Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load component”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Prediction of service life of aircraft structural components using the half-cycle method

The service life of aircraft structural components undergoing random stress cycling was analyzed by the application of fracture mechanics. The initial crack sizes at the critical stress points for the fatigue-crack growth analysis were established through proof load tests. The fatigue-crack growth rates for random stress cycles were calculated using the half-cycle method. A new equation was developed for calculating the number of remaining flights for the structural components. The number of remaining flights predicted by the new equation is much lower than that predicted by the conventional equation.

Ko, William L.↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

A study on the creep behavior of alloy 709 using in-situ scanning electron microscopy

In this research, an experimental evaluation of creep properties of Alloy 709 in the temperature range of 750–850 °C was undertaken. Alloy 709 is a novel austenitic stainless steel with 20% Cr and 25% Ni by wt% that was developed for application in structural components of nuclear power plants. Creep rupture tests were conducted in an in-situ heating-loading and Scanning Electron Microscope (SEM) unit equipped with Electron Backscatter Diffraction (EBSD) detector and Energy Dispersive Spectroscopy (EDS). “Real-time” creep damage mechanisms of Alloy 709 at various stresses and temperatures using a flat, un-notched sample with continuously reducing cross-section is studied so that the failure and maximum creep damage occurred at the center of the sample where the in-situ SEM imaging could be focused. Accelerated creep tests at temperatures and stresses above service conditions were performed by employing multiple blocks of constant loads where the loads were increased once the sample attained constant creep rate, indicating a secondary creep regime. This technique ensures multiple data points can be obtained from the same test, saves the time required for an otherwise long-term creep test and usage of SEM. Further, Coincident Site Lattice (CSL) boundary maps were collected as control maps before testing, and the grain boundaries were observed during the creep test to understand the effect of grain boundary character on the creep damage mechanism. Void growth, grain boundary separation, and sliding were found to be the main creep mechanisms whose rate is dependent on stress and temperature. Failure mechanisms studied on the fracture surface using SEM fractography were correlated to the sample surface observations to create complementary information to better understand the underline creep mechanism of Alloy 709.

36 MATERIALS SCIENCE↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)

Recent proliferation of distributed energy sources in distribution or sub-transmission systems necessitates close monitoring of these three-phase power grids which typically operate under unbalanced loading conditions. Unlike the transmission systems where the network equations are commonly based on the positive sequence component models, a detailed three phase model will have to be used in implementing network applications for these systems. In the specific case of the state estimator, where measurement and parameter errors may bias the solution, bad data and parameter error detection algorithms should also be incorporated. Implementing the state estimator and error detection algorithms for three-phase systems impose additional computational burden and modifications to the state estimation code. This paper proposes a practical solution to avoid these issues by using synchronized phasor measurements and modal decoupling. The previously developed parameter error detection algorithm based on the normalized Lagrange multipliers (NLM) test is applied to the measurements independently in each mode in parallel, not only saving CPU time but also avoiding new code development for a three-phase estimator. Different parameter error scenarios are created and tested to verify the effectiveness of the proposed error detection approach.

Khalili, Ramtin↗

Sensor Data Analytics and Data Quality Assessment Software

The proposed framework derives a set of quality metrics to provide critical insights into and tracking of grid operations, sensor performance, sensor longevity, and event statistics. Power grid engineers can utilize this information to identify problems with existing sensor locations and problematic power grid assets including generators, transmission lines, load centers, and substations. This information can also be used to identify unexpected/abnormal behavior of power grid components, improve power grid observability, and operational monitoring, and thus enhance real-time decision-making support system. Power grid planners can utilize this information to augment existing sensing architecture with new sensors and improve the observability of the network.

Mahapatra, Kaveri↗

SiM4DC [SWR-25-09]

SiM4DC is a suite of MATLAB/Simulink models specifically developed for simulating offline and real-time high-power charging hubs with various components such as grid-tie inverters, EVSEs, EVs, energy storage systems, renewable generation, and uncontrolled site loads.

