Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Tomographic Imaging of Molecular Orbitals in Length and Velocity Form

Recently Itatani et al. [Nature 432, 876 (2004)] introduced the new concept of molecular orbital tomography, where high harmonic generation (HHG) is used to image electronic wave functions. We describe an alternative reconstruction form, using momentum instead of dipole matrix elements for the electron recombination step in HHG. We show that using this velocity-form reconstruction, one obtains better results than using the original length-form reconstruction. We provide numerical evidence for our claim that one has to resort to extremely short pulses to perform the reconstruction for an orbital with arbitrary symmetry. The numerical evidence is based on the exact solution of the time-dependent Schroedinger equation for 2D model systems to simulate the experiment. Furthermore we show that in the case of cylindrically symmetric orbitals, such as the N{sub 2} orbital that was reconstructed in the original work, one can obtain the full 3D wave function and not only a 2D projection of it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of centricity of optical elements by using a point spread function

Our work describes a technique for testing the centricity of optical systems by using the point spread function. It is shown that a specific position of an axial object point can be found for every optical element, where the spherical aberration is either zero or minimal. If we image such a point with an optical element, then its point spread function will be almost identical to the point spread function of the diffraction-limited optical system. This consequence can be used for testing the centricity of precisely fabricated optical elements, because we can simply detect asymmetry of the point spread function, which is caused by the decentricity of the tested optical element. One can also use this method for testing optical elements in connection with a cementing process. Moreover, a simple formula is also derived for calculation of the coefficient of third-order coma, which is caused by the decentricity of the optical surface due to a tilt of the surface with respect to the optical axis, and a simple method for detecting the asymmetry of the point spread function is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-IeP2-08: Investigation On Signal Detectability in Volumetric Cone Beam CT Images with Anatomical Background

Purpose: To investigate the slice direction dependent detectability in cone beam CT images with anatomical background. Methods: We generated 3D anatomical background images using breast anatomy model. To generate 3D breast anatomy, we filtered 3D Gaussian noise with a square root of 1/f{sup 3}, and then assigned the attenuation coefficient of glandular (0.8cm{sup −1}) and adipose (0.46 cm{sup −1}) tissues based on voxel values. Projections were acquired by forward projection, and quantum noise was added to the projection data. The projection data were reconstructed by FDK algorithm. We compared the detectability of a 3 mm spherical signal in the image reconstructed from four different backprojection Methods: Hanning weighted ramp filter with linear interpolation (RECON1), Hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON3), and ramp filter with Fourier interpolation (RECON4), respectively. We computed task SNR of the spherical signal in transverse and longitudinal planes using channelized Hotelling observer with Laguerre-Gauss channels. Results: Transverse plane has similar task SNR values for different backprojection methods, while longitudinal plane has a maximum task SNR value in RECON1. For all backprojection methods, longitudinal plane has higher task SNR than transverse plane. Conclusion: In this work, we investigated detectability for different slice direction in cone beam CT images with anatomical background. Longitudinal plane has a higher task SNR than transverse plane, and backprojection with hanning weighted ramp filter with linear interpolation method (i.e., RECON1) produced the highest task SNR among four different backprojection methods. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Programs(IITP-2015-R0346-15-1008) supervised by the IITP (Institute for Information & Communications Technology Promotion), Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the MSIP (2015R1C1A1A01052268) and framework of international cooperation program managed by NRF (NRF-2015K2A1A2067635).

60 APPLIED LIFE SCIENCES↗

Magnetic-film atom chip with 10 μm period lattices of microtraps for quantum information science with Rydberg atoms

We describe the fabrication and construction of a setup for creating lattices of magnetic microtraps for ultracold atoms on an atom chip. The lattice is defined by lithographic patterning of a permanent magnetic film. Patterned magnetic-film atom chips enable a large variety of trapping geometries over a wide range of length scales. We demonstrate an atom chip with a lattice constant of 10 μm, suitable for experiments in quantum information science employing the interaction between atoms in highly excited Rydberg energy levels. The active trapping region contains lattice regions with square and hexagonal symmetry, with the two regions joined at an interface. A structure of macroscopic wires, cutout of a silver foil, was mounted under the atom chip in order to load ultracold {sup 87}Rb atoms into the microtraps. We demonstrate loading of atoms into the square and hexagonal lattice sections simultaneously and show resolved imaging of individual lattice sites. Magnetic-film lattices on atom chips provide a versatile platform for experiments with ultracold atoms, in particular for quantum information science and quantum simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept

