Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “upgrades”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

The Relativistic Heavy Ion Collider (RHIC) cryogenic system at Brookhaven National Laboratory: Review of the modifications and upgrades since 2002 and planned improvements.

Brookhaven National Laboratory continues its multi-year program to improve the operational efficiency, reliability, and stability of the cryogenic system, which also resulted in an improved beam availability of the Relativistic Heavy Ion Collider (RHIC). This paper summarizes the work and changes made after each phase over the past four years to the present, as well as proposed future improvements. Power usage dropped from an initial 9.4 MW to the present 5.1 MW and is expected to drop below 5 MW after the completion of the remaining proposed improvements. The work proceeded in phases, balancing the Collider's schedule of operation, time required for the modifications and budget constraints. The main changes include process control, compressor oil removal and management, elimination of the use of cold compressors and two liquid-helium storage tanks, insulation of the third liquid-helium storage tank, compressor-bypass flow reduction and the addition of a load turbine (Joule-Thomson ex

74 ATOMIC AND MOLECULAR PHYSICS↗

Upgrading and testing the 3D reconstruction of gamma-ray air showers as observed with an array of Cherenkov telescopes

Stereoscopic arrays of Imaging Cherenkov Telescopes allow to reconstruct gamma-ray-induced showers in 3 dimensions. An analysis method based on a simple 3D-model of electromagnetic showers and implemented in the framework of the H.E.S.S. experiment was recently improved by an additional quality criterion which reduces the background contamination by a factor of about 2 in the case of extended sources, while hardly affecting gamma-ray selection efficiency. Moreover, the dramatic flares of PKS 2155-304 in July 2006, which provided H.E.S.S. data with an almost pure gamma-ray sample, offered the unique opportunity of a precision test of the 3D-reconstruction method as well as of the H.E.S.S. simulations used in its calibration. An agreement at a few percent level is found between data and simulations for the distributions of all 3D shower parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

The Large-Area Time-Of-Flight (TOF) Upgrade for the STAR Detector

The STAR experiment at RHIC concentrates on the tracking of charged hadrons via ionization in gas- and silicon-based detectors, and the detection of electrons and photons via calorimetry, in a wide and azimuthally complete acceptance that's unique at RHIC. STAR's ability to directly identify the tracked charged hadrons is however limited to low momenta. Approximately half of the charged particles in the event at higher momenta cannot be directly identified, which hampers the physics reach of STAR in a number of key areas. To address this blind spot, STAR is presently constructing a large-area ({approx}50 m{sup 2}) Time-Of-Flight (TOF) system. This system is based on Multi-gap Resistive Plate Chambers (MRPCs). Prototype TOF systems based on this technology were operated in STAR during RHIC Runs 3 through 6, and the first 5 final-system trays were operated in the recent RHIC Run 8. A new 'start detector' for this system has also been constructed and operated in STAR. The performance of these detectors in STAR, and an update on the status of the construction of the full system, is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STAR Vertex Detector Upgrade-HFT Pixel Development

Development and prototyping efforts directed towards construction of a new vertex detector for the STAR experiment at the RHIC accelerator at BNL are presented. This new detector will extend the physics range of STAR by allowing for precision measurements of yields and spectra of particles containing heavy quarks. The innermost central part of the new detector is a high resolution pixel-type detector (PIXEL). PIXEL requirements are discussed as well as a conceptual mechanical design, a sensor development path, and a detector readout architecture. Selected progress with sensor prototypes dedicated to the PIXEL detector is summarized and the approach chosen for the readout system architecture validated in tests of hardware prototypes is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization Upgrade at ELSA

The Electron Stretcher Accelerator ELSA at Bonn University is a fast ramping stretcher ring supplying a polarized electron beam of up to 3.5 GeV to hadron physics experiments. During acceleration (4.5 GeV/sec), sophisticated schemes for the compensation of depolarizing resonances are mandatory, such as betatron tune jumps for intrinsic resonances and harmonic closed orbit corrections for imperfection resonances. This contribution will present recently implemented techniques of dynamic closed orbit correction as well as the newly developed orbit correction system which reduces the time needed for an orbit bump application down to well below 20 milliseconds.