Ucer, Emin [National Renewable Energy Laboratory (↗

Zero-CO Residential Natural Gas Furnace

Residential natural gas furnaces are widely used in the US homes. Manufacturers dedicate significant design and testing resources to meet requirements of design standards. One area of these standards is controlling flue gas carbon monoxide (CO) emissions. To more effectively reduce CO emissions at the flue, we developed a novel catalyst-assisted approach that integrated a low Pt/Rh loading acidic gas reduction (AGR) catalyst with three-way catalyst (TWC) or diesel oxidation catalyst (DOC) components. Compact catalysts were fabricated and assembled into tubular components, which can be seamlessly incorporated into the primary heat exchanger of a representative commercially available condensing furnace. The retrofitted furnace was demonstrated and tested following ANSI/ASHRAE Standard 103-2017. Experimental results showed that both AGR/TWC and AGR/DOC configurations achieved near-zero CO emissions under steady-state and cold-start conditions, compared with up to 500 ppm at a cold start and 17 ppm in a steady state in the OEM furnace. The catalyst-assisted furnaces also exhibited an annual fuel utilization efficiency improvement of more than 1.5% relative to the baseline unit, with a manageable pressure drop of 2.0−2.5 in. of water column. These results demonstrate that the catalyst-assisted approach can effectively eliminate CO emissions and improve energy efficiency. The technology has broad applicability for residential and commercial gas-fired heating systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

HYBRID Modeling of DETAIL Experimental Facility

Idaho National Laboratory continues to be at the forefront of advanced reactor systems and integrated energy systems research. Through the Thermal Energy Distribution System (TEDS) and Microreactor Agile Non-nuclear Test Bed (MAGNET) experiments in the Dynamic Energy Transport and Innovation Laboratory (DETAIL) within the Engineering Systems Laboratory, a mix of digital and physical testing systems can explore the operation of thermally and electrically integrated systems. Modeling of these systems has been done using the HYBRID modeling repository of the Integrated Energy Systems program. DETAIL also contains high temperature steam electrolysis (HTSE) units to produce hydrogen and generate the load imposed on MAGNET and TEDS. The dynamic modeling capabilities within the IES program describe the DETAIL components as-built and can be used to evaluate controls, process flows, and overall system conditions.

08 HYDROGEN↗

Lateral ring metal elastic wheel absorbs shock loading

Lateral ring metal elastic wheel absorbs practically all shock loading when operated over extremely rough terrain and delivers only a negligible shock residue to associated suspension components. The wheel consists of a rigid aluminum assembly to which lateral titanium ring flexible elements with treads are attached.

Galan, L.↗

A magnifying scratch-gage force transducer

Single-component scratch-gage transducer incorporates a unique motion magnification scheme to increase the magnitude of the load measuring scratch approximately 15 times over that of conventional models. It is small, load carrying and high in natural frequency.

Scott, C. E.↗

The use of statistical characteristics of reducer vibrations as diagnostic symptoms

The results of a statistical analysis of the vibrations of the experimental RS-1 reducer stand, with a spiral-gear transmission, operating on a closed circuit, are presented. The analysis was carried out on the Minsk-2 and Minsk-32 digital computers, with two-channel analog-digital converter, built in the Institute of the Science of Mechanics. Two-dimensional distribution patterns, conditional dispersions and dispersion ratios were calculated. The octave-band-filtered first harmonics of the tooth frequency f sub z of the vibrations at two different measurement points were considered as the components of the vibration process to be analyzed. The regression lines, corresponding to different values of the loading torque, are presented. Since it was not the gear drive parameters which were determined by diagnostic methods, but the characteristics most sensitive to change in state of the object of the investigation, the loading torque, which is the simplest and most accessible for measurement, was chosen as the condition parameter.

Balitskiy, F. Y.↗

The biological effect of prolonged radiation and ways of selecting new anti-radiation drugs effective in this kind of radiation injury

The basic characteristics of prolonged radiation - increased tolerance of radiation injury - are attributed to cellular kinetics; as dose rate is reduced, the population rate is not disturbed, particularly that of stem cells which makes it possible for the organism to tolerate higher radiation loads. It is concluded that this effect makes approved radio protectors, whose effect contains an established cytostatic component, unsuitable for prolonged radiation. It is better to correct the stem pool formation process by either accelerating the proliferation of cells or limiting the effect of stimuli causing cells to lose colony forming properties.

