At least 1,585 records · Page 88

Influence of velocity of pressing in RCS processed AA8090 Al-Li alloy

Highlights: • For the first time the Influence of RCS on the properties of AA 8090 has been studied by processing velocity. • It is found that the properties vary according to pressing velocity and number of passes. • Reported significant property improvement achieved through the pressing velocity of 1.5mm/s. - Abstract: The effect of the velocity of pressing on grain refinement in AA8090 Al-Li alloy sheets during repetitive corrugation and straightening (RCS) at 300 °C is studied. V-groove corrugation dies and flattening dies were used at three different pressing velocities of 1.5 mm/s, 2 mm/s and 2.5 mm/s. The specimen temperature was maintained at 300 °C. Grain refinement was significantly influenced by the pressing velocity. The samples processed for 8 passes at a pressing velocity of 1.5 mm/s had an improved microhardness value of 104 HV and an increased tensile strength of 405 MPa which is respectively 39% and 113% more than the corresponding values in the parent material. TEM analysis showed that samples processed at a pressing velocity of 1.5 mm/s had in places a grain size down to 50 nm and the EBSD results revealed that the average grain size was 2 μm, with 86% of the total number of grain boundaries of the high angle type.

36 MATERIALS SCIENCE↗

A novel method for preparing pomegranate-structured FePO{sub 4}/C composite materials as cathode for lithium-ion batteries

Graphical abstract: Display Omitted Highlights: ► We designed and synthesized a pomegranate-structured FePO{sub 4}/C composite. ► We used a combination of electrospinning and solid-state reaction for preparation. ► We showed how the performance of pomegranate-structured FePO{sub 4} is highly enhanced. -- Abstract: A pomegranate-structured FePO{sub 4}/C composite was synthesized via a combination of electrospinning and high temperature reaction using micron-level FePO{sub 4} and polyacrylonitrile (PAN). Systematic studies on synthesis, modification, and characterization of FePO{sub 4}/C composites were conducted. The FePO{sub 4}/C composites delivered a specific discharge capacity of 109 mAh g{sup −1} at 0.2 C and 39 mAh g{sup −1} at 10 C, which were comparable with the reported nanometer-level FePO{sub 4}. We demonstrated that the three-dimensional net-like structure covered by porous carbon layers could highly enhance the electrochemical performance of FePO{sub 4}.

36 MATERIALS SCIENCE↗

Long range B-site cation ordering and Briet–Wigner–Fano line shape of A{sub 1g}-like Raman mode in Nd{sub 1−x}Sm{sub x}(Mg{sub 0.5}Ti{sub 0.5})O{sub 3} microwave dielectric ceramics

Graphical abstract: Display Omitted Highlights: ► Q × f of Nd{sub 1–x}Sm{sub x}(Mg{sub 0.5}Ti{sub 0.5})O{sub 3} are correlated with B-site cation ordering (LRO). ► Correlation between LRO and Γ of A{sub 1g}-like mode in Raman spectrum is observed. ► Reason for asymmetry in A{sub 1g}-like Raman mode in these materials is revealed. ► Briet–Wigner–Fano resonance is confirmed with temperature variation in Raman spectra. -- Abstract: Nd{sub 1−x}Sm{sub x}(Mg{sub 0.5}Ti{sub 0.5})O{sub 3} (x = 0.0–1.0) samples were prepared by solid-state reaction method. Rietveld refinement of X-ray diffraction data was done using P2{sub 1}/n space group with monoclinic symmetry, which supports 1:1 B-site cation ordering. Long range ordering (LRO) parameter decreased up to x = 0.5 and then found to increase with further increase in Sm concentration. The A{sub 1g}-like mode in Raman spectra was observed to possess Briet–Wigner–Fano line shape. The variation in obtained line width of the A{sub 1g}-like mode supported LRO. Microwave dielectric characteristics such as dielectric constant (ε{sub r}), quality factor (Q) and temperature coefficient of resonant frequency (τ{sub f}) were measured in the range of 7–9 GHz. ε{sub r} decreased from 26.5 to 24.9 and τ{sub f} become less negative from −58 ppm/°C to −36 ppm/°C with increase in Sm concentration. Q × f decreased from 47,500 GHz (for x = 0) to 39,800 GHz (for x = 0.5) and then increased to 44,600 GHz (for x = 1).

