Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Countermeasures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Induction of a Radio-Adaptive Response by Low-dose Gamma Irradiation in Mouse Cardiomyocytes

One of the most significant occupational hazards to an astronaut is the frequent exposure to radiation. Commonly associated with increased risk for cancer related morbidity and mortality, radiation is also known to increase the risk for cardiovascular related disorders including: pericarditis, hypertension, and heart failure. It is believed that these radiation-induced disorders are a result of abnormal tissue remodeling. It is unknown whether radiation exposure promotes remodeling through fibrotic changes alone or in combination with programmed cell death. Furthermore, it is not known whether it is possible to mitigate the hazardous effects of radiation exposure. As such, we assessed the expression and mechanisms of radiation-induced tissue remodeling and potential radio-adaptive responses of p53-mediated apoptosis and fibrosis pathways along with markers for oxidative stress and inflammation in mice myocardium. 7 week old, male, C57Bl/6 mice were exposed to 6Gy (H) or 5cGy followed 24hr later with 6Gy (LH) 137Cs gamma radiation. Mice were sacrificed and their hearts extirpated 4, 24, or 72hr after final irradiation. Real Time - Polymerase Chain Reaction was used to evaluate target genes. Apoptotic genes Bad and Bax, pro-cell survival genes Bcl2 and Bcl2l2, fibrosis gene Vegfa, and oxidative stress genes Sod2 and GPx4 showed a reduced fold regulation change (Bad,-6.18; Bax,-6.94; Bcl2,-5.09; Bcl2l2,-4.03; Vegfa, -11.84; Sod2,-5.97; GPx4*,-28.72; * = Bonferroni adjusted p-value < or = 0.003) 4hr after H, but not after 4hr LH compared to control. Other p53-mediated apoptosis genes Casp3, Casp9, Trp53, and Myc exhibited down-regulation but did not achieve a notable level of significance 4hr after H. 24hr after H, genetic down-regulation was no longer present compared to 24hr control. These data suggest a general reduction in genetic expression 4hrs after a high dose of gamma radiation. However, pre-exposure to 5cGy gamma radiation appears to facilitate a radio-adaptive response that mitigates the reduction in genetic expression associated with single high-dose gamma radiation exposure. This radio-adaptive response may serve as a potential countermeasure to radiation-induced myocardial remodeling and preserve the cardiovascular health of astronauts; thus, reducing the risks of human space exploration.

Westby, Christian M.↗

Orthostatic Hypotension After Long-Duration Space Flight: NASA's Experiences from the International Space Station

Our laboratory previously reported that the incidence of orthostatic hypotension (OH) was greater after long- than short-duration spaceflight in astronauts who participated in Mir Space Station and Space Shuttle missions. To confirm and extend these findings, we retrospectively examined tilt test data from International Space Station (ISS) and Shuttle astronauts. We anticipated that the proportion of ISS astronauts experiencing OH would be high on landing day and the number of days to recover greater after long- than short-duration missions. Methods: Twenty ISS and 66 Shuttle astronauts participated in 10-min 80? head-up tilt tests 10 d before launch (L-10), on landing day (R+0) or 1 d after landing (R+1). Data from 5 ISS astronauts tested on R+0 or R+1 who used non-standard countermeasures were excluded. Many astronauts repeated the test 3 d (R+3) after landing. Fisher?s Exact Test was used to compare the ability of ISS and Shuttle astronauts to complete the tilt test on R+0. Cox regression was used to identify cardiovascular parameters that were associated with test completion across all tests, and mixed model analysis was used to compare the change and recovery rates between ISS and Shuttle astronauts. In these analyses, ISS data from R+0 and R+1 were pooled to provide sufficient statistical power. Results: The proportion of astronauts who completed the tilt test on R+0 without OH was less in ISS than in Shuttle astronauts (p=0.03). On R+0, only 2 of 6 ISS astronauts completed the test compared to 53 of 66 (80%) Shuttle astronauts. However, 8 of 9 ISS astronauts completed the test on R+1. On R+3, 13 of 15 (87%) of the ISS and 19 of 19 (100%) of the Shuttle astronauts completed the 10-min test. An index comprised of stroke volume and diastolic blood pressure provided a very good prediction of overall tilt survival. This index was altered by spaceflight similarly for both groups soon after landing (pooled R+0 and R+ 1), but ISS astronauts did not recover at the same rate as Shuttle astronauts (p=0.007). Conclusions: The proportion of ISS astronauts who could not complete the tilt test on R+0 due to OH (4 of 6) is similar to that reported in astronauts who flew on Mir (5 of 6). Further, cardiovascular parameters most closely associated with OH recover more slowly after long- compared to short-duration spaceflight.

