Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Definition of the Spatial Resolution of X-Ray Microanalysis in Thin Foils

The spatial resolution of X-ray microanalysis in thin foils is defined in terms of the incident electron beam diameter and the average beam broadening. The beam diameter is defined as the full width tenth maximum of a Gaussian intensity distribution. The spatial resolution is calculated by a convolution of the beam diameter and the average beam broadening. This definition of the spatial resolution can be related simply to experimental measurements of composition profiles across interphase interfaces. Monte Carlo calculations using a high-speed parallel supercomputer show good agreement with this definition of the spatial resolution and calculations based on this definition. The agreement is good over a range of specimen thicknesses and atomic number, but is poor when excessive beam tailing distorts the assumed Gaussian electron intensity distributions. Beam tailing occurs in low-Z materials because of fast secondary electrons and in high-Z materials because of plural scattering.

Williams, D. B.↗

Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer

Purpose: To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans. Methods: Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°. Subsequently, the clinical lung SBRT plans for the 26 consecutive patients were transferred from the iPlan (ver. 4.1; BrainLab AG) to the Eclipse treatment planning systems (ver. 11.0.3; Varian Medical Systems, Palo Alto, CA). The doses were then recalculated with AXB and AAA while maintaining the XVMC-calculated monitor units and beam arrangement. Then the dose-volumetric data obtained using the three different radiation dose calculation algorithms were compared. Results: The results from AXB and XVMC agreed with measurements within ±3.0% for the lung-equivalent phantom with a 6 × 6 cm{sup 2} field size, whereas AAA values were higher than measurements in the heterogeneous zone and near the boundary, with the greatest difference being 4.1%. AXB and XVMC agreed well with measurements in terms of the profile shape at the boundary of the heterogeneous zone. For the lung SBRT plans, AXB yielded lower values than XVMC in terms of the maximum doses of ITV and PTV; however, the differences were within ±3.0%. In addition to the dose-volumetric data, the dose distribution analysis showed that AXB yielded dose distribution calculations that were closer to those with XVMC than did AAA. Means ± standard deviation of the computation time was 221.6 ± 53.1 s (range, 124–358 s), 66.1 ± 16.0 s (range, 42–94 s), and 6.7 ± 1.1 s (range, 5–9 s) for XVMC, AXB, and AAA, respectively. Conclusions: In the phantom evaluations, AXB and XVMC agreed better with measurements than did AAA. Calculations differed in the density-changing zones (substance boundaries) between AXB/XVMC and AAA. In the lung SBRT cases, a comparative analysis of dose-volumetric data and dose distributions with XVMC demonstrated that the AXB provided better agreement with XVMC than AAA. The computation time of AXB was faster than that of XVMC; therefore, AXB has better balance in terms of the dosimetric performance and computation speed for clinical use than XVMC.

60 APPLIED LIFE SCIENCES↗

SU-E-T-800: Verification of Acurose XB Dose Calculation Algorithm at Air Cavity-Tissue Interface Using Film Measurement for Small Fields of 6-MV Flattening Filter-Free Beams

Purpose: To verify the dose accuracy of Acuros XB (AXB) dose calculation algorithm at air-tissue interface using inhomogeneous phantom for 6-MV flattening filter-free (FFF) beams. Methods: An inhomogeneous phantom included air cavity was manufactured for verifying dose accuracy at the air-tissue interface. The phantom was composed with 1 and 3 cm thickness of air cavity. To evaluate the central axis doses (CAD) and dose profiles of the interface, the dose calculations were performed for 3 × 3 and 4 × 4 cm{sup 2} fields of 6 MV FFF beams with AAA and AXB in Eclipse treatment plainning system. Measurements in this region were performed with Gafchromic film. The root mean square errors (RMSE) were analyzed with calculated and measured dose profile. Dose profiles were divided into inner-dose profile (>80%) and penumbra (20% to 80%) region for evaluating RMSE. To quantify the distribution difference, gamma evaluation was used and determined the agreement with 3%/3mm criteria. Results: The percentage differences (%Diffs) between measured and calculated CAD in the interface, AXB shows more agreement than AAA. The %Diffs were increased with increasing the thickness of air cavity size and it is similar for both algorithms. In RMSEs of inner-profile, AXB was more accurate than AAA. The difference was up to 6 times due to overestimation by AAA. RMSEs of penumbra appeared to high difference for increasing the measurement depth. Gamma agreement also presented that the passing rates decreased in penumbra. Conclusion: This study demonstrated that the dose calculation with AXB shows more accurate than with AAA for the air-tissue interface. The 2D dose distributions with AXB for both inner-profile and penumbra showed better agreement than with AAA relative to variation of the measurement depths and air cavity sizes.