Rogozkin, V. D.↗

Low-EMI solid-state relay

Solid state relay electromagnetic interference (EMI) generated when switching ac power to load. Relay could find uses in circuits that are particularly susceptible to electrical noise or contain sensitive components.

Muska, W. D.↗

Design and evaluation of low-cost laminated wood composite blades for intermediate size wind turbines: Blade design, fabrication concept, and cost analysis

As part of a program to reduce wind turbine costs, an evaluation was conducted of a laminated wood composite blade for the Mod-OA 200 kW wind turbine. The effort included the design and fabrication concept for the blade, together with cost and load analyses. The blade structure is composed of laminated Douglas fir veneers for the primary spar and nose sections, and honeycomb cored plywood panels for the trailing edges sections. The attachment of the wood blade to the rotor hub was through load takeoff studs bonded into the blade root. Tests were conducted on specimens of the key structural components to verify the feasibility of the concept. It is concluded that the proposed wood composite blade design and fabrication concept is suitable for Mod-OA size turbines (125-ft diameter rotor) at a cost that is very competitive with other methods of manufacture.

Lieblein, S.↗

Alterations in gut transport of minerals and in binding proteins during simulated weightlessness

The structural components of the skeleton develop and are maintained in a 1 g environment, shaped by the mechanical load to which they are constantly exposed. Altering such a mechanical load by reducing the gravitational force imposed on the system, as in space flight, has profound effects on the skeleton and permits an exploration of the molecular events which regulate normal skeletal homeostasis. The objective was to determine whether simulated weightlessness reduced intestinal calcium transport, and if so, to determine the molecular mechanisms for such an effect. A nonstressful tail suspension in which the rats gained weight normally while suspended was used to simulate weightlessness. A significant change in intestinal calcium transport was not demonstrated. However, a cyclic change in bone formation with suspension was shown. Based on these observations, the objective changed to determination of the hormonal regulation of bone formation during simulated weightlessness.

Bikle, D. D.↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3, full-scale power plant development

A 25 cell stack of the 13 inch x 23 inch cell size (about 4kW) remains on test after 6000 hours, using simulated reformate fuel. A similar stack was previously shut down after 7000 hours on load. These tests were carried out for the purpose of assessing the durability of fuel cell stack components developed through the end of 1983. In light of the favorable results obtained, a 25kW stack that will contain 175 cells of the same size is being constructed using the same technology base. The components for the 25kW stack have been completed. A methanol steam reformer with a design output equivalent to 50kW has been constructed to serve as a hydrogen generator for the 25kW stack. This reformer and the balance of the fuel processing sub system are currently being tested and debugged. The stack technology development program focused on cost reduction in bipolar plates, nonmetallic cooling plates, and current collecting plates; more stable cathode catalyst support materials; more corrosion resistant metal hardware; and shutdown/start up tolerance.

Kaufman, A.↗

Emitted vibration measurement device and method

This invention is directed to a method and apparatus for measuring emitted vibrational forces produced by a reaction wheel assembly due to imbalances, misalignment, bearing defects and the like. The apparatus includes a low mass carriage supported on a large mass base. The carriage is in the form of an octagonal frame having an opening which is adapted for receiving the reaction wheel assembly supported thereon by means of a mounting ring. The carriage is supported on the base by means of air bearings which support the carriage in a generally frictionless manner when supplied with compressed air from a source. A plurality of carriage brackets and a plurality of base blocks provided for physical coupling of the base and carriage. The sensing axes of the load cells are arranged generally parallel to the base and connected between the base and carriage such that all of the vibrational forces emitted by the reaction wheel assembly are effectively transmitted through the sensing axes of the load cells. In this manner, a highly reliable and accurate measurment of the vibrational forces of the reaction wheel assembly can be had. The output signals from the load cells are subjected to a dynamical analyzer which analyzes and identifies the rotor and spin bearing components which are causing the vibrational forces.

Gisler, G. L.↗