Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing tank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Surface tension propellant acquisition system technology for Space Shuttle reaction control tanks

A program was conducted to provide the technology base for the SS/RCS flight tankage. Through a combination of analysis, subscale testing and computer predictions, a surface tension acquisition/expulsion system design was developed for the Orbiter RCS application. A full-scale tank system was fabricated and ground verification testing was conducted. Cleaning, inspection, fill and drain, and one-g expulsion performance were demonstrated. Results show that the fine-mesh screen, compartmented tank system provides the performance, flexibility, reusability, and other characteristics required by the pulsing, high flowrate RCS. It provides the required expulsion under widely differing high-g boost abort and reentry vectors oriented 119 deg apart and during on-orbit operation under omnidirectional low-g conditions.

Fester, D. A.↗

Results from the interim salt disposition program macrobatch 10 tank 21 H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). This document reports characterization data on the samples of Tank 21H and fulfills the requirements of Deliverable 3 of the Technical Task Request (TTR). Further work will report the results of the Extraction-Scrub-Strip (ESS) testing (Task 5 of the TTR) using the Tank 21H material. Task 4 of the TTR (MST Strike) will not be completed for Salt Batch 10.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid propellant thermal conditioning system test program

Results are presented from more than 1500 hours of testing on a liquid hydrogen thermal conditioning unit. Test parameters included: mixer and vent flow rates; tank size; ullage volume; pressurant gas; pressurant temperature; pressure level; and heat rate. Gaseous hydrogen and helium were used as pressurants. Analytical models were developed to correlate the test data and relate the performance to that anticipated in zero gravity. Experimental and theoretical results are presented which relate the variables controlling vapor condensation at a moving interface.

Bullard, B. R.↗

High Resolution Millimeter Wave Inspecting of the Orbiter Acreage Heat Tiles of the Space Shuttle

Presence of defects such as disbonds, delaminations, impact damage, in thermal protection systems can significantly reduce safety of the Space Shuttle and its crew. The physical cause of Space Shuttle Columbia's catastrophic failure was a breach in its thermal protection system, caused by a piece of external tank insulating foam separating from the external tank and striking the leading edge of the left wing of the orbiter. There is an urgent need for a rapid, robust and life-circle oriented nondestructive testing (NDT) technique capable of inspecting the external tank insulating foam as well as the orbiter's protective (acreage) heat tiles and its fuselage prior and subsequent to a launch. Such a comprehensive inspection technique enables NASA to perform life-cycle inspection on critical components of the orbiter and its supporting hardware. Consequently, NASA Marshall Space Flight Center initiated an investigation into several potentially viable NDT techniques for this purpose. Microwave and millimeter wave NDT methods have shown great potential to achieve these goals. These methods have been successfully used to produce images of the interior of various complex, thick and thin external tank insulating foam structures for real focused reflectometer at operating frequency from 50-100 GHz and for synthetic aperture techniques at Ku-band (12-18 GHz) and K-band (18-26 GHz). Preliminary results of inspecting heat tile specimens show that increasing resolution of the measurement system is an important issue. This paper presents recent results of an investigation for the purpose of detecting anomalies such as debonds and corrosion in metal substrate in complex multi-sectioned protective heat tile specimens using a real focused 150 GHz (D-band) reflectometer and wide-band millimeter wave holography at 33-50, GHz (Q-band).

Case, J. T.↗

Evaluation of Long Term Microbial Regrowth in Slosh Water Tanks From the International Space Station

