Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computer Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy

Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to a digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-130: [18F]-FDG Uptake Dose Response in Lung Correlates Linearly with Proton Therapy Dose

Purpose: Analysis of clinical outcomes in lung cancer patients treated with protons using 18F-FDG uptake in lung as a measure of dose response. Methods: A test case lung cancer patient was selected in an unbiased way. The test patient’s treatment planning and post treatment positron emission tomography (PET) were collected from picture archiving and communication system at the UT M.D. Anderson Cancer Center. Average computerized tomography scan was registered with post PET/CT through both rigid and deformable registrations for selected region of interest (ROI) via VelocityAI imaging informatics software. For the voxels in the ROI, a system that extracts the Standard Uptake Value (SUV) from PET was developed, and the corresponding relative biological effectiveness (RBE) weighted (both variable and constant) dose was computed using the Monte Carlo (MC) methods. The treatment planning system (TPS) dose was also obtained. Using histogram analysis, the voxel average normalized SUV vs. 3 different doses was obtained and linear regression fit was performed. Results: From the registration process, there were some regions that showed significant artifacts near the diaphragm and heart region, which yielded poor r-squared values when the linear regression fit was performed on normalized SUV vs. dose. Excluding these values, TPS fit yielded mean r-squared value of 0.79 (range 0.61–0.95), constant RBE fit yielded 0.79 (range 0.52–0.94), and variable RBE fit yielded 0.80 (range 0.52–0.94). Conclusion: A system that extracts SUV from PET to correlate between normalized SUV and various dose calculations was developed. A linear relation between normalized SUV and all three different doses was found.

60 APPLIED LIFE SCIENCES↗

PARALLEL IMPLEMENTATION OF THE TOPAZ OPACITY CODE: ISSUES IN LOAD-BALANCING

The TOPAZ opacity code explicitly includes configuration term structure in the calculation of bound-bound radiative transitions. This approach involves myriad spectral lines and requires the large computational capabilities of parallel processing computers. It is important, however, to make use of these resources efficiently. For example, an increase in the number of processors should yield a comparable reduction in computational time. This proportional 'speedup' indicates that very large problems can be addressed with massively parallel computers. Opacity codes can readily take advantage of parallel architecture since many intermediate calculations are independent. On the other hand, since the different tasks entail significantly disparate computational effort, load-balancing issues emerge so that parallel efficiency does not occur naturally. Several schemes to distribute the labor among processors are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

OPTIMIZED MULTI-FREQUENCY SPECTRA FOR APPLICATIONS IN RADIATIVE FEEDBACK AND COSMOLOGICAL REIONIZATION

The recent implementation of radiative transfer algorithms in numerous hydrodynamics codes has led to a dramatic improvement in studies of feedback in various astrophysical environments. However, because of methodological limitations and computational expense, the spectra of radiation sources are generally sampled at only a few evenly spaced discrete emission frequencies. Using one-dimensional radiative transfer calculations, we investigate the discrepancies in gas properties surrounding model stars and accreting black holes that arise solely due to spectral discretization. We find that even in the idealized case of a static and uniform density field, commonly used discretization schemes induce errors in the neutral fraction and temperature by factors of two to three on average, and by over an order of magnitude in certain column density regimes. The consequences are most severe for radiative feedback operating on large scales, dense clumps of gas, and media consisting of multiple chemical species. We have developed a method for optimally constructing discrete spectra, and show that for two test cases of interest, carefully chosen four-bin spectra can eliminate errors associated with frequency resolution to high precision. Applying these findings to a fully three-dimensional radiation-hydrodynamic simulation of the early universe, we find that the H II region around a primordial star is substantially altered in both size and morphology, corroborating the one-dimensional prediction that discrete spectral energy distributions can lead to sizable inaccuracies in the physical properties of a medium, and as a result, the subsequent evolution and observable signatures of objects embedded within it.

