Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Excited state dynamics of CH 2 I 2 and CH 2 BrI studied with UV pump VUV probe photoelectron spectroscopy

We compare the excited state dynamics of diiodomethane (CH 2 I 2 ) and bromoiodomethane (CH 2 BrI) using time resolved photoelectron spectroscopy. A 4.65 eV UV pump pulse launches a dissociative wave packet on excited states of both molecules and the ensuing dynamics are probed via photoionization using a 7.75 eV probe pulse. The resulting photoelectrons are measured with the velocity map imaging technique for each pump-probe delay. Our measurements highlight differences in the dynamics for the two molecules, which are interpreted with high-level ab initio molecular dynamics (trajectory surface hopping) calculations. Our analysis allows us to associate features in the photoelectron spectrum with different portions of the excited state wave packet represented by different trajectories. The excited state dynamics in bromoiodomethane are simple and can be described in terms of direct dissociation along the C–I coordinate, whereas the dynamics in diiodomethane involve internal conversion and motion along multiple dimensions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer

We have constructed a low-cost, portable, high-sensitivity 16-channel optically pumped magnetometer (OPM), operating in the spin-exchange relaxation-free regime, and demonstrated its applications in magnetocardiography (MCG). The decrease in the cost of sensors by an order of magnitude is achieved by the 16-channel operation realized in a single module using a single large flat pancake rubidium vapor cell, broad pump and probe laser beams, and a 16-channel photodiode array. The OPM is also based on a fiber-coupled nearly parallel-beam configuration to facilitate multichannel design and make the system portable. For human MCG experiments, the 16-channel OPM which includes optical components is placed inside a wooden enclosure for laser safety. The enclosure is set on a nonmagnetic table inside a magnetically shielded room, while the lasers and electronics are placed outside the shielding room, to avoid magnetic noise. We show that the 16-channel OPM enables simultaneous imaging of human cardiac activity on a large area of the chest in a single scan. The multichannel capability will accelerate clinical MCG imaging to reduce the procedure time and patient fatigue.

59 BASIC BIOLOGICAL SCIENCES↗

A combined multi-reference pump-probe simulation method with application to XUV signatures of ultrafast methyl iodide photodissociation

Here, UV pump-XUV/X-ray probe measurements have been successfully applied in the study of photo-induced chemical reactions. Although rich element-specific electronic structure information is accessible within XUV/X-ray (inner-shell) absorption spectra, it can be difficult to interpret the chemistry directly from the spectrum without supporting theoretical simulations. A multireference method to completely simulate UV pump-XUV/X-ray probe measurement has been developed and applied to study the methyl iodide photodissociation process. Multireference, fewest-switches surface hopping (FSSH) trajectories were used to explore the coupled electronic and ionic dynamics upon photoexcitation of methyl iodide. Interpretation of previous measurements is provided by associated multireference, restricted active space, inner-shell spectral simulations. This combination of multireference FSSH trajectories and XUV spectra provides an interpretation of transient features appearing in previous measurements within the first 100 fs after photoexcitation and validates the significant branching ratio in the final excited-state population. Finally, this methodology should prove useful for interpretation of the increasing number of inner-shell probe studies of molecular excited states or for directing new experiments toward interesting regions of the potential energy landscape.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited state dynamics of cis , cis -1,3-cyclooctadiene: UV pump VUV probe time-resolved photoelectron spectroscopy

We present UV pump, vacuum ultraviolet probe time-resolved photoelectron spectroscopy measurements of the excited state dynamics of cis,cis-1,3-cyclooctadiene. A 4.75 eV deep UV pump pulse launches a vibrational wave packet on the first electronically excited state, and the ensuing dynamics are probed via ionization using a 7.92 eV probe pulse. The experimental results indicate that the wave packet undergoes rapid internal conversion to the ground state in under 100 fs. Comparing the measurements with electronic structure and trajectory surface hopping calculations, we are able to interpret the features in the measured photoelectron spectra in terms of ionization to several states of the molecular cation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Rotational pumping revisited

This paper considers a pure electron plasma, with a small admixture of negative ions, confined in a Penning–Malmberg trap. When a diocotron mode is excited on the plasma, the end sheaths of the plasma are azimuthally distorted. During reflection at a distorted end sheath, an ion steps off of the surface characterizing the drift motion in the plasma interior, and this step produces transport. The diocotron mode transfers canonical angular momentum to the ions, and in response damps. These transport mechanism and associated damping are called rotational pumping. It is particularly strong when the axial bounce motion and the rotational drift motion, in the rotating frame of the mode, satisfy a resonance condition. This paper calculates the transport flux of ions and the associated damping rate of the mode in the resonant regime. Previous papers have discussed the theory and the experimental observation of rotational pumping for the special case of a diocotron mode with azimuthal wave number l = 1, and this paper extends the theory to modes with l≠1, which may sound like a trivial extension, but in fact is not.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of yellow (568 nm) stimulated emission from optically pumped InGaN/GaN multi-quantum wells

We demonstrate room-temperature stimulated emission at 568 nm from low dislocation density InGaN/GaN multi-quantum wells. For a 1.4 mm long and a 50 $μ$4m wide ridge bar optically pumped by a high-power pulsed laser, we observed an emission peak at 568 nm with a narrow spectral width of less than 2 nm at room temperature. The measured pumping threshold is less than 1.5 MW/cm 2 , and the polarization ratio of the emission is over 90%. In conclusion, this demonstration paves the way for the future development of electrically injected InGaN semiconductor yellow laser diodes.

