Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Detecting Weak Coupling of Quantum Systems with a Nonequilibrium Fano Resonance

A critical aspect of quantum mechanics is the nonlocal nature of the wavefunction, a characteristic that may yield unexpected coupling of nominally-isolated systems. The capacity to detect this coupling can be vital in many situations, especially those in which its strength is weak. In this work we address this problem in the context of mesoscopic physics, by implementing an electron-wave realization of a Fano interferometer using pairs of coupled quantum point contacts (QPCs). Within this scheme, the discrete level required for a Fano resonance is provided by pinching off one of the QPCs, thereby inducing the formation of a quasi-bound state at the center of its self-consistent potential barrier. Using this system, we demonstrate a form of $\textit{nonequilibrium}$ Fano resonance (NEFR), in which nonlinear electrical biasing of the interferometer gives rise to pronounced distortions of its Fano resonance. Our experimental results are captured well by a quantitative theoretical model, which considers a system in which a standard two-path Fano interferometer is coupled to an additional, $\textit{intruder}$, continuum. According to this theory, the observed distortions in the Fano resonance arise $\textit{only}$ in the presence of coupling to the intruder, indicating that the NEFR provides a sensitive means to infer the presence of weak coupling between mesoscopic systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Macroscopic dark matter detection with gravitational wave experiments

We study signatures of macroscopic dark matter (DM) in current and future gravitational wave (GW) experiments. Transiting DM with a mass of ~10 5 –10 15 kg that saturates the local DM density can be potentially detectable by GW detectors, depending on the baseline of the detector and the strength of the force mediating the interaction. In the context of laser interferometers, we derive the gauge invariant observable due to a transiting DM, including the Shapiro effect (gravitational time delay accumulated during the photon propagation), and adequately account for the finite photon travel time within an interferometer arm. In particular, we find that the Shapiro effect can be dominant for short-baseline interferometers such as Holometer and GQuEST. Here, we also find that proposed experiments such as Cosmic Explorer and Einstein Telescope can constrain a fifth force between DM and baryons, at the level of strength ~10 3 times stronger than gravity for, e.g., kg mass DM with a fifth-force range of 10 6 m.

79 ASTRONOMY AND ASTROPHYSICS↗

Atom Interferometry in a Warm Vapor

Here, we demonstrate matter-wave interference in a warm vapor of rubidium atoms. Established approaches to light-pulse atom interferometry rely on laser cooling to concentrate a large ensemble of atoms into a velocity class resonant with the atom optical light pulse. In our experiment, we show that clear interference signals may be obtained without laser cooling. This effect relies on the Doppler selectivity of the atom interferometer resonance. Lastly, this interferometer may be configured to measure accelerations, and we demonstrate that multiple interferometers may be operated simultaneously by addressing multiple velocity classes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD) between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL) pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. In conclusion, this is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Sensing of Yeast Cell Species and Viability

We report the development of a simple interferometer-based microwave sensing system for multiple frequency characterization and differentiation of in-flow yeast cells. The interferometer uses a simple microstrip line, integrated with a microfluidic channel, for single-cell measurement. An algorithm was developed and verified with high-frequency structure simulator (HFSS) for complex permittivity, ε*( f ) = ε'( f ) - jε"(f), extraction from measured scattering parameters. The sensing system and the algorithm were evaluated by measuring polystyrene particles of different diameters and at different interferometer operating frequencies. Viable and nonviable Saccharomyces cerevisiae and Saccharomyces pastorianus cells were measured at those frequencies. The results showed frequency-dependent permittivity values for each species of yeast and viability as well as frequency-dependent permittivity differences between different yeast types. The differences at some frequency points are significant and enable the differentiation of cells in mixed suspension, which is also demonstrated with a prediction model developed in this work.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrabroadband two-dimensional electronic spectroscopy in the pump–probe geometry using conventional optics

We report ultrabroadband two-dimensional electronic spectroscopy (2D ES) measurements obtained in the pump–probe geometry using conventional optics. A phase-stabilized Michelson interferometer provides the pump-pulse delay interval,τ 1 , necessary to obtain the excitation-frequency dimension. Spectral resolution of the probe beam provides the detection-frequency dimension,ω 3 . The interferometer incorporates active phase stabilization via a piezo stage and feedback from interference of a continuous-wave reference laser detected in quadrature. To demonstrate the method, we measured a well-characterized laser dye sample and obtained the known peak structure. The vibronic peaks are modulated as a function of the waiting time,τ 2 , by vibrational wave packets. The interferometer simplifies ultrabroadband 2D ES measurements and analysis.

