Investigation of the characteristics and stability of air-staged flames

The influence of burner aerodynamics on the characteristics of the flame has been studied by means of detailed measurements in a laboratory gas-fired furnace. The distribution of air between two concentric injections and the swirl numbers of both air streams were systematically varied. As a result, a broad range of flames were obtained. The spatial distribution of temperature and species revealed important differences in the configuration of the flame, for which plausible interpretations are proposed. Air-staged flames led to reductions in NO{sub x} emissions down to one third. The fluctuations in pressure and heat release (estimated from OH* chemiluminescence) were characterised in detail. Their standard deviations varied widely with the burner settings, reaching the highest values in some regimes close to flame extinction and also for high staging ratios. Analysis in the frequency domain revealed some characteristic peaks in the pressure spectra, some of them associated with resonant modes of the combustion chamber and the burner. Cross-correlations between the pressure and chemiluminescence signals indicated the onset of thermo-acoustic instabilities for highly air-staged flames, but not for non-staged regimes. This is attributed to the partial premixing achieved before the second combustion stage. The results confirm that the Rayleigh index is related to the magnitude of the fluctuations but, for the cases explored, the threshold associated with the onset of thermo-acoustic coupling might be different depending on the degree of premixing. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring air core characteristics of a pressure-swirl atomizer via a transparent acrylic nozzle at various Reynolds numbers

Because of thermal fluid-property dependence, atomization stability (or flow regime) can change even at fixed operating conditions when subject to temperature change. Particularly at low temperatures, fuel's high viscosity can prevent a pressure-swirl (or simplex) atomizer from sustaining a centrifugal-driven air core within the fuel injector. During disruption of the air core inside an injector, spray characteristics outside the nozzle reflect a highly unstable, nonlinear mode where air core length, Sauter mean diameter (SMD), cone angle, and discharge coefficient variability. To better understand injector performance, these characteristics of the pressure-swirl atomizer were experimentally investigated and data were correlated to Reynolds numbers (Re). Using a transparent acrylic nozzle, the air core length, SMD, cone angle, and discharge coefficient are observed as a function of Re. The critical Reynolds numbers that distinguish the transition from unstable mode to transitional mode and eventually to a stable mode are reported. The working fluids are diesel and a kerosene-based fuel, referred to as bunker-A. (author)

33 ADVANCED PROPULSION SYSTEMS↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Multispectrum analysis of air-broadened spectra in the ν 3 Q branch of 12CH4

In this paper, we report experimental measurements of spectral line shape parameters (air-broadened width, shift, and line mixing coefficients) for several transitions in the ν 3 Q branch of methane in the 3000–3023 cm -1 region. 13 high-resolution, room temperature laboratory spectra of pure methane and air-broadened methane recorded with two different Fourier transform spectrometers are fitted. 12 of these spectra were acquired at 0.01 cm -1 resolution with the McMath-Pierce FTS at the National Solar Observatory on Kitt Peak, and one higher-resolution (~0.0011 cm-1) low pressure methane spectrum was obtained with the Bruker IFS-120HR FTS at the Pacific Northwest National Laboratory, in Richland, Washington. All the spectra were obtained using high purity natural samples of CH 4 and lean mixtures of the same natural CH 4 in dry air. For the 12 spectra recorded at Kitt Peak, three different absorption cells (L= 5, 25 and 150 cm) were used while the methane spectrum at PNNL was obtained using a 19.95 cm long absorption cell. For the analysis, an interactive multispectrum nonlinear least squares fitting software was employed where all the 13 spectra were fitted simultaneously. An accurate and self-consistent set of line parameters were determined by constraining a few of those for severely blended transitions. Line mixing was measured for fourteen transition pairs for the CH 4 -air collision system. Lastly, a constant speed dependence parameter, consistent with measured speed dependence values obtained in other methane bands, was applied to all the transitions included in the fitted region. The present measurements are compared to values reported in the literature.

