Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BODY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Continuum spectroscopy with a {sup 10}C beam: Cluster structure and three-body decay

Resonance-decay spectroscopy is used to study particle-unbound excited states produced in interactions of E/A=10.7 MeV {sup 10}C on Be and C targets. After inelastic scattering, structures associated with excited states in {sup 10}C were observed at 5.22, 5.29, 6.55, 6.56, 6.57, and 8.4 MeV which decay into the 2p+2{alpha} final state. This final state is created via a number of different decay paths, which include prompt and sequential two-proton decay to the ground state of {sup 8}Be, {alpha} decay to {sup 6}Be{sub g.s.}, and proton decay to the 2.345-MeV state of {sup 9}B. For the sequential two-proton decay states (5.22 and 6.55 MeV), angular correlations between the first two decay axes indicate that the spin of these states are nonzero. For the prompt two-proton decay of the 5.29-MeV state, the three-body correlations between the two protons and the core are intermediate between those measured for ground-state {sup 6}Be and {sup 45}Fe decays. The 6.55- and 6.57-MeV structures are most probably associated with the same level, which has a 14% two-proton decay branch with a strong ''diproton'' character and a 86% sequential two-proton decay branch. Correlations between the fragments following the three-body decay of the 2.345-MeV state of {sup 9}B can be approximately described by sequential {alpha} decay to the {sup 5}Li intermediate state. The 8.06- and 9.61-MeV {sup 10}B states that decay into the d+{sup 6}Li{sub 2.186} channel are confirmed. Evidence for cluster structure in {sup 13}N is obtained from a number of excited states that decay into the p+3{alpha} exit channel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-body decay of {sup 6}Be

Three-body correlations for the ground-state decay of the lightest two-proton emitter {sup 6}Be are studied both theoretically and experimentally. Theoretical studies are performed in a three-body hyperspherical-harmonics cluster model. In the experimental studies, the ground state of {sup 6}Be was formed following the {alpha} decay of a {sup 10}C beam inelastically excited through interactions with Be and C targets. Excellent agreement between theory and experiment is obtained demonstrating the existence of complicated correlation patterns that can elucidate the structure of {sup 6}Be and, possibly, of the A=6 isobars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the differential cross section for the two-body photodisintegration of {sup 3}He at {theta}{sup LAB}=90 deg. using tagged photons in the energy range 14-31 MeV

The two-body photodisintegration of {sup 3}He has been investigated using tagged photons with energies from 14-31 MeV at MAX-lab in Lund, Sweden. The two-body breakup channel was unambiguously identified by the (nonsimultaneous) detection of both protons and deuterons. This approach was made feasible by the overdetermined kinematic situation afforded by the tagged-photon technique. Proton- and deuteron-energy spectra were measured using four silicon surface-barrier detector telescopes located at a laboratory angle of 90 deg. with respect to the incident photon-beam direction. Average statistical and systematic uncertainties of 5.7% and 6.6% in the differential cross section were obtained for 11 photon-energy bins with an average width of 1.2 MeV. The results are compared to previous experimental data measured at comparable photon energies as well as to the results of two recent Faddeev calculations which employ realistic potential models and take into account three-nucleon forces and final-state interactions. Both the accuracy and precision of the present data are improved over those obtained in the previous measurements. The data are in good agreement with most of the previous results, and favor the inclusion of three-nucleon forces in the calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-body continuum states in a microscopic cluster model

We propose a microscopic approach to three-body continuum states in the hyperspherical formalism. The A-nucleon wave functions are defined in the generator coordinate method, based on a three-cluster approximation of the system. We develop a semianalytical treatment of the matrix elements, limited to s clusters. This allows a fast calculation, as well as a direct interpretation of the wave functions, in terms of nucleon exchanges. We apply the method to the {alpha}+n+n three-body phase shifts and confirm the existence of broad structures in the 0{sup +} and 1{sup -} partial waves at low energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of repulsive and attractive three-body forces on nucleus-nucleus elastic scattering