Lee, Stuart M. C.↗

Enhancement of Otolith Specific Ocular Responses Using Vestibular Stochastic Resonance

Introduction: Astronauts experience disturbances in sensorimotor function after spaceflight during the initial introduction to a gravitational environment, especially after long-duration missions. Our goal is to develop a countermeasure based on vestibular stochastic resonance (SR) that could improve central interpretation of vestibular input and mitigate these risks. SR is a mechanism by which noise can assist and enhance the response of neural systems to relevant, imperceptible sensory signals. We have previously shown that imperceptible electrical stimulation of the vestibular system enhances balance performance while standing on an unstable surface. Methods: Eye movement data were collected from 10 subjects during variable radius centrifugation (VRC). Subjects performed 11 trials of VRC that provided equivalent tilt stimuli from otolith and other graviceptor input without the normal concordant canal cues. Bipolar stochastic electrical stimulation, in the range of 0-1500 microamperes, was applied to the vestibular system using a constant current stimulator through electrodes placed over the mastoid process behind the ears. In the VRC paradigm, subjects were accelerated to 216 deg./s. After the subjects no longer sensed rotation, the chair oscillated along a track at 0.1 Hz to provide tilt stimuli of 10 deg. Eye movements were recorded for 6 cycles while subjects fixated on a target in darkness. Ocular counter roll (OCR) movement was calculated from the eye movement data during periods of chair oscillations. Results: Preliminary analysis of the data revealed that 9 of 10 subjects showed an average increase of 28% in the magnitude of OCR responses to the equivalent tilt stimuli while experiencing vestibular SR. The signal amplitude at which performance was maximized was in the range of 100-900 microamperes. Discussion: These results indicate that stochastic electrical stimulation of the vestibular system can improve otolith specific responses. This will have a significant impact on development of vestibular SR delivery systems to aid recovery of function in astronauts after long-duration spaceflight or in people with balance disorders.

Fiedler, Matthew↗

DCS: A Case Study of Identification of Knowledge and Disposition Gaps Using Principles of Continuous Risk Management

The Human Research Program (HRP) is formulated around the program architecture of Evidence-Risk-Gap-Task-Deliverable. Review of accumulated evidence forms the basis for identification of high priority risks to human health and performance in space exploration. Gaps in knowledge or disposition are identified for each risk, and a portfolio of research tasks is developed to fill them. Deliverables from the tasks inform the evidence base with the ultimate goal of defining the level of risk and reducing it to an acceptable level. A comprehensive framework for gap identification, focus, and metrics has been developed based on principles of continuous risk management and clinical care. Research towards knowledge gaps improves understanding of the likelihood, consequence or timeframe of the risk. Disposition gaps include development of standards or requirements for risk acceptance, development of countermeasures or technology to mitigate the risk, and yearly technology assessment related to watching developments related to the risk. Standard concepts from clinical care: prevention, diagnosis, treatment, monitoring, rehabilitation, and surveillance, can be used to focus gaps dealing with risk mitigation. The research plan for the new HRP Risk of Decompression Sickness (DCS) used the framework to identify one disposition gap related to establishment of a DCS standard for acceptable risk, two knowledge gaps related to DCS phenomenon and mission attributes, and three mitigation gaps focused on prediction, prevention, and new technology watch. These gaps were organized in this manner primarily based on target for closure and ease of organizing interim metrics so that gap status could be quantified. Additional considerations for the knowledge gaps were that one was highly design reference mission specific and the other gap was focused on DCS phenomenon.

