Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

High Purity and Reduced Defects Hard Carbon Synthesis for Sodium-Ion Batteries

Hard carbon (HC) is the state-of-the-art anode material for sodium-ion batteries; however, the high-temperature carbonization of precursors (>1100 °C) often introduces inorganic impurities, an issue that remains largely underexplored. Here, we report a simple synthesis strategy for producing high purity HC by carbonizing a cellulose-derived precursor at 1400 °C under a slightly reducing Ar–H2 atmosphere on a graphite substrate, thereby eliminating the aluminum contamination observed during conventional carbonization on an alumina substrate under Ar. In addition, the modified synthetic condition reduces surface defects and the concentration of oxygen-containing functional groups, thereby altering the interphase formation on the HC surface. At a current density of 20 mA g−1, the impurity-rich HC exhibited an initial coulombic efficiency (ICE) of 74.1% and a reversible capacity of 248.8 mAh g−1. In sharp contrast, the high purity HC delivered a significantly improved ICE of 90.1% and a reversible capacity of 345.1 mAh g−1. These results underscore the critical importance of impurity and defect control during HC synthesis and highlight the clear electrochemical advantages of high purity HC with reduced defects for sodium-ion battery anodes.

Harshita, Lohanni↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

LONG-TERM STEWARDSHIP AT DOE HANFORD SITE - 12575

The U.S. Department of Energy's (DOE) Hanford Site is located in southeast Washington and consists of 1,518 square kilometers (586 square miles) of land. Established in 1943 as part of the Manhattan Project, Hanford workers produced plutonium for our nation's nuclear defense program until the mid 1980's. Since then, the site has been in cleanup mode that is being accomplished in phases. As we achieve remedial objectives and complete active cleanup, DOE will manage Hanford land under the Long-Term Stewardship (LTS) Program until completion of cleanup and the site becomes ready for transfer to the post cleanup landlord - currently planned for DOE's Office of Legacy Management (LM). We define Hanford's LTS Program in the ''Hanford Long-Term Stewardship Program Plan,'' (DOE/RL-201 0-35)[1], which describes the scope including the relationship between the cleanup projects and the LTS Program. DOE designed the LTS Program to manage and provide surveillance and maintenance (S&M) of institutional controls and associated monitoring of closed waste sites to ensure the protection of human health and the environment. DOE's Richland Operations Office (DOE-RL) and Hanford cleanup and operations contractors collaboratively developed this program over several years. The program's scope also includes 15 key activities that are identified in the DOE Program Plan (DOE/RL-2010-35). The LTS Program will transition 14 land segments through 2016. The combined land mass is approximately 570 square kilometers (220 square miles), with over 1,300 active and inactive waste sites and 3,363 wells. Land segments vary from buffer zone property with no known contamination to cocooned reactor buildings, demolished support facilities, and remediated cribs and trenches. DOE-RL will transition land management responsibilities from cleanup contractors to the Mission Support Contract (MSC), who will then administer the LTS Program for DOE-RL. This process requires an environment of cooperation between the contractors and DOE-RL. Information Management (IM) is a key part of the LTS program. The IM Program identifies, locates, stores, protects and makes accessible Hanford LTS records and data to support the transfer of property ultimately to LM. As such, DOE-RL manages the Hanford LTS Program in a manner consistent with LM's goals, policies, and procedures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Video Diagnostic for W7-X Stellarator

The video diagnostics for W7-X--which is under development--is devoted to observe plasma and frrst wall elements during operation, to warn in case of hot spots and dangerous heat load and to give information about the plasma size, position, edge structure, the geometry and location of magnetic islands and distribution of impurities. The video diagnostics will be mounted on the tangential AEQ-ports of the torus that are not straight and have about 2m length and a typical diameter of 0.1m which makes its realization more difficult. The geometry of the 10 tangential views of the AEQ-ports allows giving an almost complete overview of the vessel interior making this diagnostic indispensable for the machine operation. Different concepts of the diagnostics were investigated and finally the following design was selected. As a large heat load is expected on the optical window located at the plasma-facing end of the AEQ-port, the port window is protected by a cooled pinhole. An uncooled shutter located behind the pinhole can be closed to prevent window contamination during vessel conditioning discharges (glow discharge cleaning) and from inter-pulse deposition of soft a-C:H layers. The imaging optics and the detection sensor are located behind the port window in the port tube, which will be under atmospheric pressure. To detect the visible radiation distribution a new camera system called Event Detection Intelligent Camera (EDICAM) is under development. The system is divided into three major separated components. The Sensor Module contains only the selected CMOS sensor, the analog digital converters and the minimal electronics necessary for the communication with the subsequent camera system module called Image Processing and Control Unit (IPCU). Its simple structure makes the Sensor Module suitable to operate despite being exposed to ionizing (neutron, {gamma}-) radiation. The IPCU, which can be located far from the Sensor Module and therefore far from the plasma, is designed to perform real time evaluation of the images detecting predefined events, managing the sensor read-out and the input triggers and producing the output triggers generated by the detected events. The IPCU can also be used to reduce the amount of the stored data. A Standard 10 Gigabit Ethernet fiber optics connection connects the IPCU module to the PC with GigEVision communication protocol.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achieving Accelerated Cleanup of Cesium Contaminated Stream at the Savannah River Site; Collaboration between Stakeholders, Regulators, and the Federal Government - 13182

