Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Halo effective field theory analysis of one-neutron knockout reactions of Be 11 and C 15

Background: One-nucleon knockout reactions provide insightful information on the single-particle structure of nuclei. When applied to one-neutron halo nuclei, they are purely peripheral, suggesting that they could be properly modeled by describing the projectile within a halo effective field theory (halo-EFT). Purpose: We reanalyze the one-neutron knockout measurements of 11 Be and 15 C —both one-neutron halo nuclei—on beryllium at about 60 MeV/nucleon. We consider halo-EFT descriptions of these nuclei which already provide excellent agreement with breakup and transfer data. Method: Here we include a halo-EFT description of the projectile within an eikonal-based model of the reaction and compare its outcome to existing data. Results: Excellent agreement with experiment is found for both nuclei. The asymptotic normalization coefficients inferred from this comparison confirm predictions from ab initio nuclear-structure calculations and values deduced from transfer data. Conclusions: Halo-EFT can be reliably used to analyze one-neutron knockout reactions measured for halo nuclei and test predictions from state-of-the-art nuclear structure models on these experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hyper Suprime-Cam Year 3 results: Cosmology from cosmic shear power spectra

Here, we measure weak lensing cosmic shear power spectra from the 3-year galaxy shear catalog of the Hyper Suprime-Cam (HSC) Subaru Strategic Program imaging survey. The shear catalog covers 416 deg 2 of the northern sky, with a mean i-band seeing of 0.59 arcsec and an effective galaxy number density of 15 arcmin —2 within our adopted redshift range. With an i-band magnitude limit of 24.5 mag, and four tomographic redshift bins spanning 0.3 ≤ z ph ≤ 1.5 based on photometric redshifts, we obtain a high-significance measurement of the cosmic shear power spectra, with a signal-to-noise ratio of approximately 26.4 in the multipole range 300 < ℓ < 1800. The accuracy of our power spectrum measurement is tested against realistic mock shear catalogs, and we use these catalogs to get a reliable measurement of the covariance of the power spectrum measurements. We use a robust blinding procedure to avoid confirmation bias, and model various uncertainties and sources of bias in our analysis, including point spread function systematics, redshift distribution uncertainties, the intrinsic alignment of galaxies and the modeling of the matter power spectrum. For a flat Λ CDM model, we find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = ${0.776}_{—0.033}^{+0.032}$, which is in excellent agreement with the constraints from the other HSC Year 3 cosmology analyses, as well as those from a number of other cosmic shear experiments. This result implies a ~2σ-level tension with the Planck 2018 cosmology. We study the effect that various systematic errors and modeling choices could have on this value, and find that they can shift the best-fit value of S 8 by no more than ~ 0.5σ, indicating that our result is robust to such systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Fixed scale approach to equation of state in lattice QCD

A new approach to study the equation of state in finite-temperature QCD is proposed on the lattice. Unlike the conventional method in which the temporal lattice size N{sub t} is fixed, the temperature T is varied by changing N{sub t} at the fixed lattice scale. The pressure of the hot QCD plasma is calculated by the integration of the trace anomaly with respect to T at the fixed lattice scale. This ''T-integral method'' is tested in quenched QCD on isotropic and anisotropic lattices and is shown to give reliable results, especially at intermediate and low temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality Assessment of GPU Power Profiling Mechanisms

Accurate component-level power measurements are nowadays essential for the design and optimization of high-performance computing (HPC) systems and applications. Particularly, as more and more heterogeneous HPC systems are developed, the characterizations of GPU power profiles have become extremely crucial because, although GPUs provide exceptional performance, they do consume substantial amounts of power. Currently, there are various GPU power profiling mechanisms available; however, there is no standard way to assess the quality of such profiling schemes. To address this issue, in this paper, we develop an assessment methodology to rate the quality and performance of the profiling mechanism itself. Specifically, we present the assessments of four different GPU power profiling techniques: (i) Nvidia's NVML via Allinea MAP, (ii) Nvidia's NVML via direct reads, and (iii) Penguin Computing's PowerInsight (PI) via two vendor-provided drivers, and (iv) PowerInsight via Allinea MAP. In addition, we discuss the effects of moving-average filters to explain the slow variations of some of the measured power profiles. Based on our assessment, the GPU power profiling mechanism using PI device outperforms the other schemes by reliably measuring the ground-truth power profile generated by a GPU stress-test benchmark.