Norcross, Jason↗

Expression of Enzymes that Metabolize Medications

INTRODUCTION: Increased exposure to radiation is one physiological stressor associated with spaceflight and it is feasible to conduct ground experiments using known radiation exposures. The health of the liver, especially the activity rate of its metabolic enzymes, determines the concentration of circulating drugs as well as the duration of their efficacy. While radiation is known to alter normal physiological function, how radiation affects liver metabolism of administered medications is unclear. Crew health could be affected if the actions of medications used in spaceflight deviated from expectations formed during terrestrial medication use. This study is an effort to identify liver metabolic enzymes whose expression is altered by spaceflight or by radiation exposures that mimic features of the spaceflight environment. METHODS: Using procedures approved by the Animal Care and Use Committee, mice were exposed to either 137Cs (controls, 50 mGy, 6Gy, or 50 mGy + 6Gy separated by 24 hours) or 13 days of spaceflight on STS 135. Animals were anesthetized and sacrificed at several time points (4 hours, 24 hours or 7 days) after their last radiation exposure, or within 6 hours of return to Earth for the STS 135 animals. Livers were removed immediately and flash-frozen in liquid nitrogen. Tissue was homogenized, RNA extracted, purified and quality-tested. Complementary DNA was prepared from high-quality RNA samples, and used in RT-qPCR experiments to determine relative expression of a wide variety of genes involved in general metabolism and drug metabolism. RESULTS: Results of the ground radiation exposure experiments indicated ~65 genes of the 190 tested were significantly affected by at least one of the radiation doses. Many of the affected genes are involved in the metabolism of drugs with hydrophobic or steroid-like structures, maintenance of redox homeostasis and repair of DNA damage. Most affected genes returned to near control expression levels by 7 days post-treatment. Not all recovered completely by the final time point tested: with 6 Gy exposure, metallothionein expression was 132-fold more than control at the 4 hr time point, and fell at each later time point (11-fold at 24 hrs, and 8-fold at 7 days). In contrast, there were other genes whose expression was altered and remained relatively constant through the 7 day period we tested. One examples is Cyp17a1, which showed a 4-fold elevation at 4 hrs after exposure and remained constant for 7 days after the last treatment. Spaceflight samples evaluated with similar methods and comparisons will be made between the radiation-treated groups and the spaceflight samples. CONCLUSION It seems likely that radiation exposure triggers homeostatic mechanisms, which could include alterations of gene expression. Better understanding of these pathways could aid in optimizing medications doses given to crewmembers who require treatment and eventually, to development of new countermeasures to ameliorate or prevent radiation-induced damage to cells and tissues.

Wotring, V. E.↗

Urinary Acid Excretion Can Predict Changes in Bone Metabolism During Space Flight

Mitigating space flight-induced bone loss is critical for space exploration, and a dietary countermeasure would be ideal. We present here preliminary data from a study where we examined the role of dietary intake patterns as one factor that can influence bone mineral loss in astronauts during space flight. Crewmembers (n=5) were asked to consume a prescribed diet with either a low (0.3-0.6) or high (1.0-1.3) ratio of animal protein to potassium (APro:K) before and during space flight for 4-d periods. Diets were controlled for energy, total protein, calcium, and sodium. 24-h urine samples were collected on the last day of each of the 4-d controlled diet sessions. 24-h urinary acid excretion, which was predicted by dietary potential renal acid load, was correlated with urinary n-telopeptide (NTX, Pearson R = 0.99 and 0.80 for the high and low APro:K sessions, respectively, p<0.001). The amount of protein when expressed as the percentage of total energy (but not as total grams) was also correlated with urinary NTX (R = 0.66, p<0.01). These results, from healthy individuals in a unique environment, will be important to better understand diet and bone interrelationships during space flight as well as on Earth. The study was funded by the NASA Human Research Program.

Zwart, Sara R.↗

Modification of Motion Perception and Manual Control Following Short-Durations Spaceflight

Adaptive changes during space flight in how the brain integrates vestibular cues with other sensory information can lead to impaired movement coordination and spatial disorientation following G-transitions. This ESA-NASA study was designed to examine both the physiological basis and operational implications for disorientation and tilt-translation disturbances following short-duration spaceflights. The goals of this study were to (1) examine the effects of stimulus frequency on adaptive changes in motion perception during passive tilt and translation motion, (2) quantify decrements in manual control of tilt motion, and (3) evaluate vibrotactile feedback as a sensorimotor countermeasure.