The NASA Launch Services Program (LSP) maintained the SPHERES-Slosh experiment aboard the International Space Station (ISS) between 2013 and 2019. The purpose of the Slosh experiment was to examine how liquids move inside fuel tanks in a microgravity environment. These tanks were similar to water storage tanks planned for use aboard future space systems, where large dormant periods between crew-use will provide similar conditions for biological growth or chemical leaching. The water within the SLOSH tanks remained undisturbed for over five years after testing concluded, providing a unique sample for stored water under microgravity conditions without prior protocols for microbial control such as sterilization or addition of biocides. The Slosh storage tanks were returned to Kennedy Space Center (KSC) aboard SpaceX CRS-18 mission in November 2019. Upon return of the tanks, the water within each tank was analyzed to determine how the water chemistry and biology changed during its tenure in microgravity. The data obtained and described within this publication provided a basis and reasoning for planning water storage and purification treatment methods aboard ISS, Gateway, and future space habitats. Results demonstrated that low microbial concentrations were present within the water, as expected since no biocide treatment was employed, yet no extensive biofilm formation was observed after 5 years even in the presence of microbial food sources such as the polycarbonate structure and food color additives. This experimentation demonstrates that future biofilm studies should be performed on this type of experimental setup with proper controls aboard ISS to examine microbial regrowth to improve microbial control within space water systems.

Luke B. Roberson↗

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 AND MCU-11-319

Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 and MCU-11-319 are reported. The results show that the solvent at MCU does not require an Isopar{reg_sign} L addition, but it will require addition of trioctylamine. Cesium mass transfer testing with the solvent matches expected extraction behavior but shows a slightly lower stripping efficiency than seen in the original process demonstration for Macrobatch 3. The entrained aqueous solution indicates the scrub wash is significantly out of specification. As a result, the facility replaced the scrub wash. Unlike the previous solvent sample results, these analyses indicate that the solvent does not require minor Isopar{reg_sign} L trimming at this time. However, addition of TOA is warranted. These findings indicate that the new protocols for solvent monitoring and control are yielding favorable results. Nevertheless, the deviation in the TOA concentration since the last analysis indicates continued periodic (i.e., quarterly) monitoring is recommended. The {sup 137}Cs mass transfer results from the solvent sample testing show possible evidence of slightly reduced stripping efficiency. An evaluation (using a model) of expected system performance for MCU using the measured distribution values predicts an {approx}50% decline in DFs given the ESS test results. The customer should consider pulling a SHT sample for reanalysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Iodine Speciation Effects in LAW Feeds

Tests were conducted on a DM10 vitrification system with prototypical off-gas treatment system, which includes an SBS, WESP, and evaporator based on the design of the evaporator to be installed at the WTP for concentration of the liquid effluents. This allowed determination of the partitioning and speciation of iodine between the melter and the off gas system components, including liquid effluents from the SBS and WESP as well as in the evaporator condensate and concentrate. Evaporator testing was decoupled from melter testing to permit filtration and pH adjustments of process solutions prior to evaporation. In addition, a slip stream was pulled from the exhaust downstream of the WESP and High-Efficiency Particulate Air (HEPA) filters and passed through a caustic scrubber simulating the WTP caustic scrubber to assess iodine partitioning to the caustic scrubber liquid effluent. The tests were conducted using simulated Hanford LAW from tank AP-107, which is the planned first feed for Direct Feed LAW (DFLAW) operations, at a nominal feed concentration of 5.6 molar Na over about 120 hours of testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Return to Flight Resource Reel 2 of 2

A continuation of the tests performed on the Space Shuttle Discovery in preparation for its return to flight is presented. The tests include: 1) Shuttle Robot Arm Recertification; 2) Michael Hiltz Systems Group Leader; 3) Orbiter Boom Fabrication; 4) Orbiter Boom Final Development; 5) Gary Searle Manager of Orbiter Boom Sensor System (OBSS) Manufacturing and Assembly; 6) Orbiter Boom Qualification Unit; 7) STS-114 Crew Inspects Orbiter Boom at Kennedy Space Center; 8) Orbiter Boom Inspection of Thermal Protection System Animation; 9) External Tank Bipod Redesign; 10) External Tank Flange Redesign; 11) External Tank Bellows Redesign; 12) Shuttle Main Engine Testing and Delivery to Kennedy Space Center; 13) Ronnie Rigney Project Manager Space Shuttle Main Engine Program Office; 14) Gene Goldmman NASA Project Manager Space Shuttle Main Engine Project; 15) Mike Cosgrove Boeing-Rocketdyne Flow Manager; 16) Shuttle Rocket Booster Build-Up; 17) Ascent Imagery Improvements; and 18) STS-114 Flight Control Team and Mission Management Team.

