Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “programming systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Integrated membrane material design and system synthesis

In designing membrane systems, the synergy between membrane materials and the process design is often overlooked. In this paper, we present a mixed-integer nonlinear programming (MINLP) model for synthesizing membrane systems while simultaneously designing the respective membrane materials for multicomponent gas separation. The approach considers superstructure representations for systems with: (1) same, (2) potentially different, and (3) property-targeting membrane materials. In the first two systems, the selection of membrane material is a decision, while in the final type, membrane permeances are subject to optimization. Physics-based surrogate models are used to describe permeation in crossflow and countercurrent flow permeators. We show that, through a case study of biogas upgrading, our approach obtains high quality solutions. Furthermore, we use the proposed approach while considering permeance-based production cost to find the optimal membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-502: Initial Results of a Comparison of Treatment Plans Produced From Automated Prioritized Planning Method and a Commercial Treatment Planning System

Purpose We developed an automated treatment planning system based on a hierarchical goal programming approach. To demonstrate the feasibility of our method, we report the comparison of prostate treatment plans produced from the automated treatment planning system with those produced by a commercial treatment planning system. Methods In our approach, we prioritized the goals of the optimization, and solved one goal at a time. The purpose of prioritization is to ensure that higher priority dose-volume planning goals are not sacrificed to improve lower priority goals. The algorithm has four steps. The first step optimizes dose to the target structures, while sparing key sensitive organs from radiation. In the second step, the algorithm finds the best beamlet weight to reduce toxicity risks to normal tissue while holding the objective function achieved in the first step as a constraint, with a small amount of allowed slip. Likewise, the third and fourth steps introduce lower priority normal tissue goals and beam smoothing. We compared with prostate treatment plans from Memorial Sloan Kettering Cancer Center developed using Eclipse, with a prescription dose of 72 Gy. A combination of liear, quadratic, and gEUD objective functions were used with a modified open source solver code (IPOPT). Results Initial plan results on 3 different cases show that the automated planning system is capable of competing or improving on expert-driven eclipse plans. Compared to the Eclipse planning system, the automated system produced up to 26% less mean dose to rectum and 24% less mean dose to bladder while having the same D95 (after matching) to the target. Conclusion We have demonstrated that Pareto optimal treatment plans can be generated automatically without a trial-and-error process. The solver finds an optimal plan for the given patient, as opposed to database-driven approaches that set parameters based on geometry and population modeling.

60 APPLIED LIFE SCIENCES↗

SBIR Phase II Final Report - Multi-Protocol Energy Management Gateway for Home-Area Networks

Significant amounts of electricity, natural gas, and heating oil are wasted by homeowners due to inefficient operation and inadequate maintenance of heating, ventilation, and air conditioning (HVAC) equipment. Coincident’s work under this award reduces energy waste, saves consumers money, and reduces carbon emissions. It does so in three ways: First, Coincident’s approach replaces the traditional thermostat with a wireless network of sensors and controllers that measure temperature, humidity and occupancy in multiple rooms in the house. The “Internet of Things” is a technology trend holding the promise of ubiquitous inexpensive sensors. The reality, however, is that energy and HVAC monitoring and management is a patchwork of incompatible protocols and expensive proprietary technologies. Coincident’s multi-protocol architecture, developed in part under this award tackles this problem and brings low cost interoperable sensor and control devices to market. Second, the Coincident system eliminates hard-to-program and rigid thermostat schedules and instead provides automatic operation of heating and cooling by combining individual temperature and comfort preferences with energy-saving targets, real-time utility use information, weather data, and room utilization patterns. Energy efficiency technology must be appealing to consumers otherwise it will not be used. The Coincident user interface has engaging features such as remote control from any smart phone or web browser and per-room performance breakdowns. Expected energy savings resulting from more efficient operation of heating and air conditioning equipment are in the range of 10-20%. Third, the Coincident system provides heating and air-conditioning contractors with fine-grained performance data for every residence they support (subject to customer privacy controls). This data is integrated from diverse networks within the residence and includes HVAC performance and fuel use data. This information allows the partner to validate energy savings and identify potential system faults (whether from installation problems or maintenance issues). When combined with professional installation as part of high-efficiency HVAC upgrade, energy savings levels of 20-30% can be achieved. Economic feasibility of energy efficiency technology is one of the key challenges addressed in this award. The Coincident system is engineered to be delivered at a disruptive price point, making the system financially feasible for new and retrofit homes of all types and sizes. The Coincident system is intended to be sold through the HVAC professional—the industry most capable of improving HVAC efficiency. Providing HVAC contractors with detailed home performance data motivates them to sell the product, provides them with maintenance and upgrade revenue opportunities, and therefore delivers customer savings and environmental benefits. Having demonstrated technical and financial feasibility, Coincident has won additional grants and awards, participated in pilot projects, started partnership discussions with several HVAC equipment vendors, and has lined up several large channel partners ready to participate in large pilot rollouts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bioimaging Science Program Principal Investigator Meetings Proceedings (2021)

