Deep Analysis Net with Causal Embedding for Coal-fired Power Plant Fault Detection and Diagnosis (DANCE4CFDD)

Fault detection and diagnosis is critical to power plant operation to ensure attaining high reliability while reducing operation cost. As more renewable power is introduced to the power grid, traditional fossil power plants take on the extra burden of excessive load cycling to compensate the generation variability from renewable power. Such load cycling will pose more reliability challenges to power plant operation. There are a number of challenges faced by today’s asset health management system in coal- fired (or gas) power plants: 1) high-dimensional nonlinear interaction among multiple time series measurements; 2) high measurement variance induced by operational conditions/modes; 3) variation among asset types and plant configurations; and 4) a small number of faulty events to learn from. To cope with these challenges, today’s fielded asset health management systems rely heavily on manual efforts from domain experts and hand-crafted features or rules based on domain knowledge. Despite its role in plant reliability, such a practice is costly and hinders its scalability and sustainability, particularly when a plant undergoes modifications. The objective of this project is to develop a novel end-to-end AI learning system that is trainable (i.e., the AI representation of a complex system behavior can be directly learned from properly labeled data) for accurate fault detection and root cause analysis. The ability to create a fault detection model directly from time series could alleviate the efforts associated with today’s asset management solution development. In the course of this project, we have achieved the following: Created an AI model development environment incorporating state-of-the-art neural network architectures for rapid model development and evaluation; Developed novel learning strategies for training of fault detection model; Developed special-purpose neural network architecture embedded with variable association graph aiming for better interpretability; Developed a learning strategy to leverage a small number of faulty events for enhanced fault detection capability; Conducted detailed experimental study based on public benchmark datasets and demonstrated the effectiveness of the proposed solution; and Validated the developed system with data from both a coal-fired plant boiler dynamic simulation model and real-world coal-fired power plant covering multiple asset and fault types. Overall, the project attained a technology readiness level of TRL 5 from TRL 2 at the beginning of the project.

20 FOSSIL-FUELED POWER PLANTS↗

An Electrical Modeling and Thermal Analysis Toolbox for Electrified Aircraft Propulsion Simulation

A simulation toolbox has been developed to model the electrical portions of Electrified Aircraft Propulsion (EAP) systems, including self-heating of electrical systems. Dynamic models of EAP systems often include turbomachinery, an electrical power system, and a thermal management system. These portions of the propulsion system can operate on timescales covering six orders of magnitude, which poses a challenging modeling task. Assumptions and approximations are made in an effort to capture the dynamics relevant to engine, electrical system, and thermal system interactions, while still allowing for fast simulations. These assumptions and approximations enable the electrical component models to run at the time scale of the turbomachinery, neglecting the very high frequency electrical dynamics, while demonstrating representative behavior of the end-to-end system. Thus the models execute in an acceptable time frame for what would otherwise be an extremely stiff simulation. The resulting simulations of EAP systems are appropriate for system-level control design and analysis. The objective of this paper is to present an overview of the Electrical Modeling and Thermal Analysis Toolbox (EMTAT). It will describe some of the approximations made to accommodate rapid execution, and some of the design tools that allow matching the model to component specifications. This paper will also provide some examples of EAP system modeling using EMTAT.

Mark E Bell↗

An Electrical Modeling and Thermal Analysis Toolbox for Electrified Aircraft Propulsion Simulation

A simulation toolbox has been developed to model the electrical portions of Electrified Aircraft Propulsion (EAP) systems, including self-heating of electrical systems. Dynamic models of EAP systems often include turbomachinery, an electrical power system, and a thermal management system. These portions of the propulsion system can operate on timescales covering six orders of magnitude, which poses a challenging modeling task. Assumptions and approximations are made in an effort to capture the dynamics relevant to engine, electrical system, and thermal system interactions, while still allowing for fast simulations. These assumptions and approximations enable the electrical component models to run at the time scale of the turbomachinery, neglecting the very high frequency electrical dynamics, while demonstrating representative behavior of the end-to-end system. Thus the models execute in an acceptable time frame for what would otherwise be an extremely stiff simulation. The resulting simulations of EAP systems are appropriate for system-level control design and analysis. The objective of this paper is to present an overview of the Electrical Modeling and Thermal Analysis Toolbox (EMTAT). It will describe some of the approximations made to accommodate rapid execution, and some of the design tools that allow matching the model to component specifications. This paper will also provide some examples of EAP system modeling using EMTAT.