Purpose: Molecular breast imaging (MBI) is a dedicated nuclear medicine breast imaging modality that employs dual-head cadmium zinc telluride (CZT) gamma cameras to functionally detect breast cancer. MBI has been shown to detect breast cancers otherwise occult on mammography and ultrasound. Currently, a MBI-guided biopsy system does not exist to biopsy such lesions. Our objective was to consider the utility of a novel conical slant-hole (CSH) collimator for rapid (<1 min) and accurate monitoring of lesion position to serve as part of a MBI-guided biopsy system. Methods: An initial CSH collimator design was derived from the dimensions of a parallel-hole collimator optimized for MBI performed with dual-head CZT gamma cameras. The parameters of the CSH collimator included the collimator height, cone slant angle, thickness of septa and cones of the collimator, and the annular areas exposed at the base of the cones. These parameters were varied within the geometric constraints of the MBI system to create several potential CSH collimator designs. The CSH collimator designs were evaluated using Monte Carlo simulations. The model included a breast compressed to a thickness of 6 cm with a 1-cm diameter lesion located 3 cm from the collimator face. The number of particles simulated was chosen to represent the count density of a low-dose, screening MBI study acquired with the parallel-hole collimator for 10 min after a {approx}150 MBq (4 mCi) injection of Tc-99m sestamibi. The same number of particles was used for the CSH collimator simulations. In the resulting simulated images, the count sensitivity, spatial resolution, and accuracy of the lesion depth determined from the lesion profile width were evaluated. Results: The CSH collimator design with default parameters derived from the optimal parallel-hole collimator provided 1-min images with error in the lesion depth estimation of 1.1 {+-} 0.7 mm and over 21 times the lesion count sensitivity relative to 1-min images acquired with the current parallel-hole collimator. Sensitivity was increased via more vertical cone slant angles, larger annular areas, thinner cone walls, shorter cone heights, and thinner radiating septa. Full width at half maximum trended in the opposite direction as sensitivity for all parameters. There was less error in the depth estimates for less vertical slant angles, smaller annular areas, thinner cone walls, cone heights near 1 cm, and generally thinner radiating septa. Conclusions: A Monte Carlo model was used to demonstrate the feasibility of a CSH collimator design for rapid biopsy application in molecular breast imaging. Specifically, lesion depth of a 1-cm diameter lesion positioned in the center of a typical breast can be estimated with error of less than 2 mm using circumferential count profiles of images acquired in 1 min.

60 APPLIED LIFE SCIENCES↗

High-density Schottky barrier IRCCD sensors for remote sensing applications

It is pointed out that the ambitious goals envisaged for the next generation of space-borne sensors challenge the state-of-the-art in solid-state imaging technology. Studies are being conducted with the aim to provide focal plane array technology suitable for use in future Multispectral Linear Array (MLA) earth resource instruments. An important new technology for IR-image sensors involves the use of monolithic Schottky barrier infrared charge-coupled device arrays. This technology is suitable for earth sensing applications in which moderate quantum efficiency and intermediate operating temperatures are required. This IR sensor can be fabricated by using standard integrated circuit (IC) processing techniques, and it is possible to employ commercial IC grade silicon. For this reason, it is feasible to construct Schottky barrier area and line arrays with large numbers of elements and high-density designs. A Pd2Si Schottky barrier sensor for multispectral imaging in the 1 to 3.5 micron band is under development.

Elabd, H.↗

Three-dimensional modeling using x-ray shape-from-silhouette

We present the application of the shape-from-silhouette technique to reconstruct the three-dimensional profile of ancient handworks from their x-ray absorption images. The acquisition technique is similar to tomography, since the images are taken all around the object while it is rotated. Some reference points are placed on a small and light structure corotating with the object, and are acquired on the images for calibration and registration. The reconstruction algorithm gives finally the three-dimensional appearance of the handwork. We present the analysis of a bronze pendant of VI-VII century B.C. (Venetic area, Italy) completely hidden by corrosion products. The three-dimensional reconstruction shows that the pendant is a very elaborated piece, with two embraced figures that were completely invisible at the excavation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction dynamics of recorded holograms in photochromic glass