The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina that contains six primary stream/river systems. The Lower Three Runs Stream (LTR) is one of the primary streams within the site that is located in the southeast portion of the Savannah River Site and is a large black water stream system that originates in the northeast portion of SRS and follows a southerly direction before it enters the Savannah River. During reactor operations, secondary reactor cooling water, storm sewer discharges, and miscellaneous wastewater was discharged and contaminated a 36 kilometer stretch of Lower Three Runs Stream that narrows providing a limited buffer of US DOE property along the stream and flood plain. Based on data collected during 2009 and 2010 under Recover Act Funding, the stream was determined to be contaminated with cesium-137 at levels that exceeded acceptable risk based limits. As efficiencies were realized within the SRS Recovery Act Program, funding was made available to design, permit and execute remediation of the LTR. This accelerated Project allowed for the remediation of 36 kilometers of LTR in only nine months from inception to completion, contributing significantly to the Foot Print Reduction of SRS. The scope consisted of excavation and disposal of more than 2064 cubic meters of contaminated soil, and installing 11 kilometers of fence and 2,000 signs at 1000 locations. Confirmatory sampling and analysis, and radiological surveying were performed demonstrating that soil concentrations met the cleanup goals. The project completed with a very good safety record considering the harsh conditions including, excessive rain in the early stages of the project, high summer temperatures, swampy terrain, snakes, wild boar, insects and dense vegetation. The regulatory approval process was compressed by over 75% and required significant efforts from SRS's stakeholders including the regulators, U. S. Environmental Protection Agency (US EPA) and the South Carolina Department of Health and Environmental Control (SCDHEC), and the public including local property owners and the SRS Citizens Advisory Board. Stakeholder buy-in was critical in the up-front planning in order to achieve this challenging cleanup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings

California's building efficiency standards (Title 24) mandate minimum prescribed ventilation rates (VRs) for commercial buildings. Title 24 standards currently include a prescriptive procedure similar to ASHRAE’s prescriptive “ventilation rate procedure”, but does not include an alternative procedure, akin to ASHRAE’s non-prescriptive “indoor air quality procedure” (IAQP). The IAQP determines minimum VRs based on objectively and subjectively evaluated indoor air quality (IAQ). The first primary goal of this study was to determine, in a set of California retail stores, the adequacy of Title 24 VRs and observed current measured VRs in providing the level of IAQ specified through an IAQP process, The second primary goal was to evaluate whether several VRs implemented experimentally in a big box store would achieve adequate IAQ, assessed objectively and subjectively. For the first goal, a list of contaminants of concern (CoCs) and reference exposure levels (RELs) were selected for evaluating IAQ. Ventilation rates and indoor and outdoor CoC concentrations were measured in 13 stores, including one “big box” store. Mass balance models were employed to calculate indoor contaminant source strengths for CoCs in each store. Using these source strengths and typical outdoor air contaminant concentrations, mass balance models were again used to calculate for each store the “IAQP” VR that would maintain indoor CoC concentrations below selected RELs. These IAQP VRs were compared to the observed VRs and to the Title 24- prescribed VRs. For the second goal, a VR intervention study was performed in the big box store to determine how objectively assessed indoor contaminant levels and subjectively assessed IAQ varied with VR. The three intervention study VRs included an approximation of the store’s current VR [0.24 air changes per hour (ACH)], the Title 24-prescribed VR [0.69 ACH], and the calculated IAQPbased VR [1.51 ACH]). Calculations of IAQP-based VRs showed that for the big box store and 11 of the 12 other stores, neither current measured VRs nor the Title 24-prescribed VRs would be sufficient to maintain indoor concentrations of all CoCs below RELs. In the intervention study, with the IAQP-based VR applied in the big box store, all CoCs were controlled below RELs (within margins of error). Also, at all three VRs in this store, the percentage of subjects reporting acceptable air quality exceeded an 80% criterion of acceptability. The IAQP allows consideration of outdoor air ventilation as just one of several possible tools for achieving adequate IAQ. In two of the 13 surveyed buildings, applying the IAQP to allow lower VRs could have saved energy whilst still maintaining acceptable indoor air quality. In the remaining 11 buildings, saving energy through lower VRs would require combination with other strategies, either reducing indoor sources of CoCs such as formaldehyde, or use of gas phase air cleaning technologies. Based on the findings from applying the IAQP calculations to retail stores and the IAQP-based intervention study, recommendations are made regarding the potential introduction of a comparable procedure in Title 24.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Is Entombment an Acceptable Option for Decommissioning? An International Perspective - 13488