Mark E Bell↗

Electrical Modeling and Thermal Analysis Toolbox (EMTAT) User’s Guide

A simulation toolbox has been developed to model the electrical portions of Electrified Aircraft Propulsion (EAP) systems, including self-heating of electrical systems. Dynamic models of EAP systems often include turbomachinery, an electrical power system, and a thermal management system. These portions of the propulsion system can operate on timescales covering six orders of magnitude, which poses a challenging modeling task. Assumptions and approximations are made in an effort to capture the dynamics relevant to engine, electrical system, and thermal system interactions, while still allowing for fast simulations. These assumptions and approximations enable the electrical component models to run at the time scale of the turbomachinery, neglecting the very high frequency electrical dynamics, while demonstrating representative behavior of the end-to-end system. Thus the models execute in an acceptable time frame for what would otherwise be an extremely stiff simulation. The resulting simulations of EAP systems are appropriate for system-level control design and analysis. The objective of this User's Guide is to present an overview of the usage of the Electrical Modeling and Thermal Analysis Toolbox (EMTAT). It will describe some of the approximations made to accommodate rapid execution, and some of the design tools that allow matching the model to component specifications. This paper will describe the basic usage of the software toolbox, and also provide an example of EAP system modeling using EMTAT.

Mark E. Bell↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flow Redirection and Induction in Steady State (FLORIS) Wind Plant Power Production Data Sets

This dataset contains turbine- and plant-level power outputs for 252,500 cases of diverse wind plant layouts operating under a wide range of yawing and atmospheric conditions. The power outputs were computed using the Gaussian wake model in NREL's FLOw Redirection and Induction in Steady State (FLORIS) model, version 2.3.0. The 252,500 cases include 500 unique wind plants generated randomly by a specialized Plant Layout Generator (PLayGen) that samples randomized realizations of wind plant layouts from one of four canonical configurations: (i) cluster, (ii) single string, (iii) multiple string, (iv) parallel string. Other wind plant layout parameters were also randomly sampled, including the number of turbines (25-200) and the mean turbine spacing (3D-10D, where D denotes the turbine rotor diameter). For each layout, 500 different sets of atmospheric conditions were randomly sampled. These include wind speed in 0-25 m/s, wind direction in 0 deg.-360 deg., and turbulence intensity chosen from low (6%), medium (8%), and high (10%). For each atmospheric inflow scenario, the individual turbine yaw angles were randomly sampled from a one-sided truncated Gaussian on the interval 0 deg.-30 deg. oriented relative to wind inflow direction. This random data is supplemented with a collection of yaw-optimized samples where FLORIS was used to determine turbine yaw angles that maximize power production for the entire plant. To generate this data, a subset of cases were selected (50 atmospheric conditions from 50 layouts each for a total of additional 2,500 cases) for which FLORIS was re-run with wake steering control optimization. The IEA onshore reference turbine, which has a 130 m rotor diameter, a 110 m hub height, and a rated power capacity of 3.4 MW was used as the turbine for all simulations. The simulations were performed using NREL's Eagle high performance computing system in February 2021 as part of the Spatial Analysis for Wind Technology Development project funded by the U.S. Department of Energy Wind Energy Technologies Office. The data was collected, reformatted, and preprocessed for this OEDI submission in May 2023 under the Foundational AI for Wind Energy project funded by the U.S. Department of Energy Wind Energy Technologies Office. This dataset is intended to serve as a benchmark against which new artificial intelligence (AI) or machine learning (ML) tools may be tested. Baseline AI/ML methods for analyzing this dataset have been implemented, and a link to their repository containing those models has been provided. The .h5 data file structure can be found in the GitHub repository under explore_wind_plant_data_h5.ipynb.

