into the thrust barrel were achieved. The mixing simulation produced good results indicating both the development of the flow field and fluid interface behavior.

Bradshaw, R. D.↗

Extinction-sedimentation inversion technique for measuring size distribution of artificial fogs

In measuring the size distribution of artificial fog particles, it is important that the natural state of the particles not be disturbed by the measuring device, such as occurs when samples are drawn through tubes. This paper describes a method for carrying out such a measurement by allowing the fog particles to settle in quiet air inside an enclosure through which traverses a parallel beam of light for measuring the optical depth as a function of time. An analytic function fit to the optical depth time decay curve can be directly inverted to yield the size distribution. Results of one such experiment performed on artificial fogs are shown as an example. The forwardscattering corrections to the measured extinction coefficient are also discussed with the aim of optimizing the experimental design so that the error due to forwardscattering is minimized.

Deepak, A.↗

Brightness, density, and color profiles of three globular clusters - NGC 6440, 6541, and 7099

Using short-exposure SEC television camera observations, the radial distribution profiles of surface brightness, B-V colors and star densities are determined in three globular clusters, NGC 6440, 6541 and 7099, from about 2-200 arc sec from the cluster centers. Good agreement is found between the surface-brightness profiles and the star-density distributions; both can be fitted well with a King-type curve, and no significant evidence for a presence of cusp at r greater then 3 arc sec is observed. Also determined for the three clusters were central surface brightnesses, core radii, central mass densities, total cluster masses, relaxation times and central escape velocities. In addition, an upper limit of 5000 solar masses is placed on the mass of a possible central black hole in these clusters.

Williams, T. B.↗

Documentation of program AFTBDY to generate coordinate system for 3D after body using body fitted curvilinear coordinates, part 1

The computer program AFTBDY generates a body fitted curvilinear coordinate system for a wedge curved after body. This wedge curved after body is being used in an experimental program. The coordinate system generated by AFTBDY is used to solve 3D compressible N.S. equations. The coordinate system in the physical plane is a cartesian x,y,z system, whereas, in the transformed plane a rectangular xi, eta, zeta system is used. The coordinate system generated is such that in the transformed plane coordinate spacing in the xi, eta, zeta direction is constant and equal to unity. The physical plane coordinate lines in the different regions are clustered heavily or sparsely depending on the regions where physical quantities to be solved for by the N.S. equations have high or low gradients. The coordinate distribution in the physical plane is such that x stays constant in eta and zeta direction, whereas, z stays constant in xi and eta direction. The desired distribution in x and z is input to the program. Consequently, only the y-coordinate is solved for by the program AFTBDY.

Kumar, D.↗

Classification of the Allan Hills A77307 meteorite

Thermoluminescence (TL) measurements on Allan Hills A77307 (AH), a carbonaceous chondrite found in Antarctica, are compared with those on other chondrite and applied to its classification. Two lithologically different 250-mg samples were ground, freed of magnetic material, and ground again to pass a 100-micron sieve. Aliquots of 4 mg were heated to 500 C, exposed to beta radiation from a Sr-90 source, and heated at a rate of 7.3 C/sec in N2. TL was measured with a photomultiplier tube fitted with thermal and blue filters. Glow curves for AH and for seven other, established CO-type chondrites area presented, all exhibiting two major peaks of TL sensitivity. The peaks for the seven CO-type chondrites are found at 91 + or - 7 C and at 203 + or - 11 C; those for AH at 170 + or - 17 C and at approximately 250 C. This difference is considered significant and not due to random fluctuation or a typical sampling. From this comparison and from consideration of the weathering, preterrestrial-alteration, petrological and compositional evidence on AH, it is concluded that AH is a unique chondrite, possessing both similarities to and differences from the CO class.

Sears, D. W. G.↗

The energy spectra of solar energetic particles

A survey of recent results on the shapes and relative slopes of the spectra of various solar energetic particle populations is presented, with emphasis on the more extensive results currently available for protons, alphas and electrons. From previous work, it is found that proton spectra 0.8 to more than 400 MeV and alpha spectra 1.4 to 80 MeV/nucleon are best characterized, on average, by a functional form involving a Bessel function in momentum/nucleon. However, proton and alpha spectral slopes using this form are not equal, and there is significant variation from event to event. From other studies, electrons 0.02 to 20 MeV are also found to have curved spectra, but seem to be better fit with a double power law in energy. The spectral properties in both cases correlate with other measures of solar particle acceleration; e.g. gamma-ray line production, hard X-ray burst spectra and microwave fluxes.

Mcguire, R. E.↗

Interstellar absorption lines in the spectrum of sigma Sco using Copernicus observations

Since the launch of Copernicus in 1972, studies have been made of the depletion of gas-phase elements onto dust grains. A few stars have been studied in detail, resulting in a standard depletion pattern which has since been used for comparison. Recent developments, however, have suggested that this standard pattern may need to be re-examined. Some weak, semi-forbidden lines were detected recently which may be able to resolve some of the ambiguities. Studies of single elements have shown that depletion of carbon and oxgyen are much smaller than previously determined. The high resolution ultraviolet spectral scans of sigma Sco were originally made in 1973, but have only recently been analyzed. All these stars are bright and moderately reddened. All four stars will be analyzed in detail, but sigma Sco is the first one completed. The data has broad coverage of ions, making these stars excellent candidates for determination of accurate depletions. A profile-fitting analysis was used rather than curves-of-growth in order to determine separate abundances and depletions in components separated by several km/sec.

Allen, M. M.↗

Photometric properties of lunar terrains derived from Hapke's equation

Hapke's bidirectional reflectance equations provide the most rigorous available description of photometric behavior in terms of physically meaningful parameters. The primary objective of this study was to derive Hapke parameters for the lunar surface from both disk-integrated and disk-resolved photometric data. Hapke's equation was fit to the disk-integrated phase curves and disk-resolved data for dark, average, and bright terrain classes using an iterative, nonlinear least squares algorithm described by Helfenstein. Parameters were initially determined from the disk-integrated data, and the result was applied as a first guess to the iterative solution of parameters for individual terrain classes. Plots are presented of the disk-resolved data normalized to corresponding brightnesses predicted from the disk-integrated solution under the same illumination and viewing geometries. Systematic trends in disk-resolved parameters can be identified. Values for single scattering albedo (w) of the dominantly anorthositic average and bright terrains are significantly larger than the value for the basaltic dark terrains (mare). Values for surge brightness parameters, particle phase function, and average topographic slope angle are also discussed.

Helfenstein, Paul↗