Selection of a decommissioning strategy is one of the key steps in the preparation for decommissioning of nuclear facilities and other facilities using radioactive material. Approaches being implemented or considered by Member States include immediate dismantling, deferred dismantling and entombment. Other options or slight modifications of these strategies are also possible. Entombment has been identified in the current International Atomic Energy Agency (IAEA) Safety Standards as one of the three basic decommissioning strategies and has been defined as a decommissioning strategy by which radioactive contaminants are encased in a structurally long lived material until radioactivity decays to a level permitting the unrestricted release of the facility, or release with restrictions imposed by the regulatory body. Although all three strategies have been considered, in principle, applicable to all facilities, their application to some facilities may not be appropriate owing to political concerns, safety or environmental requirements, technical considerations, local conditions or financial considerations. The IAEA is currently revising the decommissioning Safety Standards and one of the issues widely discussed has been the applicability of entombment in the context of decommissioning and its general objective to enable removal of regulatory control from the decommissioned facility. The IAEA recently established a consultancy to collect and discuss experience and lessons learned from entombment projects, to identify regulatory requirements and expectations for applying entombment as a decommissioning option strategy, in compliance with the internationally agreed standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Colonie, New York, FUSRAP Site: Pathway from Remediation to Redevelopment - 19465

The Colonie, New York, Formerly Utilized Sites Remedial Action Program (FUSRAP) Site consists of a 4.5-hectare (11.2-acre) US Department of Energy (DOE)-owned vacant property (Main Site) and 56 commercial and residential vicinity properties (VPs). The site was owned and operated by National Lead Industries (NL) from 1937 to 1984. The Main Site was used for manufacturing fuel and weapons components using uranium and thorium. Depleted uranium dust was emitted from exhaust stacks that contaminated the site and the VPs. NL also filled in portions of the site with industrial waste and released contaminants to groundwater. The state court shut the plant down in 1984. The site was acquired by DOE in 1985, which remediated the VPs and began to remediate the Main Site up to 1997. The US Army Corps of Engineers (USACE) undertook remedial actions beginning in 1997. The site has three Operable Units (Main Site, Groundwater, and VPs). The Main Site soil was remediated to residential standards except for three small easement areas. The soils in the easement areas are safe for exposure to workers. There is a groundwater plume beneath the site that will require the use of monitoring and temporary land use controls until cleanup standards are met. The VPs require no further action. A 2-year transition period from USACE to the DOE Office of Legacy Management (LM) began on June 18, 2018, with the receipt of the Site Closeout Report from USACE. LM has determined that the 4.5-hectare site is excess to its mission needs and intends to pursue sale of the property for redevelopment. There are several processes required before the disposal can occur. Organizations with similar sites that are federally owned and ready for private redevelopment may benefit from reviewing the Colonie site disposition processes. This paper will discuss (1) Determining disposal alternatives for the Colonie, New York, site. (2) Describing the federal requirements for the disposal of excess real property. (3) Communicating to stakeholders that the site is ready for disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling Mercury Release from Source Zones to Surface Water: Initial Results of Pilot Tests at the Y-12 National Security Complex