Optics↗

Development of a Multi-Point Microwave Interferometry (MPMI) Method

A multi-point microwave interferometer (MPMI) concept was developed for non-invasively tracking a shock, reaction, or detonation front in energetic media. Initially, a single-point, heterodyne microwave interferometry capability was established. The design, construction, and verification of the single-point interferometer provided a knowledge base for the creation of the MPMI concept. The MPMI concept uses an electro-optic (EO) crystal to impart a time-varying phase lag onto a laser at the microwave frequency. Polarization optics converts this phase lag into an amplitude modulation, which is analyzed in a heterodyne interferometer to detect Doppler shifts in the microwave frequency. A version of the MPMI was constructed to experimentally measure the frequency of a microwave source through the EO modulation of a laser. The successful extraction of the microwave frequency proved the underlying physical concept of the MPMI design, and highlighted the challenges associated with the longer microwave wavelength. The frequency measurements made with the current equipment contained too much uncertainty for an accurate velocity measurement. Potential alterations to the current construction are presented to improve the quality of the measured signal and enable multiple accurate velocity measurements.

42 ENGINEERING↗

Experimental Constraints of the Exotic Shearing of Space-Time

The Holometer program is a search for rst experimental evidence that space-time has quantum structure. The detector consists of a pair of co-located 40-m power-recycled interferometers whose outputs are read out synchronously at 50 MHz, achieving sensitivity to spatiallycorrelated uctuations in dierential position on time scales shorter than the light-crossing time of the instruments. Unlike gravitational wave interferometers, which time-resolve transient geometrical disturbances in the spatial background, the Holometer is searching for a universal, stationary quantization noise of the background itself. This dissertation presents the nal results of the Holometer Phase I search, an experiment congured for sensitivity to exotic coherent shearing uctuations of space-time. Measurements of high-frequency cross-spectra of the interferometer signals obtain sensitivity to spatially-correlated eects far exceeding any previous measurement, in a broad frequency band extending to 7.6 MHz, twice the inverse light-crossing time of the apparatus. This measurement is the statistical aggregation of 2.1 petabytes of 2-byte dierential position measurements obtained over a month-long exposure time. At 3 signicance, it places an upper limit on the coherence scale of spatial shear two orders of magnitude below the Planck length. The result demonstrates the viability of this novel spatially-correlated interferometric detection technique to reach unprecedented sensitivity to coherent deviations of space-time from classicality, opening the door for direct experimental tests of theories of relational quantum gravity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum Random Walk Simulator Using Ultrafast Optical Switches

Quantum random walk processes have many intriguing applications in high energy physics including the simulation of parton shower evolution. We will present the design and initial results of a fiber loop time-bin quantum walk architecture using the hardware platform already in operation at the Fermilab Quantum Network in which the state of the photon is defined by its time-of-arrival. The fiber loop consists of an unbalanced Mach-Zehnder interferometer implemented using an ultrafast electro-optical switch. The input switch controls the photon path within the interferometer, while the output switch will direct the photon back into the interferometer or to single photon detectors to measure the probability distribution of arrival times. Depending on which path the photon takes each pass through the loop, its wave function will interfere on these optical switches similar to quantum interference on a beam splitter. This work is an important step towards utilizing real-world advantages of quantum information protocols to solve problems in high energy physics.

Cameron, Andrew [Fermilab]↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

Interferometric rotation sensor

An interferometric rotation sensor and control system is provided which includes a compound prism interferometer and an associated direction control system. Light entering the interferometer is split into two paths with the light in the respective paths being reflected an unequal number of times, and then being recombined at an exit aperture in phase differing relationships. Incoming light is deviated from the optical axis of the device by an angle, alpha. The angle causes a similar displacement of the two component images at the exit aperture which results in a fringe pattern. Fringe numbers are directly related to angle alpha. Various control systems of the interferometer are given.

