Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Hierarchical Model Reduction Driven by Machine Learning for Parametric Advection-Diffusion-Reaction Problems in the Presence of Noisy Data

Abstract We propose a new approach to generate a reliable reduced model for a parametric elliptic problem, in the presence of noisy data. The reference model reduction procedure is the directional HiPOD method, which combines Hierarchical Model reduction with a standard Proper Orthogonal Decomposition, according to an offline/online paradigm. In this paper we show that directional HiPOD looses in terms of accuracy when problem data are affected by noise. This is due to the interpolation driving the online phase, since it replicates, by definition, the noise trend. To overcome this limit, we replace interpolation with Machine Learning fitting models which better discriminate relevant physical features in the data from irrelevant unstructured noise. The numerical assessment, although preliminary, confirms the potentialities of the new approach.

97 MATHEMATICS AND COMPUTING↗

Automated Voxel-Based Analysis of Volumetric Dynamic Contrast-Enhanced CT Data Improves Measurement of Serial Changes in Tumor Vascular Biomarkers

Objectives: Development of perfusion imaging as a biomarker requires more robust methodologies for quantification of tumor physiology that allow assessment of volumetric tumor heterogeneity over time. This study proposes a parametric method for automatically analyzing perfused tissue from volumetric dynamic contrast-enhanced (DCE) computed tomography (CT) scans and assesses whether this 4-dimensional (4D) DCE approach is more robust and accurate than conventional, region-of-interest (ROI)-based CT methods in quantifying tumor perfusion with preliminary evaluation in metastatic brain cancer. Methods and Materials: Functional parameter reproducibility and analysis of sensitivity to imaging resolution and arterial input function were evaluated in image sets acquired from a 320-slice CT with a controlled flow phantom and patients with brain metastases, whose treatments were planned for stereotactic radiation surgery and who consented to a research ethics board-approved prospective imaging biomarker study. A voxel-based temporal dynamic analysis (TDA) methodology was used at baseline, at day 7, and at day 20 after treatment. The ability to detect changes in kinetic parameter maps in clinical data sets was investigated for both 4D TDA and conventional 2D ROI-based analysis methods. Results: A total of 7 brain metastases in 3 patients were evaluated over the 3 time points. The 4D TDA method showed improved spatial efficacy and accuracy of perfusion parameters compared to ROI-based DCE analysis (P<.005), with a reproducibility error of less than 2% when tested with DCE phantom data. Clinically, changes in transfer constant from the blood plasma into the extracellular extravascular space (K{sub trans}) were seen when using TDA, with substantially smaller errors than the 2D method on both day 7 post radiation surgery (±13%; P<.05) and by day 20 (±12%; P<.04). Standard methods showed a decrease in K{sub trans} but with large uncertainty (111.6 ± 150.5) %. Conclusions: Parametric voxel-based analysis of 4D DCE CT data resulted in greater accuracy and reliability in measuring changes in perfusion CT-based kinetic metrics, which have the potential to be used as biomarkers in patients with metastatic brain cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical Verification of Equilibrium Thermodynamic Computations in Nuclear Fuel Performance Codes

There is an increasing desire to integrate thermodynamic computations directly into multi-physics nuclear fuel performance and safety codes. These computations provide, among other matters, boundary conditions in heat and mass transport modules in predicting fuel behaviour. Precision must be maintained in computations involving fission and activation products with very low concentrations which may nonetheless have significant radiological consequences. Also, there is the concern about the propagation of numerical errors in multi-physics codes. A method to numerically verify equilibrium thermodynamic computations is therefore necessary to satisfy rigorous quality assurance standards of the nuclear industry without significantly impeding computational performance. A technique is presented that can be applied to systems of any number of phases and system components. The technique is reliable and comprehensive in ensuring that all conceivable equilibrium constants have been satisfied without having to formulate each one of a potentially very large number.