This report presents initial results obtained during year 2008 and satisfies a deliverable listed in the work breakdown structure (WBS) element OR081301. Broad objectives of the multi-year project are: (1) evaluation of remediation technologies for waterborne mercury, (2) development of treatment methods for soil mercury, and (3) source identification, characterization and analyses to improve mass balance on mercury estimates. This report presents the results of pilot tests, conducted in summer and fall 2008, which focused on remediation of waterborne mercury. The goal of this task is to develop strategies and treatment technologies that reduce the concentration and loading of waterborne mercury discharges to the UEFPC, thus minimizing mercury uptake by fish. The two specific studies are: (1) reducing flow augmentation in UEFPC to lessen mercury mobilization from contaminated stream sediments, and (2) treatment of contaminated source waters with a chemical reductant to convert dissolved mercury to a volatile form that can be removed by air stripping or natural evasion. Diversion of 50% of the flow currently added to UEFPC by the flow management system appeared to reduce mercury inputs from a localized, highly contaminated streambed by 0.6-1.5 grams per day (g/d). A reduction of 0.6 g/d represents {approx} 7-10% decrease in mercury input to UEFPC. Mercury concentrations within UEFPC did not rise proportionately with the loss of dilution, in part because of the reduction in input from the streambed source and in part because of reduced flow from the Y-12 NSC storm drain system. A longer-term test that includes seasonal variability will be the next step to validate these initial field observations of the flow diversion experiment. Preliminary laboratory experiments show that a large fraction ({approx} 90%) of the mercury can be chemically reduced to Hg(0) by addition of low concentrations of tin, Sn(II). Conversion of mercury to volatile Hg(0) in UEFPC was also demonstrated in the field by in-situ addition of low levels of Sn(II) in the headwaters. A substantial fraction ({approx} 30% of baseline mercury levels by the end of the experiment) of the mercury was converted from oxidation state II to 0. The addition of the dechlorinating agent sodium thiosulfate mobilized a small amount of additional mercury from the pipe through which EFPC flowed, but the excess Hg largely disappeared by the end of the chemical addition period. No excess tin was observed at the regulatory monitoring point, mercury levels in air were low, and no in-stream toxicity was observed. At a Hg(II) reduction efficiency of {approx} 30%, in-situ reduction coupled with air stripping has the potential to remove large quantities of mercury from the UEFPC flow. Air stripping has not been implemented, but a demonstration is planned for the next phase of field experiments. The initial results from this 2008 study suggest a combination of reducing augmented flow volume and chemical reduction using stannous chloride will produce at least a 35% reduction in baseflow mercury loading to UEFPC, from approximately 8 g/d to 5 g/d. The goal of research in 2009 and beyond will be to gain further improvements in each of these approaches.

54 ENVIRONMENTAL SCIENCES↗

Crickets{sup TM} and Curies: Lessons Learned from the Steel Industry - 18221

The global nuclear power industry, and to a lesser extent, the decommissioning and demolition of old nuclear weapons plants, obviously present challenges to those in the radioactive waste management field. Some if not many of these challenges have already been dealt with, and resolved, in the steel industry, including its recycling component. This paper presents proven state-of-the-art radiation detection systems used in steel and related recycling facilities, emphasizing current, reliable and flexible technologies for characterization, volume reduction, and remote handling of recyclable solid wastes contaminated and, just as important, not contaminated, with a wide range of radioactive isotopes. It will also cover features of remotely operated waste handling equipment effective in reducing or eliminating exposure of workers engaged in decontamination and demolition work on active and/or inactive nuclear installations. The industry group identified above has a long-standing policy regarding any radioactivity in potentially recyclable as well as waste materials it receives: if it is detected, it is rejected. The US Steel Manufacturers Association (SMA) put it this way in one of their Public Policy Statements: 'SMA members have not, and will not, accept scrap that is known to be radioactively contaminated' (emphasis included in the original) (1). This policy, adopted around the globe, obviously has major implications for decommissioning and demolition projects. To put it bluntly, if rad-contaminated metal, concrete, or other materials are sent to a facility for possible recycling, reuse or even disposal, they may well be rejected. If so, the materials will be returned to the generator--at the generator's cost-and a new solution will have to be found. This also results in additional costs for the generator. Facilities in the steel making and metal recycling industries have access to, and routinely count on, a wide range of proven detection technologies and techniques for monitoring incoming shipments and sorting the materials in them. The approaches range from using sensitive handheld instruments for pinpointing and isolating small devices such as isotope-containing gauges and radium dials all the way up to technologies effective for large volumes and weights of contaminated construction and demolition material. In this latter realm, the most suitable, robust, and field-proven system for decommissioning and demolition work is a radiation detection system fitted to a grappling and/or magnetic device, known as the Crickets{sup TM} technology, which automatically scans bulk material with no added effort or time in material handling operations. Highly versatile, a Crickets{sup TM} system can be put to work on any material-handling system, including grapples handling volumes ranging from 1 up to 18 cubic yards, while detecting radioactivity in real-time over a very wide dose range, from nSv to Sv levels. Other field-proven real-time measuring radiation detection devices can be fixed to conveyor belts with traverse speeds up 3 meters/second, also measuring in real time and over the same dose range, allowing both recyclable and waste materials with a pre-set level of radioactivity to be diverted off the belt. Finally, there are highly sensitive radiation portal installations for detecting radiation from materials being transported by vehicles, including those with roll-offs, dump trailers, and other containers, again in real-time and for the same dose ranges. For vehicles, the speed must be carefully controlled-the vehicles need to travel from 5 to 10 km/h through the scanning zone to ensure that maximum detection capability is maintained. When radiation detection systems at recycling and steel making facilities detect radioactive material in an incoming shipment, these facilities have a zero tolerance for accepting the cargo. Therefore, it is imperative that material from a demolition operation that is slated to be sent for recycling or other reuse be checked at the point of demolition at similar detection levels to avoid possible rejection later of a shipment because of its radioactivity. In addition to measuring overall radiation levels (for example, total gamma), when necessary, combinations of different radiation detection media can be used to detect the presence and intensities of specific isotopes such as U-235, Cs-137, Co-60, Am-241, etc., again in real-time and over a similar dose range. These detection technologies can be fixed or transportable. More important for the rad-waste management profession, this overall systems approach can be tailored and adapted during use on-site in any dismantling, demolition or remediation project, to allow materials to be thoroughly scanned before being released to the recycling stream for reuse, or to appropriate long-term storage and disposal facilities. Potentially recyclable materials with contamination such as steel beams and rebar will set off alarms at recycling facilities, resulting in unnecessary added expenses to the generator, primarily due to increased transportation costs, time delays and additional rad-waste handling and disposal charges. Additionally, there are situations where relatively lightly contaminated materials, once identified and appropriately characterized, can be reused in new construction applications, such as concrete from demolition being used in the base layer for roads or recycled steel used for repair or construction of bridges. In other cases, specific smaller volumes can be sent to specialized rad-waste disposal sites. These radiation detection systems can also be custom tailored to ensure proper handling and disposition of contaminated materials destined for reuse in specific applications where, for example, acceptable levels of radioactivity in NORM or TENORM can be reused or safely disposed of. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Swellable Organically Modified Silica (SOMS) as a Catalyst Scaffold for Catalytic Treatment of Water Contaminated with Trichloroethylene

