Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONDENSATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Transient Response to Rapid Cooling of a Stainless Steel Sodium Heat Pipe

Compact fission power systems are under consideration for use in long duration space exploration missions. Power demands on the order of 500 W, to 5 kW, will be required for up to 15 years of continuous service. One such small reactor design consists of a fast spectrum reactor cooled with an array of in-core alkali metal heat pipes coupled to thermoelectric or Stirling power conversion systems. Heat pipes advantageous attributes include a simplistic design, lack of moving parts, and well understood behavior. Concerns over reactor transients induced by heat pipe instability as a function of extreme thermal transients require experimental investigations. One particular concern is rapid cooling of the heat pipe condenser that would propagate to cool the evaporator. Rapid cooling of the reactor core beyond acceptable design limits could possibly induce unintended reactor control issues. This paper discusses a series of experimental demonstrations where a heat pipe operating at near prototypic conditions experienced rapid cooling of the condenser. The condenser section of a stainless steel sodium heat pipe was enclosed within a heat exchanger. The heat pipe - heat exchanger assembly was housed within a vacuum chamber held at a pressure of 50 Torr of helium. The heat pipe was brought to steady state operating conditions using graphite resistance heaters then cooled by a high flow of gaseous nitrogen through the heat exchanger. Subsequent thermal transient behavior was characterized by performing an energy balance using temperature, pressure and flow rate data obtained throughout the tests. Results indicate the degree of temperature change that results from a rapid cooling scenario will not significantly influence thermal stability of an operating heat pipe, even under extreme condenser cooling conditions.

Mireles, Omar R.↗

Fibrous-Ceramic/Aerogel Composite Insulating Tiles

Fibrous-ceramic/aerogel composite tiles have been invented to afford combinations of thermal-insulation and mechanical properties superior to those attainable by making tiles of fibrous ceramics alone or aerogels alone. These lightweight tiles can be tailored to a variety of applications that range from insulating cryogenic tanks to protecting spacecraft against re-entry heating. The advantages and disadvantages of fibrous ceramics and aerogels can be summarized as follows: Tiles made of ceramic fibers are known for mechanical strength, toughness, and machinability. Fibrous ceramic tiles are highly effective as thermal insulators in a vacuum. However, undesirably, the porosity of these materials makes them permeable by gases, so that in the presence of air or other gases, convection and gas-phase conduction contribute to the effective thermal conductivity of the tiles. Other disadvantages of the porosity and permeability of fibrous ceramic tiles arise because gases (e.g., water vapor or cryogenic gases) can condense in pores. This condensation contributes to weight, and in the case of cryogenic systems, the heat of condensation undesirably adds to the heat flowing to the objects that one seeks to keep cold. Moreover, there is a risk of explosion associated with vaporization of previously condensed gas upon reheating. Aerogels offer low permeability, low density, and low thermal conductivity, but are mechanically fragile. The basic idea of the present invention is to exploit the best features of fibrous ceramic tiles and aerogels. In a composite tile according to the invention, the fibrous ceramic serves as a matrix that mechanically supports the aerogel, while the aerogel serves as a low-conductivity, low-permeability filling that closes what would otherwise be the open pores of the fibrous ceramic. Because the aerogel eliminates or at least suppresses permeation by gas, gas-phase conduction, and convection, the thermal conductivity of such a composite even at normal atmospheric pressure is not much greater than that of the fibrous ceramic alone in a vacuum.

White, Susan M.↗

In-Service Monitoring of Steam Pipe Systems at High Temperatures

An effective, in-service health monitoring system is needed to track water condensation in real time through the walls of steam pipes. The system is required to measure the height of the condensed water from outside the pipe, while operating at temperatures that are as high as 250 C. The system needs to account for the effects of water flow and cavitation. In addition, it is desired that the system does not require perforating the pipes and thereby reducing the structural integrity. Generally, steam pipes are used as part of the district heating system carrying steam from central power stations under the streets to heat, cool, or supply power to high-rise buildings and businesses. This system uses ultrasonic waves in pulse-echo and acquires reflected signal data. Via autocorrelation, it determines the water height while eliminating the effect of noise and multiple reflections from the wall of the pipe. The system performs nondestructive monitoring through the walls of steam pipes, and automatically measures the height of condensed water while operating at the high-temperature conditions of 250 C. For this purpose, the ultrasonic pulse-echo method is used where the time-of-flight of the wave reflections inside the water are measured, and it is multiplied by the wave velocity to determine the height. The pulse-echo test consists of emitting ultrasonic wave pulses from a piezoelectric transducer and receiving the reflections from the top and bottom of the condensed water. A single transducer is used as a transmitter as well as the receiver of the ultrasonic waves. To obtain high resolution, a broadband transducer is used and the frequency can be in the range of 2.25 to 10 MHz, providing sharp pulses in the time domain allowing for higher resolution in identifying the individual reflections.