The effect of the three-body force (TBF) is studied in nucleus-nucleus elastic scattering on the basis of Brueckner theory for nucleon-nucleon (NN) effective interaction (complex G matrix) in the nuclear matter. A new G matrix called CEG07 proposed recently by the present authors includes the TBF effect and reproduces a realistic saturation curve in the nuclear matter, and it is shown to well reproduce proton-nucleus elastic scattering. The microscopic optical potential for the nucleus-nucleus system is obtained by folding the G matrix with nucleon density distributions in colliding nuclei. We first analyze in detail the {sup 16}O+{sup 16}O elastic scattering at E/A=70 MeV. The observed cross sections are nicely reproduced up to the most backward scattering angles only when the TBF effect is included. The use of the frozen-density approximation (FDA) is essentially important to properly estimate the effect of the TBF in nucleus-nucleus scattering. Other prescriptions for defining the local density have also been tested, but only the FDA prescription gives a proper description of the experimental cross sections as well as the effect of the TBF. The effects of the three-body attraction and the {omega}-rearrangement term are also analyzed. The CEG07 interaction is compared with CDM3Y6, which is a reliable and successful effective density-dependent NN interaction used in the double-folding model. The CEG07 G matrix is also tested in the elastic scattering of {sup 16}O by the {sup 12}C, {sup 28}Si, and {sup 40}Ca targets at E/A=93.9 MeV, and in the elastic scattering of {sup 12}C by the {sup 12}C target at E/A=135 MeV with great success. The decisive effect of the TBF is clearly seen also in those systems. Finally, we have tested CEG07a, CEG07b, and CEG07c for the {sup 16}O+{sup 16}O system at various energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multinucleon Ejection Model for Two Body Current Neutrino Interactions

A model is proposed to describe nucleons ejected from a nucleus as a result of two-body-current neutrino interactions. The model can be easily implemented in Monte Carlo neutrino event generators. Various possibilities to measure the two-body-current contribution are discussed. The model can help identify genuine charge current quasielastic events and allow for a better determination of the systematic error on neutrino energy reconstruction in neutrino oscillation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Li 6 in a three-body model with realistic Forces: Separable versus nonseparable approach

Background: Deuteron induced reactions are widely used to probe nuclear structure and astrophysical information. Those (d, p) reactions may be viewed as three-body reactions and described with Faddeev techniques. Purpose: Faddeev equations in momentum space have a long tradition of utilizing separable interactions in order to arrive at sets of coupled integral equations in one variable. However, it needs to be demonstrated that their solution based on separable interactions agrees exactly with solutions based on nonseparable forces. Methods: Momentum space Faddeev equations are solved with nonseparable and separable forces as coupled integral equations. Results: The ground state of 6 Li is calculated via momentum space Faddeev equations using the CD-Bonn neutron-proton force and a Woods-Saxon type neutron(proton)- 4 He force. For the latter the Pauli-forbidden S -wave bound state is projected out. This result is compared to a calculation in which the interactions in the two-body subsystems are represented by separable interactions derived in the Ernst-Shakin-Thaler (EST) framework. Conclusions: We find that calculations based on the separable representation of the interactions and the original interactions give results that agree to four significant figures for the binding energy, provided that energy and momentum support points of the EST expansion are chosen independently. The momentum distributions computed in both approaches also fully agree with each other.

6 ≤ A ≤ 19↗

Bound states in the B -matrix formalism for the three-body scattering

In this work, we consider a model of relativistic three-body scattering with a bound state in the two-body subchannel. We show that the naiïve K-matrix type parametrization, here referred to as the B-matrix, has nonphysical singularities near the physical region. We show how to eliminate such singularities by using dispersion relations and also show how to reproduce unitarity relations by taking into account all relevant open channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-body decays of sleptons with general flavor violation and left-right mixing

We determine the widths of three-body decays of sleptons, l-tilde{sup -}{yields}l-tilde{sup {+-}}l{sup -}l{sup {+-}}, l-tilde{sup -}{nu}{nu}, l-tilde{sup -}qq, in the presence of arbitrary slepton flavor violation and left-right mixing. These decays are important in scenarios in which the lightest supersymmetric particle is the gravitino, a generic possibility in models with gauge- and gravity-mediated supersymmetry breaking. Three-body decays have been discussed previously, assuming flavor conservation and left-right mixing in only the stau sector. Flavor violation and general left-right mixing open up many new decay channels, which provide new avenues for precision mass measurements and may play an essential role in solving the standard model flavor problem. We present results for toy models with two-generation mixing, and discuss the implementation of these results in spice, a program that simplifies collider event simulations of flavor-violating supersymmetric models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dressing the post-Newtonian two-body problem and classical effective field theory