Source record↗

Qualification of the Nippon Instrumentation for use in Measuring Mercury at the Defense Waste Processing Facility

The Nippon Mercury/RA-3000 system installed in 221-S M-14 has been qualified for use. The qualification was a side-by-side comparison of the Nippon Mercury/RA-3000 system with the currently used Bacharach Mercury Analyzer. The side-by-side testing included standards for instrument calibration verifications, spiked samples and unspiked samples. The standards were traceable back to the National Institute of Standards and Technology (NIST). The side-by-side work included the analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt, SRAT Product, and Slurry Mix Evaporator (SME) samples. With the qualification of the Nippon Mercury/RA-3000 system in M-14, the DWPF lab will be able to perform a head to head comparison of a second Nippon Mercury/RA-3000 system once the system is installed. The Defense Waste Processing Facility (DWPF) analyzes receipt and product samples from the Sludge Receipt and Adjustment Tank (SRAT) to determine the mercury (Hg) concentration in the sludge slurry. The SRAT receipt is typically sampled and analyzed for the first ten SRAT batches of a new sludge batch to obtain an average Hg concentration. This average Hg concentration is then used to determine the amount of steam stripping required during the concentration/reflux step of the SRAT cycle to achieve a less than 0.6 wt% Hg in the SRAT product solids. After processing is complete, the SRAT product is sampled and analyzed for mercury to ensure that the mercury concentration does not exceed the 0.45 wt% limit in the Slurry Mix Evaporator (SME). The DWPF Laboratory utilizes Bacharach Analyzers to support these Hg analyses at this facility. These analyzers are more than 10 years old, and they are no longer supported by the manufacturer. Due to these difficulties, the Bacharach Analyzers are to be replaced by new Nippon Mercury/RA-3000 systems. DWPF issued a Technical Task Request (TTR) for the Savannah River National Laboratory (SRNL) to assist in the qualification of the new systems. SRNL prepared a task technical and quality assurance (TT&QA) plan that outlined the activities that are necessary and sufficient to meet the objectives of the TTR. In addition, TT&QA plan also included a test plan that provided guidance to the DWPF Lab in collecting the data needed to qualify the new Nippon Mercury/RA-3000 systems.

47 OTHER INSTRUMENTATION↗

Umbilical Connect Techniques Improvement-Technology Study

The objective of this study was to develop concepts, specifications, designs, techniques, and procedures capable of significantly reducing the time required to connect and verify umbilicals for ground services to the space shuttle. The desired goal was to reduce the current time requirement of several shifts for the Saturn 5/Apollo to an elapsed time of less than one hour to connect and verify all of the space shuttle ground service umbilicals. The study was conducted in four phases: (1) literature and hardware examination, (2) concept development, (3) concept evaluation and tradeoff analysis, and (4) selected concept design. The final product of this study was a detail design of a rise-off disconnect panel prototype test specimen for a LO2/LH2 booster (or an external oxygen/hydrogen tank for an orbiter), a detail design of a swing-arm mounted preflight umbilical carrier prototype test specimen, and a part 1 specification for the umbilical connect and verification design for the vehicles as defined in the space shuttle program.