Bar-Cohen, Yoseph↗

Mineralogical Studies of a Highly O-17-Depleted and an O-17-Rich Presolar Grain from the Acfer 094 Meteorite

Silicate grains are the most abundant condensate around O-rich evolved stars, including red giants, supernovae (SNe) and binary systems. These grains have been identified in abundance in primitive meteorites and interplanetary dust particles [1,2]. Astronomical observations of the silicate spectroscopic features around circumstellar disks indicate that most silicates are amorphous olivine-like grains, though some sources show a large crystalline portion [3]. Fewer astronomical observations of SN and nova silicates exist, but amorphous Mg-rich grains predominate [4,5]. The laboratory analysis of presolar silicates by transmission electron microscopy (TEM) offers more details on the structure and chemistry of individual grains. These studies provide information on the physical and chemical conditions of the parent stellar atmosphere during grain condensation. Moreover, be-cause silicates are susceptible to secondary alteration, processing events succeeding condensation can be traced. Thus far, similar microstructures have been observed for silicates that condensed in SN outflows and in the envelopes of asymptotic giant branch (AGB) stars, but not as many of the comparatively rare SN grains have been analyzed. Here we examine the mineralogies of two presolar silicate grains having different origins.

Nguyen, A. N.↗

Radiative Impacts of Cloud Heterogeneity and Overlap in an Atmospheric General Circulation Model

The radiative impacts of introducing horizontal heterogeneity of layer cloud condensate, and vertical overlap of condensate and cloud fraction are examined with the aid of a new radiation package operating in the GEOS-5 Atmospheric General Circulation Model. The impacts are examined in terms of diagnostic top-of-the-atmosphere shortwave (SW) and longwave (LW) cloud radiative effect (CRE) calculations for a range of assumptions and parameter specifications about the overlap. The investigation is conducted for two distinct cloud schemes, the one that comes with the standard GEOS-5 distribution, and another which has been recently used experimentally for its enhanced GEOS-5 distribution, and another which has been recently used experimentally for its enhanced cloud microphysical capabilities; both are coupled to a cloud generator allowing arbitrary cloud overlap specification. We find that cloud overlap radiative impacts are significantly stronger for the operational cloud scheme for which a change of cloud fraction overlap from maximum-random to generalized results to global changes of SW and LW CRE of approximately 4 Watts per square meter, and zonal changes of up to approximately 10 Watts per square meter. This is because of fewer occurrences compared to the other scheme of large layer cloud fractions and of multi-layer situations with large numbers of atmospheric being simultaneously cloudy, conditions that make overlap details more important. The impact on CRE of the details of condensate distribution overlap is much weaker. Once generalized overlap is adopted, both cloud schemes are only modestly sensitive to the exact values of the overlap parameters. We also find that if one of the CRE components is overestimated and the other underestimated, both cannot be driven towards observed values by adjustments to cloud condensate heterogeneity and overlap alone.

Oreopoulos, L.↗

Temperature Oscillation in a Loop Heat Pipe with Gravity Assist

ATLAS Laser Thermal Control System (LTCS) thermal vacuum testing where the condenser-radiator was placed in a vertical position, it was found that the loop heat pipe (LHP) reservoir required much more control heater power than the analytical model had predicted. The required control heater power was also higher than the liquid subcooling entering the reservoir using the measured temperatures and the calculated mass flow rate based on steady state LHP operation. This presentation describes the investigation of the LHP behaviors under a gravity assist mode with a very cold radiator sink temperature and a large thermal mass attached to the evaporator. It is concluded that gravity caused the cold liquid to drop from the condenser-radiator to the reservoir, resulting in a rapid decrease of the reservoir temperature. When the reservoir temperature was increasing, a reverse flow occurred in the liquid line, carrying warm liquid to the condenser-radiator. Both events consumed the reservoir control heater power. The fall and rise of the reservoir temperature also caused the net heat input to the evaporator to vary due to the release and storage of the sensible heat of the thermal mass. The combination of these effects led to a persistent reservoir temperature oscillation and a repeated influx of cold liquid from the condenser. This was the root cause of the extraordinary high control heater power requirement in the LTCS TV test. Without gravity assist, such a persistent temperature oscillation will not be present.