36 MATERIALS SCIENCE↗

Implementation of a laser–neutron pump–probe capability for inelastic neutron scattering

Knowledge about nonequilibrium dynamics in spin systems is of great importance to both fundamental science and technological applications. Inelastic neutron scattering (INS) is an indispensable tool to study spin excitations in complex magnetic materials. However, conventional INS spectrometers currently only perform steady-state measurements and probe averaged properties over many collision events between spin excitations in thermodynamic equilibrium, while the exact picture of re-equilibration of these excitations remains unknown. In this paper, we report on the design and implementation of a time-resolved laser–neutron pump–probe capability at hybrid spectrometer (beamline 14-B) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. This capability allows us to excite out-of-equilibrium magnons with a nanosecond pulsed laser source and probe the resulting dynamics using INS. Here, we discussed technical aspects to implement such a capability in a neutron beamline, including choices of suitable neutron instrumentation and material systems, laser excitation scheme, experimental configurations, and relevant firmware and software development to allow for time-synchronized pump–probe measurements. We demonstrated that the laser-induced nonequilibrium structure factor is able to be resolved by INS in a quantum magnet. In conclusion, the method developed in this work will provide SNS with advanced capabilities for performing out-of-equilibrium measurements, opening up an entirely new research direction to study out-of-equilibrium phenomena using neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable quasi-cw two-micron lasing in diode-pumped crystals of mixed Tm{sup 3+}-doped sodium - lanthanum - gadolinium molybdates and tungstates

Two-micron lasing is obtained for the first time on the {sup 3}F{sub 4} {yields} {sup 3}H{sub 6} transition of Tm{sup 3+} ions in diode-pumped crystals of mixed sodium - lanthanum - gadolinium tungstate Tm:NaLa{sub 1/2}Gd{sub 1/2}(WO{sub 4}){sub 2} (C{sub Tm} = 3.6 at %) (3.6Tm : NLGW) and molybdate Tm:NaLa{sub 1/3}Gd{sub 2/3}(MoO{sub 4}){sub 2} (C{sub Tm} = 4.8 at %) (4.8Tm : NLGM). For the 3.6Tm : NLGW crystal, the quasi-cw laser output power exceeded 200 mW and the slope efficiency (with respect to absorbed pump power) for the {pi}- and {sigma}-polarisations at wavelengths of 1908 and 1918 nm was 34% and 30%, respectively. The laser wavelength of this crystal was continuously tuned within the spectral range of 1860 - 1935 nm. For the 4.8Tm : NLGM crystal, the slope efficiency for the {pi}- and {sigma}-polarisations at wavelengths of 1910 and 1918 nm was 27% and 23%, respectively, and the laser wavelength was tunable within the spectral range of 1870 - 1950 nm. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lasing of polycrystalline Cr{sup 2+}:ZnSe pumped by a pulse-periodic Tm:YLF laser

The output characteristics of a laser based on polycrystalline Cr{sup 2+}:ZnSe obtained by diffusion annealing are studied upon pumping by a cw-diode-pumped Q-switched Tm:YLF laser operating at a wavelength of 1.908 {mu}m with a pulse repetition rate of 2 kHz. Efficient pulse-periodic lasing is obtained in the region of 2.32 {mu}m with a total efficiency of {approx}17%, a pulse duration of {approx}45 ns, and an average power of {approx}1 W. (lasers and amplifiers)

36 MATERIALS SCIENCE↗

Planar repetitively pulsed microwave-pumped CO{sub 2} laser

A planar repetitively pulsed microwave-pumped CO{sub 2} laser with discharge channel lengths of 250 and 470 mm is experimentally investigated. An average laser power of 60 W at a wavelength of 10.6 {mu}m is attained. A peak power of 1300 W is reached in the repetitively pulsed regime. The dependences of the shape and energy of CO{sub 2} laser pulse on the introduced power, working gas mixture composition and pressure, and pump-pulse repetition rate and width are analysed. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Longitudinal discharge pumped low-pressure XeCl laser

We have studied output parameters of a XeCl and a N{sub 2} laser pumped by a longitudinal discharge with automatic spark UV preionisation. The output parameters of a low-pressure (30 Torr) XeCl laser operating with Ar, Ne and He as buffer gases or with no buffer gas have been optimised for the first time. The laser generated 5-ns FWHM pulses with an average power of 0.5 mW and output energy of 0.15 mJ. Under longitudinal discharge pumping, an output energy per unit volume of 1.8 J L{sup -1} atm{sup -1} was reached using helium as a buffer gas. With argon-containing and buffer-free mixtures, it was 1.5 J L{sup -1} atm{sup -1}. The N{sub 2} laser generated 2.5-ns FWHM pulses with an average power of 0.35 mW and output energy of 0.05 mJ. (lasers)

