Bulk Nano Structured Thermoelectric Materials for Building Air Conditioning and Commercial Refrigeration Applications
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
What if your building could “tell” you how to save money? PNNL is inventing systems to turn buildings from passive users of energy into active participants in the power system—making the buildings we work or live in “work” for us instead. We’re researching how buildings can respond intelligently to the natural environment, evolving grid conditions and dynamic occupant demands—not simply bracing for those external factors. Why do buildings matter to our energy future? Senior Engineer Nora Wang says it’s because buildings account for 75 percent of U.S. electricity consumption and 40 percent of our nation’s energy use overall. That equates to $430 billion in energy bills every year. Powering U.S. buildings contributes more than 2,200 million metric tons of carbon dioxide to the atmosphere annually—more than the total emissions of Russia and Canada combined.
The commercial and industrial building sectors have a major role to play in a U.S. low-carbon future. Building owners can make a difference by deploying on-site renewable generation and storage technologies, which facilitates future-proofing their buildings as well as more effectively meeting the service requirements of the building. This resource provides an overview of common generation, storage, and load management technologies in behind-the-meter systems, and serves as a primer to demonstrate the impact on net building loads required from the grid for different sizes of renewable generation along with on-site electrical and thermal storage. These discussions can help commercial building owners communicate the value of these systems to project teams and develop innovative behind-the-meter solutions to achieve their energy goals.
This dataset provides high-fidelity time series data for an emulated commercial office building sited in the Chicago, IL area during a Typical Meteorological Year (TMY). This dataset consists of air-side HVAC measurements and control inputs, and it includes normal operations as well as various implemented faults (with associated ground truth measurements) implemented on selected days. This data could be used to quantify and compare the impacts of different faults, and it could also be used as training or validation data for machine learning algorithms (e.g., reduced-order modelling, fault detection and diagnosis).
The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.
These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equipment (rooftop unit, single-duct air handler unit, dual-duct air handler unit, variable air volume box, fan coil unit, chiller plant, and boiler plant). Each dataset includes a .pdf file to document key information necessary to understand the content and scope, multiple csv files containing all the time-series data for faults at different severity levels and one fault-free case, and a ttl file to visualize the data according to BRICK schema. The dataset was created by LBNL, PNNL, NREL, ORNL and Drexel University.
Connected communities potentially offer much greater demand response capabilities over singular building energy management systems (BEMS) through an increase of connectivity. The potential increase in benefits from this next step in connectivity is still under investigation, especially when applied to existing buildings. This work utilizes EnergyPlus simulation results on eight different commercial prototype buildings to estimate the potential savings on peak demand and energy costs using a mixed-integer linear programming model. This model is used in two cases: a fully connected community and eight separate buildings with BEMS. The connected community is optimized using all zones as variables, while the individual buildings are optimized separately and then aggregated. These optimization problems are run for a range of individual zone flexibility values. The results indicate that a connected community offered 60.0% and 24.8% more peak demand savings for low and high flexibility scenarios, relative to individually optimized buildings. Energy cost optimization results show only marginally better savings of 2.9% and 6.1% for low and high flexibility, respectively.
The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.
This resource provides guidance for building owners to help them select the right control strategy for plug and process loads (PPLs) in their buildings. It includes guidance for multiple different building types and outline the costs, potential savings, complexities, and user friendliness of various control strategies and their applications to each building type.
This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.
In July 2010, the U.S. Department of Energy (DOE) awarded funding to PECI to develop training curriculum in commercial energy auditing and building commissioning. This program was created in response to the high demand for auditing and commissioning services in the U.S. commercial buildings market and to bridge gaps and barriers in existing training programs. Obstacles addressed included: lack of focus on entry level candidates; prohibitive cost and time required for training; lack of hands-on training; trainings that focus on certifications & process overviews; and lack of comprehensive training. PECI organized several other industry players to create a co-funded project sponsored by DOE, PECI, New York State Energy and Research Development Authority (NYSERDA), California Energy Commission (CEC), Northwest Energy Efficiency Alliance (NEEA) and California Commissioning Collaborative (CCC). After awarded, PECI teamed with another DOE awardee, New Jersey Institute of Technology (NJIT), to work collaboratively to create one comprehensive program featuring two training tracks. NJIT’s Center for Building Knowledge is a research and training institute affiliated with the College of Architecture and Design, and provided e-learning and video enhancements. This project designed and developed two training programs with a comprehensive, energy-focused curriculum to prepare new entrants to become energy auditors or commissioning authorities (CxAs). The following are the key elements of the developed trainings, which is depicted graphically in Figure 1: • Online classes are self-paced, and can be completed anywhere, any time • Commissioning Authority track includes 3 online modules made up of 24 courses delivered in 104 individual lessons, followed by a 40 hour hands-on lab. Total time required is between 75 and 100 hours, depending on the pace of the independent learner. • Energy Auditor track includes 3 online modules made up of 18 courses delivered in 72 individual lessons, followed by a 24 hour hands-on lab. Total time required is between 50 and 70 hours, depending on the pace of the independent learner. • Individual courses can be taken for continuing education credits. • Assessments are included for each course, and a score of at least 80% is required for completion. • Completion of Modules 1 through 3 is prerequisite for participating in the laboratory. More experienced participants have the option to test out of Modules 1 and 2 and complete Module 3 to progress to the laboratory.
The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.
This document provides guidance on designing a productive stakeholder engagement and outreach strategy to support the development of whole-building data access solutions as part of a successful energy benchmarking policy for buildings.
Purpose and Audience A wide spectrum of laboratory owners, ranging from universities to federal agencies, have explicit goals for energy efficiency and greenhouse gas reductions in their facilities. For example, new federal buildings and major renovations of existing buildings are to reduce fossil fuel-generated energy consumption by 90% in 2025, and 100% in 2030, compared with a 2003 baseline (FEMP n.d.). Minnesota SB2030 standard requires achieving an 80% reduction from the average building baseline for commercial, institutional, and industrial buildings (SB2030 n.d). A laboratory—new or existing—is much more likely to meet energy efficiency goals if quantitative metrics and targets are explicitly specified and tracked over the life cycle of the building, from design through construction, commissioning, operations, and renovations. If efficiency targets are not explicitly and properly defined, any additional capital costs or design time associated with attaining higher efficiencies can be difficult to justify relative to other priorities. The purpose of this guide is to provide guidance on how to specify and compute energy efficiency metrics and benchmarks for laboratories, at the whole-building as well as the system level. The information in this guide can be used to incorporate quantitative metrics and targets into new construction or retrofit of existing facilities. For information on strategies and technologies to achieve energy efficiency, the reader is referred to I2SL resources, including technology best practice guides and case studies.
This case study details a project completed by Efficiency Vermont to install 66 high-efficiency rooftop unit replacements on a large 140,000-square-foot office building, which realized 163 kW in electricity demand reduction and $93,000 annual utility cost savings.
This report features best practices for utilities on providing building owners with access to whole-building energy data for the purpose of benchmarking their energy use. It summarizes the key components of developing a whole building data access solution and provides recommendations for overcoming process-oriented barriers.
The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.
This case study highlights the strategies Denver Water used at its Administration Building for integrating HVAC and lighting systems. They employed advanced lighting controls, integrated with building automation systems, as well as lighting system occupancy sensors integrated with HVAC controls. The project was recognized by DOE's Integrated Lighting Campaign.