Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

A Fully Passive Daily Load-follow Operation in a Small PWR System

An innovative fully passive load-follow operation (PLFO) concept, based only on the negative reactivity feedbacks, is proposed by the authors. The new design concept requires no control rod adjustment or boron utilization for achieving load-follow operation in pressurized water reactors (PWRs). PLFO is motivated by the need for developing next-generation PWRs with enhanced power maneuvering capabilities, increased level of autonomism, and less dependence on active controllers. Enhanced power maneuvering capabilities are required to allow next-generation PWRs to actively contribute to electrical grid stability. Meanwhile, increased level of autonomism and less dependence on active controllers are required for safety and reliability of next-generation PWRs. However, developing an autonomous thermal reactor is challenging due to its strong thermal and xenon (Xe) reactivity feedback. Therefore, enhancing power maneuvering capabilities and simultaneously increasing the level of autonomy with less dependence on active controllers is very challenging in PWRs. However, PLFO is a promising solution. For the feasibility of PLFO, the coolant temperature coefficient (CTC) should be always clearly negative and this requires a soluble boron-free (SBF) coolant system. An SBF coolant system is also favorable in terms of reactor safety. Nevertheless, utilizing soluble boron in load-following operation is not favorable, as the change in boron concentration is a quite slow process. The power demand can be either regular (repeated pattern in a daily-basis) or irregular (varying demand). The feasibility of PLFO for regular demand was demonstrated by the authors in other works. This paper is dedicated for summarizing the feasibility of PLFO for irregular demand, and to point out the impact of Xe reactivity on PLFO for a varying power demand.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Overview of a Versatile Loading System for Anisotropic Material Property Characterization

Additive manufacturing, cold rolling, and other thermomechanical treatments on metals, especially HCP, can cause texture and oriented grain structures resulting in anisotropic mechanical properties. This can lead to macroscopic response that significantly deviates from isotropic assumptions which motivates studying mechanical properties in multiple directions. In addition, multiaxial loading and complex stress states overlapping the above mentioned material anisotropy can lead to unexpected outcomes. Idaho National Laboratory developed an advanced mechanical testing system to study a range of uniaxial to multiaxial stress states while measuring the anisotropic response bringing insight into the overlap between material properties and stress states. High-temperature capability and stress- or strain-controlled loading is available to enable a variety of experiment types and conditions to measure elastic, plastic, and viscoplastic properties. This poster presents the design and capabilities of this system with preliminary results highlighting the benefits of multiaxial loading and anisotropic analysis in an integrated system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Comparing Interaction Graphs on Cascading Outages under Different Loading Conditions

Interaction graphs on cascading outages of power systems provide valuable insights into how cascading outages evolve and propagate, and which components and links are critical to the propagation of cascading outages, enabling further development of mitigation strategies to support decision-making. However, the sensitivity of the interaction graph’s topology to the system’s loading condition has not been studied sufficiently. This paper compared interaction graphs under various loading conditions on the Northeastern Power Coordinating Council 140-bus system, and discovers the strong relationships between the graph topology, the cascade size distribution, and the load condition. Accordingly, three representative interaction graphs are constructed and illustrated.

Guo, Zhenping↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

Demand response of loads having thermal reserves

Systems and methods are described herein that improve grid performance by smoothing demand using thermal reserves. The smoothed demand can reduce peak loads as well as the ramp rate of demand that will otherwise require the use of inefficient, expensive generation sources. These improvements are tied to the selective switching on or off electrical loads that are coupled to thermal reserves, effectively using the thermal reserves as an energy storage mechanism. Historical data of past usage can be used to create load model and ensure that effects on customer comfort are minimized while still accomplishing the beneficial effects for the overall grid, which enables grid owners to both reduce their operational cost by avoiding expensive generation and improve system reliability by achieving more predictable power demand.