79 ASTRONOMY AND ASTROPHYSICS↗

XIM-A VIRTUAL X-RAY OBSERVATORY: INVESTIGATING THE X-RAY APPEARANCE AND LINE PROFILE FUNCTION OF VORTEX RINGS IN GALAXY CLUSTERS

We present virtual observations of a simulated vortex ring in a galaxy cluster (such as the Virgo Cluster, where such a ring has been observed), using the virtual X-ray observatory software XIM. We derive the expected surface brightness distributions and color maps for a vortex seen at different line-of-sight angles. We present the line profile function {phi}({delta}{nu}) for the velocity field of a vortex ring as derived from the observations and show that the line core has a frequency dependence of {phi} {proportional_to} ({delta}{nu}/{nu}{sub 0}){sup -2} and derive this form of the line profile from the analytic description of the asymptotic behavior of the velocity field of a vortex ring. We discuss further examples of the application of XIM to studies of galaxy clusters and present the capabilities and methodology of the publicly available code XIM.

79 ASTRONOMY AND ASTROPHYSICS↗

Helium trimer calculations with a public quantum three-body code

We present an illustration of using a quantumthree-body code being prepared for public release. The code is based on iterative solving of the three-dimensional Faddeev equations. The code is easy to use and allows users to perform highly-accurate calculations of quantum three-body systems. The previously known results for He{sub 3} ground state are well reproduced by the code.

74 ATOMIC AND MOLECULAR PHYSICS↗

Disruptive Innovation in Numerical Hydrodynamics

We propose the research and development of a high-fidelity hydrodynamic algorithm for tetrahedral meshes that will lead to a disruptive innovation in the numerical modeling of Laboratory problems. Our proposed innovation has the potential to reduce turnaround time by orders of magnitude relative to Advanced Simulation and Computing (ASC) codes; reduce simulation setup costs by millions of dollars per year; and effectively leverage Graphics Processing Unit (GPU) and future Exascale computing hardware. If successful, this work will lead to a dramatic leap forward in the Laboratory's quest for a predictive simulation capability.

97 MATHEMATICS AND COMPUTING↗

RELAP5-3D Developer Guidelines and Programming Practices

Our ultimate goal is to create and maintain RELAP5-3D as the best software tool available to analyze nuclear power plants. This begins with writing excellent programming and requires thorough testing. This document covers development of RELAP5-3D software, the behavior of the RELAP5-3D program that must be maintained, and code testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuous Energy, Multi-Dimensional Transport Calculations for Problem Dependent Resonance Self-Shielding

The overall objective of the work here has been to eliminate the approximations used in current resonance treatments by developing continuous energy multi-dimensional transport calculations for problem dependent self-shielding calculations. The work here builds on the existing resonance treatment capabilities in the ORNL SCALE code system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Do Programmers Prefer Predictable Expressions in Code?

Source code is a form of human communication, albeit one where the information shared between the programmers reading and writing the code is constrained by the requirement that the code executes correctly. Programming languages are more syntactically constrained than natural languages, but they are also very expressive, allowing a great many different ways to express even very simple computations. Still, code written by developers is highly predictable, and many programming tools have taken advantage of this phenomenon, relying on language model surprisal as a guiding mechanism. Additionally, while surprisal has been validated as a measure of cognitive load in natural language, its relation to human cognitive processes in code is still poorly understood. In this paper, we explore the relationship between surprisal and programmer preference at a small granularity—do programmers prefer more predictable expressions in code? Using meaning-preserving transformations, we produce equivalent alternatives to developer-written code expressions and run a corpus study on Java and Python projects. In general, language models rate the code expressions developers choose to write as more predictable than these transformed alternatives. Then, we perform two human subject studies asking participants to choose between two equivalent snippets of Java code with different surprisal scores (one original and transformed). We find that programmers do prefer more predictable variants, and that stronger language models like the transformer align more often and more consistently with these preferences.