36 MATERIALS SCIENCE↗

Visible light absorption of TiO{sub 2} materials impregnated with tungstophosphoric acid ethanol–aqueous solution at different pH values. Evidence about the formation of a surface complex between Keggin anion and TiO{sub 2} surfaces

Graphical abstract: - Highlights: • TPA impregnation on TiO{sub 2} particles was done at different initial pH values. • Powders characterization evidenced the possible existence of TPA–TiO{sub 2} complexes. • Keggin anion complexed on TiO{sub 2} would be responsible of visible light absorption. - Abstract: TiO{sub 2} particles prepared by the sol–gel method were impregnated at different pH values (1.0, 2.0, 5.0 and 10.0) with a water–ethanol solution (50% V/V) of tungstophosphoric acid (TPA) (0.012 M). Similar preparation was carried out to synthesize TiO{sub 2} impregnated with [WO{sub 4}]{sup 2−} (TiW). These materials were characterized by different techniques such as UV–vis diffuse reflectance spectroscopy (UV–vis DRS), magic angle spinning nuclear magnetic resonance of {sup 31}P ({sup 31}P MAS NMR), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), Fourier transform Raman spectroscopy (FT-Raman). Results revealed that TPA–TiO{sub 2} materials exhibit visible light absorption only when impregnation was done at pH 1.0 (TiTPA1) and 2.0 (TiTPA2). TiW powder did not show visible light absorption. XRD patterns show the presence of peaks at 2θ = 25.4° (1 0 1), 37.9° (0 0 4), 47.8° (2 0 0) and 54.3° associated to the anatase phase. Solid NMR, FT-IR and FT-Raman characterization showed that TiTPA1 and TiTPA2 samples contain Keggin ([PW{sub 12}O{sub 40}]{sup 3−}) and lacunary anions ([PW{sub 11}O{sub 39}]{sup 7−}) respectively. On the other hand, FT-Raman results revealed a blue shifting and broadening of the band at 141 cm{sup −1} corresponding to anatase TiO{sub 2} and moreover, a broadening of bands at 900–1100 cm{sup −1} attributed to Keggin structures of TPA. Both spectral changes could be related to the formation of a surface complex between the Keggin anion of TPA and TiO{sub 2} surfaces. This interaction should be responsible for visible light absorption.

36 MATERIALS SCIENCE↗

Effects of the annealing process on the structure and valence state of vanadium oxide thin films

Highlights: • TGA-DSC was used to determine the annealing temperature generally. • Pure VO{sub 2} (M) film was obtained with some annealing process. • The film surface transits from layer to grains as the annealing temperature increases. • Spans of O1s and V2p{sub 3/2} core level of V{sup 5+}, V{sup 4+}, V{sup 3+} were 12.75, 14.0 and 14.7 eV. • The Tc of pure VO{sub 2} (M) was 64.3 °C, its hysteresis loop width was 12.1 °C. - Abstract: V{sub 2}O{sub 5} was used to prepare vanadium oxide films via the sol-gel method. The “n” in V{sub 2}O{sub 5}∙nH{sub 2}O was determined to be approximately 1.67. After annealing at 390 °C for 4 h, a pure VO{sub 2} (M) phase was obtained and denoted sample Ⅴ. The crystallite sizes of VO{sub 2} (M) in samples Ⅱ, Ⅲ, Ⅳ and Ⅴ were 42, 41, 35 and 24 nm, respectively. The surface morphology of sample Ⅰ was flat; however, many small, dense particles covered the surface of sample Ⅴ. Sample Ⅱ had a layered structure, and samples Ⅲ and Ⅳ consisted of compact grains. The binding energy (BE) differences between the O1s and the V{sup 5+}2p{sub 3/2}, V{sup 4+}2p{sub 3/2}, and V{sup 3+}2p{sub 3/2} core levels were 12.75, 14.0 and 14.7 eV, respectively. For the sample Ⅴ film, the maximum transmittance change at 2500 nm was 39%, the phase transition temperature (Tc) was 64.3 °C, and the hysteresis loop width was 12.1 °C.