Ren, Wei↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Early Research in Load-Following Management for HPC-Nuclear Integration

With the rising demand for high performance computing (HPC) and artificial intelligence (AI) systems, maintaining a stable and efficient power supply is increasingly critical. The HPC team at Idaho National Laboratory is spearheading efforts to seamlessly integrate HPC systems with nuclear reactors. This lightning talk explores one early strategy for managing power fluctuations using software-defined controls. To effectively harness nuclear reactors for power generation, control mechanisms are essential to address the slow load-following capabilities of reactors, which are typically around 5% per minute. While this rate is sufficient for many uses, large HPC systems can experience rapid power consumption changes by tens of megawatts when jobs start or stop running. A reactor could overproduce power and match the peak power rating for the HPC system, however when the system is not running a job or a job unexpectedly stops, the load-following of the system would be affected leading to power being wasted and the likelihood of power transient occurrences increases. Controlling the increase or decrease of power consumption on these systems at the same rate as the load-following of reactors is one piece of the puzzle to properly utilizing nuclear reactors as a power source for HPC systems.

97 - MATHEMATICS AND COMPUTING↗

RF Cavities Loaded with Dielectric for Muon Facilities

This paper discusses RF cavities loaded with dielectric material that could be used in various muon collider facilities. Most of the existing pill-box cavity designs are too large in diameter to fit efficiently in the current cooling lattice designs. The paper describes novel compact dielectric loaded RF cavities designs that fit efficiently in muon cooling lattices and allow multi-frequency cavity designs in the same size cavity by changing the dielectric constant or size. The paper describes the designs of 400 and 800 MHz cavities for the (HCC) helical cooling channel. In addition to the use of the dielectric to reduce the radial size of gas-filled cavities in helical cooling channels, dielectric-loading has the potential use in vacuum cavities for suppression of dark current emission. Cavities that can be used for the phase rotation channel in the front end of a muon collider or neutrino factory are also presented.

43 PARTICLE ACCELERATORS↗

Spinning Reserve from Responsive Load

As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The elastic precursor behavior of tantalum under dynamic loading, its implications and modeling.

When elastic-plastic materials, such as metals, are subjected to moderately high strain rates or dynamic loadings, the plastic stress wave trails behind the elastic wave because of its slower wave speed. Due to the inherent time-dependent nature of the plastic deformation, the elastic precursor generally loads the material to a metastable elastic state at a stres level that is higher than the static strength of the material. This metastable state gradually relaxes to the equilibrium state and the relaxation results in the so-called precursor decay. In a recent work by Asay et al. (J. Appl. Phys., 2009), the inelastic response of annealed and cold-rolled pure polycrystalline tantalum at intermediate strain rates ({approx} 106/sec) was experimentally characterized with ramp wave loading. It was found that the precursor of the annealed tantalum showed little decay over a propagation distance of 6 mm even though the peak precursor stress was well above the static strength of the mateiral. The precursor for the cold-rolled sample was more dispersive and did not exhibit the characteristics depicted by the annealed samples. In this study, a constitutive model based on the concept of dislocation motion and generation was developed to gain insights into this somewhat unusual precursor behavior, particularly for the annealed samples, and the possible underlying deformation mechanisms for tantalum. Despite its simplicity, the model worked quite well for both the annealed and cold-rolled materials. The tantalum studied here essentially exhibits strong rate sensitivity and this behavior is modeled through the low dislocation density and the strong stress dependence of the dislocation velocity. Both of these contributions may be related to the low mobility of the screw dislocations in bcc metals. This low mobility may result from its extended, three-dimensional core structure.