As part of the 2021 Biological Systems Science Division (BSSD) Principal Investigator (PI) Meeting, the Bioimaging Science program (BSP), within BSSD's Biomolecular Characterization and Imaging Science portfolio, held its annual PI meeting virtually February 22–23. BSP's mission is to understand the translation of genomic information into the mechanisms that power living cells, communities of cells, and whole organisms. The goal of BSP is to develop new imaging and measurement technologies to visualize the spatial and temporal relationships of key metabolic processes governing phenotypic expression in plants and microbes. BSP convenes annual PI meetings to bring together its contributing investigators to review progress and current state-of-the-art bioimaging research. Holding the BSP meeting as part of the broader BSSD PI meeting allowed researchers to interact with the extended Genomic Science program community. This convergence provided a platform for networking and exchange of ideas, helping to forge new multidisciplinary collaborations among investigators from the two sister programs. An important highlight of the BSP meeting was the keynote presentation “Enhancing Fluorescence Microscopy with Computation” by Dr. Hari Shroff of the NIH National Institute of Biomedical Imaging and Bioengineering. All the BSP PIs made presentations describing their research focus and progress, and these were followed by roundtable discussions of each project. The meeting’s proceedings provide an outline of the program’s current state and potential future directions and opportunities.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling and Simulation - Introducing hardware-in-the-loop capabilities to the Human Systems Simulation Laboratory

The DOE Office of Nuclear Energy (DOE-NE) cybersecurity program would like to expand the use of the Human Systems Simulation Laboratory to include capabilities for cybersecurity research and development. Specifically, the introduction of hardware-in-the-loop (HITL) simulation of nuclear power plant architecture into the HSSL will enable researchers and nuclear utilities the ability to identify impacts generated by sophisticated hostile cyber adversaries to identify the consequences of simulated potential attack vectors, and to develop solutions for detecting or preventing these cyber attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modern modulation schemes: a linear programming based tone injection algorithm for PAPR reduction of OFDM and linearly precoded systems

This work investigates the improvement of power amplifier efficiency through the reduction of peak-to-average power ratio (PAPR) of linearly precoded QAM data signals. In particular, we fo cus on the special cases of linear precoded modulation including the practical OFDM, OFDMA, and SC-FDMA signals that have been widely adopted in W-LAN and W-MAN. We apply the method of tone injection optimization for PAPR reduction. To reduce numerical complexity, we propose a linear programming algorithm which closely approximates the original tone injection optimization problem. Our comprehensive numerical results demonstrate substantial PAPR reduc tion and superior BER performance using several practical examples.

Jacklin, Neil↗

A Case Study in Market Transformation for Residential Energy Efficiency Programs

This case study describes how the Midwest Energy Efficiency Alliance (MEEA) partnered with gas and electric utilities in Iowa to establish the Iowa residential heating, ventilation, and air conditioning System Adjustment and Verified Efficiency (HVAC SAVE) program, taking it to scale improving the performance and energy efficiency of HVAC systems, growing businesses, and gaining consumer trust.

Federal efficiency standards, installation practic↗

YALINA facility a sub-critical Accelerator- Driven System (ADS) for nuclear energy research facility description and an overview of the research program (1997-2008).

The YALINA facility is a zero-power, sub-critical assembly driven by a conventional neutron generator. It was conceived, constructed, and put into operation at the Radiation Physics and Chemistry Problems Institute of the National Academy of Sciences of Belarus located in Minsk-Sosny, Belarus. This facility was conceived for the purpose of investigating the static and dynamic neutronics properties of accelerator driven sub-critical systems, and to serve as a neutron source for investigating the properties of nuclear reactions, in particular transmutation reactions involving minor-actinide nuclei. This report provides a detailed description of this facility and documents the progress of research carried out there during a period of approximately a decade since the facility was conceived and built until the end of 2008. During its history of development and operation to date (1997-2008), the YALINA facility has hosted several foreign groups that worked with the resident staff as collaborators. The participation of Argonne National Laboratory in the YALINA research programs commenced in 2005. For obvious reasons, special emphasis is placed in this report on the work at YALINA facility that has involved Argonne's participation. Attention is given here to the experimental program at YALINA facility as well as to analytical investigations aimed at validating codes and computational procedures and at providing a better understanding of the physics and operational behavior of the YALINA facility in particular, and ADS systems in general, during the period 1997-2008.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Start-up Optimization Considering Integrated Power Electronic Systems

The startup of systems composed of power electronic systems is becoming more complex. As the systems grow, standard pre-configuration sequencing methods will struggle. This work proposes a linear programming optimization method to couple power electronic systems in a series of startup commands. This formulation is demonstrated in a real-time implementation on hardware.