60 APPLIED LIFE SCIENCES↗

A Monte Carlo investigation of low-Z target image quality generated in a linear accelerator using Varian's VirtuaLinac

Purpose: The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. Methods: VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code, was used to model the Linac treatment head components. Particles were propagated through the lower portion of the treatment head using BEAMnrc. Dose distributions and spectral distributions were calculated using DOSXYZnrc and BEAMdp, respectively. For validation, 6 MV flattened and flattening filter free (FFF) photon beams were generated and compared to measurement for square fields, 10 and 40 cm wide and at d{sub max} for diagonal profiles. Two low-Z targets were investigated: a 2.35 MeV carbon target and the proposed 2.50 MeV commercial imaging target for the TrueBeam platform. A 2.35 MeV carbon target was also simulated in a 2100EX Clinac using BEAMnrc. Contrast simulations were made by scoring the dose in the phosphor layer of an IDU20 aSi detector after propagating through a 4 or 20 cm thick phantom composed of water and ICRP bone. Results: Measured and modeled depth dose curves for 6 MV flattened and FFF beams agree within 1% for 98.3% of points at depths greater than 0.85 cm. Ninety three percent or greater of points analyzed for the diagonal profiles had a gamma value less than one for the criteria of 1.5 mm and 1.5%. The two low-Z target photon spectra produced in TrueBeam are harder than that from the carbon target in the Clinac. Percent dose at depth 10 cm is greater by 3.6% and 8.9%; the fraction of photons in the diagnostic energy range (25–150 keV) is lower by 10% and 28%; and contrasts are lower by factors of 1.1 and 1.4 (4 cm thick phantom) and 1.03 and 1.4 (20 cm thick phantom), for the TrueBeam 2.35 MV/carbon and commercial imaging beams, respectively. Conclusions: VirtuaLinac is a promising new tool for Monte Carlo modeling of novel target designs. A significant spectral difference is observed between the low-Z target beam on the Clinac platform and the proposed imaging beam line on TrueBeam, with the former providing greater diagnostic energy content.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced method to reconstruct mode shapes of continuous scanning measurements using the Hilbert Huang transform and the modal analysis method

Generally, it is time consuming to experimentally identify the operating deflection shape or mode shape of a structure. To overcome this problem, the Hilbert Huang transform (HHT) technique has been recently proposed. This technique is used to extract the mode shape from measurements that continuously measure the vibration of a region of interest within a structure using a non-contact laser sensor. In previous research regarding the HHT, two technical processes were needed to obtain the mode shape for each mode. The purpose of this study is to improve and complement our previous research, and for this purpose, a modal analysis approach is adapted without using the two technical processes to obtain an accurate un-damped impulse response of each mode for continuous scanning measurements. In addition, frequency response functions for each type of beam are derived, making it possible to make continuously scanned measurements along a straight profile. In this paper, the technical limitations and drawbacks of the damping compensation technique used in previous research are identified. In addition, the separation of resonant frequency (the Doppler effect) that occurs in continuous scanning measurements and the separation of damping phenomenon are also observed. The proposed method is quantitatively verified by comparing it with the results obtained from a conventional approach to estimate the mode shape with an impulse response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of a positron beam-driven hollow channel plasma wakefield accelerator

Plasma wakefield accelerators have been used to accelerate electron and positron particle beams with gradients that are orders of magnitude larger than those achieved in conventional accelerators. In addition to being accelerated by the plasma wakefield, the beam particles also experience strong transverse forces that may disrupt the beam quality. Hollow plasma channels have been proposed as a technique for generating accelerating fields without transverse forces. In this study, we demonstrate a method for creating an extended hollow plasma channel and measure the wakefields created by an ultrarelativistic positron beam as it propagates through the channel. The plasma channel is created by directing a high-intensity laser pulse with a spatially modulated profile into lithium vapour, which results in an annular region of ionization. A peak decelerating field of 230 MeV m -1 is inferred from changes in the beam energy spectrum, in good agreement with theory and particle-in-cell simulations.