We apply a dressed perturbation theory to better organize and economize the computation of high orders of the 2-body effective action of an inspiralling post-Newtonian (PN) gravitating binary. We use the effective field theory approach with the nonrelativistic field decomposition (NRG fields). For that purpose we develop quite generally the dressing theory of a nonlinear classical field theory coupled to pointlike sources. We introduce dressed charges and propagators, but unlike the quantum theory there are no dressed bulk vertices. The dressed quantities are found to obey recursive integral equations which succinctly encode parts of the diagrammatic expansion, and are the classical version of the Schwinger-Dyson equations. Actually, the classical equations are somewhat stronger since they involve only finitely many quantities, unlike the quantum theory. Classical diagrams are shown to factorize exactly when they contain nonlinear worldline vertices, and we classify all the possible topologies of irreducible diagrams for low loop numbers. We apply the dressing program to our post-Newtonian case of interest. The dressed charges consist of the dressed energy-momentum tensor after a nonrelativistic decomposition, and we compute all dressed charges (in the harmonic gauge) appearing up to 2PN in the 2-body effective action (and more). We determine the irreducible skeleton diagrams up to 3PN and we employ the dressed charges to compute several terms beyond 2PN.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Many-Body Treatment of the Collisional Frequency Shift in Fermionic Atoms

Recent experiments have measured collisional frequency shifts in polarized fermionic alkaline-earth atoms using {sup 1}S{sub 0}-{sup 3}P{sub 0} Rabi spectroscopy. Here, we provide a first-principles nonequilibrium theoretical description of the interaction frequency shifts starting from the microscopic many-body Hamiltonian. Our formalism describes the dependence of the frequency shift on excitation inhomogeneity, interactions, temperature, and many-body dynamics, provides a fundamental understanding of the effects of the measurement process, and explains the observed density shift data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Many-Body Localization in the Presence of a Central Qudit

We consider a many-body localized system coupled globally to a central d -level system. Under an appropriate scaling of d and L, we find evidence that the localized phase survives. We argue for two possible thermalizing phases, depending on whether the qudit becomes fully ergodic. This system provides one of the first examples of many-body localization in the presence of long-range (nonconfining) interactions.

1-dimensional spin chains↗

A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lung dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-260: Pediatric Total Body Irradiation Calculations and In-Vivo Dosimetry Using Diodes and OSLD's

Purpose: To verify that a photon total body irradiation (TBI) calculation method scales properly from adult to pediatric dimensions and to determine TBI in-vivo dosimetry correction factors for diodes and optically stimulated luminescent dosimeters (OSLD's). Methods: TBI technique used is 400 SAD 18 MV opposed laterals with beam spoiler. Water bags are used to supplement narrower lateral dimensions for patient treatments. To verify that dose calculations scale properly with decreasing dimensions, CAX doses were measured and compared to calculations for different rectangular phantom geometries: (L=length(cm), H=height(cm), d=depth(cm)): L(30)xH(30) (d=3-25), L(30)xH(12)(d=2–20), L(13)xH(13) (d=5–13), L(30)x(H=10–40) d=15, L(30–150) x H(10) (d=15). In infant geometry, measured off axis “leg” dose (L(30)xH(2.5–10.6), d=7)) was compared to CAX (“body” L(30)xH(10)(d=7) adjacent to “leg”). Entrance and exit doses were measured with surface diodes, diodes with buildup, OSLD's, as well as ion chambers for comparison. Correction factors ((ion chamber CAX dose)/(in vivo dose)) were calculated for surface diodes, diodes with buildup, OSLD's, and ion chamber. Results: All rectangular phantom measurements agree with calculated within 2.5%. For L(30)xH(30), L(30)xH(12), L(13)xH(13), L(30)x(H=10–40) and L(30–80)xH(10) agreement was within 1%. For the infant geometry, the ratio of leg dose to CAX varies from 0.956 (h=2.5) to 0.995 (h=10.6). The range of in-vivo dosimetry entrance+exit to CAX dose correction factors varied by dosimeter (diode: 0.883–1.015, surface diode: 1.008–1.214, ion chamber: 0.924–1.084, OSLD: 0.920–1.106). Conclusion: TBI calculations scaled properly to pediatric dimensions. In-vivo dosimetry with various detectors demonstrated similar trends with different magnitudes. OSLD measurements agreed well with ion chamber measurements.

