Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Lower hybrid heating of ionospheric ions due to ion ring distributions in cusp

The stability of H(+) and H(++) ring distributions which have been observed downflowing into the cusp on the DE and S3-3 satellites is examined in the context of the feedback of those instabilities on plasma of ionospheric origin consisting of (H(+) and O(+). Lower hybrid waves are excited by the ring distributions in three distinct phases of wave-particle interaction: linear growth, trapping, and quasi-linear diffusion.The latter phase accounts for most particle heating. Including background O(+) and/or a He(++) ring introduces new modes not present in a pure H(+) plasma which play an important role in heating heavier ions. O(+) is heated significantly more by a He(++) ring than a H(+) ring of comparable energy density. It is suggested that lower hybrid waves generated by downflowing ion ring distributions play a role in energizing ion conics in the cusp.

Roth, I.↗

Ion optics for high power 50-cm-diam ion thrusters

The process used at the NASA-Lewis to fabricate 30 and 50-cm-diameter ion optics is described. The ion extraction capabilities of the 30 and 50-cm diameter ion optics were evaluated on divergent field and ring-cusp discharge chambers and compared. Perveance was found to be sensitive to the effects of the type and power of the discharge chamber and to the accelerator electrode hole diameter. Levels of up to 0.64 N and 20 kW for thrust and input power, respectively, were demonstrated with the divergent-field discharge chamber. Thruster efficiencies and specific impulse values up to 79 percent and 5000 sec., respectively, were achieved with the ring-cusp discharge chamber.

Rawlin, Vincent K.↗

Effects of ion two-stream instability on auroral ion heating

The ion two-stream instability develops between upflowing H(+) and O(+) in the auroral acceleration region, if the two species are accelerated to different velocities in a semistationary electrostatic potential. Parallel propagating modes are unstable only for small relative drifts, while oblique modes remain unstable at larger drifts and, consequently, higher altitudes. The effects of oblique modes on ion heating are investigated, and it is found that O(+) heats primarily by trapping in the direction of wave propagation during the early, coherent phase of wave growth in the temporal evolution problem. After undergoing trapping along the magnetic field direction, H(+) heats primarily by quasi-linear diffusion when the spectrum broadens nonlinearly. The parallel ion distributions evolve by formation of a high-energy (low-energy) tail on oxygen (hydrogen) along with bulk slowing of hydrogen, which results in more energetic oxygen than hydrogen. Total heating is greatest in the direction of wave propagation, and this effect is greater for hydrogen than for oxygen.

Roth, I.↗

Plasma wave, magnetic field and energetic ion observations in the ion pick-up region of Comet Giacobini-Zinner

Simultaneous plasma wave, magnetic field, and energetic ion observations made by the ICE spacecraft in the extended ion pick-up region surrounding comet Giacobini-Zinner are examined to determine the conditions under which two characteristic wave emissions, electrostatic waves at a few kHz, and electromagnetic waves at a few tens of Hz, are generated. The data are consistent with the view that the kHz electrostatic emissions result from an instability of the pick-up photoelectron 'beam' produced when the angle alpha between the magnetic field and the solar wind velocity vector is less than about 60 deg, while the behavior of the tens of Hz electromagnetic waves suggests that they are generated by the pick-up ion 'ring' which is present when alpha exceeds about 60 deg.

Richardson, I. G.↗

Ion optics for high power 50-cm-dia ion thrusters

The process used at the NASA Lewis Research Center to fabricate 30 and 50-cm-diameter ion optics is described. The ion extraction capabilities of the 30 and 50-cm diameter ion optics were evaluated on divergent field and ring-cusp discharge chambers and compared. Perveance was found to be sensitive to the effects of the type and power of the discharge chamber and to the accelerator electrode hole diameter. Levels of up to 0.64 N and 20 kW for thrust and input power, respectively, were demonstrated with the divergent-field discharge chamber. Thruster efficiencies and specific-impulse values up to 79 percent and 5000 seconds, respectively, were achieved with the ring-cusp discharge chamber.

Rawlin, Vincent K.↗

Frictional behavior and adhesion of Ag and Au films applied to aluminum oxide by oxygen-ion assisted Screen Cage Ion Plating (SCIP)

A modified dc-diode ion plating system, by utilizing a metallic screen cage as a cathode, is introduced for coating nonconductors such as ceramics. Screen cage ion plating (SCIP) is used to apply Ag and Au lubricating films on aluminum oxide surfaces. This process has excellent ability to coat around corners to produce three-dimensional coverage of the substrate. A dramatic increase in adhesion is achieved when plating is performed in a reactive 50 percent O2 - 50 percent Ar glow discharge compared to the adhesion when plating is performed in 100 percent Ar. The presence of oxygen ion assistance contributes to the excellent adhesion as measured in a pull-type adhesion tester. The Ag and Au film adhesion is significantly increased (less than 70MPa) and generally exceeds the cohesion of the substrate such that portions of the alumina are pulled out.