Sen, Satyabrata↗

Resilient Communication Scheme for Distributed Decision of Interconnecting Networks of Microgrids

Networking of microgrids can provide the operational flexibility needed for the increasing number of DERs deployed at the distribution level and supporting end-use demand when there is loss of the bulk power system. But, networked microgrids are vulnerable to cyber-physical attacks and faults due to the complex interconnections. As such, it is necessary To design resilient control systems to support the operations of networked microgrids in responses to cyber-physical attacks and faults. This paper introduces a resilient communication scheme for interconnecting multiple microgrids to support critical demand, in which the interconnection decision can be made distributedly by each microgrid controller even in the presence of cyberattacks to some communication links or microgrid controllers. This scheme blends a randomized peer-to-peer communication network for exchanging information among controllers and resilient consensus algorithms for achieving reliable interconnection agreement. The network of 6 microgrids divided from a modified 123-node test distribution feeder is used to demonstrate the effectiveness of the proposed resilient communication scheme.

Vu, Thanh Long↗

Massive Contingency Analysis with High Performance Computing

Contingency analysis is a key function in the Energy Management System (EMS) to assess the impact of various combinations of power system component failures based on state estimates. Contingency analysis is also extensively used in power market operation for feasibility test of market solutions. Faster analysis of more cases is required to safely and reliably operate today’s power grids with less marginal and more intermittent renewable energy sources. Enabled by the latest development in the computer industry, high performance computing holds the promise of meet the need in the power industry. This paper investigates the potential of high performance computing for massive contingency analysis. The framework of "N-x" contingency analysis is established and computational load balancing schemes are studied and implemented with high performance computers. Case studies of massive 300,000-contingency-case analysis using the Western Electricity Coordinating Council power grid model are presented to illustrate the application of high performance computing and demonstrate the performance of the framework and computational load balancing schemes.

Computational Load Balancing↗

Endogenizing Probabilistic Resource Adequacy Risks in Deterministic Capacity Expansion Models

In this work, we demonstrate how power system capacity expansion models can understate the stochastic effects of thermal outages when considering resource availabilities on an hourly expected value basis, yielding system designs with multiple orders of magnitude more shortfall risk than stated adequacy targets. We develop a novel approximation approach to efficiently endogenize awareness of this risk in a deterministic, linear capacity expansion framework. We compare this approach to exogenous tuning of an energy reserve margin, the leading alternative method to compensate for unmodeled probabilistic shortfall risk. Empirical results from a test system show that the new endogenous method cost-effectively meets all regional reliability targets with a single optimization solve, and produces a near-identical system design as the incumbent method without the need for repeated re-optimizations to find an appropriate reserve level. The endogenous method may also use iterative re-optimizations to further improve solution quality, although these incremental benefits were modest in the system studied.

capacity expansion modeling↗

Examination of an optical transmittance test for photovoltaic encapsulation materials

The optical transmittance of encapsulation materials is a key characteristic for their use in photovoltaic (PV) modules. Changes in transmittance with time in the field affect module performance, which may impact product warranties. Transmittance is important in product development, module manufacturing, and field power production (both immediate and long-term). Therefore, an international standard (IEC 62788-1-4) has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the optical performance of PV encapsulation materials. Existing standards, such as ASTM E903, are general and more appropriately applied to concentrated solar power than to PV. Starting from the optical transmittance measurement, the solar-weighted transmittance of photon irradiance, yellowness index (which may be used in aging studies to assess durability), and ultraviolet (UV) cut-off wavelength may all be determined using the proposed standard. The details of the proposed test are described. The results of a round-robin experiment (for five materials) conducted at seven laboratories to validate the test procedure using representative materials are also presented. For example, the Encapsulation Group actively explored the measurement requirements (wavelength range and resolution), the requirements for the spectrophotometer (including the integrating sphere and instrument accessories, such as a depolarizer), specimen requirements (choice of glass-superstrate and -substrate), and data analysis (relative to the light that may be used in the PV application). The round-robin experiment identified both intra- and inter-laboratory instrument precision and bias for five encapsulation materials (encompassing a range of transmittance and haze-formation characteristics).