AI↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Grid-Forming Medium-Voltage Power Electronics Hub in a Microgrid Setting: Preprint

This paper presents the application of a new design of a multiport, modular, medium-voltage power electronics hub (M3PE-HUB) in a microgrid setting. The M3PE-HUB system was modeled in a digital real-time simulator (DRTS) and integrated into the Banshee microgrid test system. This paper presents the preliminary DRTS simulation-based results of the M3PE- HUB system connected in a test microgrid system. Verification and validation of the M3PE-HUB architecture and controls in the test microgrid setting are the primary contributions of this work. The results of the operation during the islanding and resynchronization process indicate the feasibility of the proposed architecture in a microgrid setting. This paper also presents results for a system reconfiguration use case where the M3PE- HUB was used to reconfigure the system under a fault condition.

grid forming↗

Advanced Modular Power System Fully Populated Electronics Enclosure Thermal Testing

A thermal test of an enclosure housing the AMPS electronics cards was performed. The enclosure was fully populated with 17 nonfunctioning AMPS electronics cards. Heaters were applied to the cards to simulate their operation. A cold plate was installed on the top of the case. The case was then insulated to simulate its installation within an electronics rack with the face and rear of the enclosure left open. The cold plate was connected to a chiller which provided cooling water at a fixed input temperature to the cold plate. Flow rates from the chiller of 0.0 L/min, 1.4 L/min and 1.8 L/min were tested. The test was operated at each flow rate over a range of heater power levels until the steady state temperature of the electronics cards was reached. Heater power levels from 2.5 W/card to 45 W/card were tested. The data collected was used to determine the steady state operating temperature of the cards, the temperature distribution between the cards, the time to reach steady-state temperature, the change in steady state temperature with change in heater power, the temperature distribution between the cards at the steady state condition and the heat lost to the surrounds by the enclosure. One of the main goals of the testing was to determine how much waste heat the cards could generate and still maintain a touch temperature at or below 40°C. Based on this requirement, for the 3 cooling rates tested, the maximum card waste heat that could be generated by each individual card was 3.9 W, 16.3 W and 17.6 W respectively. An analysis was also set up to provide an analytical model to estimate the card temperature under different cold plate flow rates and card heater power levels. The results off the analysis was compared to that of the experiment of the range of flow rates and power levels tested.

Anthony Colozza↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Step Towards Machine Learning-based Coherent Generator Grouping for Emergency Control Applications in Modern Power Grid

A dynamic neural network (NN) based multi-class classifier is proposed for improving online prediction of coherent generator groups (CGGs), following the occurrences of various contingencies in the power grid. This is motivated by the increasing availability of the measurements from phasor measurement units (PMUs) and the number of grouping schemes is limited. The proposed method consists of three steps. First, by performing offline simulations, a library of system dynamic responses characterized by post-contingency rotor angles and speeds of individual generators is obtained. To generate sufficient data, up to N-2 contingencies and the uncertain parameters associated with the power grid including type and location of disturbance and fault clearing times are modeled. Secondly, the training data-set is produced by generating labels for individual contingencies using a hierarchical clustering method based on rotor angle and speed data. Lastly, the dynamic NN models are trained for online applications such as emergency controls and controlled islanding. The proposed method is tested on the standard 16-generator 68-bus system to demonstrate its performance. Furthermore, the impact of the sample data lengths on the CGG numbers is evaluated. It is interesting to observe that the time domain stability behaviors can be determined by examining the changes in the CGG numbers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Examination of the Extreme Cold Weather Event Affecting the Power System in Texas - February 2021 [Slides]

This presentation examines the extreme cold weather event that affected the power system in Texas in February 2021. The Texas load-shedding events were caused by a combination of record-high demand and cold weather issues that reduced the output from all types of generation. While some wind turbines were shutting down due to cold temperatures and icing and a lack of cold-weather packages, hourly wind output was accurately predicted. Extreme weather events historically drive grid reliability. Additional examination of more extreme events is needed to understand their impacts on the power system. As a national lab, NREL has the capabilities and facilities to help the industry address these types of challenges. NREL also has significant simulation and analysis capabilities (such as NAERM) that can help understand the impacts of extreme events. NREL also developed the Advanced Research on Integrated Energy Systems (ARIES) Research Platform, which enables evaluation of technologies that smooth grid operations during events like this.