Spalvins, Talivaldis↗

Solid Phase Luminescence of Several Rare Earth Ions on Ion-Exchange Films

The development and characterization of a novel ion-exchange film for solid-phase fluorometry and phosphorimetry is reported. This new cation-exchange material is suitable for spectroscopic applications in the ultraviolet and visible regions. It is advantageous because it, as a single entity, is easily recovered from solution and mounted in the spectrofluorometers. After preconcentration on the film, the luminescence intensity of lanthanide ions is several orders of magnitude greater than that of the corresponding solution, depending on the volume of solution and the amount of film. This procedure allows emission spectral measurements and determination of lanthanide ions at solution concentrations of < 5 (micro)g/L. The film may be stored for subsequent reuse or as a permanent record of the analysis. The major drawback to the use of the film is slow uptake of analyte due to diffusion limitations.

Tanner, Stephen P.↗

Measurement of Doubly Charged Ions in Ion Thruster Plumes

The ratio of doubly to singly charged ions was measured in the plumes of a 30 cm and of a 40 cm ion thruster. The measured ratio was correlated with observed erosion rates and thruster operating conditions. The measured and calculated erosion rates paralleled variation in the j(sup ++)/j(sup +) ratio and indicated that the erosion was dominated by Xe III. Simple models of cathode potential surfaces which were developed in support of this work were in agreement with this conclusion and provided a predictive capability of the erosion given the ratio of doubly to singly charged ion currents.

Williams, George J., Jr.↗

Ring Current Ion Coupling with Electromagnetic Ion Cyclotron Waves

A new ring current global model has been developed that couples the system of two kinetic equations: one equation describes the ring current (RC) ion dynamic, and another equation describes wave evolution of electromagnetic ion cyclotron waves (EMIC). The coupled model is able to simulate, for the first time self-consistently calculated RC ion kinetic and evolution of EMIC waves that propagate along geomagnetic field lines and reflect from the ionosphere. Ionospheric properties affect the reflection index through the integral Pedersen and Hall conductivities. The structure and dynamics of the ring current proton precipitating flux regions, intensities of EMIC global RC energy balance, and some other parameters will be studied in detail for the selected geomagnetic storms.

Khazanov. G. V.↗

Ring Current Ion Coupling with Electromagnetic Ion Cyclotron Waves

A new ring current global model has been developed for the first time that couples the system of two kinetic equations: one equation describes the ring current (RC) ion dynamic, and another equation describes wave evolution of electromagnetic ion cyclotron waves (EMIC). The coupled model is able to simulate, for the first time self-consistently calculated RC ion kinetic and evolution of EMIC waves that propagate along geomagnetic field lines and reflect from the ionosphere. Ionospheric properties affect the reflection index through the integral Pedersen and Hall coductivities. The structure and dynamics of the ring current proton precipitating flux regions, intensities of EMIC, global RC energy balance, and some other parameters will be studied in detail for the selected geomagnetic storms. The space whether aspects of RC modelling and comparison with the data will also be discussed.

Khazanov, George V.↗

On Alfvenic Waves and Stochastic Ion Heating with 1Re Observations of Strong Field-aligned Currents, Electric Fields, and O+ ions

The role that the cleft/cusp has in ionosphere/magnetosphere coupling makes it a very dynamic region having similar fundamental processes to those within the auroral regions. With Polar passing through the cusp at 1 Re in the Spring of 1996, we observe a strong correlation between ion heating and broadband ELF (BBELF) emissions. This commonly observed relationship led to the study of the coupling of large field-aligned currents, burst electric fields, and the thermal O+ ions. We demonstrate the role of these measurements to Alfvenic waves and stochastic ion heating. Finally we will show the properties of the resulting density cavities.

Coffey, Victoria↗

Ion Propulsion Thruster Including a Plurality of Ion Optic Electrode Pairs

Ion optics for use in a conventional or annular or other shaped ion thruster are disclosed including a plurality of planar, spaced apart ion optic electrode pairs sized to include a diameter smaller than the diameter of thruster exhaust and retained in, on or otherwise associated with a frame across the thruster exhaust. An electrical connection may be provided for establishing electrical connectivity among a set of first upstream electrodes and an electrical connection may be provided for establishing electrical connectivity among the second downstream electrodes.

Patterson, Michael J.↗

Device for separating non-ions from ions

A device for separating non-ions from ions is disclosed. The device includes a plurality of electrodes positioned around a center axis of the device and having apertures therein through which the ions are transmitted. An inner diameter of the apertures varies in length. At least a portion of the center axis between the electrodes is non-linear.