43 PARTICLE ACCELERATORS↗

Raman-shifting an ArF excimer laser to generate new lines for obtaining optical diagnostic based information in flow fields

The application of tunable excimer lasers in combustion and flow diagnostics is almost routine nowadays. The properties of this laser system that enable density and temperature measurements in supersonic and hypersonic flow fields to be conducted are its high power, high repetition rate, and high spectral brightness. The limitation imposed by this system on these measurements is the paucity of lines in the wavelength region, the vacuum-ultraviolet, where species of interest, such as OH, N2, O2, H2, H2O, CO, NO, etc., are susceptible to electronic excitation to high-lying states. To circumvent this problem one normally resorts to nonlinear optical techniques such as frequency conversion via stimulated Raman scattering (SRS), more commonly known as Raman shifting or Raman mixing, to extend these nonintrusive and nonperturbing techniques to the shorter wavelengths in the VUV region and, for that matter, to longer wavelengths in the infrared region, if the need arises. The theoretical basis of SRS and its application are well documented in the literature. In essence, the Raman shift is a consequence of the inelastic scattering of the incident radiation by the sample. Most of the scattered radiation from the molecules of the sample is unchanged in frequency. However, a small fraction of the incident radiation is changed in frequency. This shift is a result of the fact that some of the incident photons on colliding with the molecules of the sample give up some of their energy and emerge with a lower energy resulting in the lower-frequency Stokes radiation. Other incident photons may increase their energy by colliding with the vibrationally excited molecules of the medium and emerge as higher-frequency antistokes radiation. The generation of the latter is the main objective of this project. The process, however, depends on several factors, including the beam quality of the pump laser, the cross-section of the gaseous medium, the gas pressure, and the ambient temperature of the gas near the focal region. Furthermore, since the Raman shifting process is polarization sensitive, it is necessary to have all of the laser energy in a single polarization. These factors were taken into consideration in the execution of the project. The implementation of the Raman shift was accomplished by focusing the 193 nm output of an ArF excimer laser (Lamda-Physik LPX 150) into a 1-meter long high pressure recirculating Raman cell filled with H2 gas. The laser system was modified in order to improve the mode quality of the pump beam to enhance the Raman shifting. To accomplish this feat, a prism beam expander and grating on the oscillator discharge provided wavelength tuning over the excimer gain profile. Furthermore, a triple-pass configuration, as opposed to unstable resonator optics, was employed in the operation of the amplifier cavity so that when the oscillator output radiation, focused by a 51-cm focal length fused silica lens through a 50 micron pinhole (serving as a spatial filter) and recollimated with a 25-cm focal length lens, was fed into the amplifier, it was injection locked, thereby providing tunable radiation with relatively low divergence. The forward scattered radiation emanating from the impingement of the modified pump beam on the Raman cell was detected using an energy meter after the latter had been separated from it using a dispersing prism.

Koker, Edmond B.↗

Poster — Thur Eve — 15: Improvements in the stability of the tomotherapy imaging beam

Use of helical TomoTherapy based MVCT imaging for adaptive planning requires the image values (HU) to remain stable over the course of treatment. In the past, the image value stability was suboptimal, which required frequent change to the image value to density calibration curve to avoid dose errors on the order of 2–4%. The stability of the image values at our center was recently improved by stabilizing the dose rate of the machine (dose control servo) and performing daily MVCT calibration corrections. In this work, we quantify the stability of the image values over treatment time by comparing patient treatment image density derived using MVCT and KVCT. The analysis includes 1) MVCT - KVCT density difference histogram, 2) MVCT vs KVCT density spectrum, 3) multiple average profile density comparison and 4) density difference in homogeneous locations. Over two months, the imaging beam stability was compromised several times due to a combination of target wobbling, spectral calibration, target change and magnetron issues. The stability of the image values were analyzed over the same period. Results show that the impact on the patient dose calculation is 0.7% +− 0.6%.

60 APPLIED LIFE SCIENCES↗

Revealing the beneficial role of K in grain interiors, grain boundaries, and at the buffer interface for highly efficient CuInSe 2 solar cells