000↗

Warm Pressurant Gas Effects on the Static Bubble Point Pressure for Cryogenic LADs

This paper presents experimental results for the liquid hydrogen and nitrogen bubble point tests using warm pressurant gases conducted at the NASA Glenn Research Center. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device (LAD). Three fine mesh screen samples (325x2300, 450x2750, 510x3600) were tested in liquid hydrogen and liquid nitrogen using cold and warm non-condensable (gaseous helium) and condensable (gaseous hydrogen or nitrogen) pressurization schemes. Gases were conditioned from 0K - 90K above the liquid temperature. Results clearly indicate degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over non-condensable pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

Warm pressurant gas↗

Pressure Profiles in a Loop Heat Pipe Under Gravity Influence

During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

0000↗

Pressure Profiles in a Loop Heat Pipe under Gravity Influence

During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity-neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

Thermal Control Systems↗

The Role of Long-Lived Greenhouse Gases as Principal LW Control Knob that Governs the Global Surface Temperature for Past and Future Climate Change

The climate system of the Earth is endowed with a moderately strong greenhouse effect that is characterized by non-condensing greenhouse gases (GHGs) that provide the core radiative forcing. Of these, the most important is atmospheric CO2. There is a strong feedback contribution to the greenhouse effect by water vapor and clouds that is unique in the solar system, exceeding the core radiative forcing due to the non-condensing GHGs by a factor of three. The significance of the non-condensing GHGs is that once they have been injected into the atmosphere, they remain there virtually indefinitely because they do not condense and precipitate from the atmosphere, their chemical removal time ranging from decades to millennia. Water vapor and clouds have only a short lifespan, with their distribution determined by the locally prevailing meteorological conditions, subject to Clausius-Clapeyron constraint. Although solar irradiance is the ultimate energy source that powers the terrestrial greenhouse effect, there has been no discernible long-term trend in solar irradiance since precise monitoring began in the late 1970s. This leaves atmospheric CO2 as the effective control knob driving the current global warming trend. Over geological time scales, volcanoes are the principal source of atmospheric CO2, and the weathering of rocks is the principal sink, with the biosphere participating as both a source and a sink. The problem at hand is that human industrial activity is causing atmospheric CO2, to increase by 2 ppm per year, whereas the interglacial rate has been 0.005 ppm per year. This is a geologically unprecedented rate to turn the CO2 climate control knob. This is causing the global warming that threatens the global environment.

Greenhouse effect↗

Evolution of the Far-Infrared Cloud at Titan's South Pole

A condensate cloud on Titan identified by its 220 cm−1 far-infrared signature continues to undergo seasonal changes at both the north and south poles. In the north, the cloud, which extends from 55 N to the pole, has been gradually decreasing in emission intensity since the beginning of the Cassini mission with a half-life of 3.8 years. The cloud in the south did not appear until 2012 but its intensity has increased rapidly, doubling every year. The shape of the cloud at the south pole is very different from that in the north. Mapping in 2013 December showed that the condensate emission was confined to a ring with a maximum at 80 S. The ring was centered 4deg from Titanʼs pole. The pattern of emission from stratospheric trace gases like nitriles and complex hydrocarbons (mapped in 2014 January) was also offset by 4deg, but had a central peak at the pole and a secondary maximum in a ring at about 70 S with a minimum at 80 S. The shape of the gas emission distribution can be explained by abundances that are high at the atmospheric pole and diminish toward the equator, combined with correspondingly increasing temperatures. We discuss possible causes for the condensate ring. The present rapid build up of the condensate cloud at the south pole is likely to transition to a gradual decline from 2015 to 2016. Key words: molecular processes - planets and satellites: atmospheres - planets and satellites: composition - planets and satellites: individual (Titan) - radiation mechanisms: thermal

Cassini↗

Ti Isotopes: Echoes of Grain-Scale Heterogenaity in the Protoplanetary Disk

Calcium-aluminum-rich inclusions (CAIs) are the oldest surviving solids to have formed in the Solar System. Their chemical and isotopic compositions provide a record of the conditions present in the protoplanetary disk where they formed and can aid our understanding of how solids formed in the solar nebula, an important step in the eventual process of planet building. The isotopic compositions of CAIs are primarily controlled by volatility. Evaporation/sublimation are well understood through both theory and experimental work to produce an enrichment in the heavy isotopes of an element, but less is understood about the effects of condensation. Mass-dependent fractionation can potentially provide a record of nebular condensation. Ti is not likely to experience evaporation due to its refractory nature, making it a useful tool for assessing the effects of condensation. We have undertaken a study of the stable isotope fractionation of Ti isotopes as a tracer of processes that predate the last evaporation events affecting CAIs. We compare the 49Ti/47Ti stable isotope ratio with excess 50Ti common in CAIs. We have collected Ti, Mg, Si, and Ca isotope data for a suite of CAIs in order to search for heterogeneity in each of these isotope systems, and for potential correlations among them. We compare our results to expectations for condensation.

