Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Adorym: a multi-platform generic X-ray image reconstruction framework based on automatic differentiation

We describe and demonstrate an optimization-based X-ray image reconstruction framework called Adorym. Our framework provides a generic forward model, allowing one code framework to be used for a wide range of imaging methods ranging from near-field holography to fly-scan ptychographic tomography. By using automatic differentiation for optimization, Adorym has the flexibility to refine experimental parameters including probe positions, multiple hologram alignment, and object tilts. It is written with strong support for parallel processing, allowing large datasets to be processed on high-performance computing systems. We demonstrate its use on several experimental datasets to show improved image quality through parameter refinement.

36 MATERIALS SCIENCE↗

Design of monolithic piezoelectric bimorph mirrors made from lithium niobate

Recent advances in deformable mirrors based on monolithic piezoelectric substrates, such as lithium niobate, have the potential to improve the image quality of X-ray optical systems on synchrotron and free-electron laser beamlines and microscopes. However, the quantitative relationship between design parameters and the deformed shape has not been readily available in the literature. We present an analytical model, validated through finite element analysis, enabling calculation of tangential and sagittal curvatures based on mirror dimensions, crystallographic orientation, and applied voltage. We demonstrate that through the selection of material orientation, it is possible to achieve different deformed shapes (sphere, cylinder, or hyperbolic paraboloid). This methodology can be generalized to other piezoelectric materials and substrate-integrated actuator systems.

Marzari, Francesco [University of Trento (Italy); ↗

Porotomo: InSAR Data from San Emidio Geothermal Field, Nevada, 1992-2010

This submission contains tarred pair directories for interferometric synthetic aperture radar (InSAR) data covering San Emidio Geothermal Field in Nevada, USA as part of the porotomo project. Data included within this submission are the following: > ENVI_T120_GDR.tgz: Tarred directory containing 39 Envisat track 120 tarred, pair subdirectories spanning from 2003-Oct-29 to 2010-Jun-09. > ENVI_T27_GDR.tgz: Tarred directory containing 32 Envisat track 27 tarred, pair subdirectories spanning from 2004-Jun-23 to 2010-Apr-28. > ERS_T27_GDR.tgz: Tarred directory containing 35 ERS track 27 tarred, pair subdirectories spanning from 1992-Jun-07 to 2000-Sep-27. > ENVI_T27_SQR_drange_utm_cut.grd: SqueeSAR-derived data product for Enivsat track 27 from Eneva, et al. (2011) (provided by TRE Altamira) in terms of unwrapped range change rate. > MSTvsSQR_GDR.tgz: Tarred directory containing Easting gradient files for each satellite and track corresponding to the MST data products and the SqueeSAR data products. > sanem_dem_utm.grd: Digital elevation model (DEM) used in the creation of the interferograms. Explanation of pair subdirectories (contained within ENVI_T120_GDR, ENVI_T27_GDR, ERS_T27_GDR): Pairs are chosen based on a minimum spanning tree (MST) algorithm with image quality (as measured by the amount of phase noise within an interferometric pair) as the weighting criterion. Pairs are formed using the InSAR processing software GMT5SAR (Sandwell et al., 2011). Pair subdirectories are named by starting and ending epochs in YYYYMMDD_YYYYMMDD format. Each tarred pair directory contains GRD files for wrapped phase data (radians) and wrapped phase data after application of a modified Goldstein filter that depends on coherence (Goldstein & Werner, 1997; Baran et al., 2003; Sandwell et al., 2011). The data are given in both latitude/longitude and Universal Transverse Mercator (Zone 11N). Raw Synthetic Aperture Radar (SAR) data from the Envisat and ERS satellite missions operated by the European Space Agency (ESA) are copyrighted by ESA and were provided through the WInSAR consortium at the UNAVCO facility.

15 GEOTHERMAL ENERGY↗

Research and Development Toward Massive Liquid Argon Time Projection Chambers for Neutrino Detection

Liquid argon (LAr) time projection chambers (TPC) have rapidly increased in importance as particle detectors throughout the past four decades. While much research has been completed, there are still many areas which require further development to build and operate the next generation LAr TPC experiment, such as the Deep Underground Neutrino Experiment (DUNE). These include high voltage breakdown, argon purification and purity monitoring, and vacuum ultraviolet (VUV) scintillation light measurement. Visual monitoring of high voltage breakdown is helpful in allowing assessment of the performance of high voltage component design. Thus, a system of cryogenic cameras, the first of its kind, was developed for use in a large LAr cryostat, without the need for additional electronics heating. The system functioned without problem for 50 days at cryogenic temperature, with some degradation of image quality, and provided a useful monitor for the DUNE 35-ton cryogenics systems. The system did not observe any high voltage breakdowns during the run. Further development of the concept is ongoing for future installation in other experiments. The monitoring of LAr purity using TPC data is a fundamental study for LAr TPC experiments. However, the study has not been performed for a large LAr TPC in the presence of high electronic noise. Custom software was developed and validated for the accurate reconstruction of signals in noisy TPC data. The results of the reconstruction were used to successfully measure the LAr electron lifetime with an uncertainty comparable to alternate methods of measurement. The electron lifetime of the 35-ton Phase II run is determined to be 4.12 ± 0.17 (stat.) ±0.40 (syst.) ms. For general purpose research and development of high purity LAr as a particle detection medium, a dedicated test stand was designed, constructed, and commissioned. The system is used to test the gaseous photomultiplier (GPM) performance at cryogenic temperatures. The GPM functions with photoelectron multiplication at 77 K, at a reduced gain. Further study is required to show the detector’s direct sensitivity to LAr VUV scintillation light.