Wood, S. J.↗

Biomechanical Analysis of Treadmill Locomotion on the International Space Station

Treadmill locomotion exercise is an important aspect of ISS exercise countermeasures. It is widely believed that an optimized treadmill exercise protocol could offer benefits to cardiovascular and bone health. If training heart rate is high enough, treadmill exercise is expected to lead to improvements in aerobic fitness. If impact or bone loading forces are high enough, treadmill exercise may be expected to contribute to improved bone outcomes. Ground-based research suggests that joint loads increase with increased running speed. However, it is unknown if increases in locomotion speed results in similar increases in joint loads in microgravity. Although data exist regarding the biomechanics of running and walking in microgravity, a majority were collected during parabolic flight or during investigations utilizing a microgravity analog. The Second Generation Treadmill (T2) has been in use on the International Space Station (ISS) and records the ground reaction forces (GRF) produced by crewmembers during exercise. Biomechanical analyses will aid in understanding potential differences in typical gait motion and allow for modeling of the human body to determine joint and muscle forces during exercise. By understanding these mechanisms, more appropriate exercise prescriptions can be developed that address deficiencies. The objective of this evaluation is to collect biomechanical data from crewmembers during treadmill exercise prior to and during flight. The goal is to determine if locomotive biomechanics differ between normal and microgravity environments and to determine how combinations of subject load and speed influence joint loading during in-flight treadmill exercise. Further, the data will be used to characterize any differences in specific bone and muscle loading during locomotion in these two gravitational conditions. This project maps to the HRP Integrated Research Plan risks including Risk of Bone Fracture (Gap B15), Risk of Early Onset Osteoporosis Due to Spaceflight (Gap B15), Risk of Impaired Performance Due to Reduced Muscle Mass, Strength, and Endurance (Gaps M3, M4, M6, Ml, M8, M9) and Risk of reduced Physical Performance Capabilities Due to Reduce Aerobic Capacity (Gaps M7, M8, M9).

De Witt, J. K.↗

Optimizing Muscle Parameters in Musculoskeletal Modeling Using Monte Carlo Simulations

Astronauts assigned to long-duration missions experience bone and muscle atrophy in the lower limbs. The use of musculoskeletal simulation software has become a useful tool for modeling joint and muscle forces during human activity in reduced gravity as access to direct experimentation is limited. Knowledge of muscle and joint loads can better inform the design of exercise protocols and exercise countermeasure equipment. In this study, the LifeModeler(TM) (San Clemente, CA) biomechanics simulation software was used to model a squat exercise. The initial model using default parameters yielded physiologically reasonable hip-joint forces. However, no activation was predicted in some large muscles such as rectus femoris, which have been shown to be active in 1-g performance of the activity. Parametric testing was conducted using Monte Carlo methods and combinatorial reduction to find a muscle parameter set that more closely matched physiologically observed activation patterns during the squat exercise. Peak hip joint force using the default parameters was 2.96 times body weight (BW) and increased to 3.21 BW in an optimized, feature-selected test case. The rectus femoris was predicted to peak at 60.1% activation following muscle recruitment optimization, compared to 19.2% activation with default parameters. These results indicate the critical role that muscle parameters play in joint force estimation and the need for exploration of the solution space to achieve physiologically realistic muscle activation.

Hanson, Andrea↗

Immune System Dysregulation and Latent Herpesvirus Reactivation During Winterover at Concordia Station, Dome C, Antarctica

Immune system dysregulation occurs during spaceflight and consists of altered peripheral leukocyte distribution, reductions in immunocyte function and altered cytokine production profiles. Causes may include stress, confinement, isolation, and disrupted circadian rhythms. All of these factors may be replicated to some degree in terrestrial environments. NASA is currently evaluating the potential for a ground-based analog for immune dysregulation, which would have utility for mechanistic investigations and countermeasures evaluation. For ground-based space physiology research, the choice of terrestrial analog must carefully match the system of interest. Antarctica winter-over, consisting of prolonged durations in an extreme/dangerous environment, station-based habitation, isolation and disrupted circadian rhythms, is potentially a good ground-analog for spaceflight-associated immune dysregulation. Of all Antarctica bases, the French-Italian Concordia Station, may be the most appropriate to replicate spaceflight/exploration conditions. Concordia is an interior base located in harsh environmental conditions, and has been constructed to house small, international crews in a station-environment similar to what should be experienced by deep space astronauts. The ESA-NASA CHOICE study assessed innate and adaptive immunity, viral reactivation and stress factors during Concordia winterover deployment. The study was conducted over two winterover missions in 2009 and 2010. Final study data from NASA participation in these missions will be presented.