74 ATOMIC AND MOLECULAR PHYSICS↗

Lasing characteristics of ZrO{sub 2} − Y{sub 2}O{sub 3} − Ho{sub 2}O{sub 3} crystals pumped by a Tm : LiYF{sub 4} laser

Two-micron lasing is obtained on the {sup 5}I{sub 7} → {sup 5}I{sub 8} transition of Ho{sup 3+} ions in ZrO{sub 2} − Y{sub 2}O{sub 3} −Ho{sub 2}O{sub 3} crystals upon resonance pumping into the {sup 5}I{sub 7} level of these ions by a pulsed laser based on a Tm : LiYF{sub 4} crystal. The efficiency of conversion of pump radiation incident on the crystal to laser radiation and the slope lasing efficiency at a pulse duration of 8 ms and a pulse repetition rate of 10 Hz were 25% and 28%, respectively. (paper)

36 MATERIALS SCIENCE↗

Spin-exchange relaxation-free magnetometer with nearly parallel pump and probe beams

We constructed a spin-exchange relaxation-free (SERF) magnetometer with a small angle between the pump and probe beams facilitating a multi-channel design with a flat pancake cell. This configuration provides almost complete overlap of the beams in the cell, and prevents the pump beam from entering the probe detection channel. By coupling the lasers in multi-mode fibers, without an optical isolator or field modulation, we demonstrate a sensitivity of 10 fT$/\sqrt{\text{Hz}}$ for frequencies between 10 Hz and 100 Hz. In addition to the experimental study of sensitivity, we present a theoretical analysis of SERF magnetometer response to magnetic fields for small-angle and parallel-beam configurations, and show that at optimal DC offset fields the magnetometer response is comparable to that in the orthogonal-beam configuration. Based on the analysis, we also derive fundamental and probe-limited sensitivities for the arbitrary non-orthogonal geometry. The expected practical and fundamental sensitivities are of the same order as those in the orthogonal geometry. As a result, we anticipate that our design will be useful for magnetoencephalography (MEG) and magnetocardiography (MCG) applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cross-beam energy transfer saturation: ion heating and pump depletion

Cross-beam energy transfer (CBET) was measured in two regimes where the energy transfer saturation mechanism was determined by the plasma and laser beam conditions. Here, linear kinetic CBET theory agrees well with the measured energy transfer in all experimental configurations and at all probe beam intensities when accounting for pump depletion and the plasma conditions measured using Thomson-scattering. Simultaneous CBET and Thomson-scattering measurements enabled uncertainties in the plasma conditions to be isolated from CBET theory, which allowed the saturation mechanisms to be identified. In the perpendicular-beam configuration the saturation mode was through ion heating, which resulted from ion trapping in the driven waves and subsequent ion-ion collisional heating. In the co-propagating beam configuration there was minimal ion heating and the saturation mode was through pump depletion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TURBULENT PUMPING OF MAGNETIC FLUX REDUCES SOLAR CYCLE MEMORY AND THUS IMPACTS PREDICTABILITY OF THE SUN'S ACTIVITY

Prediction of the Sun's magnetic activity is important because of its effect on space environment and climate. However, recent efforts to predict the amplitude of the solar cycle have resulted in diverging forecasts with no consensus. Yeates et al. have shown that the dynamical memory of the solar dynamo mechanism governs predictability, and this memory is different for advection- and diffusion-dominated solar convection zones. By utilizing stochastically forced, kinematic dynamo simulations, we demonstrate that the inclusion of downward turbulent pumping of magnetic flux reduces the memory of both advection- and diffusion-dominated solar dynamos to only one cycle; stronger pumping degrades this memory further. Thus, our results reconcile the diverging dynamo-model-based forecasts for the amplitude of solar cycle 24. We conclude that reliable predictions for the maximum of solar activity can be made only at the preceding minimum-allowing about five years of advance planning for space weather. For more accurate predictions, sequential data assimilation would be necessary in forecasting models to account for the Sun's short memory.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin pumping driven by magnon-polaritons in a ferromagnet–coplanar superconducting resonator hybrid system

We demonstrate spin pumping driven by a strongly coupled magnon-photon system using a ferromagnet-coplanar superconducting resonator hybrid system at 1.4 K. Electrical readout via the inverse spin-Hall effect reveals characteristic coupling features, including mode splitting and linewidth broadening, demonstrating the electrical detection of strongly coupled microwave photons and magnons. The microwave magnon-photon coupling strength obtained by combined spin pumping and inverse spin-Hall effect measurements is compared to microwave transmission experiments. Here, microwave power-dependent measurements reveal a decrease in the coupling strength with increasing microwave power alongside the onset of nonlinearities of the superconducting resonator above a critical microwave power threshold.

Wagle, Dinesh [University of Delaware, Newark, DE ↗