Jordan, M. K.↗

Cloud Atlas: Rotational Modulations in the L/T Transition Brown Dwarf Companion HN Peg B

Time-resolved observations of brown dwarfs' rotational modulations provide powerful insights into the properties of condensate clouds in ultra-cool atmospheres. Multi-wavelength light curves reveal cloud vertical structures, condensate particle sizes, and cloud morphology, which directly constrain condensate cloud and atmospheric circulation models. We report results from Hubble Space Telescope/Wide Field Camera 3 (WFC3) near-infrared G141 taken in six consecutive orbits observations of HNPeg B, an L/T transition brown dwarf companion to a G0V type star. The best-fit sine wave to the 1.1 to 1.7 micron broadband light curve has the amplitude of and period of hour. The modulation amplitude has no detectable wavelength dependence except in the 1.4 micron water absorption band, indicating that the characteristic condensate particle sizes are large (greater than 1 micron). We detect significantly (4.4 sigma) lower modulation amplitude in the 1.4 micron water absorption band, and find that HN Peg B's spectral modulation resembles those of early T type brown dwarfs. We also describe a new empirical interpolation method to remove spectral contamination from the bright host star. This method may be applied in other high-contrast time-resolved observations with WFC3.

brown dwarf↗

Characterization of Flat-Plate Heat Pipe Functionality for Fuel Cell Application

For many exothermic systems such as proton exchange membrane (PEM) fuel cells, cooling is necessary to maintain consistent and uniform operating temperatures which are generally in the range of 60 to 80°C. A potential solution is a heat pipe employing the principle of conduction in combination with a phase change. The purpose of this study was to fully characterize the operation of a heat pipe with unique geometry designed for fuel cell heat removal at operating temperatures up to 100°C and to assess the suitability of the resulting performance for cooling system integration. Test variables consist of cold sink thermal contact conductance coefficient improving material usage, heat rejection temperature, contact pressure and area, heat pipe orientation, operational hours, and variability between units. The test results showed that heat pipe performance improves through increased condenser and heat sink contact pressure, thermal contact coating usage, greater condenser area utilization, and colder heat sink temperature. Higher initial heat pipe temperature and greater age or operation time reduce the heat pipe capabilities. Placing the condenser lower than the evaporator is the only heat pipe orientation that affects evaporator plate temperature. Condensing fluid in the lower section reduces heat transfer capacity as that orientation requires liquid water to transport by wicking against gravity.

Smith, Phillip J.↗

Oxygen Isotopic Imaging of Refractory Inclusions from the Miller Range (MIL) 090019 CO3 Chondrite: A Perovskite Perspective

Calcium-Aluminum-rich Inclusions (CAIs) in primitive meteorites are the first solids to condense in the Solar System. The oxygen isotopic compositions recorded in various mineral components of CAIs provide clues about their origins and post-formation histories, recording processes such as condensation, melting, nebular alteration, and fluidrock reactions on the parent body. MIL 090019 is similar to some rare carbonaceous chondrites such as Acfer 094, DOM 08004/6 and ALH 77303 that contain high abundances of a variety of refractory inclusions. This provides an opportunity to study the oxygen isotopic record of different types of refractory inclusions within the same meteorite. We analyzed CAIs specifically targeting primary minerals that are direct nebular condensates, such as corundum and perovskite, with the goal of gaining insights into the O isotopic composition of the nebular gas(es) from which these CAIs condensed. As MIL 090019 is a classified as CO3.1, it shows some signs of thermal metamorphism, compared to the more primitive CO3 meteorites (e.g., DOM 08004/06). A second goal of this study is to search for evidence of nebular processes in phases such as perovskite and melilite that are susceptible to parent body alteration to varying degrees. We analyzed the oxygen isotopic compositions of various CAIs from the MIL 090019 CO3 carbonaceous chondrite by ion imaging using the NanoSIMS 50L (Nano Secondary Ion Mass Spectrometer) at JSC following methods described in. An advantage of ion imaging over traditional spot analyses is that it provides spatial context to the oxygen isotopic data. This work builds on previously reported oxygen isotopic composition of two other CAIs (CAI-44 and CAI-E2) from the same meteorite thin section.