Valkema, Donald C.↗

Evaluation of Gas Retention in Waste Simulants: Intermediate-Scale Column and Open-Channel-Depth Tests

Gas generation in Hanford’s radioactive waste storage tanks can lead to gas accumulation within the layer of settled solids (sludge) at the tank bottom. The gas, which may be hazardous and/or flammable, is formed principally by radiation-driven chemical reactions. Accumulation of these gases within the sludge increases the sludge-layer volume, which decreases the available tank volume for waste storage. Further, accumulation of large amounts of gas in the sludge can potentially result in a relatively rapid release of the accumulated gas if the sludge-layer density is reduced to less than that of the overlying sludge or that of the supernatant liquid. The potential for rapid release of large amounts of hazardous and/or flammable gases is a safety hazard that needs to be managed. Accordingly, a thorough understanding is needed of the circumstances that can lead to problematic gas accumulation in sludge layers. The Deep-Sludge Gas Release Event Project (DSGREP) is tasked with developing an improved understanding of these gas release events.

Gas retention↗

Final Report of Tank 241-C-105 Dissolution, the Phase 2 Study

Three clamshell grab samples were taken from Tank 241-C-105 in October 2015 in accordance with RPP-PLAN-60011. Analytical results of those samples were issued in the report RPP-RPT-59115 by Wastren Advantage, Inc., Hanford Laboratory. Solid phase characterization results were reported separately in LAB-RPT-15-00011 and in RPP-RPT-59147. The major solid phases reported to be present were dawsonite [NaAlCO 3 (OH) 2 ], trona [Na 3 (HCO 3 )(CO 3 )·2H 2 O], cejkaite [Na 4 (UO 2 )(CO 3 ) 3 ], and an unidentified organic solid, with minor amounts of gibbsite [Al(OH) 3 ], natrophosphate [Na 7 F(PO 4 ) 2 ·19H 2 O], and traces of unidentified iron-rich and manganese-rich phases. Note that the presence of dawsonite, trona, and cejkaite requires a relatively low pH, likely around pH 9 to 10. One aliquot of each grab sample was provided to 222-S Laboratory Process Chemistry for dissolution studies. Phase 1 of the dissolution testing followed the approved test plan, WRPS-1404813, Rev. 3, and examined the behavior of the Tank 241-C-105 solids treated with water, 19M sodium hydroxide, 2M nitric acid, and 0.5M oxalic acid/2M nitric acid. Phase 2 of the testing was conducted in accordance with instructions from the client and emphasized treatment with 19M sodium hydroxide followed by water washing. This is the report of the Phase 2 testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of investigations on a 0.010-scale model of the configuration 3 space shuttle orbiter and external tank in the NASA/Ames Research Center 3.5-foot hypersonic wind tunnel (IA15)

Experimental aerodynamic investigations were conducted in a 3.5-foot hypersonic wind tunnel. The model used for this test was a 0.010-scale of the Configuration 2 Space Shuttle Orbiter and the External Tank. Six-component aerodynamic force and moment data were recorded over an angle of attack range from -8 deg to +30 deg at 0 deg and 5 deg angles of sideslip. Data was also recorded during beta sweeps of -8 deg to +10 deg at angles of attack of -10 deg, 0 deg, and 30 deg. All testing was done at Mach 7.3. Various elevon, rudder and orbiter to external tank attaching structures and fairings were tested to determine longitudinal and lateral-directional stability characteristics. Non-metric exhaust plumes were installed during a portion of the testing to determine the effects of the main propulsion system rocket plumes.

Petrozzi, M. T.↗

Scaling solid resuspension and sorption for the small column ion exchange processing tank

The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing 1.3 million gallon waste tank (i.e., Tank 41H) to house the process. Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for suspending and resuspending Monosodium Titanate (MST), Crystalline Silicotitanate (CST), and simulated sludge. In addition, SRNL will also be conducting pilot-scale tests to determine the mixing requirements for the strontium and actinide sorption. As part of this task, the results from the pilot-scale tests must be scaled up to a full-scale waste tank. This document describes the scaling approach. The pilot-scale tank is a 1/10.85 linear scale model of Tank 41H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 41H. The pump locations correspond to the proposed locations in Tank 41H by the SCIX Program (Risers B5 and B2 for two pump configurations and Risers B5, B3, and B1 for three pump configurations). MST additions are through Riser E1, the proposed MST addition riser in Tank 41H. To determine the approach to scaling the results from the pilot-scale tank to Tank 41H, the authors took the following approach. They reviewed the technical literature for methods to scale mixing with jets and suspension of solid particles with jets, and the technical literature on mass transfer from a liquid to a solid particle to develop approaches to scaling the test data. SRNL assembled a team of internal experts to review the scaling approach and to identify alternative approaches that should be considered.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spray Bar Zero-Gravity Vent System for On-Orbit Liquid Hydrogen Storage