K incorporation within grain boundaries, grain interiors, and interfaces has been studied within CuInSe 2 solar cells to better understand the beneficial or detrimental role of K distribution among these regions in chalcopyrite–based solar cells. Solar cells have been fabricated with intentional K introduction into specific regions of the device including the CuInSe 2 /CdS interface (CuInSe 2 /KInSe 2 /CdS) and the grain interiors (Cu 0.93 K 0.07 InSe 2 /CdS). A control CuInSe 2 /CdS device was also studied to separate effects of K originating from the soda–lime glass substrate from those of intentionally introduced K. The experiment was designed to understand K effects in Cu(In,Ga)Se 2 solar cells while mitigating complications from multiple elements in the 3 + site. The distribution of all elements within these samples has been directly observed with sub–nm resolution via atom probe tomography. In addition, electron beam–induced current measurements have been performed to correlate the atom probe tomography compositional profiles to the nanoscale carrier collection properties. The experiments show that a large decrease in the Cu/In ratio at the CdS interface can be achieved by forming KInSe 2 at the absorber surface, which drastically improves the device efficiency. The results presented here show a direct link between K concentration, Cu depletion, and In accumulation, such that the Cu/In ratio significantly reduces with K incorporation. In conclusion, the findings help clarify the mechanism behind K–induced efficiency enhancement.

14 SOLAR ENERGY↗

Tilted lidar profiling: Development and testing of a novel scanning strategy for inhomogeneous flows

The most common profiling techniques for the atmospheric boundary layer based on a monostatic Doppler wind lidar rely on the assumption of horizontal homogeneity of the flow. This assumption breaks down in the presence of either natural or human-made obstructions that can generate significant flow distortions. The need to deploy ground-based lidars near operating wind turbines for the American WAKE experimeNt (AWAKEN) spurred a search for novel profiling techniques that could avoid the influence of the flow modifications caused by the wind farms. With this goal in mind, two well-established profiling scanning strategies have been retrofitted to scan in a tilted fashion and steer the beams away from the more severely inhomogeneous region of the flow. Results from a field test at the National Renewable Energy Laboratory's 135-m meteorological tower show that the accuracy of the horizontal mean flow reconstruction is insensitive to the tilt of the scan, although higher-order wind statistics are severely deteriorated at extreme tilts mainly due to geometrical error amplification. A numerical study of the AWAKEN domain based on the Weather Research and Forecasting Model and large-eddy simulation are also conducted to test the effectiveness of tilted profiling. It is shown that a threefold reduction of the error on inflow mean wind speed can be achieved for a lidar placed at the base of the turbine using tilted profiling.

17 WIND ENERGY↗

Anomalous fast ion losses at high β on the tokamak fusion test reactor

This paper describes experiments carried out on the Tokamak Fusion Test Reactor (TFTR) [R. J. Hawryluk et al., Plasma Phys. Controlled Fusion 33, 1509 (1991)] to investigate the dependence of β-limiting disruption characteristics on toroidal field strength. The hard disruptions found at the β-limit in high field plasmas were not found at low field, even for β's 50% higher than the empirical β-limit of β{sub n} ≈ 2 at high field. Comparisons of experimentally measured β's to TRANSP simulations suggest anomalous loss of up to half of the beam fast ions in the highest β, low field shots. The anomalous transport responsible for the fast ion losses may at the same time broaden the pressure profile. Toroidal Alfvén eigenmodes, fishbone instabilities, and Geodesic Acoustic Modes are investigated as possible causes of the enhanced losses. Here, we present the first observations of high frequency fishbones [F. Zonca et al., Nucl. Fusion 49, 085009 (2009)] on TFTR. The interpretation of Axi-symmetric Beam-driven Modes as Geodesic Acoustic Modes and their possible correlation with transport barrier formation are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ignition when heating the central part of an inertial confinement fusion target by an ion beam

We investigate the ignition and burning of a precompressed laser fusion target when it is rapidly heated by an ion beam with the formation of a temperature peak in the central part of the target. We present the results of our comprehensive numerical simulations of the problem that include the following components: (1) the target compression under the action of a profiled laser pulse, (2) the heating of the compressed target with spatially nonuniform density and temperature distributions by a beam of high-energy ions, and (3) the burning of the target with the initial spatial density distribution formed at the instant of maximum target compression and the initial spatial temperature distribution formed as a result of the compressed-target heating by an ion beam. The dependences of the threshold energies of the igniting ion beam and the thermonuclear gain on the width of the Gaussian beam ion energy spectrum have been established. The peculiarities of fast ignition by an ion beam related to the spatial distribution of parameters for the target precompressed by a laser pulse are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of laser interaction with ablative plasma and hydrodynamic behavior of laser supported plasma