We have investigated the dynamics of the record-erase process of holograms in photochromic glass using continuum Nd:YVO{sub 4} laser radiation ({lambda}=532 nm). A bidimensional microgrid pattern was formed and visualized in photochromic glass, and its diffraction efficiency decay versus time (during reconstruction step) gave us information (D, {Delta}n) about the diffusion process inside the material. The recording and reconstruction processes were carried out in an off-axis setup, and the images of the reconstructed object were recorded by a CCD camera. Measurements realized on reconstructed object images using holograms recorded at a different incident power laser have shown a two-stage process involved in silver atom kinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Piezoresponse and magnetic properties of multiferroic (1−x)Bi{sub 0.9}Dy{sub 0.1}FeO{sub 3}–xPbTiO{sub 3} solid solution

The multiferroic solid solution of (1−x)[0.9BiFeO{sub 3}–0.1DyFeO{sub 3}]–xPbTiO{sub 3} with compositions around the morphotropic phase boundary has been synthesized in the form of ceramics and characterized by Piezoresponse Force Microscope (PFM) and Superconducting Quantum Interference Device. Both the original local polar domain structure and the domain evolution after poling have been studied by PFM. The PFM phase imaging has revealed some interesting details of poling and domain switching process: The out-of-plane phase image shows a uniform direction of polarization along the applied electric field, while the in-plane phase image indicates two kinds of domains with antiparallel polarizations. This kind of poled domain structure is explained based on the orientations of the polarization as permitted by the rhombohedral crystal symmetry in grains of different crystallographic orientations. The magnetic properties measured within the temperature range from 1.8 K to 300 K reveal an interesting sequence of magnetic transitions from a weakly ferromagnetic order (WFM{sub 1}) to an antiferromagnetic state (AFM), and then to another weak ferromagnetic phase (WFM{sub 2}), upon cooling. A preliminary magnetic phase diagram is proposed for BDF-34PT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of compressed breast thickness by optical stereoscopic photogrammetry

The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of the breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Macro-carriers of plastic deformation of steel surface layers detected by digital image correlation

This paper presents a study of characteristics of an evolution of deformation fields in surface layers of medium-carbon low-alloy specimens under compression. The experiments were performed on the “Universal Testing Machine 4500” using a digital stereoscopic image processing system Vic-3D. A transition between stages is reflected as deformation redistribution on the near-surface layers. Electronic microscopy shows that the structure of the steel is a mixture of pearlite and ferrite grains. A proportion of pearlite is 40% and ferrite is 60%.

36 MATERIALS SCIENCE↗

Determining the Spatial Profiles of Electron and Hole Concentration, Radiative and Non-Radiative Recombination Rate Near a Dislocation Defect by Combining Raman and Photoluminescence Imaging

For commonly utilized photoluminescence (PL) imaging, the spatial resolution is dictated by the carrier diffusion length rather than by that dictated by the optical system, such as diffraction limit. Here, we show that Raman imaging of the LO phonon-plasmon (LOPP) coupled mode can be used to recover the intrinsic spatial resolution of the optical system, as demonstrated by Raman imaging of defects in GaAs, achieving a 10-fold improvement in resolution. Furthermore, by combining Raman and PL imaging, we can independently determine the spatial profiles of the electron and hole density, radiative and non-radiative recombination rate near a dislocation defect, which has not been possible using other techniques.

14 SOLAR ENERGY↗

Optical properties of graphene-based materials in transparent polymer matrices

Different aspects of graphene-based materials (GBMs) and GBM-nanocomposites have been investigated due to their intriguing features; one of these features is their transparency. Transparency of GBMs has been of an interest to scientists and engineers mainly with regard to electronic devices. In this study, optical transmittance of structural, purpose-made nanocomposites reinforced with GBMs was analyzed to lay a foundation for optical microstructural characterization of nanocomposites in future studies. Two main types of GBM reinforcements were studied, graphene oxide (GO) and graphite nanoplates (GNPs). The nanocomposites investigated are GO/poly(vinyl alcohol), GO/sodium alginate, and GNP/epoxy with different volume fractions of GBMs. Together with UV-visible spectrophotometry, image-processing-assisted micro and macro photography were used to assess the transparency of GBMs embedded in the matrices. The micro and macro photography methods developed were proven to be an alternative way of measuring light transmittance of semi-transparent materials. It was found that there existed a linear relationship between light absorbance and a volume fraction of GBMs embedded in the same type of polymer matrices, provided that the nanocomposites of interest had the same thicknesses. This suggests that the GBM dispersion characteristics in the same type of polymer are similar and any possible change in crystal structure of polymer due to different volumetric contents of GBM does not have an effect on light transmittance of the matrices. The study also showed that the same types of GBMs could display different optical properties in different matrix materials. The results of this study will help to develop practical microstructural characterization techniques for GBM-based nanocomposites.