60 APPLIED LIFE SCIENCES↗

SU-C-213-04: Application of Depth Sensing and 3D-Printing Technique for Total Body Irradiation (TBI) Patient Measurement and Treatment Planning

Purpose: To develop and validate an innovative method of using depth sensing cameras and 3D printing techniques for Total Body Irradiation (TBI) treatment planning and compensator fabrication. Methods: A tablet with motion tracking cameras and integrated depth sensing was used to scan a RANDOTM phantom arranged in a TBI treatment booth to detect and store the 3D surface in a point cloud (PC) format. The accuracy of the detected surface was evaluated by comparison to extracted measurements from CT scan images. The thickness, source to surface distance and off-axis distance of the phantom at different body section was measured for TBI treatment planning. A 2D map containing a detailed compensator design was calculated to achieve uniform dose distribution throughout the phantom. The compensator was fabricated using a 3D printer, silicone molding and tungsten powder. In vivo dosimetry measurements were performed using optically stimulated luminescent detectors (OSLDs). Results: The whole scan of the anthropomorphic phantom took approximately 30 seconds. The mean error for thickness measurements at each section of phantom compare to CT was 0.44 ± 0.268 cm. These errors resulted in approximately 2% dose error calculation and 0.4 mm tungsten thickness deviation for the compensator design. The accuracy of 3D compensator printing was within 0.2 mm. In vivo measurements for an end-to-end test showed the overall dose difference was within 3%. Conclusion: Motion cameras and depth sensing techniques proved to be an accurate and efficient tool for TBI patient measurement and treatment planning. 3D printing technique improved the efficiency and accuracy of the compensator production and ensured a more accurate treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-92: Achieving Desirable Lung Doses in Total Body Irradiation Based On in Vivo Dosimetry and Custom Tissue Compensation

Purpose: To achieve desirable lung doses in total body irradiation (TBI) based on in vivo dosimetry and custom tissue compensation. Methods: The 15 MV photon beam of a Varian TrueBeam STx linac was used for TBI. Patients were positioned in the lateral decubitus position for AP/PA treatment delivery. Dose was calculated using the midpoint of the separation distance across the patient’s umbilicus. Patients received 200 cGy twice daily for 3 days. The dose rate at the patient’s midplane was approximately 10 cGy/min. Cerrobend blocks with a 5-HVL thickness were used for the primary lung shielding. A custom styrofoam holder for rice-flour filled bags was created based on the lung block cutouts. This was used to provide further lung shielding based on in vivo dose measurements. Lucite plates and rice-flour bags were placed in the head, neck, chest, and lower extremity regions during the treatment to compensate for the beam off-axis output variations. Two patients were included in the study. Patients 1 and 2 received a craniospinal treatment (1080 cGy) and a mediastinum treatment (2520 cGy), respectively, before the TBI. During the TBI nanoDot dosimeters were placed on the patient skin in the forehead, neck, umbilicus, and lung regions for dose monitoring. The doses were readout immediately after the treatment. Based on the readings, fine tuning of the thickness of the rice-flour filled bags was exploited to achieve the desirable lung doses. Results: For both patients the mean lung doses, which took into consideration all treatments, were controlled within 900 +/−10% cGy, as desired. Doses to the forehead, neck, and umbilicus were achieved within +/−10% of the prescribed dose (1200 cGy). Conclusion: A reliable and robust method was developed to achieve desirable lung doses and uniform body dose in TBI based on in vivo dosimetry and custom tissue compensator.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speed of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.

60 APPLIED LIFE SCIENCES↗

Helium trimer calculations with a public quantum three-body code

We present an illustration of using a quantumthree-body code being prepared for public release. The code is based on iterative solving of the three-dimensional Faddeev equations. The code is easy to use and allows users to perform highly-accurate calculations of quantum three-body systems. The previously known results for He{sub 3} ground state are well reproduced by the code.

74 ATOMIC AND MOLECULAR PHYSICS↗