Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Evaluation of Phenylnaphthalenes as Heat Transfer Fluids for High Temperature Energy Applications

The thermodynamic properties of 1- and 2-phenyl substituted polyaromatic hydrocarbons have been measured and estimated under conditions relevant to heat transport applications almost to the critical point. Densities, vapor pressures, and heat capacity measurements were used to derive critical temperature, pressure and density for the phenylnaphthalenes. The thermal and radiolytic stability of 1-phenylnaphthalene was examined using thermogravimetric analysis, differential scanning calorimetery, and gamma irradiation. Low vapor pressure and resistance to thermal decomposition may make phenylnaphthalenes suitable for heat transfer applications involving parabolic solar collectors. In particular, 1-phenylnaphthalene has an advantage over high temperature inorganic salts for applications up to 800 K because it is a liquid at temperatures at or close to ambient. Thermal cycling would have to be restricted to temperatures below the critical point to avoid degradation of the fluid. Radiation stability was also tested by a 100 kGy irradiation of 1-phenylnaphthalene in a Co-60 irradiator. NMR analysis indicated 1.7 mol.% degradation, which although lower than observed for tributylphosphate/kerosene benchmark fluids for nuclear applications, is higher than that seen in imidazolium ionic liquids.

14 SOLAR ENERGY↗

Thermal and radiation damage to SL/1 EREP films

Tests were conducted to determine the present sensitometric characteristics of the SL/1 EREP films stored in Skylab. These films underwent the high temperature environment at the beginning of the mission and have since been stored outside the film vault. As a result, the films will have received a radiation dose estimated at approximately 12 rads by the end of SL/3.

Perry, L.↗

Scaling Global Warming Impacts on Ocean Ecosystems: Lessons From a Suite of Earth System Models

An important technique used by climate modelers to isolate the impacts of increasing greenhouse gasses on Earth System processes is to simulate the impact of an abrupt increase in carbon dioxide. The spatial pattern of change provides a “fingerprint” that is generally much larger than natural variability. Insofar as the response to radiative forcing is linear (the impact of quadrupling CO 2 is twice the impact of doubling CO 2 ) this fingerprint can then be used to estimate the impact of historical greenhouse gas forcing. However, the degree to which biogeochemical cycles respond linearly to radiative forcing has rarely been tested. In this paper, we evaluate which ocean biogeochemical fields are likely to respond linearly to changing radiative forcing, which ones do not, and where linearity breaks down. We also demonstrate that the representation of lateral mixing by mesoscale eddies, which varies significantly across climate models, plays an important role in modulating the breakdown of linearity. Globally integrated surface rates of biogeochemical cycling (primary productivity, particulate export) respond in a relatively linear fashion and are only moderately sensitive to mixing. By contrast, the habitability of the interior ocean (as determined by hypoxia and calcite supersaturation) behaves non-linearly and is very sensitive to mixing. This is because the deep ocean, as well as certain regions in the surface ocean, are very sensitive to the magnitude of deep wintertime convection. The cessation of convection under global warming is strongly modulated by the representation of eddy mixing.

54 ENVIRONMENTAL SCIENCES↗

Failure modes and low temperature performance of DC/DC converters

Several standard tests to evaluate key (direct current) DC/DC converter parameters were performed on different models of hybrid radiation-hard DC/DC converters. These tests were done to assess both performance and reliability during space applications that operate the converters at temperatures below the lower military range of -5°C. One of the converters failed near -110°C, but another DC/DC converter model started normally at temperatures as low as 140°C. The latter showed acceptable performance during turn-on, load transient, and synchronization tests even though some minor anomalies were observed. These results show good promise for its use in applications where the DC/DC converters will be operated at lower temperatures. An application circuit was also built and preliminary tests were performed on a commercial (low drop out) LDO type of DC to DC converter with adjustable output voltage. These can be used in point of load (POL) applications. This latter device functioned properly on the few tests that were performed; however, more testing is needed to identify potential issues with space use of this and similar devices.

Leon, Rosa↗

Analysis of Shockwave Radiation Data in Nitrogen

Data from test series in the Electric Arc Shock Tube Facility were previously reportedfor velocities spanning 6-12 km/s in pure N2 at a freestream pressure of 0.2 Torr. The testseries provided spectrally- and spatially-resolved data for validation of a number of modelsof physical phenomena, including vibrational relaxation, molecular radiation, nitrogendissociation and ionization, and atomic radiation and ionization. In the present workanalysis of data obtained at a nominal velocity of 10.3 km/s is discussed in detail. Spectraare analyzed to extract temperatures and the densities of excited states as a function ofposition behind the shock. The effect of different methods for calculating state populationsand ionization processes is assessed, as is a rigorous assessment of the atomic line lists, withboth missing and extra lines identified.

Re-entry↗

Heat pipe radiator

A 15,000 watt spacecraft waste heat rejection system utilizing heat pipe radiator panels was investigated. Of the several concepts initially identified, a series system was selected for more in-depth analysis. As a demonstration of system feasibility, a nominal 500 watt radiator panel was designed, built and tested. The panel, which is a module of the 15,000 watt system, consists of a variable conductance heat pipe (VCHP) header, and six isothermalizer heat pipes attached to a radiating fin. The thermal load to the VCHP is supplied by a Freon-21 liquid loop via an integral heat exchanger. Descriptions of the results of the system studies and details of the radiator design are included along with the test results for both the heat pipe components and the assembled radiator panel. These results support the feasibility of using heat pipes in a spacecraft waste heat rejection system.