Starke, Michael↗

DERMS-RT (Distributed Energy Resource Management Solution using Real-Time Optimization) [SWR-20-46]

DERMS-RT provides a distributed energy resource management solution using real-time optimization to control different types of distributed energy resources (DERs) — such as rooftop PVs, battery energy storage systems, HVAC loads, electric water heater loads, and EV charging loads, and use these DERs to provide distribution voltage regulation and peak demand management services. The control approach implemented by DERM-RT is developed based on the real-time optimal power flow and distributed control previously developed by NREL researchers. The software codes are designed to provide modular DER management solution that can be easily applied to control heterogeneous DERs in distribution grids in coordination with centralized utility management systems. Also, DERMS-RT provides application programming interface (API) to extract useful grid model information from an open-source power system simulation software, use the information to solve the optimization problem, and apply the optimal set-points to the controlled DERs. In this way, DERMS-RT provides a plug-and-play function for implementing the real-time DER control on different utility system models, and it can be used as a simulation testbed to demonstrate the impact of real-time DER optimization on improving grid operations.

Ding, Fei↗

Roadmap for photovoltaic cyber security

Cyber-secure, resilient energy is paramount to the prosperity of the United States. As the experience and sophistication of cyber adversaries grow, so too must the US power system’s defenses, situational awareness, and response and recovery strategies. Traditionally, power systems were operated with dedicated communication channels to large generators and utility-owned assets but now there is greater reliance on photovoltaic (PV) systems to provide power generation. PV systems often communicate to utilities, aggregators, and other grid operators over the public internet so the power system attack surface has significantly expanded. At the same time, solar energy systems are equipped with a range of grid-support functions, that—if controlled or programmed improperly—present a risk of power system disturbances. This document is a five-year roadmap intended to chart a path for improving cyber security for communication-enabled PV systems with clear roles and responsibilities for government, standards development organizations, PV vendors, and grid operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Area Control Error Diversity Interchange (ADI) Program by Incorporating Congestion Constraints

The area control error (ACE) determines how much a balancing authority (BA) needs to move its regulating units to meet mandatory control performance standard requirements. Regulation is an expensive resource that could cost several hundred million dollars a year for a BA. The amount of regulation needed in a system is increasing with more intermittent generation resources added to the system. The ACE diversity interchange (ADI) program provides a tool for reducing the regulation requirement by combining ACEs from several participating BAs followed by sharing the total ACE among all participating balancing areas. The effect is achieved as a result of the low statistical correlation between the original ACEs of participating BAs. A rule-based ADI approach has already been put into practice in the US Western Interconnection. The degree of actual ACE sharing is artificially limited because of the unknown redistribution of power flows and possible system congestion (these factors are not monitored in the existing ADI). This paper proposes a two-step linear programming (LP) ADI approach that incorporates congestion constraints. In the first step of the proposed LP ADI, the line transmission limits are enforced by setting up corresponding constraints. In the second step, the business fairness is pursued. Simulation is performed to compare the properties of the proposed LP ADI and the existing rule-based ADI. Favorable features, such as avoiding line limit violations and increasing the degree of possible ACE sharing, are observed for the proposed LP ADI.