43 PARTICLE ACCELERATORS↗

PHENIX Detector Upgrade for Triggering Fast Muons from W-Boson Decays Using RPC Technology

The BNL PHENIX experiment is designed for studying matter properties at ultra high temperatures and densities with heavy ion collisions, and the spin structure of the proton via polarized proton+proton collisions. A fast trigger system, based on the resistive plate chamber (RPC), is being developed for the muon arms that allows the measurement of the flavor structure of quark polarization in the proton through observation of W-bosons in proton+proton collisions at sq root(s) = 500 GeV. This talk will focus on RPC R and D, production of the RPC components, and assembly of the RPC modules at BNL. Challenges of RPC integration into PHENIX will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements in electron cyclotron emission imaging demonstrated by the TEXTOR ECEI diagnostic upgrade

A new TEXTOR electron cyclotron emission imaging system has been developed and employed, providing a diagnostic with new features and enhanced capabilities when compared to the legacy system it replaces. Optical coupling to the plasma has been completely redesigned, making use of new minilens arrays for reduced optical aberration and providing the new feature of vertical zoom, whereby the vertical coverage is now remotely adjustable on a shot-by-shot basis from 20-35 cm. Other innovations, such as the implementation of stacked quasioptical planar notch filters, allow for the diagnostic to be operated without interruption or degradation in performance during electron cyclotron resonance heating. Successful commissioning of the new diagnostic and a demonstration of the improved capabilities are presented in this paper, along with a discussion of the new technologies employed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operation and upgrade of diagnostic neutral beam injector RUDI at TEXTOR tokamak

The status and the executing modernization of RUssian Diagnostic Injector (RUDI) are described. The ion source consists of arc plasma emitter and multiaperture four-electrode ion optical system. The present ion optical system with round beamlets is to be replaced by new slit apertures system for the reducing beam angular divergence in one direction. Due to enlarged dimensions and transparency of new ion optical system the extracted ion beam current will be by 50% increased. For the extension of beam pulse duration from 4 s to 8-10 s an optimized metal-ceramic arc-discharge channel is introduced. In the paper, the optical measurements results of beam parameters, including the profile of species distribution, scanned by custom-built multichannel spectroscope, are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Average and recommended half-life values for two neutrino double beta decay: upgrade-09

All existing 'positive' results on two neutrino double beta decay in different nuclei were analyzed. Using the procedure recommended by the Particle Data Group, weighted average values for half-lives of {sup 48}Ca, {sup 76}Ge, {sup 82}Se, {sup 96}Zr, {sup 100}Mo, {sup 100}Mo-{sup 100}Ru(0{sub 1}{sup +}), {sup 116}Cd, {sup 130}Te, {sup 150}Nd, {sup 150}Nd-{sup 150}Sm(0{sub 1}{sup +}) and {sup 238}U were obtained. Existing geochemical data were analyzed and recommended values for half-lives of {sup 128}Te, {sup 130}Te and {sup 130}Ba are proposed. We recommend the use of these results as presently the most precise and reliable values for half-lives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design Concepts For A Long Pulse Upgrade For The DIII-D Fast Wave Antenna Array

A goal in the 5-year plan for the fast wave program on DIII-D is to couple a total of 3.6 MW of RF power into a long pulse, H-mode plasma for central electron heating. The present short-pulse 285/300 antenna array would need to be replaced with one capable of at least 1.2 MW, 10 s operation at 60 MHz into an H-mode (low resistive loading) plasma condition. The primary design under consideration uses a poloidally-segmented strap (3 sections) for reduced strap voltage near the plasma/Faraday screen region. Internal capacitance makes the antenna structure self-resonant at 60 MHz, strongly reducing peak E-fields in the vacuum coax and feed throughs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an H{sup -} ion source for Japan Proton Accelerator Research Complex upgrade