36 MATERIALS SCIENCE↗

Electrophoretic deposition for improved trace element homogeneity in silica reference materials

Spatially-resolved analysis requires homogeneous reference materials (RMs) to make reliable quantitative measurements. Here we previously developed an electrophoretic deposition (EPD) method for fabrication of glassy microanalytical RMs with superior platinum-group element homogeneity **[1], and now include further dopants. For 39 trace elements, we analyzed dopant homogeneity in sintered silica (SiO 2 ) samples consolidated either mechanically by die-pressing (DP) or by EPD. A set of EPD and DP samples was made from each of two nanoparticle feedstocks produced by variations of the Stöber process **[2]. Spatially-resolved dopant distribution was characterized in all samples by laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS). In both sample sets, homogeneity of most trace elements was substantially improved by EPD relative to their DP counterpart.

36 MATERIALS SCIENCE↗

Feasibility of IMRT to Cover Pelvic Nodes While Escalating the Dose to the Prostate Gland: Dosimetric Data on 35 Consecutive Patients

Utilizing available dosimetric and acute toxicity data, we confirm the feasibility of intensity modulated radiotherapy (IMRT) to include treatment of the pelvic nodes (PN) while escalating the dose to the prostate. Data were obtained from 35 consecutive patients with prostate cancer with {>=}15% risk of PN involvement. Patients received an initial boost to the prostate, delivering 16 Gy over 8 fractions using a 6-field conformal technique, followed by an 8-field coplanar inverse planning IMRT technique delivering an additional 60 Gy over 30 fractions to the prostate (76 Gy total) and 54 Gy over 30 fractions to the seminal vesicles (SV) and PN. Dose-volume histogram analysis was performed for planning target volumes and organs at risk. Acute toxicity (RTOG/EORTC scale) was prospectively and independently scored weekly for each patient. The maximum, mean, minimum dose, and D95 to each planning target volume is provided: prostate (82.2, 78.2, 72.6, 75.2 Gy), SV (79.0, 72.5, 56.9, 61.1 Gy), and PN (80.4, 59.7, 46.5, 53.3 Gy), respectively. The percent volume receiving a dose at or above 'x' Gy (Vx) was recorded for V75, V70, V65, V60, and V50 as: bladder (14%, 24%, 32%, 39%, and 54%) and rectum (3%, 18%, 26%, 34%, and 51%), respectively. Acute toxicity was as follows: 54% grade 2+ GI (n = 19), 25% grade 2+ GU (n = 9). IMRT enables treatment of pelvic nodes while escalating dose to the prostate and is clinically feasible with acute toxicity within expected ranges.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Treatment Planning Investigation Into the Dosimetric Effects of Systematic Prostate Patient Rotational Set-Up Errors

The purpose of this study was to investigate the potential dosimetric effects of systematic rotational setup errors on prostate patients planned according to the RTOG P-0126 protocol, and to identify rotational tolerances about either the anterior-posterior (AP) or left-right (LR) axis, under which no correction in setup is required. Eight 3-dimensional conformal radiation therapy (3D-CRT) treatment plans were included in the study, half planned to give 7020 cGy in 39 fractions (P-0126 Arm 1) and the other half planned to give 7920 cGy in 44 fractions (P-0126 Arm 2). Systematic rotations of the pelvic anatomy were simulated in a commercial treatment planning system by rotating opposing apertures in the opposite direction to the simulated anatomy rotation. Rotations were incremented in steps of 2.5 deg. to a maximum of {+-}5.0 deg. and {+-}10.0 deg. the AP and LR axis respectively. Dose distributions were evaluated with respect to the planning objectives set out in the P-0126 protocol. For patients on Arm 2 of the study, maintaining the prescribed dose to 98% of the PTV was found to be problematic for superior-end-posterior rotations beyond 5.0 deg. The results also show that maintaining a rectal dose less than 7500 cGy to 15% of the volume can become problematic for cases of small rectal volume and large superior-end-anterior rotations. We found that setting rotational tolerances will depend on which Arm of the protocol the patient is, and how well the initial plan meets the protocol objectives. In general, we conclude that for rotations about the AP axis, no tolerance level is required; however, cases presenting extreme rotations should be investigated as routine practice. For rotations about the LR axis, we conclude that a tolerance level for patients on Arm 2 of the protocol should be set at {+-}5.0 deg. This tolerance represents the systematic setup error which would require correction if a variation to the initial plan was deemed unacceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-modulated radiosurgery with rapidarc for multiple brain metastases and comparison with static approach