When an intense laser beam irradiates on a solid target, ambient air ionizes and becomes plasma, while part of the target rises in temperature, melts, vaporizes, ionizes, and yet becomes plasma. A general Godunov finite difference scheme WENO (Weighted Essentially Non-Oscillatory Scheme) with fifth-order accuracy is used to simulate 2-dimensional axis symmetrical laser-supported plasma flow field in the process of laser ablation. The model of the calculation of ionization degree of plasma and the interaction between laser beam and plasma are considered in the simulation. The numerical simulations obtain the profiles of temperature, density, and velocity at different times which show the evolvement of the ablative plasma. The simulated results show that the laser energy is strongly absorbed by plasma on target surface and that the velocity of laser supported detonation (LSD) wave is half of the ideal LSD value derived from Chapman-Jouguet detonation theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of a tapered capillary plasma waveguide for laser wakefield acceleration

We developed a gas-filled capillary with a tapered density for laser wakefield acceleration, of which the tapering was realized by employing gas feed-lines with different cross-sections. Plasma diagnostics show that the capillary plasma has a significant longitudinal density tapering and a transverse parabolic profile. By using the tapered capillary plasma, high transmission (over 90%) of laser beams, meaning good optical guiding, was observed. These results demonstrate the potential of the tapered plasma source for high-energy laser wakefield acceleration, where the dephasing problem is minimized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasonic thermometry using pulse techniques.

Ultrasonic pulse techniques have been developed which, when applied to inert gases, provide temperature measurements up to 8000 K. The response time can be less than 1 msec. This is a significant feature in studying shock-heated or combusting gases. Using a momentary contact coupling technique, temperature has been measured inside steel from 300 to 1500 K. Thin-wire sensors have been used above 2000 K in nuclear and industrial applications where conditions preclude the use of thermocouples, resistance devices, or optical pyrometers. At 2500 K, temperature sensitivity of 0.1% is obtained in Re wire sensors 5 cm long by timing five round trips with an electronic instrument that resolves the time interval between selected echoes to 0.1 microsec. Sensors have been operated at rotational speeds over 2000 rpm and in noisy environments. Temperature profiling of up to ten regions using only a single guided path or beam has also been accomplished.

Lynnworth, L. C.↗

Further laboratory studies and stratospheric flight of a mass spectrometer beam system

A gas expansion system combined with a mass spectrometer has been tested and flown successfully in the stratosphere. Through a sequence of orifices and high speed pumping, gas particles were formed into a molecular beam and analyzed by a sensitive mass spectrometer. During two balloon flights, vertical profiles of all major atmospheric constituents as well as O3, CO2, H2O and others were obtained. Gases such as AR38 and O16;O17 provided in-flight calibration standards. The sensitivity of the system was such that gases with mixing ratios of 10 ppb at an ambient pressure of about 10 mbar were detectable.

Mauersberger, K.↗

Skin friction measurements by a new nonintrusive double-laser-beam oil viscosity balance technique

A portable dual-laser-beam interferometer that nonintrusively measures skin friction by monitoring the thickness change of an oil film subject to shear stress is described. The method is an advance over past versions in that the troublesome and error-introducing need to measure the distance to the oil leading edge and the starting time for the oil flow has been eliminated. The validity of the method was verified by measuring oil viscosity in the laboratory, and then using those results to measure skin friction beneath the turbulent boundary layer in a low-speed wind tunnel. The dual-laser-beam skin friction measurements are compared with Preston tube measurements, with mean velocity profile data in a 'law-of-the-wall' coordinate system, and with computations based on turbulent boundary-layer theory. Excellent agreement is found in all cases. This validation and the aforementioned improvements appear to make the present form of the instrument usable to measure skin friction reliably and nonintrusively in a wide range of flow situations in which previous methods are not practical.

Monson, D. J.↗

Skin Friction Measurements by a Dual-Laser-Beam Interferometer Technique

A portable dual-laser-beam interferometer that nonintrusively measures skin friction by monitoring the thickness change of an oil film subject to shear stress is described. The method is an advance over past versions in that the troublesome and error-introducing need to measure the distance to the oil leading edge and the starting time for the oil flow has been eliminated. The validity of the method was verified by measuring oil viscosity in the laboratory, and then using those results to measure skin friction beneath the turbulent boundary layer in a low speed wind tunnel. The dual-laser-beam skin friction measurements are compared with Preston tube measurements, with mean velocity profile data in a "law-of-the-well" coordinate system, and with computations based on turbulent boundary-layer theory. Excellent agreement is found in all cases. (This validation and the aforementioned improvements appear to make the present form of the instrument usable to measure skin friction reliably and nonintrusively in a wide range of flow situations in which previous methods are not practical.)

Monson, D. J.↗