47 OTHER INSTRUMENTATION↗

Rechargeable metal-ion battery with non-aqueous hybrid ion electrolyte

A method is provided for forming a rechargeable metal-ion battery with a non-aqueous hybrid ion electrolyte. The method provides a transition metal hexacyanometallate (TMHCM) cathode (AXM1YM2Z(CN)N.MH2O), where “A” is from a first group of metals, and M1 and M2 are transition metals. The electrolyte includes a first type of cation from the first group of metals, different than “A”. The method connects the cathode and anode to external circuitry to perform initial charge/discharge operations. As a result, a hybrid ion electrolyte is formed including the first type of cation and “A” cations. Subsequently, cations are inserted into the anode during charging, which alternatively may be only “A” cations, only the first type of cation, or both the “A” cations and the first type of cation. Only “A” cations, only the first type, or both “A” and the first type of cation are inserted into the TMHCM during discharge.

Wang, Long↗

Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry as a Platform for Characterizing Multimeric Membrane Protein Complexes

Membrane protein characterization is consistently hampered by challenges with expression, purification, and solubilization. Among several biophysical techniques employed for their characterization, native-mass spectrometry (MS) has emerged as a powerful tool for the analysis of membrane proteins and complexes. Here, two MS platforms, the FT-ICR and Q-ToF, have been explored to analyze the homotetrameric water channel protein, AquaporinZ (AqpZ), under non-denaturing conditions. This 97 kDa membrane protein complex can be readily liberated from the octylglucoside (OG) detergent micelle under a range of instrument conditions on both MS platforms. Increasing the applied collision energy of the FT-ICR collision cell yielded varying degrees of tetramer (97 kDa) liberation from the OG micelles, as well as dissociation into the trimeric (72 kDa) and monomeric (24 kDa) substituents. Tandem-MS on the Q-ToF yielded higher intensity tetramer signal and, depending on the m/z region selected, the observed monomer signal varied in intensity. Precursor ion selection of an m/z range above the expected protein signal distribution, followed by mild collisional activation, is able to efficiently liberate AqpZ with a high S/N ratio. The tetrameric charge state distribution obtained on both instruments demonstrated superpositioning of multiple proteoforms due to varying degrees of N-terminal formylation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Native Top-Down Mass Spectrometry and Ion Mobility MS for Characterizing the Cobalt and Manganese Metal Binding of α-Synuclein Protein

Structural characterization of intrinsically disordered proteins (IDPs) has been a major challenge in the field of protein science due to limited capabilities to obtain full-length high-resolution structures. Native ESI-MS with top-down MS was utilized to obtain structural features of protein-ligand binding for the Parkinson’s disease-related protein, α-synuclein (αSyn), which is natively unstructured. Binding of heavy metals has been implicated in the accelerated formation of αSyn aggregation. Using high-resolution Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry, native top-down MS with various fragmentation methods, including electron capture dissociation (ECD), collisional activated dissociation (CAD), and multistage tandem MS (MS{sup 3}), deduced the binding sites of cobalt and manganese to the C-terminal region of the protein. Ion mobility MS (IM-MS) revealed a collapse toward compacted states of αSyn upon metal binding. The combination of native top-down MS and IM-MS provides structural information of protein-ligand interactions for intrinsically disordered proteins. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Native Ion Mobility Mass Spectrometry: When Gas-Phase Ion Structures Depend on the Electrospray Charging Process

Ion mobility spectrometry (IMS) has become popular to characterize biomolecule folding. Numerous studies have shown that proteins that are folded in solution remain folded in the gas phase, whereas proteins that are unfolded in solution adopt more extended conformations in the gas phase. Here, we discuss how general this tenet is. We studied single-stranded DNAs (human telomeric cytosine-rich sequences with CCCTAA repeats), which fold into an intercalated motif (i-motif) structure in a pH-dependent manner, thanks to the formation of C–H{sup +}–C base pairs. As i-motif formation is favored at low ionic strength, we could investigate the ESI-IMS-MS behavior of i-motif structures at pH ~ 5.5 over a wide range of ammonium acetate concentrations (15 to 100 mM). The control experiments consisted of either the same sequence at pH ~ 7.5, wherein the sequence is unfolded, or sequence variants that cannot form i-motifs (CTCTAA repeats). The surprising results came from the control experiments. We found that the ionic strength of the solution had a greater effect on the compactness of the gas-phase structures than the solution folding state. This means that electrosprayed ions keep a memory of the charging process, which is influenced by the electrolyte concentration. We discuss these results in light of the analyte partitioning between the droplet interior and the droplet surface, which in turn influences the probability of being ionized via a charged residue-type pathway or a chain extrusion-type pathway. .

74 ATOMIC AND MOLECULAR PHYSICS↗