The properties of a swellable organically modified silica (SOMS) scaffold allowed us to synthesize “smart” catalysts with tunable accessibility of the active sites induced by organic swelling agents. Pd nanoparticles (NPs) deposited inside the swollen matrix of SOMS were shown to be selectively located on the interior surface, a surface which is only available through swelling. Techniques such as near ambient-pressure X-ray photoelectron spectroscopy (NAP–XPS) and cryogenic scanning electron microscopy (SEM) were employed to characterize Pd/SOMS in its swollen as well as unswollen state because their conventional counterparts do not preserve the swollen state of Pd/SOMS during spectral acquisition. The results obtained depicted significant differences between the unswollen and swollen state of Pd/SOMS. The most important difference is that Pd NPs became accessible on the surface after exposure to an organic compound. This indicates that the accessibility of the active sites can be controlled by changing the reaction environment, hence allowing a tunable accessibility induced by organic swelling agents. The effects of the extent of swelling on the catalytic activity were investigated by performing catalytic activity experiments in the presence of an organic swelling agent. Hydrodechlorination (HDC) of trichloroethylene (TCE), an important method of catalytic water abatement, was chosen as a model reaction. The catalytic performance was found to be proportional to the concentration of the organic swelling agent, indicating that the accessibility of active sites is related to the concentration of organic compounds. While the unavoidable reaction product HCl inhibited the commonly used HDC catalyst 1%Pd/Al 2 O 3 , 1%Pd/SOMS was able to maintain its rate throughout the reaction under the same conditions, indicating its resistance to the inhibition. Overall, a silica-based catalyst with tunable accessibility of the active sites induced by changes in the reaction environment can have significant implications for heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic Strength-Controlled Mn (Hydr)oxide Nanoparticle Nucleation on Quartz: Effect of Aqueous Mn(OH) 2

The early formation of manganese (hydr)oxide nanoparticles at mineral–water interfaces is crucial in understanding how Mn oxides control the fate and transport of heavy metals and the cycling of nutrients. Using atomic force microscopy, we investigated the heterogeneous nucleation and growth of Mn (hydr)oxide under varied ionic strengths (IS; 1–100 mM NaNO 3 ). Experimental conditions (i.e., 0.1 mM Mn 2+ (aq) concentration and pH 10.1) were chosen to be relevant to Mn remediation sites. We found that IS controls Mn(OH) 2 (aq) formation, and that the controlled Mn(OH) 2 (aq) formation can affect the system’s saturation and subsequent Mn(OH) 2 (s) and further Mn 3 O 4 (s) nanoparticle formation. In 100 mM IS system, nucleated Mn (hydr)oxide particles had more coverage on the quartz substrate than those in 1 mM and 10 mM IS systems. This high IS also resulted in low supersaturation ratio and thus favor heterogeneous nucleation, having better structural matching between nucleating Mn (hydr)oxides and quartz. Here, the unique information obtained in this work improves our understanding of Mn (hydr)oxide formation in natural as well as engineered aqueous environments, such as groundwater contaminated by natural leachate and acid mine drainage remediation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Gamma Assay System for Characterizing Excavated Soil with High {sup 137}Cs and {sup 90}Sr Contamination - 19460