99 GENERAL AND MISCELLANEOUS↗

Survival of Juvenile Chinook Salmon during Barge Transport

To mitigate for fish losses related to passage through the Federal Columbia River Power System, an extensive fish transportation program using barges and trucks to move fish around and downstream of dams and reservoirs was implemented in 1981. Population modeling and other analyses to support Pacific salmon recovery efforts have assumed that the survival of juvenile salmonids during the transportation experience was 98%. To estimate survival during barge transport from Lower Granite Dam on the Snake River to a release area downstream of Bonneville Dam, a distance of 470 km, we used a novel adaptation of a release-recapture model with acoustic-tagged yearling Chinook salmon (Oncorhynchus tshawytscha) smolts. A total of 1,494 yearling Chinook salmon were surgically implanted with Juvenile Salmon Acoustic Telemetry System (JSATS) acoustic transmitters and passive integrated transponders (PIT) and divided into three groups. The three tagged groups consisted of; (1) a group which was released into the raceway with the population of fish which were later loaded into transportation barges (R{sub B}), (2) a group which was held in a net-pen suspended within the general barge population until 5-6 h prior to barge evacuation, at which time they were confirmed to be alive and then released into the general barge population (R{sub A}), and (3) to validate a model assumption, a group which was euthanized and released into the barge population 2-8 h prior to barge evacuation (R{sub D}). Six replicates of these groups were loaded onto fish transport barges that departed Lower Granite Dam on the Snake River between 29 April and 13 May, 2010. Acoustic receiver arrays between 70 and 220 km downstream of the barge evacuation site were used to detect tagged fish and served as the basis for estimation of survival within the barge. Tag-life-corrected estimates of reach survival were calculated for barged and control fish in each of the six replicate trials. The ratio of survival from release to Rkm 153 for barged fish relative to control fish provided the estimate of within-barge survival. The replicate survival estimates ranged from 0.9503 (SE = 0.0253) to 1.0003 (SE = 0.0155). The weighted average of the replicate estimates of within-barge survival was computed to be = 0.9833 (SE = 0.0062). This study provides the first documentation that assumed survival of 98% inside barges during yearling Chinook salmon smolt transport appears to be justified. Survival of other species or stocks by barge or for any species/stock by truck remains unknown.

13 HYDRO ENERGY↗

Reaching Grid Parity Using BP Solar Crystalline Silicon Technology: A Systems Class Application

The primary target market for this program was the residential and commercial PV markets, drawing on BP Solar's premium product and service offerings, brand and marketing strength, and unique routes to market. These two markets were chosen because: (1) in 2005 they represented more than 50% of the overall US PV market; (2) they are the two markets that will likely meet grid parity first; and (3) they are the two market segments in which product development can lead to the added value necessary to generate market growth before reaching grid parity. Federal investment in this program resulted in substantial progress toward the DOE TPP target, providing significant advancements in the following areas: (1) Lower component costs particularly the modules and inverters. (2) Increased availability and lower cost of silicon feedstock. (3) Product specifically developed for residential and commercial applications. (4) Reducing the cost of installation through optimization of the products. (5) Increased value of electricity in mid-term to drive volume increases, via the green grid technology. (6) Large scale manufacture of PV products in the US, generating increased US employment in manufacturing and installation. To achieve these goals BP Solar assembled a team that included suppliers of critical materials, automated equipment developers/manufacturers, inverter and other BOS manufacturers, a utility company, and University research groups. The program addressed all aspects of the crystalline silicon PV business from raw materials (particularly silicon feedstock) through installation of the system on the customers site. By involving the material and equipment vendors, we ensured that supplies of silicon feedstock and other PV specific materials like encapsulation materials (EVA and cover glass) will be available in the quantities required to meet the DOE goals of 5 to 10 GW of installed US PV by 2015 and at the prices necessary for PV systems to reach grid parity in 2015. This final technical report highlights the accomplishments of the BP Solar technical team from 2006 to the end of the project in February 2010. All the main contributors and team members are recognized for this accomplishment and their endeavors are recorded in the twelve main tasks described here.

14 SOLAR ENERGY↗

TEAMER Technical Support of Ramboll's for Numerical Modeling of WECs to Support OES Task 10: Cooperative Research and Development (Final Report)

National Technology & Engineering Solutions of Sandia, LLC (NTESS) in collaboration with the National Renewable Energy Laboratory (NREL), and with guidance from Ramboll, will perform fluid dynamics simulations to support of The Ocean Energy Systems (OES) Energy Technology Collaboration Program Task 10 Wave Energy Converters (WEC) Modelling Verification and Validation effort. Specific numerical simulations include the fixed device wave impingement studies to benchmark the performance of simulation techniques against physical testing results.

16 TIDAL AND WAVE POWER↗

Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electronic Structure, Bonding and Reactivity in f-Element Chemistry (Final Technical Report)

The proposed research aims to further develop and apply advanced inorganic spectroscopic methods to f-element systems, including well-defined compounds, in-situ generated complexes (including potentially complex mixtures) and transient species. Our long term goal is to develop and apply advanced inorganic spectroscopic methods in f-element chemistry in order to advance our understanding of electronic structure, bonding and reactivity in f-element systems up to the level currently available for d-block systems. A further goal of our program is the training and development of graduate students in the application of advanced inorganic spectroscopic methods for the study of f-element systems, which is critically underdeveloped at US academic institutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