Rotational RapidArc (RA) and static intensity-modulated radiosurgery (IMRS) have been used for brain radiosurgery. This study compares the 2 techniques from beam delivery parameters and dosimetry aspects for multiple brain metastases. Twelve patients with 2-12 brain lesions treated with IMRS were replanned using RA. For each patient, an optimal 2-arc RA plan from several trials was chosen for comparison with IMRS. Homogeneity, conformity, and gradient indexes have been calculated. The mean dose to normal brain and maximal dose to other critical organs were evaluated. It was found that monitor unit (MU) reduction by RA is more pronounced for cases with larger number of brain lesions. The MU-ratio of RA and IMRS is reduced from 104% to 39% when lesions increase from 2 to 12. The dose homogeneities are comparable in both techniques and the conformity and gradient indexes and critical organ doses are higher in RA. Treatment time is greatly reduced by RA in intracranial radiosurgery, because RA uses fewer MUs, fewer beams, and fewer couch angles.

61 RADIATION PROTECTION AND DOSIMETRY↗

A study on planning organ at risk volume for the rectum using cone beam computed tomography in the treatment of prostate cancer

In this study, we analyzed planning organ at risk volume (PRV) for the rectum using a series of cone beam computed tomographies (CBCTs) acquired during the treatment of prostate cancer and evaluated the dosimetric effect of different PRV definitions. Overall, 21 patients with prostate cancer were treated radically with 78 Gy in 39 fractions had in total 418 CBCTs, each acquired at the end of the first 5 fractions and then every alternate fraction. The PRV was generated from the Boolean sum volume of the rectum obtained from first 5 fractions (PRV-CBCT-5) and from all CBCTs (PRV-CBCT-All). The PRV margin was compared at the superior, middle, and inferior slices of the contoured rectum to compare PRV-CBCT-5 and PRV-CBCT-All. We also compared the dose received by the planned rectum (Rectum-computed tomography [CT]), PRV-CBCT-5, PRV-CBCT-All, and average rectum (CBCT-AV-dose-volume histogram [DVH]) at critical dose levels. The average measured rectal volume for all 21 patients for Rectum-CT, PRV-CBCT-5, and PRV-CBCT-All was 44.3 ± 15.0, 92.8 ± 40.40, and 121.5 ± 36.7 cm{sup 3}, respectively. For PRV-CBCT-All, the mean ± standard deviation displacement in the anterior, posterior, right, and left lateral directions in centimeters was 2.1 ± 1.1, 0.9 ± 0.5, 0.9 ± 0.8, and 1.1 ± 0.7 for the superior rectum; 0.8 ± 0.5, 1.1 ± 0.5, 1.0 ± 0.5, and 1.0 ± 0.5 for the middle rectum; and 0.3 ± 0.3; 0.9 ± 0.5; 0.4 ± 0.2, and 0.5 ± 0.3 for the inferior rectum, respectively. The first 5 CBCTs did not predict the PRV for individual patients. Our study shows that the PRV margin is different for superior, middle, and the inferior parts of the rectum, it is wider superiorly and narrower inferiorly. A uniform PRV margin does not represent the actual rectal variations during treatment for all treatment fractions. The large variation in interpatient rectal size implies a potential role for adaptive radiotherapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of lung and target density on small-field dose coverage and PTV definition

We have studied the effect of target and lung density on block margin for small stereotactic body radiotherapy (SBRT) targets. A phantom (50 × 50 × 50 cm{sup 3}) was created in the Pinnacle (V9.2) planning system with a 23-cm diameter lung region of interest insert. Diameter targets of 1.6, 2.0, 3.0, and 4.0 cm were placed in the lung region of interest and centered at a physical depth of 15 cm. Target densities evaluated were 0.1 to 1.0 g/cm{sup 3}, whereas the surrounding lung density was varied between 0.05 and 0.6 g/cm{sup 3}. A dose of 100 cGy was delivered to the isocenter via a single 6-MV field, and the ratio of the average dose to points defining the lateral edges of the target to the isocenter dose was recorded for each combination. Field margins were varied from none to 1.5 cm in 0.25-cm steps. Data obtained in the phantom study were used to predict planning treatment volume (PTV) margins that would match the clinical PTV and isodose prescription for a clinical set of 39 SBRT cases. The average internal target volume (ITV) density was 0.73 ± 0.17, average local lung density was 0.33 ± 0.16, and average ITV diameter was 2.16 ± 0.8 cm. The phantom results initially underpredicted PTV margins by 0.35 cm. With this offset included in the model, the ratio of predicted-to-clinical PTVs was 1.05 ± 0.32. For a given target and lung density, it was found that treatment margin was insensitive to target diameter, except for the smallest (1.6-cm diameter) target, for which the treatment margin was more sensitive to density changes than the larger targets. We have developed a graphical relationship for block margin as a function of target and lung density, which should save time in the planning phase by shortening the design of PTV margins that can satisfy Radiation Therapy Oncology Group mandated treatment volume ratios.