We report on the recent development of a remote gamma-assay system for the measurement and characterization of high-activity soil excavated as part of an ongoing remediation project. The soil below a hot cell in our customer's facility has been contaminated with high concentrations of radionuclides {sup 137}Cs and {sup 90}Sr over the past several decades. The contaminated soil is to be remotely excavated from beneath the hot cell floor, to a depth of several feet, and placed in steel-walled waste bins for assay and disposition. The project requires measuring the {sup 137}Cs activity to a minimum detectable concentration (MDC) of 1 micro curie per gram. The high dose-rate of the material and the expectation of high Bremsstrahlung background, due to an unknown ratio of {sup 90}Sr admixture with the {sup 137}Cs, present unique measurement challenges. A novel assay system was designed to make measurements through a small access port in a 4-foot thick concrete wall isolating operators from the high-dose excavation area. Waste bins filled with soil are placed by a remotely operated crane onto an automated turntable, and initial dose measurements are taken for all bins. When excavation has proceeded to the point that dose rates below 20 Rad/hr on contact are reached, gamma spectroscopy will be used to characterize the {sup 137}Cs content. Gamma assay is performed with a 1 cm{sup 3} CZT detector in a collimated tungsten shield, which is extended through the access port toward the side of the bin by means of a seven foot long aluminum pipe. Each of the four sides of the bin is assayed in a discrete measurement, and the individual segments and summed result are reported. Canberra's NDA2000 software is used to collect and analyze the spectroscopic data and to control the turntable movement during the assay. The system is expected to meet the required MDC limits within a forty minute assay time under the most adverse conditions anticipated, with total measurement uncertainty of less than 25%. We describe in this paper the design and construction of the assay system, its calibration using the ISOCS software, and the evaluation of performance estimates. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Water Sorption on Ionic Conductivity in Polyether Electrolytes at Low Hydration

Ion-containing polymers are subject to a wide range of hydration conditions across electrochemical and water treatment applications. Significant work on dry polymer electrolytes for batteries and highly swollen membranes for water purification has informed our understanding of ion transport under extreme conditions. However, knowledge of intermediate conditions (i.e., low hydration) is essential to emerging applications (e.g., electrolyzers, fuel cells, and lithium extraction). Ion transport under low levels of hydration is distinct from the extreme conditions typically investigated, and the relevant physics cannot be extrapolated from existing knowledge, stifling materials design. In this study, we conducted ion transport measurements in LiTFSI-doped polyethers that were systematically hydrated from dry conditions. A semiautomated apparatus that performs parallel measurements of water uptake and ionic conductivity in thin-film polymers under controlled humidity was developed. For the materials and swelling range considered in this study (i.e., <0.07 g water/g dry polymer electrolyte), ionic conductivity depends nonlinearly on water uptake, with the initial sorbed water weakly affecting conductivity. With additional increases in swelling, more significant increases in conductivity were observed. Remarkably, changes in conductivity induced by water sorption were correlated with the number of water molecules per lithium ion, with the normalized molar conductivity of different samples effectively collapsing onto one another until this unit of hydration exceeded the solvation number of lithium ions under aqueous conditions. Furthermore, these results provide important knowledge regarding the effects of trace water contamination on conductivity measurements in polymer electrolytes and demonstrate that the lithium-ion solvation number marks a key transition point regarding the influence of water on ion transport in ion-containing polymers.

36 MATERIALS SCIENCE↗

GrayQb Single-Faced Version 2 Open Environment Test - 16344

The GrayQb{sup TM} Single Faced Version 2 (SF2) is a non-destructive examination device developed to generate radiation contour maps showing source locations and relative radiological levels present in an area under examination. This device allows for characterization of radioactively contaminated areas such as hot cells, gloveboxes, small and large rooms, hallways, and waste tanks. The goal of GrayQb{sup TM} (pronounced 'Gray Cube') is to provide a low cost easily deployable device to aid in the process of decontamination and decommissioning (D and D). The GrayQb{sup TM} SF2 device is approximately a six inch cube weighing seven (7) pounds composed of a tungsten shield with integrated collimator, radiation imaging medium (Phosphor Storage Plate), and digital camera. This paper details the design upgrades incorporated into the new version of the GrayQb{sup TM} SF2 device and the characterization testing of this upgraded device. Device results from controlled testing performed at the Savannah River Site (SRS) Health Physics Instrument Calibration Laboratory (HPICL) are presented, as well as results from the open environment field testing performed in the E-Area Low Level Waste Storage Area. Follow on work performed deploying the GrayQb SF2 device at the Hanford Plutonium Reclamation Facility (PRF) to assist in the radiological characterization of the canyon will also be presented. Testing of the redesigned GrayQb{sup TM} SF2 device demonstrated its ability to detect low energy isotopes, e.g. Am-241 and Pu-238, not only indoors in controlled environments with well-defined source locations, but also in open environment field areas with a significant high energy background. Additionally, it was demonstrated that the device could detect higher energy isotopes (Cs-137 and Co-60) in a controlled setting and with additional testing and/or modifications to device and software, would likely be able to detect these isotopes in the open environment field testing. Follow on 2015 work performed at Hanford proved GrayQb to be a useful tool in the radiological characterization of the PRF canyon. Distribution tendencies of the radiological hot spots were identified that provided insights which will assist in more efficient planning of the continued D and D effort. Hot spots were identified which can be targeted during the future D and D effort and used as markers during the NDA assessment to quantify the radiological environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Accessory for Cleaning the Inside of the Machine Tool Cavity