During zero-gravity orbital cryogenic propulsion operations, a thermodynamic vent system (TVS) concept is expected to maintain tank pressure control without propellant resettling. In this case, a longitudinal spray bar mixer system, coupled with a Joule-Thompson (J-T) valve and heat exchanger, was evaluated in a series of TVS tests using the 18 cu m multipurpose hydrogen test bed. Tests performed at fill levels of 90, 50, and 25 percent, coupled with heat tank leaks of about 20 and 50 W, successfully demonstrated tank pressure control within a 7-kPa band. Based on limited testing, the presence of helium constrained the energy exchange between the gaseous and liquid hydrogen (LH2) during the mixing cycles. A transient analytical model, formulated to characterize TVS performance, was used to correlate the test data. During self-pressurization cycles following tank lockup, the model predicted faster pressure rise rates than were measured; however, once the system entered the cyclic self-pressurization/mixing/venting operational mode, the modeled and measured data were quite similar. During a special test at the 25-percent fill level, the J-T valve was allowed to remain open and successfully reduced the bulk LH2 saturation pressure from 133 to 70 kPa in 188 min.

Hastings, L. J.↗

Design of a horizontal test cryostat for superconducting RF cavities for the FREIA facility at Uppsala University

Uppsala University is constructing a large scale facility, called FREIA (Facility for Research Instrumentation and Accelerator Development). FREIA includes a helium liquefier and an accelerator test facility and has the capacity to test superconducting radio-frequency (RF) cavities with the same RF system and RF power level as in an accelerator. A central element of FREIA is a horizontal test cryostat connected in closed loop to a helium liquefier. This cryostat can house two fully equipped (tuners, piezo, power coupler, helium tank) superconducting cavities to perform full RF high power tests and operate at temperatures between 1.8 K and 4.2 K. The cryostat is designed to accommodate a large array of superconducting cavities and magnets, among which the European Spallation Source (ESS) type spoke and high-β elliptical cavities as well as TESLA/ILC type elliptical cavities. The present status of the project and the design of the cryostat are reported.

43 PARTICLE ACCELERATORS↗

Crystalline Silicotitanate ion exchange media long-term storage evaluation

Crystalline Silicotitanate a (CST) ion exchange media is produced in an engineered form, known as IONSIV™ IE-911. This material has been tested extensively for use in removing 137 Cs from Savannah River Site (SRS) and Hanford site tank waste. This inorganic material is highly selective for removing cesium ions, even in the presence of high concentrations of sodium and potassium ions and is tolerant of the harsh conditions of the varying tank chemistries. A batch of caustic washed IE-911 that had been produced by the supplier and received at SRS in 2001 was tested to verify that it was still in good condition after the extended storage. This testing involved standard batch contacts to measure the removal of Cs from simulated tank waste. This report describes the results of testing performed to verify that the IE-911 matches the performance of previous batches of this media. To confirm that the performance of IE-911 is similar to previous batches and that no degradation had occurred during storage, batch contact testing was performed using SRNL’s standard methodology using a non-radioactive SRS Average Waste Simulant composition utilized in previous studies. Batch contact kinetics testing was also conducted to determine cesium loading on this batch versus time. The cesium equilibrium loading isotherm in SRS simulant at 23°C was compared to ZAM isotherm model predictions and previous test results with IE-911 media. The measured and predicted distribution coefficients and cesium loading (“Q”) are shown in Table ES-1. The physical properties of the material were also determined, including density, moisture content, and particle size.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