14 SOLAR ENERGY↗

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

PG&E WaveConnect Program (Final Report)

The PG&E WaveConnect project was intended to demonstrate the technical and economic viability of wave power in the open ocean adjacent to PG&E's service territory. WaveConnect was conceived as a multi-stage development process leading to long-term megawatt-scale wave power production. The first-stage tasks consisted of site selection, permitting, pilot plant design, and assessment of technology and commercial readiness. The second stage would have included development of infrastructure, undersea cabling, and deployment of wave energy conversion devices (WECs). In the third stage, the most promising WEC devices would have been deployed in larger quantities and connected to the grid. This report documents the findings of Stage One. Site Selection: After studying the wave energy potential, grid interconnection and other project infrastructure along the California coast, PG&E selected two sites: one near Eureka, called the Humboldt WaveConnect (HWC) project, and another near Vandenberg Air Force Base, called the Central Coast WaveConnect project (CCWC).

16 TIDAL AND WAVE POWER↗

Pecan Street Smart Grid Extension Service at the University of Texas

Through funding from the Department of Energy’s Electricity Delivery and Reliability Office, Pecan Street Inc., in partnership with Austin Energy and Oncor, developed and tested third- party data access platforms and services for Green Button offerings and for other home energy use data providers. As more utilities seek to offer Green Button-compliant data to their customers, the question continually arises of how this data can be used to help customers better manage their energy use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SSL Luminaire with Novel Driver Architecture

Cree has developed a new high-efficiency light emitting diode (LED) technology platform capable of providing low-cost, high performance luminaires that can be adopted across a variety of SSL applications. This development is built on Cree’s high brightness LED platform to design a novel LED chip that enables a high-efficiency driver architecture to improve the overall luminaire system efficacy. These system efficiency gains were realized using an integrated approach tailoring the LED chip characteristics to allow for the high-efficiency driver technology platform. The reliability of the new LED design was robust at the component level under accelerated testing conditions. Luminaires were assembled integrating the novel LED and driver technology to demonstrate the system improvement. Cree has successfully completed this project by developing a novel LED architecture that enables a new driver design with 93% efficiency. This technology was showcased in an LED luminaire that produced 725 lumens at an efficacy of 87.4 lumens per watt (LPW). The correlated color temperature (CCT) of the luminaire was 2708 K with a color rendering index (CRI) of 91. The novel LEDs and driver led to a 9% system performance improvement compared to the standard LEDs and driver scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Power Technologies Office: Multi-Year Program Plan

The U.S. Department of Energy’s Water Power Technologies Office (WPTO) has released its first Multi-Year Program Plan (MYPP), which outlines the Office’s research priorities and plans through 2025. Cover of the WPTO MYPP 2022. The MYPP serves as both a strategic vision and an operational guide to help WPTO manage and coordinate its activities, as well as a vehicle to communicate WPTO’s mission, goals, and plans to water power stakeholders and the public. It details WPTO’s research, development, demonstration, and commercial activities across both hydropower and marine energy for the coming years and outlines how these efforts can help meet the nation’s energy and sustainability goals. The MYPP features key performance goals for 2025, as well as additional objectives running through 2030. All outlined goals contribute to the overarching mission of WPTO to enable research, development, and testing of new technologies to advance marine energy and hydropower systems for a flexible, reliable grid.

13 HYDRO ENERGY↗

Thermo-Mechanical Modeling and Evaluation of the Cracking Response of Additively Manufactured Monolithic SiC Lattice Structures Subjected to Laser Heating