The best way to extend the life of a metalworking fluid (MWF) is to make sure the machine tool and MWF delivery system are properly cleaned at least once per year. The dilemma the MWF manager is faced with is: How does one clean the machine tool and the MWF system on a large machine tool with an enclosure in a timely manner without impacting production schedules? Remember the walls and roof of the machine enclosure are coated with a film of dried contaminated MWF that must also be removed. If not removed, the deposits on these surfaces can recontaminate the fresh charge of MWF. I have found a product that with this revised procedure helps to shorten the machine tool down time involved with machine cleaning. (1) Discuss with your MWF supplier if they have a machine cleaning product that can be used with your current water based MWF during normal machining operations. Most MWF manufacturers have a machine cleaner that can be used at a lower concentration (1-2% vs. 5%) and can be used while still making production parts for a short period of time (usually 24-48 hours). (2) Make sure this machine cleaner is compatible with the work-piece material you are machining into product. Most cleaners are compatible with ferrous alloys. Because of the increased alkalinity of the fluid you might experience staining if you are machining copper or aluminum alloys. (3) Remove the chips from the chips pans and fluid channels. (4) During off shift hours circulate the MWF using a new product marketed by Rego-Fix called a 'Hydroball'. This device has a 5/8 inch diameter straight shank which allows it to be installed in any collet or solid quick change tool holder. It has multiple nozzles so that the user can control the spray pattern generated when the MWF is circulated. It allows the user to utilize the high pressure, through spindle MWF delivery capability of your machine tool for cleaning purposes. The high pressure MWF system can now be effectively used for cleaning purposes. This will also work with standard pressure system but you must reduce the number of nozzles utilized. By combining the movement of the machine axis around the operating envelope and the MWF circulation you can do a reasonably effective job of washing the inside of the machine tool operating cavity. Way covers will be moved and surfaces exposed because of axis movement. Spray direction will change to better wash fixtures and machine tool components. Deposits will start to breakdown and be washed into the machine tool sump. Since the cycle will run four or more hours it can be done with a weaker cleaning solution. The distributor states that the unit can be rotated up to 50 RPM. When running it has the same effect as the washing rotor inside of your home dishwasher. Inside the cavity on a machining center there is a lot of splash. During normal operations, MWF deposits buildup on the walls and roof of the enclosures. If these deposits (containing bacteria, mold and other contaminants) are not removed they will inoculate the fresh charge of MWF when they are resaturated. When you clean the inside of machine tool cavity, time is spent removing these deposits on the walls and roof of the enclosure. Getting to these surfaces is very difficult usually requiring that a member of the cleaning crew get inside the machine tool to reach them. The Hydro ball is effective in distributing the cleaning solution on all surfaces of the enclosure under high pressure. The only negative we have found is you get to find all the gaps and leaks in your machine tool enclosure. By running the hydro ball with the machine cleaner enriched MWF during off shift (4-8 hours) you can effectively remove these deposits and buildups on the internal surfaces of the cavity of the machine tool and wash them down into the sump. You also clean the internal components of the MWF system without interrupting normal scheduled work. (5) Pump out the spent MWF. You will have found that most of the deposits have been washed from the internal surfaces of the enclosure. For extremely dirty machines you might have to refill the machine tool with the normal machine cleaner mix. You will find that even heavy deposits will break down quicker because of this pre-wash cycle. (6) Rinse the machine cavity. (7) Clean the walls, bottom and screens in the MWF reservoir. The use of this tool and the dilute machine cleaner reduced the cleaning time considerately without affecting production schedules. (8) Refill with MWF and resume normal operations. What we like about this system is we can schedule these light cleanings just before a scheduled fluid change. Add the cleaner to the mix and run the Hydroball on second shift. The spent fluid is pumped out on third shift and the machine refilled. The machine tool with a fresh charge of MWF is ready for first shift without interrupting production schedules. We get better life from our MWFs and the machinists are happier about the condition of their machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Development of Catalysts for Upgrading of Pyrolysis Vapor for Refinery Feedstocks and Intermediates (CRADA Final Report)