Swerdling, B.↗

PRODUCTION PROCESS MONITORING OF MULTILAYERED MATERIALS USING TIME-DOMAIN TERAHERTZ GAUGES

The results of both a laboratory and factory trial of a time-domain terahertz (TD-THz) multi-layer gauge for on-line process monitoring are presented. The TD-THz gauge is demonstrated on a two layer laminated plastic insulation material. The TD-THz gauge simultaneously measured the total and the individual layer thicknesses. Measurements were made while transversely scanning across a 12 foot wide sheet extruded at high speed in a factory environment. The results were analyzed for precision, accuracy, and repeatability; and demonstrated that the TD-THz gauge performed in an equivalent or superior manner to existing ionizing radiation gauges (which measure only one layer). Many dielectric materials (e.g., plastic, rubber, paper, paint) are transparent to THz pulses, and the measurement of a wide range of samples is possible.

36 MATERIALS SCIENCE↗

Efficiency of TTAC's ORTEC IDM

ORNL's Technical Testing and Analysis Center (TTAC) acquired a High Purity Germanium Detector (HPGe) from ORTEC - a variant called an Interchangeable Detection Module (IDM). This detector has excellent energy resolution as well as high intrinsic efficiency. The purpose of this report is to detail the determination of the efficiency curve of the IDM, so future measurements can quantify the (otherwise unknown) activity of sources. Without such a curve, the activity cannot be directly reported by use of the IDM alone - a separate device such as an ion chamber would be required. This builds upon the capability of TTAC. The method for determining the energy-dependent intrinsic efficiency is laid-out in this report. It's noteworthy that this basic technique can be applied to any spectroscopic radiation detector, independent of the specific type (e.g. NaI, CzT, ClYC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CFM technologies for space transportation: Multipurpose hydrogen testbed system definition and tank procurement

The development of a test bed tank and system for evaluating cryogenic fluid management technologies in a simulated upper stage liquid hydrogen tank is covered. The tank is 10 ft long and is 10 ft in diameter, and is an ASME certified tank constructed of 5083 aluminum. The tank is insulated with a combination of sprayed on foam insulation, covered by 45 layers of double aluminized mylar separated by dacron net. The mylar is applied by a continuous wrap system adapted from commercial applications, and incorporates variable spacing between the mylar to provide more space between those layers having a high delta temperature, which minimizes heat leak. It also incorporates a unique venting system which uses fewer large holes in the mylar rather than the multitude of small holes used conventionally. This significantly reduces radiation heat transfer. The test bed consists of an existing vacuum chamber at MSFC, the test bed tank and its thermal control system, and a thermal shroud (which may be heated) surrounding the tank. Provisions are made in the tank and chamber for inclusion of a variety of cryogenic fluid management experiments.

Fox, E. C.↗

Effects of Single-Dose Versus Hypofractionated Focused Radiation on Vertebral Body Structure and Biomechanical Integrity: Development of a Rabbit Radiation-Induced Vertebral Compression Fracture Model

Vertebral compression fracture is a common complication of spinal stereotactic body radiation therapy. Development of an in vivo model is crucial to fully understand how focal radiation treatment affects vertebral integrity and biology at various dose fractionation regimens. We present a clinically relevant animal model to analyze the effects of localized, high-dose radiation on vertebral microstructure and mechanical integrity. Using this model, we test the hypothesis that fractionation of radiation dosing can reduce focused radiation therapy's harmful effects on the spine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of V-groove radiator configuration

In the design of spacecraft radiators intended to provide cryogenic cooling, it is important to minimize the space occupied by radiator shielding while satisfying the performance requirements. This study develops and tests the first step toward optimizing radiator shield configurations and examines the design of the highly effective V-groove radiator concept. This investigation, which makes use of a special purpose Monte Carlo/ray tracing computer program, directly identifies the two shield configuration which minimizes radiator footprint for a given temperature drop. Furthermore, multiple shield configurations may be analyzed through a combination of analysis and program statistics. The results presented demonstrate the sensitivity of intershield temperature drop to shield angle and/or offset and provide a comparison of angled and parallel shield configurations. Good agreement with experimental data is shown for a multiple shield configuration.

Schember, Helene R.↗

Basic and applied research related to the technology of space energy conversion systems

The first six months' research effort on the Liquid Droplet Radiator (LDR) focussed on experimental and theoretical studies of radiation by an LDR droplet cloud. Improvements in the diagnostics for the radiation facility have been made which have permitted an accurate experimental test of theoretical predictions of LDR radiation over a wide range of optical depths, using a cloud of Dow silicone oil droplets. In conjunction with these measurements an analysis was made of the evolution of the cylindrical droplet cloud generated by a 2300-hole orifice plate. This analysis indicates that a considerable degree of agglomeration of droplets occurs over the first meter of travel. Theoretical studies have centered on developments of an efficient means of computing the angular scattering distribution from droplets in an LDR droplet cloud, so that a parameter study can be carried out for LDR radiative performance vs fluid optical properties and cloud geometry.

Hertzberg, A.↗