36 MATERIALS SCIENCE↗

An examination of blast and impulse effects from the metal loading of explosives

Explosive compositions loaded with various metal particulates were produced and tested using a unique experimental configuration. The high explosive HMX was used as the standard and was tested over a range of mass loading fractions using tungsten and tantalum as metal additives. The diagnostics used in this set of experiments included free-field blast sensors, dynamic force sensors, time-of-arrival sensors, and a high-speed digital camera. The experimental arrangement allowed for concurrent spatial measurements of the static pressure from expanding gaseous detonation products, along with the total force from the combination of gaseous products and solid particles. The total pressure from the multi-phase products was calculated by measuring the total force applied to the surface of a newly developed force sensor. The results from the force sensor and other measurement techniques were validated against existing numerical methods. The relationship between static and dynamic pressures as a function of metal loading fraction was examined empirically at several distances from the charge for two distinct metal additives.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Interaction of Water with Carbon Fiber Reinforced Polymer Laminates under Dynamic Loading Conditions

With the aim of simulating the real conditions during the navigation, in this framework, impact tests were performed by loading CFRP laminates immersed in the water from the front side. The specimens, made by vinyl ester matrix because of the lower moisture absorption compared to the other epoxy systems, are in the presence of the water to accurately simulate the incidental impact on the hull of the vessel, immersed or partially immersed, during the navigation. It can be caused by the ice in the Arctic Ocean, by a projectile due to a terroristic attack or by debris from an explosion. The results are compared with the ones obtained by loading the laminates in pure traditional impact tests in the air. The influence of the clamping device has been tested too. The exciting results obtained on carbon fiber laminates in the air (pure traditional impact tests), water-backed (with water on the back side) and waterfront (water only on the front side) conditions at room temperature are here reported and compared. They highlighted the critical role played by the complex fluid–structure interaction.

36 MATERIALS SCIENCE↗

Investigation of Mode I Notch Toughness of Zr{sub 41.2}Ti{sub 13.8}Cu{sub 10}Ni{sub 12.5}Be{sub 22.5} Metallic Glass under Dynamic Loading Conditions

Based on dynamic three-point bending tests, the dynamic notch toughness (K{sub Q}{sup d}) of Zr{sub 41.2}Ti{sub 13.8}Cu{sub 10}Ni{sub 12.5}Be{sub 22.5} (Vit 1) bulk metallic glass (BMG) was found to be sensitive to stress intensity factor rate ( K-dot {sub Q}{sup d}), which varied from 5.21 to 31.90 MPa m{sup 1/2}. The number of shear bands (N{sub s}) in the notch tip plastic zone was quantitatively analyzed. The phenomenon wherein N{sub s} decreased with increasing loading rate was explained based on the theory of the shear transformation zone and the softening mechanism. Then, power law relationships were established among N{sub s}, K{sub Q}{sup d} and K-dot {sub Q}{sup d}. The results showed that shear bands can affect K{sub Q}{sup d} and K-dot {sub Q}{sup d} and act as a bridge connecting K{sub Q}{sup d} and K-dot {sub Q}{sup d}. The sensitivity of K{sub Q}{sup d} to K-dot {sub Q}{sup d} in BMGs can be well explained by the variation of N{sub s} with loading rate.

36 MATERIALS SCIENCE↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three-dimensional petrography of metal phases in equilibrated L chondrites: Effects of shock loading and dynamic compaction

To examine the role of impacts in the evolution of asteroids as seen through their chondritic offspring, we have performed a quantitative three dimensional (3D) study of metal grains in a suite of increasingly shocked L chondrites with synchrotron X-ray microtomography (XMT). Our data allow rigorous quantification of size-number distributions and collective morphology of Fe(Ni) metal phases in chondritic meteorites. At the resolution of our XMT measurements (8.4--17.9 {mu}m/voxel), the number of metal particles increase with higher degrees of petrographically identified shock loading, indicating a coalescing of Fe-Ni metal at or below this scale. Our results demonstrate that collective degrees of metal grain preferred orientation increase with greater degrees of impact-related compaction and shock loading. Ductile metal grains in L chondrites begin to show foliation at peak shock pressures < 5 GPa, pressures great enough to compact and indurate loosely bound chondritic material, and our results constitute evidence for multiple generations of impact events acting on the L parent body or bodies.

99 GENERAL AND MISCELLANEOUS↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