Piro, Markus↗

Assessment of NDE for Key Indicators of Aging Cables in Nuclear Power Plants – Interim Status

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program to justify cable performance under normal operation as well as accident conditions. Currently the gold standard for determining cable insulation degradation is the elongation-at-break (EAB). This, however, is an ex-situ measurement and requires removal of a sample for laboratory investigation. A reliable nondestructive examination (NDE) in-situ approach is desirable to objectively determine the suitability of the cable for service. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none of these tests are suitable for all cable configurations nor does any single test confirm all features of interest. Nevertheless, the complete collection of test possibilities offers a powerful range of tools to assure the integrity of critical cables. Licensees and regulators have settled on a practical program to justify continued operation based on condition monitoring of a lead sample set of cables where test data is tracked in a database and the required test data are continually adjusted based on plant and fleet-wide experience. As part of the Light Water Reactor Sustainability program sponsored by the U.S. Nuclear Regulatory Commission, the U.S. Department of Energy, and industry (represented by the Electric Power Research Institute), an assessment of cable NDE methods was commissioned. Technologies include both bulk electrical measurements (Tan d, time domain reflectometry, frequency domain reflectometry (FDR), partial discharge, and other techniques) and local insulation measurement (indenter, dynamic mechanical analysis interdigital capacitance, infrared spectral measurement, etc.). This aging cable NDE program update reviews the full range of techniques but focuses on the most interesting test approaches that have a chance to be deployed in-situ, particularly including Tan d, FDR, and ultrasound methods that have been reviewed most completely in this progress period.

cable aging inspection↗

The level-1 trigger for the SuperCDMS experiment at SNOLAB

The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to Script O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, σn, and a 99.9% trigger efficiency for signal amplitudes of 1.1 σ n in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Abstract Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ2 method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ2 method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ2 method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

79 ASTRONOMY AND ASTROPHYSICS↗

Shape of primordial non-Gaussianity and the CMB bispectrum

We present a set of formalisms for comparing, evolving, and constraining primordial non-Gaussian models through the CMB bispectrum. We describe improved methods for efficient computation of the full CMB bispectrum for any general (nonseparable) primordial bispectrum, incorporating a flat sky approximation and a new cubic interpolation. We review all the primordial non-Gaussian models in the present literature and calculate the CMB bispectrum up to l<2000 for each different model. This allows us to determine the observational independence of these models by calculating the cross correlation of their CMB bispectra. We are able to identify several distinct classes of primordial shapes--including equilateral, local, warm, flat, and feature (non-scale invariant)--which should be distinguishable given a significant detection of CMB non-Gaussianity. We demonstrate that a simple shape correlator provides a fast and reliable method for determining whether or not CMB shapes are well correlated. We use an eigenmode decomposition of the primordial shape to characterize and understand model independence. Finally, we advocate a standardized normalization method for f{sub NL} based on the shape autocorrelator, so that observational limits and errors {delta}f{sub NL} can be consistently compared for different models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Evaluation of Phasor Measurement Systems

After two decades of phasor network deployment, phasor measurements are now available at many major substations and power plants. The North American SynchroPhasor Initiative (NASPI), supported by both the US Department of Energy and the North American Electricity Reliability Council (NERC), provides a forum to facilitate the efforts in phasor technology in North America. Phasor applications have been explored and some are in today’s utility practice. IEEE C37.118 Standard is a milestone in standardizing phasor measurements and defining performance requirements. To comply with IEEE C37.118 and to better understand the impact of phasor quality on applications, the NASPI Performance and Standards Task Team (PSTT) initiated and accomplished the development of two important documents to address characterization of PMUs and instrumentation channels, which leverage prior work (esp. in WECC) and international experience. This paper summarizes the accomplished PSTT work and presents the methods for phasor measurement evaluation.

North American SynchroPhasor Initiative (NASPI)↗

SU-G-BRA-09: Estimation of Motion Tracking Uncertainty for Real-Time Adaptive Imaging

Purpose: kV fluoroscopic imaging combined with MV treatment beam imaging has been investigated for intrafractional motion monitoring and correction. It is, however, subject to additional kV imaging dose to normal tissue. To balance tracking accuracy and imaging dose, we previously proposed an adaptive imaging strategy to dynamically decide future imaging type and moments based on motion tracking uncertainty. kV imaging may be used continuously for maximal accuracy or only when the position uncertainty (probability of out of threshold) is high if a preset imaging dose limit is considered. In this work, we propose more accurate methods to estimate tracking uncertainty through analyzing acquired data in real-time. Methods: We simulated motion tracking process based on a previously developed imaging framework (MV + initial seconds of kV imaging) using real-time breathing data from 42 patients. Motion tracking errors for each time point were collected together with the time point’s corresponding features, such as tumor motion speed and 2D tracking error of previous time points, etc. We tested three methods for error uncertainty estimation based on the features: conditional probability distribution, logistic regression modeling, and support vector machine (SVM) classification to detect errors exceeding a threshold. Results: For conditional probability distribution, polynomial regressions on three features (previous tracking error, prediction quality, and cosine of the angle between the trajectory and the treatment beam) showed strong correlation with the variation (uncertainty) of the mean 3D tracking error and its standard deviation: R-square = 0.94 and 0.90, respectively. The logistic regression and SVM classification successfully identified about 95% of tracking errors exceeding 2.5mm threshold. Conclusion: The proposed methods can reliably estimate the motion tracking uncertainty in real-time, which can be used to guide adaptive additional imaging to confirm the tumor is within the margin or initialize motion compensation if it is out of the margin.