61 RADIATION PROTECTION AND DOSIMETRY↗

Partial breast radiotherapy with simple teletherapy techniques

A prospective pilot study of partial breast irradiation (PBI) with conventional vs hypofractionated schedules was set out. The study aimed to determine efficacy, acute and late side effects, and the preference of photon vs electron irradiation based on individual features. Patients were enrolled according to internationally accepted guidelines on PBI. Conformal radiotherapy plans were generated with both photon and electron beams, and the preferred technique based on dose homogeneity and the radiation exposure of healthy tissues was applied. For electron dose verification, a special phantom was constructed. Patients were randomized for fractionation schedules of 25 × 2 vs 13 × 3 Gy. Skin and breast changes were registered at the time of and ≥1 year after the completion of radiotherapy. Dose homogeneity was better with photons. If the tumor bed was located in the inner quadrants, electron beam gave superior results regarding conformity and sparing of organ at risk (OAR). If the tumor was situated in the lateral quadrants, conformity was better with photons. A depth of the tumor bed ≥3.0 cm predicted the superiority of photon irradiation (odds ratio [OR] = 23.6, 95% CI: 5.2 to 107.5, p < 0.001) with >90% sensitivity and specificity. After a median follow-up of 39 months, among 72 irradiated cases, 1 local relapse out of the tumor bed was detected. Acute radiodermatitis of grade I to II, hyperpigmentation, and telangiectasia developed ≥1 year after radiotherapy, exclusively after electron beam radiotherapy. The choice of electrons or photons for PBI should be based on tumor bed location; the used methods are efficient and feasible.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels

The aim of this study is to evaluate the incidental testicular doses during prostate radiation therapy with intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) at different energies. Dosimetric data of 15 patients with intermediate-risk prostate cancer who were treated with radiotherapy were analyzed. The prescribed dose was 78 Gy in 39 fractions. Dosimetric analysis compared testicular doses generated by 7-field intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy with a single arc at 6, 10, and 15 MV energy levels. Testicular doses calculated from the treatment planning system and doses measured from the detectors were analyzed. Mean testicular doses from the intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy per fraction calculated in the treatment planning system were 16.3 ± 10.3 cGy vs 21.5 ± 11.2 cGy (p = 0.03) at 6 MV, 13.4 ± 10.4 cGy vs 17.8 ± 10.7 cGy (p = 0.04) at 10 MV, and 10.6 ± 8.5 cGy vs 14.5 ± 8.6 cGy (p = 0.03) at 15 MV, respectively. Mean scattered testicular doses in the phantom measurements were 99.5 ± 17.2 cGy, 118.7 ± 16.4 cGy, and 193.9 ± 14.5 cGy at 6, 10, and 15 MV, respectively, in the intensity-modulated radiotherapy plans. In the volumetric-modulated arc radiotherapy plans, corresponding testicular doses per course were 90.4 ± 16.3 cGy, 103.6 ± 16.4 cGy, and 139.3 ± 14.6 cGy at 6, 10, and 15 MV, respectively. In conclusions, this study was the first to measure the incidental testicular doses by intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy plans at different energy levels during prostate-only irradiation. Higher photon energy and volumetric-modulated arc radiotherapy plans resulted in higher incidental testicular doses compared with lower photon energy and intensity-modulated radiotherapy plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of pectin-degrading fungal communities in temperate forests using glycosyl hydrolase family 28 pectinase primers targeting Ascomycete fungi