Crucian, B. E.↗

Technology Development to Support Human Health and Performance in Exploration Beyond Low Earth Orbit

In the course of defining the level of risks and mitigating the risks for exploration missions beyond low Earth orbit, NASA s Human Research Program (HRP) has identified the need for technology development in several areas. Long duration missions increase the risk of serious medical conditions due to limited options for return to Earth; no resupply; highly limited mass, power, volume; and communication delays. New space flight compatible medical capabilities required include: diagnostic imaging, oxygen concentrator, ventilator, laboratory analysis (saliva, blood, urine), kidney stone diagnosis & treatment, IV solution preparation and delivery. Maintenance of behavioral health in such an isolated, confined and extreme environment requires new sensory stimulation (e.g., virtual reality) technology. Unobtrusive monitoring of behavioral health and treatment methods are also required. Prolonged exposure to weightlessness deconditions bone, muscle, and the cardiovascular system. Novel exercise equipment or artificial gravity are necessary to prevent deconditioning. Monitoring of the degree of deconditioning is required to ensure that countermeasures are effective. New technologies are required in all the habitable volumes (e.g., suit, capsule, habitat, exploration vehicle, lander) to provide an adequate food system, and to meet human environmental standards for air, water, and surface contamination. Communication delays require the crew to be more autonomous. Onboard decision support tools that assist crew with real-time detection and diagnosis of vehicle and habitat operational anomalies will enable greater autonomy. Multi-use shield systems are required to provide shielding from solar particle events. The HRP is pursuing the development of these technologies in laboratories, flight analog environments and the ISS so that the human health and performance risks will be acceptable with the available resources.

Kundrot, C.E.↗

Comparison of Two Methods for Noninvasive Determination of Stroke Volume During Orthostatic Challenge

Background: The real time, beat-by-beat, non-invasive determination of stroke volume (SV) is an important parameter in many aerospace related physiologic protocols. In this study, we compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. Methods: Using a prospective, randomized blinded protocol, ten males and nine females completed 12-mm tilt table protocols. The relative change (%(Delta)) in beat-to-beat SV was estimated non-invasively from changes in pulse waveforms measured by application of infrared finger photoplethysmography (IFP) with a Portapres(Registered TradeMark) blood pressure monitoring device and by thoracic impedance cardiography (TIC). The %(Delta) SV values were calculated from continuous SV measurements in the supine posture and over the first 10 s (T1), second 10 s (T2), and 3.5 minutes (T3) of 80deg head-up tilt (HUT). Results: The average %(Delta) SV measured by IFP at T1 (-11.7 +/- 3.7 %) was statistically less (P <0.02) than the average %(Delta) SV measured by TIC at T1 (-21.7 +/- 3.1 %), while the average %(Delta) SV measured by 1FF at T2 (-16.2 +/- 3.9 %) and T3 (-19.1 +/- 3.8 %) were not statistically distinguishable (P > or = 0.322) than the average %(Delta) SV measured by TIC at T2 (-21.8 +/- 2.5 %), and T3 (-22.6 +/- 2.9 %). Correlation coefficients (r(sup 2)) between IFP and TIC were 0.117 (T1), 0.387 (T2), and 0.7 18 (T3). Conclusion: IFP provides beat-to-beat (real time) assessment of %(Delta) SV after 20 sec of transition to an orthostatic challenge that is comparable to the commonly accepted TIC. Our data support the notion that IFP technology which has flown during space missions can be used to accurately assess physiological status and countermeasure effectiveness for orth static problems that may arise in astronauts after space flight. While the peripherally measured IFP response is slightly delayed, the ease of implementing this monitor in the field is advantageous.