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Owing to its high temperature stability combined with excellent thermal and optical properties, SiC has been the material of choice for application in high-temperature solar receivers. The state-of-the-art SiC volumetric concentrating solar air receivers such as honeycomb design have been demonstrated in field tests to achieve exit air temperatures approaching 800oC. However, successful application of CST systems for decarbonization requires significant increase in temperature capability of SiC receiver technology. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to design and to demonstrate a techno-economically viable SiC air receiver technology to achieve exit air temperature of 1100oC for CST applications. This report summarizes the learnings of a computational study on additively manufactured SiC lattice structures subjected to laser heating. The results from this study aim to help guide the design of a SiC receiver through a better understanding of lattice structure geometric parameters and their implications on the cracking response of the structure. In the study, a heat flux was applied to the surface of a 2”-diameter cylindrical lattice structure to simulate a 4kW CO2 laser. The resulting temperature distribution was applied to a structural model to approximate the stress distribution within the lattice structure and a Weibull analysis was performed to gain insight into the probability of failure and to evaluate the cracking response of the structure. With this approach, the influence of lattice density on temperature, stress, and probability of failure was explored for two different lattice beam spacings. A discussion on modeling assumptions, a comparison with experimental results, and an evaluation of the lattice cracking response is provided.

14 SOLAR ENERGY↗

Smart distribution systems

The increasing importance of system reliability and resilience is changing the way distribution systems are planned and operated. To achieve a distribution system self-healing against power outages, emerging technologies and devices, such as remote-controlled switches (RCSs) and smart meters, are being deployed. The higher level of automation is transforming traditional distribution systems into the smart distribution systems (SDSs) of the future. The availability of data and remote control capability in SDSs provides distribution operators with an opportunity to optimize system operation and control. In this paper, the development of SDSs and resulting benefits of enhanced system capabilities are discussed. A comprehensive survey is conducted on the state-of-the-art applications of RCSs and smart meters in SDSs. Specifically, a new method, called Temporal Causal Diagram (TCD), is used to incorporate outage notifications from smart meters for enhanced outage management. To fully utilize the fast operation of RCSs, the spanning tree search algorithm is used to develop service restoration strategies. Optimal placement of RCSs and the resulting enhancement of system reliability are discussed. Distribution system resilience with respect to extreme events is presented. Furthermore, test cases are used to demonstrate the benefit of SDSs. Active management of distributed generators (DGs) is introduced. Future research in a smart distribution environment is proposed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Suggestions for better election security.

Summary of Common Security Mistakes: (1) Electronic voting machines that fundamentally lack security thought and features, including an ability to detect tampering or intrusion, or to be reliably locked or sealed; (2) Failure to disassemble, inspect, and thoroughly inspect (not just test) a sufficient number of voting machines before and after elections in order to detect hardware or software tampering; (3) Assuming that tamper - indicating seals will either be blatantly ripped/smashed open, or else there is no tampering. In reality, even amateurs can spoof most seals leaving (at most) subtle evidence; (4) Inadequate seal use protocols and training of seal installers and inspectors. Failure to show examples of blatantly and subtly attacked seals to seal inspectors; (5) Over confidence in use of a voter verified paper record (VVPR), a VVPR is an excellent security countermeasure, but it is not a silver bullet, especially for an election organization with poor overall security; (6) Little or no insider thr at mitigation; and (7) A poor security culture, including denial and no a priori procedures for dealing with security questions or concerns.

99 GENERAL AND MISCELLANEOUS↗

Safety Related Concerns with Installation and Use of Switch-Rated Plug/Receptacle Combinations in Lieu of Metal-Enclosed Disconnect Switches

The manufacturers of Nationally Recognized Testing Laboratory (NRTL) listed, switch-rated, plug and receptacle combinations tout their convenience, reliability, efficiency, and compliance with both the National Fire Protection Association (NFPA) 70®, National Electric Code (NEC), and National Fire Protection Association 70E®, The Standard for Electrical Safety in the Workplace, as advantages to using these products in lieu of traditional metal-enclosed disconnect switches. The purpose of this paper is to raise awareness of several unintended consequences that can result when replacement involves high energy cord and plug connected equipment. This paper describes several possible issues in complying with the NFPA 70 Articles 110 and 400 and NFPA 70E Articles 110 and 130 that should be considered when using load rated plug/receptacle combinations. This paper is intended to address high energy circuits typically associated with 480 volt pin and sleeve type connections in applications where incident energy levels may exceed 1.2 calories/centimeter² (cal/cm²).

99 GENERAL AND MISCELLANEOUS↗