36 MATERIALS SCIENCE↗

Femtosecond laser ablation induced plasma characteristics from submicron craters in thin metal film

The ablation-induced plasma physics at reduced ablation crater dimensions is experimentally investigated. Frequency doubled femtosecond laser pulses are tightly focused through objective lenses onto a Cr thin film coated on quartz wafer in order to obtain ablation craters of submicron lateral dimensions. Side-view time-resolved emission images and the corresponding spectra depict the detailed plasma evolution at the fluence range near the ablation threshold. Collected emission spectra at the laser fluence level of around two to three times of ablation threshold display characteristic atomic transition peaks of the ablated Cr material from submicron ablation craters. This finding confirms that improved spatial resolution for laser-induced breakdown spectroscopy can be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent progress of hard x-ray imaging microscopy and microtomography at BL37XU of SPring-8

A hard x-ray imaging microscopy and microtomography system is now being developed at the beamline 37XU of SPring-8. In the latest improvement, a spatial resolution of about 50 nm is achieved in two-dimensional imaging at 6 keV x-ray energy using a Fresnel zone plate objective with an outermost zone width of 35 nm. In the tomographic measurement, a spatial resolution of about 100 nm is achieved at 8 keV using an x-ray guide tube condenser optic and a Fresnel zone plate objective with an outermost zone width of 50 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overcoming diffusion-related limitations in semiconductor defect imaging with phonon-plasmon-coupled mode Raman scattering

Carrier diffusion is of paramount importance in many semiconductor devices, such as solar cells, photodetectors, and power electronics. Structural defects prevent such devices from reaching their full performance potential. Although a large carrier diffusion length indicates high material quality, it also implies increased carrier depletion by an individual extended defect (for instance, a dislocation) and obscures the spatial resolution of neighboring defects using optical techniques. For commonly utilized photoluminescence (PL) imaging, the spatial resolution is dictated by the diffusion length rather than by the laser spot size, no matter the spot is at or below the diffraction limit. We show how Raman imaging of the LO phonon-plasmon-coupled mode can be used to recover the intrinsic spatial resolution of the optical system, and we demonstrate the effectiveness of the technique by imaging defects in GaAs with diffraction-limited optics, achieving a 10-fold improvement in resolution. Furthermore, by combining Raman and PL imaging, we can independently and simultaneously determine the spatial dependence of the electron density, hole density, radiative recombination rate, and non-radiative recombination rate near a dislocation-like defect, which has not been possible using other techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Current Status of the Development of Light-Sensitive Media for Holography (a Review)

The results of studies that have been performed over the last decade in the field of development of silver halide and nonsilver holographic recording media of organic and inorganic origin are analyzed. It is shown that previously developed materials mainly allow the development of holographic investigations. Among irreversible materials, considerable progress has been made in improving the characteristics of photopolymerizable recording media, which has allowed their use in color image holography and 3D optical archive-type memory, as well as for fabricating holographic optical elements. In the field of improving the properties of reversible holographic recording media, practically significant results have been obtained for the creation of photoanisotropic materials based on azo dyes experiencing cis–trans photoisomerization, which allow the recording of polarization holograms. The needs of dynamic holography have been satisfied by lightsensitive doped inorganic crystals and polymer layers that have been created with nonlinear optical properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimising the effect of nanoparticle deformation in intermittent contact amplitude modulation atomic force microscopy measurements

The results of systematic height measurements of polystyrene (PS) nanoparticles using intermittent contact amplitude modulation atomic force microscopy (IC-AM-AFM) are presented. The experimental findings demonstrate that PS nanoparticles deform during AFM imaging, as indicated by a reduction in the measured particle height. This deformation depends on the IC-AM-AFM imaging parameters, material composition, and dimensional properties of the nanoparticles. A model for nanoparticle deformation occurring during IC-AM-AFM imaging is developed as a function of the peak force which can be calculated for a particular set of experimental conditions. The undeformed nanoparticle height can be estimated from the model by extrapolation to zero peak force. A procedure is proposed to quantify and minimise nanoparticle deformation during IC-AM-AFM imaging, based on appropriate adjustments of the experimental control parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