60 APPLIED LIFE SCIENCES↗

BOCC Blueprint

The Pacific Northwest National Laboratory (PNNL) Facility and Operations (F&O) Division strives to manage performance, to assure long-term health and sustainability for the organization and our staff through innovation and learning. The F&O organization is committed to achieving five strategic outcomes over the next several years. The strategic outcomes are aligned with the Department of Energy (DOE) and PNNL mission and vision. One key outcome important to enabling our vision is to integrate the smartest facilities, connected to the smartest people, by the smartest systems. We call this our SMART3 Initiative. The F&O SMART3 Initiative will connect human capital with intelligent systems, resulting in a best-in-class, integrated facility-operations strategy that improves productivity and optimizes operational costs. The Building Operations Control Center (BOCC) Blueprint is a key deliverable in this effort and will define near-term and long-term objectives aligned with the SMART3 Initiative. The BOCC Blueprint provides a plan to successfully position the BOCC and assure full integration into the new Systems Engineering Laboratory (SEL). The BOCC Blueprint near-term objectives will satisfy each of the three elements of the SMART3 Initiative. 1. The facilities element will be achieved by defining the minimum set of smart sensors for deployment, establishing dashboards and metrics, and initiating a Real-Time Commissioning Program (RT-Cx). 2. The people element will be achieved as F&O and the Energy and Environment Directorate (EED) collaborate, mentor, and cross-train within F&O. The collaboration effort will provide proof of concept by testing, applying and sharing information on facility systems through smart grid, facility re-tuning & audits, and DSOM fault detection and diagnostics. The mentoring and cross-training will be realized by integrating air balance operators, power operators and FMCS specialists within the BOCC. 3. The systems element will be achieved by standardizing the Facility Management Control Systems (FMCS) and Decision Support for Operations and Maintenance (DSOM) development, specifically by implementing facility dashboards and tools. The long-term objectives are to enhance reliability, reduce cost, and demonstrate the “Living Laboratory,” as defined by the way facilities are used to advance research from theoretical to practical applications through scientific collaboration among PNNL’s research and development (R&D) staff. With the BOCC Blueprint defining the objectives to meet the SMART3 Initiative, the BOCC will become a valuable PNNL core competency, and allow for additional R&D opportunities.

99 GENERAL AND MISCELLANEOUS↗

Tamper-Indicating Enclosures with Visually Obvious Tamper Response (Final Project Report)

Sandia National Laboratories is developing a new method for detecting penetration of tamper - indicating enclosures (TIEs). This method incorporates the use of "bleeding" materials (analogous to visually obvious, colorful bruised skin that doesn't heal) into the design of TIEs. As designed, it will allow inspectors to use simple visual observation to detect attempts to penetrate the external surfaces of a TIE, without providing adversaries the ability to repair damage. A material of this type can enhance tamper indication of current TIEs used to support treaty verification regimes. Current TIE inspections are time - consuming and rely on subjective visual assessment by an inspector, equipment such as eddy current or camera devices, or involve approaches that may be limited due to application environment. The complexities and requirements that volumetric sealing methods (or TIEs) must address are: (1) enclosures that are non - standard in size/shape; (2) enclosures that may be inspectorate - or facility - owned; (3) finding tamper attempts that are difficult and time consuming for an inspector to locate; (4) enclosures that are reliable and durable enough to survive the conditions that exist in the operating environment (including facility handling); and (5) methods that prevent adversaries from repairing penetrations. Early project R&D [1] focused on encapsulated transition metals. Due to the challenges associated with the transition metal - based approach, a mitigation approach was investigated resulting in two separate research paths — one that involves fabricating custom TIE molds that meet the specific (size and shape) needs of safeguards equipment a nd one that can be deployed as a sprayed on or painted coating to an existing TIE or surface. The "custom mold" approach is based on creating thin layers of materials that , when penetrated, expose an inner material to O 2 which causes an irreversible color change. The "in-situ coating" approach is based on applying a sensor solution containing color changing microcapsules that bleed when the microcapsule is ruptured. The anticipated benefits of this work are passive, flexible, scalable, robust , cost-effective TIEs with visually obvious responses to tamper attempts. This provides more efficient and effective monitoring , as inspectors will require little or no additional equipment and will be able to detect tamper without extensive time - consuming visual examination. Applications include custom TIEs (cabinets , equipment enclosures or seal bodies ), or spray-coating/painting onto facility-owned items, walls or structures, or circuit boards. The paper describes research and testing completed to-date on the method and integration of select system components.