97 MATHEMATICS AND COMPUTING↗

PAKAL: A THREE-DIMENSIONAL MODEL TO SOLVE THE RADIATIVE TRANSFER EQUATION

We present a new numerical model called 'Pakal' intended to solve the radiative transfer equation in a three-dimensional (3D) geometry, using the approximation for a locally plane-parallel atmosphere. Pakal uses pre-calculated radial profiles of density and temperature (based on hydrostatic, hydrodynamic, or MHD models) to compute the emission from 3D source structures with high spatial resolution. Then, Pakal solves the radiative transfer equation in a set of (3D) ray paths, going from the source to the observer. Pakal uses a new algorithm to compute the radiative transfer equation by using an intelligent system consisting of three structures: a cellular automaton; an expert system; and a program coordinator. The code outputs can be either two-dimensional maps or one-dimensional profiles, which reproduce the observations with high accuracy, giving detailed physical information about the environment where the radiation was generated and/or transmitted. We present the model applied to a 3D solar radial geometry, assuming a locally plane-parallel atmosphere, and thermal free-free radio emission from hydrogen-helium gas in thermodynamic equilibrium. We also present the convergence test of the code. We computed the synthetic spectrum of the centimetric-millimetric solar emission and found better agreement with observations (up to 10{sup 4} K at 20 GHz) than previous models reported in the literature. The stability and convergence test show the high accuracy of the code. Finally, Pakal can improve the integration time by up to an order of magnitude compared against linear integration codes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure of neutron-rich nuclei around the N = 50 shell-gap closure

The structure of neutron-rich nuclei in the vicinity of {sup 78}Ni have been investigated via the beta-decay of {sup 71,73,75}Cu isotopes (ISOLDE, CERN). Experimental results have been compared with shell-model calculations performed with the ANTOINE code using a large (2p{sub 3/2}1 f{sub 5/2}2 p{sub 1/2}1 g{sub 9/2}) valence space and a (56/28)Ni{sub 28} core.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Steady-state benchmarks of DK4D: A time-dependent, axisymmetric drift-kinetic equation solver

The DK4D code has been written to solve a set of time-dependent, axisymmetric, finite-Larmor-radius drift-kinetic equations (DKEs) for the non-Maxwellian part of the electron and ion distribution functions using the full, linearized Fokker–Planck–Landau collision operator. The plasma is assumed to be in the low- to finite-collisionality regime, as is found in the cores of modern and future magnetic confinement fusion experiments. Each DKE is formulated such that the perturbed distribution function carries no net density, parallel momentum, or kinetic energy. Rather, these quantities are contained within the background Maxwellians and would be evolved by an appropriate set of extended magnetohydrodynamic (MHD) equations. This formulation allows for straight-forward coupling of DK4D to existing extended MHD time evolution codes. DK4D uses a mix of implicit and explicit temporal representations and finite element and spectral spatial representations. These, along with other computational methods used, are discussed extensively. Steady-state benchmarks are then presented comparing the results of DK4D to expected analytic results at low collisionality, qualitatively, and to the Sauter analytic fits for the neoclassical conductivity and bootstrap current, quantitatively. These benchmarks confirm that DK4D is capable of solving for the correct, gyroaveraged distribution function in stationary magnetic equilibria. Furthermore, the results presented demonstrate how the exact drift-kinetic solution varies with collisionality as a function of the magnetic moment and the poloidal angle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CMAD: A Self-consistent Parallel Code to Simulate the Electron Cloud Build-up and Instabilities

We present the features of CMAD, a newly developed self-consistent code which simulates both the electron cloud build-up and related beam instabilities. By means of parallel (Message Passing Interface - MPI) computation, the code tracks the beam in an existing (MAD-type) lattice and continuously resolves the interaction between the beam and the cloud at each element location, with different cloud distributions at each magnet location. The goal of CMAD is to simulate single- and coupled-bunch instability, allowing tune shift, dynamic aperture and frequency map analysis and the determination of the secondary electron yield instability threshold. The code is in its phase of development and benchmarking with existing codes. Preliminary results on benchmarking are presented in this paper.

43 PARTICLE ACCELERATORS↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-201-07: Validation of a GATE Gamma Camera Model for the Siemens Symbia