12CH4↗

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress↗

Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs

The use of artificial roughness on the underside of the absorber plate is an effective and economic way to improve the thermal performance of a solar air heater. Several experimental investigations, involving different types of roughness elements, have been carried out to improve the heat transfer from the absorber plate to air flowing in solar air heaters. This paper presents an experimental investigation carried out to study the effect of multiple v-rib roughness on heat transfer coefficient and friction factor in an artificially roughened solar air heater duct. The experiment encompassed Reynolds number (Re) from 2000 to 20000, relative roughness height (e/D) values of 0.019-0.043, relative roughness pitch (P/e) range of 6-12, angle of attack ({alpha}) range of 30-75 and relative roughness width (W/w) range of 1-10. Extensive experimentation has been conducted to collect data on heat transfer and fluid flow characteristics of a rectangular duct roughened with multiple v-ribs. Using these experimental data, correlations for Nusselt number and friction factor in terms of roughness geometry and flow parameters have been developed. (author)

14 SOLAR ENERGY↗

The Air Toxics Health Effects Database (ATHED)

The Air Toxics Health Effects Database (ATHED) is currently used by the EPA's Office of Air Quality Planning and Standards (OAQPS) to support risk assessments for the Residual Risk Program. An assessment of the residual risk is required to be performed at a specified time (typically 8years) following the promulgation of a technology-based Maximum Achievable Control Technologies (MACT) standard. The goal of the Residual Risk Program is to assure that the risk that remains after MACT standards are implemented (i.e., the 'residual risk') is acceptable, and if not, to propose additional regulations to mitigate those risks. ATHED maintains all available reference values for each chemical as separate data records, and includes values for all exposure durations (acute, short-term, subchronic and chronic). These values are used as benchmarks to determine acceptable exposure levels to the hazardous air pollutants (HAPs) listed in Section 112 of the Clean Air Act. ATHED also provides useful background information on the uncertainty and/or modifying factors that were applied in the derivation of each reference value, as well as the point of departure and the critical study/studies. To facilitate comparisons across durations for a specific chemical, ATHED data can be graphically presented.

60 APPLIED LIFE SCIENCES↗

Impact of East Asian Summer Monsoon on the Air Quality over China: View from space

Tropospheric O3 columns retrieved from OMI and MLS measurements, CO columns from MOPITT, and tropospheric O3 and CO concentrations from TES from May to August in 2006 are analyzed using the Regional chEmical and trAnsport Model (REAM) to investigate the impact of the East Asian summer monsoon on the air quality over China. The observed and simulated migrations of O3 and CO are in good agreement, demonstrating that the summer monsoon significantly affects the air quality over southeastern China and this influence extends to central East China from June to July. Enhancements of CO and O3 over southeastern China disappear after the onset of the summer monsoon and re-emerge in August after the monsoon wanes. The pre-monsoon high O3 concentrations over southern China are due to photochemical production from pollutant emissions and the O3 transport from the stratosphere. In the summer monsoon season, the O3 concentrations are relatively low over monsoon-affected regions because of the transport of marine air masses and weak photochemical activity. We find that the monsoon system strongly modulates the pollution problem over a large portion of East China in summer, depending on its strength and tempo-spatial extension. Model results also suggest that transport from the stratosphere and long-range transport from East China and South/Central Asia all make significant contributions to O3 enhancements over West China. Satellite observations provide valuable information for investigating the monsoon impact on air quality, particularly for the regions with limited in situ measurements.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric-pressure air microplasma jets in aqueous media for the inactivation of Pseudomonas fluorescens cells

The hollow fiber-based cold air microplasma jet array running at atmospheric pressure has been designed to inactivate Pseudomonas fluorescens (P. fluorescens) cells in vitro in aqueous media. The influences of electrode configurations, air flow rate, and applied voltage on the discharge characteristics of the single microplasma jet operating in aqueous media are presented, and the bactericidal efficiency of the hollow fibers-based and large-volume microplasma jet array is reported. Optical emission spectroscopy is utilized to identify excited species during the antibacterial testing of plasma in solutions. These well-aligned and rather stable air microplasma jets containing a variety of short-lived species, such as OH and O radicals and charged particles, are in direct contact with aqueous media and are very effective in killing P. fluorescens cells in aqueous media. This design shows its potential application for atmospheric pressure air plasma inactivation of bacteria cells in aqueous media.