Walsh, T. M.↗

Optical Signal Processing: Poisson Image Restoration and Shearing Interferometry

Optical signal processing can be performed in either digital or analog systems. Digital computers and coherent optical systems are discussed as they are used in optical signal processing. Topics include: image restoration; phase-object visualization; image contrast reversal; optical computation; image multiplexing; and fabrication of spatial filters. Digital optical data processing deals with restoration of images degraded by signal-dependent noise. When the input data of an image restoration system are the numbers of photoelectrons received from various areas of a photosensitive surface, the data are Poisson distributed with mean values proportional to the illuminance of the incoherently radiating object and background light. Optical signal processing using coherent optical systems is also discussed. Following a brief review of the pertinent details of Ronchi's diffraction grating interferometer, moire effect, carrier-frequency photography, and achromatic holography, two new shearing interferometers based on them are presented. Both interferometers can produce variable shear.

Hong, Yie-Ming↗

Doppler shift system

A system is described for measuring velocities of radiating particles based on Doppler shift. Light from the particles is directed through a narrow band optical filter to a Fabry-Perot interferometer initially tuned to a selected center line corresponding to zero particle Doppler shift. The movable mirror of the interferometer is made to sweep about the center line by the output of a modulation oscillator. The fringe pattern output is imaged onto a pin hole through which light is directed to a photomultiplier. The output of the photomultiplier is supplied to a phase sensitive detector with the oscillator output as a reference signal and which operates in the quadrature mode. The detector's output is gain controlled and is combined with the oscillator's output to adjust the interferometer's movable mirror to acquire the line center.

Aisenberg, S.↗

Very Long Baseline Interferometry (VLBI) earth physics

The characteristics of the Michelson/Pease stellar interferometer are discussed. An analog of the interferometer using radio waves is described. The use of a conventional hard-wired interferometer with very long base line interferometry (VLBI) is analyzed. Mathematical models are developed to analyze the VLBI techniques. A summary of VLBI geodetic experiments is tabulated. The concept and application of the astronomical radio interferometric earth surveys (ARIES) are reported. A schematic diagram of ARIES implementation is provided.

Macdoran, P. F.↗

Research in millimeter wave techniques

During the past six months, efforts on this project have been devoted to: (1) continuation of construction and testing of a 6 GHz subharmonic mixer model with extension of the pumping frequency of this mixer to omega sub s/4, (2) construction of a 183 GHz subharmonic mixer based on the results of tests on this 6 GHz model, (3) ground-based radiometric measurements at 183 GHz, (4) fabrication and testing of wire grid interferometers, (5) calculations of reflected and lost power in these interferometers, and (6) calculations of the antenna temperature due to water vapor to be expected in down-looking radiometry as a function of frequency. Significant events during the past six months include: (1) Receipt of a 183 GHz single-ended fundamental mixer, (2) attainment of 6 db single sideband conversion loss with the 6 GHz subharmonic mixer model by using a 1.5 GHz (omega sub s/4) pump frequency, (3) additional ground-based radiometric measurements and (4) derivation of equations for reflection and loss for wire grid interferometers.

Mcmillan, R. W.↗

A high declination search at 8 GHz for compact radio sources

With the Haystack-NRAO interferometer (baseline length of 20 million wavelengths at 3.8 cm) 37 sources were observed whose declinations were above 50 deg. Seven of these sources have compact cores with diameters smaller than 5 milliarcsec and with correlated flux densities greater than about 0.5 Jy; the remaining sources have no cores with flux densities above about 0.3 Jy, the sensitivity limit of the interferometer. Two of the sources with detected compact cores, 4C 67.05 and 3C 418, were also observed with longer-baseline interferometers; the diameter of the core of 4C 67.05 was estimated to be smaller than 1 milliarcsec and that of 3C 418 to be smaller than 0.4 milliarcsec. All diameter estimates were based on an assumed circular Gaussian distribution of radio brightness and refer to the contour with brightness density e to the -1/2 power times that of the center. Positions for the detected sources were also obtained from the interferometric data, the uncertainty in these coordinate estimates ranging from 0.04 to 0.6 arcsec. The compact core detected in 3C 390.3 was found to lie near the center of this extended (approximately 4 arcmin in diameter) double radio source and to be coincident to within 1 arcsec with an N galaxy previously identified with 3C 390.3.

Wittels, J. J.↗