17 WIND ENERGY↗

Nonlinear Virtual Inertia Control of WTGs for Enhancing Primary Frequency Response and Suppressing Drivetrain Torsional Oscillations

Virtual inertia controllers (VICs) for wind turbine generators (WTGs) have been recently developed to compensate the reduction of inertia in power systems. However, VICs can induce drivetrain torsional oscillations of WTGs. This paper addresses this issue and develops a novel nonlinear VIC based on objective holographic feedback theory and the definition of a completely controllable system of Brunovsky type. Simulation results under various scenarios demonstrate that the proposed technique outperforms existing VICs in terms of enhancement of system frequency nadir, suppression of WTG drivetrain torsional oscillations, fast and smooth recovery of WTG rotor speed to the original maximum power point (MPP) before the disturbance as well as preventing secondary frequency dip caused by traditional VIC. The proposed technique is also able to adaptively coordinate multiple WTGs to enhance the frequency support and the dynamic performance of each WTG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cognitive-System Model for En Route Air Traffic Management

NASA Ames Research Center has been engaged in the development of advanced air traffic management technologies whose basic form is cognitive aiding systems for air traffic controller and flight deck operations. In the design and evaluation of such systems the dynamic interaction between the airborne aiding system and the ground-based aiding systems forms a critical coupling for control. The human operator is an integral control element in the system and the optimal integration of human decision and performance parameters with those of the automation aiding systems offers a significant challenge to cognitive engineering. This paper presents a study in full mission simulation and the development of a predictive computational model of human performance. We have found that this combination of methodologies provide a powerful design-aiding process. We have extended the computational model Man Machine Integrated Design and Analysis System (N13DAS) to include representation of multiple cognitive agents (both human operators and intelligent aiding systems), operating aircraft airline operations centers and air traffic control centers in the evolving airspace. The demands of this application require the representation of many intelligent agents sharing world-models, and coordinating action/intention with cooperative scheduling of goals and actions in a potentially unpredictable world of operations. The operator's activity structures have been developed to include prioritization and interruption of multiple parallel activities among multiple operators, to provide for anticipation (knowledge of the intention and action of remote operators), and to respond to failures of the system and other operators in the system in situation-specific paradigms. We have exercised this model in a multi-air traffic sector scenario with potential conflict among aircraft at and across sector boundaries. We have modeled the control situation as a multiple closed loop system. The inner and outer loop alerting structure of air traffic management has many implications that need to be investigated to assure adequate design. First, there are control and stability factors implicit in the design. As the inner loop response time approaches that of the outer loop, system stability may be compromised in that controllers may be solving a problem the nature of which has already been changed by pilot action. Second, information exchange and information presentation for both air and ground must be designed to complement as opposed to compete with each other. Third, the level of individual and shared awareness in trajectory modification and flight conformance needs to be defined. Fourth, the level of required awareness and performance impact of mixed fleet operations and failed-mode recovery must be explored.

Corker, Kevin M.↗

Computer Simulation of the VASIMR Engine

The goal of this project is to develop a magneto-hydrodynamic (MHD) computer code for simulation of the VASIMR engine. This code is designed be easy to modify and use. We achieve this using the Cactus framework, a system originally developed for research in numerical relativity. Since its release, Cactus has become an extremely powerful and flexible open source framework. The development of the code will be done in stages, starting with a basic fluid dynamic simulation and working towards a more complex MHD code. Once developed, this code can be used by students and researchers in order to further test and improve the VASIMR engine.

Garrison, David↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