60 APPLIED LIFE SCIENCES↗

Internal air flow analysis of a bladeless micro aerial vehicle hemisphere body using computational fluid dynamic

This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors and the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applying large datasets to developing a better understanding of air leakage measurement in homes

Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. There are several methods for measuring air tightness that may result in different values and sometimes quite different uncertainties. The two main approaches trade off bias and precision errors and thus result indifferent outcomes for accuracy and repeatability. To interpret results from the two approaches, various questions need to be addressed, such as the need to measure the flow exponent, the need to make both pressurization and depressurization measurements and the role of wind in determining the accuracy and precision of the results. This article uses two large datasets of blower door measurements to reach the following conclusions. For most tests the pressure exponent should be measured but for wind speeds greater than 6 m/s a fixed pressure exponent reduces experimental error. The variability in reported pressure exponents is mostly due to changes in envelope leakage characteristics. Finally, it is preferable to test in both pressurization and depressurization modes due to significant differences between the results in these two modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Best Practices Series, Volume 10: Retrofit Techniques and Technologies: Air Sealing

This report was prepared by PNNL for the U.S. Department of Energy Building America Program. The report provides information to home owners who want to make their existing homes more energy efficient by sealing leaks in the building envelope (ceiling, walls, and floors) that let in drafts and let conditioned air escape. The report provides descriptions of 19 key areas of the home where air sealing can improve home performance and energy efficiency. The report includes suggestions on how to find a qualified weatherization or home performance contractor, what to expect in a home energy audit, opportune times for performing air sealing, and what safety and health concerns to be aware of. The report describes some basic building science concepts and topics related to air sealing including ventilation, diagnostic tools, and code requirements. The report will be available for free download from the DOE Building America website. It is a suitable consumer education tool for home performance and weatherization contractors to share with customers to describe the process and value of home energy retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reevaluation of air surveillance station siting

DOE Technical Standard HDBK-1216-2015 (DOE 2015) recommends evaluating air-monitoring station placement using the analytical method developed by Waite. The technique utilizes wind rose and population distribution data in order to determine a weighting factor for each directional sector surrounding a nuclear facility. Based on the available resources (number of stations) and a scaling factor, this weighting factor is used to determine the number of stations recommended to be placed in each sector considered. An assessment utilizing this method was performed in 2003 to evaluate the effectiveness of the existing SRS air-monitoring program. The resulting recommended distribution of air-monitoring stations was then compared to that of the existing site perimeter surveillance program. The assessment demonstrated that the distribution of air-monitoring stations at the time generally agreed with the results obtained using the Waite method; however, at the time new stations were established in Barnwell and in Williston in order to meet requirements of DOE guidance document EH-0173T.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Richland Campus

This is the second revision of the DQO Supporting Radiological Air Emissions Monitoring for the Pacific Northwest National Laboratory Richland Campus. In January 2017, the PNNL Richland Campus expanded to the north by 0.35 km 2 (85.6 acres). Under the requirements of Washington State Department of Health Radioactive Air Emissions License (RAEL)-005, the PNNL Campus operates and maintains a radiological air monitoring program. This revision documents and evaluates the newly acquired acreage while also removing recreational land at the southwest, and also re-examines all active radioactive emission units on the PNNL Campus. No buildings are located on this new Campus land, which was transferred from the U.S. DOE Hanford Site. Additionally, this revision includes information regarding the background monitoring station PNL-5 in Benton City, Washington, which became active in October 2016. The key purpose of this revision is to determine the adequacy of the existing environmental surveillance stations to monitor radiological air emissions in light of this northern boundary change.

40 CFR 61 Subpart H↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon Capture on Air Liquide United States Gulf Coast Steam Methane Reformer using the Cryocap TM Flue Gases Process

The objective of this DOE-funded project is to execute and complete a Front-End Engineering and Design (FEED) study for a commercial-scale carbon capture project for Air Liquide’s Steam Methane Reformer (SMR) located at La Porte, near Houston, Texas. The Host Site is one of Air Liquide’s largest SMR assets, and supplies hydrogen to the Air Liquide Gulf Coast Hydrogen System, which serves refiners and petrochemical manufacturers through an existing H2 pipeline spanning roughly 200 miles from Port Arthur, TX to Bay City, TX. The Host Site produces up to 116.5 million standard cubic feet per day (MMSCFD) of gaseous hydrogen and emits approximately 950 ktpy CO 2 at the nameplate capacity. The evolving importance of decarbonized H2 for both existing customers and new markets, as well as the availability and intent of prominent third-party partners to transport and sequester captured CO 2 in locally abundant geological sites for 45Q credits, make the AL US Gulf Coast SMR an ideal site for the proposed FEED study. The envisioned carbon capture system is based on Air Liquide’s proprietary Cryocap™ Flue Gas (FG) process. The integration of the Cryocap™ FG technology to the existing SMR would enable the capture of 900 ktpy of CO 2 , with a net carbon capture rate of >95% and with minimum impact on the levelized cost of hydrogen produced at 99.97% purity.