Doerr, Donald F.↗

The Effects of Solar Maximum on the Earth's Satellite Population and Space Situational Awareness

The rapidly approaching maximum of Solar Cycle 24 will have wide-ranging effects not only on the number and distribution of resident space objects, but also on vital aspects of space situational awareness, including conjunction assessment processes. The best known consequence of high solar activity is an increase in the density of the thermosphere, which, in turn, increases drag on the vast majority of objects in low Earth orbit. The most prominent evidence of this is seen in a dramatic increase in space object reentries. Due to the massive amounts of new debris created by the fragmentations of Fengyun-1C, Cosmos 2251 and Iridium 33 during the recent period of Solar Minimum, this effect might reach epic levels. However, space surveillance systems are also affected, both directly and indirectly, historically leading to an increase in the number of lost satellites and in the routine accuracy of the calculation of their orbits. Thus, at a time when more objects are drifting through regions containing exceptionally high-value assets, such as the International Space Station and remote sensing satellites, their position uncertainties increase. In other words, as the possibility of damaging and catastrophic collisions increases, our ability to protect space systems is degraded. Potential countermeasures include adjustments to space surveillance techniques and the resetting of collision avoidance maneuver thresholds.

Johnson, Nicholas L.↗

Plasma Cytokine Levels During Long-Duration Spaceflight

Determine the in-flight status of immunity, physiological stress, viral immunity/reactivation. Specific measurements include leukocyte distribution, T cell function, cytokine production profiles (mRNA, intracellular, secreted, plasma), virus-specific T cell number/function, latent herpesvirus reactivation, stress hormone levels. Determine the clinical risk related to immune dysregulation for exploration class spaceflight, as well as an appropriate monitoring strategy for spaceflight-associated immune dysfunction, that could be used for the evaluation of countermeasures. Specific Study Objectives: Determine the nutritional status of astronauts before, during, and after spaceflight ensure adequate intake of energy, protein, and vitamins during missions. The Clinical Nutritional Status Assessment measures dietary intake, body composition, protein, bone, iron, mineral, vitamin, and antioxidant status (60 total analytes). Currently, it is a medical requirement for U.S. crewmembers on-board the ISS. The results of data analysis are used both to understand the connections between nutrition and human health during space flight, and to develop effective dietary strategies to reduce adverse health impacts (including bone loss, loss of important vitamins and minerals, and increased genetic damage from radiation).

Crucian, Brian E.↗

Subjective Sleep Experience During Shuttle Missions

It is now known that for many astronauts, sleep is reduced in spaceflight. Given that sleep is intimately tied to performance, safety, health, and well being, it is important to characterize factors that hinder sleep in space, so countermeasures can be implemented. Lessons learned from current spaceflight can be used to inform the development of space habitats and mitigation strategies for future exploration missions. The purpose of this study was to implement a survey and one-on-one interviews to capture Shuttle flyers' subjective assessment of the factors that interfered with a "good nights sleep" during their missions. Strategies that crewmembers reported using to improve their sleep quality during spaceflight were also discussed. Highlights from the interview data are presented here.

Whitmire, Alexandra↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

Desert Research and Technology Studies Exposure of Lotus Coated Electrodynamic Shield Samples

The passive Lotus dust mitigation coating currently being developed at NASA's Goddard Space Flight Center (GSFC), was selected by the Habitation Demonstration Unit Deep Space Habitat (HDU-DSH) for participation in the 2011 Desert Research and Technology Studies (D-RaTS). Based on the unique surface architecture of the Lotus leaf, the nano-engineered Lotus coating seeks to replicate these structures on space flight and habitation surfaces. By decreasing both the surface energy and area for particle attachment, the Lotus coating greatly diminishes dust accumulation on surfaces. This is a problem that can be encountered on lunar, Martian, and asteroid missions. Two different application methods of this coating were tested in summer 2011 at the D-RaTS site: the wet chemistry applied version and combustion chemical vapor deposition (CCVD) applied version. These Lotus coatings, along with two common thermal control coatings, were combined with the active dust mitigation electrodynamic shield (EDS) technology developed at Kennedy Space Center (KSC). The EDS technology uses an electrified grid to remove dust particles from the surface of a Kapton (Trademark) substrate. The Lotus coating and thermal control coatings were applied to these Kapton (Trademark) substrates for testing. The combination of these two innovations was theorized to be an applicable countermeasure for addressing dust accumulation during long-duration human space exploration. This theory was tested and characterized prior to, during, and after D-RaTS exposure.

Margiotta, Danielle V.↗