Purpose: To develop a simulation model of a clinical gamma camera/SPECT system and to validate the model using experimental and published measurements from the clinical system. Methods: Geant4 Application for Tomographic Emission (GATE) was used to create a model of the Siemens Symbia gamma camera. A modular model was implemented that allows specifying combinations of crystal thickness (3/8”, 5/8”) and collimator (LEHR, MELP, HE). Shielding, energy resolution, intrinsic resolution, crystal thickness, and collimator properties were set based on manufacturer specifications. Validation of the model was performed by simulating NEMA 2007 gamma camera tests including spatial resolution and sensitivity for Tc99; these were compared with experimental and published data for the scanner. The simulated energy spectra of a Tc99 line source in acrylic blocks was visually compared with the corresponding experimental acquisition. For a 4 cm diameter sphere filled with Tc99, the attenuation maps were generated from simulation data, and the photopeak and scatter window were extracted from GATE output using ROOT to create DICOM files to use in the clinical reconstruction. Results: Simulated spatial resolutions for LEHR 3/8” crystal at 0, 10 cm, 10 cm (with scatter), and 30 cm were 4, 6.7, 7.9, and 14.5 mm FWHM; these were 9% less than published data. For 5/8” crystal the spatial resolutions were 4.5, 7.0, 8.5, and 14.7 mm FWHM; these were 4% to 10% less than published data. Simulated sensitivity was within 3.5% of published data for both LEHR 3/8” and 5/8”. The simulated energy spectra matched the photopeak and scatter window well, but did overestimate the counts below 90 keV. The simulated attenuation map and projection data were successfully reconstructed with the clinical software, and the passed visual inspection. Conclusions: Validation of a specific clinical scanner allows future studies of quantification accuracy for both planar and SPECT imaging. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

SU-F-R-45: The Prognostic Value of Radiotherapy Based On the Changes of Texture Features Between Pre-Treatment and Post-Treatment FDG PET Image for NSCLC Patients

Purpose: The purpose of this research is investigating which texture features extracted from FDG-PET images by gray-level co-occurrence matrix(GLCM) have a higher prognostic value than the other texture features. Methods: 21 non-small cell lung cancer(NSCLC) patients were approved in the study. Patients underwent 18F-FDG PET/CT scans with both pre-treatment and post-treatment. Firstly, the tumors were extracted by our house developed software. Secondly, the clinical features including the maximum SUV and tumor volume were extracted by MIM vista software, and texture features including angular second moment, contrast, inverse different moment, entropy and correlation were extracted using MATLAB.The differences can be calculated by using post-treatment features to subtract pre-treatment features. Finally, the SPSS software was used to get the Pearson correlation coefficients and Spearman rank correlation coefficients between the change ratios of texture features and change ratios of clinical features. Results: The Pearson and Spearman rank correlation coefficient between contrast and SUV maximum is 0.785 and 0.709. The P and S value between inverse difference moment and tumor volume is 0.953 and 0.942. Conclusion: This preliminary study showed that the relationships between different texture features and the same clinical feature are different. Finding the prognostic value of contrast and inverse difference moment were higher than the other three textures extracted by GLCM.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-07: Image-Based Versus Atlas-Based Internal Dosimetry

Purpose: Monte Carlo (MC) simulation is known as the gold standard method for internal dosimetry. It requires radionuclide distribution from PET or SPECT and body structure from CT for accurate dose calculation. The manual or semi-automatic segmentation of organs from CT images is a major obstacle. The aim of this study is to compare the dosimetry results based on patient’s own CT and a digital humanoid phantom as an atlas with pre-specified organs. Methods: SPECT-CT images of a 50 year old woman who underwent bone pain palliation with Samarium-153 EDTMP for osseous metastases from breast cancer were used. The anatomical date and attenuation map were extracted from SPECT/CT and three XCAT digital phantoms with different BMIs (i.e. matched (38.8) and unmatched (35.5 and 36.7) with patient’s BMI that was 38.3). Segmentation of patient’s organs in CT image was performed using itk-SNAP software. GATE MC Simulator was used for dose calculation. Specific absorbed fractions (SAFs) and S-values were calculated for the segmented organs. Results: The differences between SAFs and S-values are high using different anatomical data and range from −13% to 39% for SAF values and −109% to 79% for S-values in different organs. In the spine, the clinically important target organ for Samarium Therapy, the differences in the S-values and SAF values are higher between XCAT phantom and CT when the phantom with identical BMI is employed (53.8% relative difference in S-value and 26.8% difference in SAF). However, the whole body dose values were the same between the calculations based on the CT and XCAT with different BMIs. Conclusion: The results indicated that atlas-based dosimetry using XCAT phantom even with matched BMI for patient leads to considerable errors as compared to image-based dosimetry that uses the patient’s own CT Patient-specific dosimetry using CT image is essential for accurate results.

60 APPLIED LIFE SCIENCES↗