Catalytic fast pyrolysis (CFP) is a versatile technology platform to convert biomass into fungible hydrocarbon transportation fuels and chemical co-products. Key technical barriers to reaching this goal include increasing the product yields and achieving the desired fuel properties for gasoline, diesel, and jet range fuels or blendstocks that would be suitable for introduction into existing refinery unit operations. Overcoming these barriers will require durable catalysts that are effective at upgrading and stabilizing biomass pyrolysis vapors. Towards these goals, this CRADA leveraged NREL experience as a leader in biomass pyrolysis research and Johnson Matthey's (JM) experience as a leader in the production of advanced catalytic materials. The scope spanned CFP catalyst development, characterization, multi-scale reaction testing, and computational modeling. CRADA benefits to DOE, Participant, and U.S. Taxpayer: Assists laboratory in achieving programmatic scope, Uses the laboratory’s core competencies. The purpose of this CRADA was to develop and deploy catalysts for biomass CFP to help achieve cost-competitive biofuels and bio-based products. This was accomplished through a close collaboration between biomass conversion researchers at NREL and catalyst development researchers at JM. Summary of Research Results: Focus Area 1. Foundational research on catalytic conversion and deactivation: Key interactions between pyrolysis vapors and heterogeneous catalysts were probed through catalyst characterization, model compound reaction testing, and atomistic-scale computational modeling. Catalyst development focused on multifunctional materials, which include zeolites, oxides, carbides, and nitrides. Computational modeling identified reaction mechanisms and elucidated surface chemistry to test hypotheses regarding mechanisms of deoxygenation, coupling, cracking, dehydration, coke formation, hydrogen transfer, and aromatic ring reactions. This information was used to design multifunctional catalysts to increase product yields, control product selectivity, and reduce deactivation during CFP and downstream processing steps. The results served to increase fundamental understanding of key catalyst attributes and durability features for the upgrading of biomass pyrolysis vapors. Model compound experiments confirmed the importance of metal-acid bifunctionality for the deoxygenation of lignin-derived phenolic species under hydrodeoxygenation conditions. This insight led to the development of catalysts such as Pt/TiO2 and Mo2C, which were confirmed as high-performing materials during subsequent bench-scale experiments using biomass-derived pyrolysis vapors. This focus area also led to the identification of important catalyst deactivation mechanisms associated with the deposition of inorganic contaminants such as potassium. The molecular-level insight from model compound experiments and computational modeling, shown in Figure 1, informed the development of regeneration procedures that have been shown to be effective for restoration of > 90% of initial catalyst activity. This understanding has subsequently been translated to other catalyst systems, including zeolite materials that can be operated without requirements for co-fed hydrogen.

09 BIOMASS FUELS↗

A search for particle dark matter using cryogenic germanium and silicon detectors in the one- and two- tower runs of CDMS-II at Soudan

Images of the Bullet Cluster of galaxies in visible light, X-rays, and through gravitational lensing confirm that most of the matter in the universe is not composed of any known form of matter. The combined evidence from the dynamics of galaxies and clusters of galaxies, the cosmic microwave background, big bang nucleosynthesis, and other observations indicates that 80% of the universe's matter is dark, nearly collisionless, and cold. The identify of the dar, matter remains unknown, but weakly interacting massive particles (WIMPs) are a very good candidate. They are a natural part of many supersymmetric extensions to the standard model, and could be produced as a nonrelativistic, thermal relic in the early universe with about the right density to account for the missing mass. The dark matter of a galaxy should exist as a spherical or ellipsoidal cloud, called a 'halo' because it extends well past the edge of the visible galaxy. The Cryogenic Dark Matter Search (CDMS) seeks to directly detect interactions between WIMPs in the Milky Way's galactic dark matter halo using crystals of germanium and silicon. Our Z-sensitive ionization and phonon ('ZIP') detectors simultaneously measure both phonons and ionization produced by particle interactions. In order to find very rare, low-energy WIMP interactions, they must identify and reject background events caused by environmental radioactivity, radioactive contaminants on the detector,s and cosmic rays. In particular, sophisticated analysis of the timing of phonon signals is needed to eliminate signals caused by beta decays at the detector surfaces. This thesis presents the firs two dark matter data sets from the deep underground experimental site at the Soudan Underground Laboratory in Minnesota. These are known as 'Run 118', with six detectors (1 kg Ge, 65.2 live days before cuts) and 'Run 119', with twelve detectors (1.5 kg Ge, 74.5 live days before cuts). They have analyzed all data from the two runs together in a single, combined analysis, with sensitivity to lower-energy interactions, careful control of data quality and stability, and further development of techniques for reconstructing event location and rejecting near-surface interactions from beta decays. They also present a revision to the previously published Run 119 analysis, a demonstration of the feasibility of a low-threshold (1 or 2 keV) analysis of Soudan data, and a review of the literature on charge generation and quenching relevant to the ionization signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