36 MATERIALS SCIENCE↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659↗

Decreasing wind speed extrapolation error via domain-specific feature extraction and selection

Abstract. Model uncertainty is a significant challenge in the wind energy industry and can lead to mischaracterization of millions of dollars' worth of wind resources. Machine learning methods, notably deep artificial neural networks (ANNs), are capable of modeling turbulent and chaotic systems and offer a promising tool to produce high-accuracy wind speed forecasts and extrapolations. This paper uses data collected by profiling Doppler lidars over three field campaigns to investigate the efficacy of using ANNs for wind speed vertical extrapolation in a variety of terrains, and it quantifies the role of domain knowledge in ANN extrapolation accuracy. A series of 11 meteorological parameters (features) are used as ANN inputs, and the resulting output accuracy is compared with that of both standard log-law and power-law extrapolations. It is found that extracted nondimensional inputs, namely turbulence intensity, current wind speed, and previous wind speed, are the features that most reliably improve the ANN's accuracy, providing up to a 65 % and 52 % increase in extrapolation accuracy over log-law and power-law predictions, respectively. The volume of input data is also deemed important for achieving robust results. One test case is analyzed in depth using dimensional and nondimensional features, showing that the feature nondimensionalization drastically improves network accuracy and robustness for sparsely sampled atmospheric cases.

17 WIND ENERGY↗

Television multiplexing system

System with single, standard, wideband line transmits ten or more real time TV video data displays over hard wire to recorders more than 22.5 km from source. Digital logic and integrated circuits ensure high reliability and low maintenance. System is adaptable for video sampling applications.

Simpkins, L. G.↗

Observations of secondary spectrophotometric standards in the wavelength range between 5840 and 10800 A

Twenty-three stars that are suitable for use as secondary spectrophotometric standards are compared with Alpha Lyrae in the wavelength range between 5840 A and 1.1 microns. The consistency of the present data with previously existing measurements is discussed, along with the reliability of the present data. It is found that there is good agreement with previous data in some cases, but moderate or substantial discrepancies are exhibited in others. It is suggested that extinction variation is the most probable cause of the discrepancies, and observational procedures that may improve the situation with regard to the discrepancies are proposed.

Taylor, B. J.↗

Influence of current needs on the advancement of aluminum electrolytic capacitors

The need for cost effective, high performance, long life capacitors with improved reliability is discussed. It is shown that a low cost, miniature aluminum capacitor, with improved reliability and proven life, can be produced with existing technology. It is further shown that the capacitor can be specified for 125 C life and shelf test requirements, and meet established standards for their parametric performance.

Moresi, J. A.↗

Practical aspects of instrumentation system installation, volume 13

A review of factors influencing installation of aircraft flight test instrumentation is presented. Requirements, including such factors as environment, reliability, maintainability, and system safety are discussed. The assessment of the mission profile is followed by an overview of electrical and mechanical installation factors with emphasis on shock/vibration isolation systems and standardization of the electric wiring installation, two factors often overlooked by instrumentation engineers. A discussion of installation hardware reviews the performance capabilities of wiring, connectors, fuses and circuit breakers, and a guide to proper selections is provided. The discussion of the installation is primarily concerned with the electrical wire routing, shield terminations and grounding. Also inclued are some examples of installation mistakes that could affect system accuracy. System verification procedures and special considerations such as sneak circuits, pyrotechnics, aircraft antenna patterns, and lightning strikes are discussed.

Borek, R. W.↗