Here, fungi have developed a wide assortment of enzymes to break down pectin, a prevalent polymer in plant cell walls that is important in plant defense and structure. One enzyme family used to degrade pectin is the glycosyl hydrolase family 28 (GH28). In this studywe developed primers for the amplification of GH28 coding genes from a database of 293 GH28 sequences from40 fungal genomes. The primerswere used to successfully amplify GH28 pectinases from all Ascomycota cultures tested, but only three out of seven Basidiomycota cultures. In addition, we further tested the primers in PCRs on metagenomic DNA extracted from senesced tree leaves from different forest ecosystems, followed by cloning and sequencing. Taxonomic specificity for Ascomycota GH28 genes was tested by comparing GH28 composition in leaves to internal transcribed spacer (ITS) amplicon composition using pyrosequencing. All sequences obtained from GH28 primers were classified as Ascomycota; in contrast, ITS sequences indicated that fungal communitieswere up to 39% Basidiomycetes. Analysis of leaf samples indicated that both forest stand and ecosystemtype were important in structuring fungal communities. However, site played the prominent role in explaining GH28 composition, whereas ecosystem type was more important for ITS composition, indicating possible genetic drift between populations of fungi. Overall, these primers will have utility in understanding relationships between fungal community composition and ecosystem processes, as well as detection of potentially pathogenic Ascomycetes.

59 BASIC BIOLOGICAL SCIENCES↗

Highly thermally stable copolymers of epoxy and trifunctional polybenzoxazine

Here, in this work, we report the copolymerization of a triamine-based benzoxazine and a commercial difunctional epoxy resin, and investigate their synergistic effect on improved thermal properties using differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Results showed that a glass transition temperature increase of up to 268 °C was obtained for the copolymer with as low as 25 wt% epoxy. A higher thermal performance was also achieved with an onset degradation of nearly 400 °C and char yield of 39 wt% at 800 °C for the copolymer with 52 wt% epoxy. The behavior was compared to previously reported benzoxazine/epoxy combinations and was found to be advantageous. The curing behavior of different copolymer compositions was also investigated via DSC and a methodology for matching each peak with its corresponding reaction was developed. Results showed that the alternating favorability of the reactions was dependent on the benzoxazine/epoxy ratio. Overall, the prepared PBZ/epoxy copolymers displayed higher thermal stability than their individual components, indicating suitability for a number of potential extended uses including utility in higher temperature applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of multifunctional nylon 6,6-based nanocomposites with high electrical and thermal conductivities by scalable melt and dry blending methods for automotive applications

With the advent of intelligent automobile technology, the demand for multifunctional composites with higher electrical and thermal conductivities is increasing. We have herein reported for the first time the effect of polyolester on the dispersion of carbon nanotube (CNT) in the short-carbon fiber (CF)/nylon 6,6 (PA66) composite using a scalable melt-mixing and dry-blending method and its subsequent improvement in electrical and thermal conductivities. Masterbatches were prepared with a higher concentration of CNT (both untreated and polyolester-treated) followed by dry blended with reference composite (30 wt% CF and 10 wt% mineral fiber filled PA66) before making coupons via injection molding. A 500% and 63% improvements in electrical (3.14 S cm -1 ) and thermal conductivities (in-plane) (1.99 W m -1 K -1 ) conductivities were observed by adding 1.5 wt% treated CNT compared to the reference composite. The improvements were even higher than that of untreated CNT due to better dispersion. Furthermore, the electromagnetic shielding effectiveness reached 61 dB for 1.5 wt% treated CNT-filled composite (39% enhancement). In conclusion, these results are significant in imparting multiple functionalities to the automotive composite parts.

36 MATERIALS SCIENCE↗

Omega-Limit Sets and Input-To-State Stability in Power Grids with Switching Equilibria

This paper studies a power transmission system with both conventional generators (CGs) and distributed energy assets (DEAs) providing frequency control. We consider an operating condition with demand aggregating two dynamic components: one that switches between different values on a finite set, and one that varies smoothly over time. Such dynamic operating conditions may result from protection scheme activations, external cyber-attacks, or due to the integration of dynamic loads, such as data centers. Mathematically, the dynamics of the resulting system are captured by a system that switches between a finite number of vector fields - or modes -, with each mode having a distinct equilibrium point induced by the demand aggregation. To analyze the stability properties of the resulting switching system, we leverage tools from hybrid dynamic inclusions and the concept of ..omega.. -limit sets from sets. Specifically, we characterize a compact set that is semi-globally practically asymptotically stable under the assumption that the switching frequency and load variation rate are sufficiently slow. For arbitrarily fast variations of the load, we use a level-set argument with multiple Lyapunov functions to establish input-to-state stability of a larger set and with respect to the rate of change of the loads. The theoretical results are illustrated via numerical simulations on the IEEE 39-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