Mane, P.↗

Organic Ices in Titan's Stratosphere

Titan’s stratospheric ice clouds are by far the most complex of any observed in the solar system, with over a dozen organic vapors condensing out to form a suite of pure and co-condensed ices, typically observed at high winter polar latitudes. Once these stratospheric ices are formed, they will diffuse throughout Titan’s lower atmosphere and most will eventually precipitate to the surface, where they are expected to contribute to Titan’s regolith. Early and important contributions were first made by the InfraRed Interferometer Spectrometer (IRIS) on Voyager 1, followed by notable contributions from IRIS’ successor, the Cassini Composite InfraRed Spectrometer (CIRS), and to a lesser extent, from Cassini’s Visible and Infrared Mapping Spectrometer (VIMS) and the Imaging Science Subsystem (ISS) instruments. All three remote sensing instruments made new ice cloud discoveries, combined with monitoring the seasonal behaviors and time evolution throughout Cassini’s 13-year mission tenure. A significant advance by CIRS was the realization that co-condensing chemical compounds can account for many of the CIRS-observed stratospheric ice cloud spectral features, especially for some that were previously puzzling, even though some of the observed spectral features are still not well understood. Relevant laboratory transmission spectroscopy efforts began just after the Voyager encounters, and have accelerated in the last few years due to new experimental efforts aimed at simulating co-condensed ices in Titan’s stratosphere. This review details the current state of knowledge regarding the organic ice clouds in Titan’s stratosphere, with perspectives from both observational and experimental standpoints.

Astronomy↗

Organic Ices in Titan's Stratosphere

Titan’s stratospheric ice clouds are by far the most complex of any observed in the solar system, with over a dozen organic vapors condensing out to form a suite of pure and co-condensed ices, typically observed at high winter polar latitudes. Once these stratospheric ices are formed, they will diffuse throughout Titan’s lower atmosphere and most will eventually precipitate to the surface, where they are expected to contribute to Titan’s regolith. Early and important contributions were first made by the InfraRed Interferometer Spectrometer (IRIS) on Voyager 1, followed by notable contributions from IRIS’ successor, the Cassini Composite InfraRed Spectrometer (CIRS), and to a lesser extent, from Cassini’s Visible and Infrared Mapping Spectrometer (VIMS) and the Imaging Science Subsystem (ISS) instruments. All three remote sensing instruments made new ice cloud discoveries, combined with monitoring the seasonal behaviors and time evolution throughout Cassini’s 13-year mission tenure. A significant advance by CIRS was the realization that co-condensing chemical compounds can account for many of the CIRS-observed stratospheric ice cloud spectral features, especially for some that were previously puzzling, even though some of the observed spectral features are still not well understood. Relevant laboratory transmission spectroscopy efforts began just after the Voyager encounters, and have accelerated in the last few years due to new experimental efforts aimed at simulating co-condensed ices in Titan’s stratosphere. This review details the current state of knowledge regarding the organic ice clouds in Titan’s stratosphere, with perspectives from both observational and experimental standpoints.

C. M. Anderson↗

Organic Ices in Titan’s Stratosphere

Titan’s stratospheric ice clouds are by far the most complex of any observed in the solar system, with over a dozen organic vapors condensing out to form a suite of pure and co-condensed ices, typically observed at high winter polar latitudes. Once these stratospheric ices are formed, they will diffuse throughout Titan’s lower atmosphere and most will eventually precipitate to the surface, where they are expected to contribute to Titan’s regolith. Early and important contributions were first made by the InfraRed Interferometer Spectrometer (IRIS) on Voyager 1, followed by notable contributions from IRIS’ successor, the Cassini Composite InfraRed Spectrometer (CIRS), and to a lesser extent, from Cassini’s Visible and Infrared Mapping Spectrometer (VIMS) and the Imaging Science Subsystem (ISS) instruments. All three remote sensing instruments made new ice cloud discoveries, combined with monitoring the seasonal behaviors and time evolution throughout Cassini’s 13-year mission tenure. A significant advance by CIRS was the realization that co-condensing chemical compounds can account for many of the CIRS-observed stratospheric ice cloud spectral features, especially for some that were previously puzzling, even though some of the observed spectral features are still not well understood. Relevant laboratory transmission spectroscopy efforts began just after the Voyager encounters, and have accelerated in the last few years due to new experimental efforts aimed at simulating co-condensed ices in Titan’s stratosphere. This review details the current state of knowledge regarding the organic ice clouds in Titan’s stratosphere, with perspectives from both an observational and experimental standpoint.

Ices↗