A cesium (Cs) free H{sup -} ion source driven with a lanthanum hexaboride (LaB{sub 6}) filament was adopted as an ion source for the first stage of the Japan Proton Accelerator Research Complex (J-PARC). At present, the maximum H{sup -} ion current produced by the ion source is 38 mA, using which J-PARC can produce a proton beam power of 0.6 MW by accelerating it with the 181 MeV linac and the 3 GeV rapid cycling synchrotron. In order to satisfy the beam power of 1 MW required for the second stage of the J-PARC in the near future, we have to increase the ion current to more than 60 mA. Therefore, we have started to develop a Cs-seeded ion source by adding an external Cs-seeding system to a J-PARC test ion source that has a structure similar to that of the J-PARC ion source except for the fact that the plasma chamber is slightly larger. As a result, a H{sup -} ion current of more than 70 mA was obtained from the ion source using a tungsten filament instead of a LaB{sub 6} filament with a low arc discharge power of 15 kW (100 V, 150 A).

43 PARTICLE ACCELERATORS↗

Upgrade of the extraction system of permanent magnet electron cyclotron resonance ion source

A set of new ion extraction electrodes have been designed for the permanent magnetic electron cyclotron resonance ion source at Peking University to improve beam quality and transmission. PBGUNS has been used to optimize the extraction electrodes and simulate the beam behavior at the extraction region. The experiments showed that with the new system, the beam half divergence angle can be less than 40 mrad and the normalized rms emittance is about 0.13{pi} mm mrad when the extracted current is 100 mA at 50 keV in pulse mode. The voltage of the suppression electrode has great effect on beam divergence. The effect of the microwave power and gas flow is also studied.

43 PARTICLE ACCELERATORS↗

Polarized Compton Scattering and Nucleon Spin Polarizabilities at the Upgraded HI{gamma}S Facility

The HI{gamma}S facility is capable of providing intense beams of linearly and circularly polarized gamma rays, at energies from 2 MeV and soon to extend up to 100 MeV. This paper describes a Compton scattering program which has been designed to measure the electric and magnetic polarizabilities of the proton and the neutron, as well as the spin-polarizabilities of both. Linearly polarized beams will be used to measure the electric and magnetic polarizabilities of the proton, while Compton scattering from the deuteron will lead to values of these fundamental quantities for the neutron. Circularly polarized beams and polarized proton and {sup 3}He targets will be used to extract the four spin-polarizabilities of the nucleons with accuracies ranging from 5-to-25%. These values will be compared to the predictions of Chiral Perturbation Theory and anticipated results from Lattice QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ASSEMBLY, INSTALLATION, AND COMMISSIONING OF THE ATLAS UPGRADE CRYOMODULE

A new cryomodule containing seven low-beta superconducting radio frequency (SRF) cavities has been added to the ATLAS heavy ion linac, providing an additional 15 MV accelerating potential to the existing accelerator. We describe the final stages of cryomodule assembly, commissioning, and installation in the ATLAS accelerator. The clean techniques used to achieve low-particulate rf surfaces are presented, as are the module design features which enable clean assembly and reliable high-gradient operation. The thermal performance of the cryomodule is described, along with performance data for the SRF cavities. Details on subsystem performance including helium and nitrogen systems, vacuum systems, thermal and magnetic shields, slow and fast tuners, and survey/alignment systems are given.

43 PARTICLE ACCELERATORS↗

Upgrade of the lithium beam diagnostic at JET

A 60 kV neutral Li beam is injected into the edge plasma of JET to measure the electron density. The beam observation system has been improved by replacing a Czerny-Turner spectrometer with a high-resolution transmission-grating spectrometer and a fast back-illuminated frame-transfer camera. The larger throughput of the spectrometer, the increased sensitivity, and the faster readout of the new camera allow inter-ELM (edge localized mode) measurements (frame rate of 100 Hz). The calibration of the setup, as well as an improved spectral fitting technique in the presence of carbon background radiation, is discussed in detail. The density calculation is based on a statistical analysis method. Results are presented for different plasma scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