Thiesse, Matthew↗

Initial Investigation of the Small Feature Detection Capability of the ORNL Fast Neutron Tomographic Imaging System

A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a version of the Oak Ridge National Laboratory fast neutron tomographic imaging system. Two image quality indicators were examined: (1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder, and (2) a variety of short steels pins embedded radially in the surface of a polyethylene cylinder. Measurements demonstrated detectability of about 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution. Our current simulation code takes only partial consideration of the DT generator neutron production spot size, with neutron production effectively originating at a single point. Simulations showed that features less than 2 mm should be detectable with an improved generator. Our current ING-27 DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor at present. Generators with spot sizes as small as 1 mm are commercially available. Higher-power, small–spot size associated particle generators are at the prototype stage and are expected to be commercially available soon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Analysis of M9 Linatron Scatter V Leakage

The M9 Linatron exhibited the following two problems: 1) Dose rates during operation, and 2) Image quality. To design adequate shielding to resolve both of these issues, we need to determine whether Primary beam scatter or head leakage is the primary contributor to dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Computed Tomography Imaging of Printed Circuit Boards

Nondestructive inspection of printed circuit boards (PCB) can be efficiently carried out with xray Computed Tomography (XCT). However, image artifacts can obscure some of the PCB details. As a demonstration of LLNL’s XCT capabilities, an internally-funded effort was recently executed that acquired XCT data for a PCB. These data were reconstructed with both traditional and physics-based iterative techniques to illustrate the use of advanced algorithms to reduce artifacts and thus improve image quality.

42 ENGINEERING↗

Low Size, Weight, and Power Space-Based Imaging System

The proposed low-SWAP solution is a FPA focus mechanism which is composed of an actuator motor, attached to a flexure that holds the camera sensor while imaging. The mechanism, while moderately complex, allows for large changes in the focal plane while also maintaining the ability to make small adjustments to produce the best possible data. This solution does the best job at accounting for thermal gradients within the optical components that tend to degrade the image quality.

42 ENGINEERING↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

Optimization of scintillated imaging detectors for MeV X-ray radiography

Radiographic imaging at X-ray energies in the MeV range poses a complex problem. Detection of high energy X-rays depends heavily on the ability of the detection material, in this work the scintillator, to attenuate and ultimately stop the X-ray. Attenuation is more readily achieved by increasing material thickness, however thick scintillators are plagued with relatively high internal scattering, leading to an overall decrease in spatial resolution and image quality.

42 ENGINEERING↗

Structural Evolution of the Hogback Monocline and Its Tectonic Significance in the San Juan Basin

The San Juan Basin is recognized as a Laramide foreland basin. It is located within the Colorado Plateau, a broad tectonic province characterized by a thick sedimentary sequence that was segmented into smaller sub basins during the Late Cretaceous to Paleogene Laramide orogeny. The Hogback Monocline lies along the northwestern margin of the San Juan Basin and is considered a Laramide-age structure formed in response to compressional stress. In this study, we interpret surface and subsurface datasets to construct a structural geological model and evaluate its tectonic significance. Through seismic data, we identify key fault and fold geometries at depth. The seismic dataset used in this study was reprocessed in depth and constrained with well log velocity data to enhance seismic imaging quality. Additionally, we performed well log correlations to identify formation tops and assess variations in basin infill and thickness geometry. A series of structural cross-sections, constructed using seismic data and a high density of boreholes, are presented to evaluate geometric variations along the structure and its evolution during basin development. Furthermore, kinematic restoration and forward modeling analyses were conducted to validate our structural interpretation. This work suggests that the Hogback Monocline formed through fault-propagation folding and flexural slip affecting the pre-Laramide sedimentary sequence under compressional stresses associated with the Laramide orogeny. This structure is interpreted as a high-angle reverse fault that influenced the geometry of the late basin infill. Additionally, monocline bending along the structure may have been controlled by fault relay systems and, in some cases, influenced by strike-slip faulting.

Reyes, Martin [New Mexico Bureau o fGeology and Mi↗

Simulation Study of Monoenergetic Photon Source LiDAR System Performance for Emergency Response Applications

The following report summarizes the results of a Monte Carlo simulation and modeling study of the Lawrence Berkeley National Laboratory’s (LBL) Monoenergetic Photon Source (MPS) as part of a high-energy LiDAR system for use in emergency response applications. A set of image quality indicators (IQI) and nonsensitive phantoms or generalized surrogates for search targets have been identified for use in the planned measurement campaign at the Berkeley Lab Laser Accelerator (BELLA) Center toward the end FY2023. These items were modeled and the time-of-flight (TOF) spectral responses following irradiation were calculated for a set of varying operating conditions. The goal of this study was to both predict the LiDAR system performance as well as determine if minor modifications to the IQI and phantom designs were required before fabrication. It was found that the IQI and target designs both overlap and extend towards the limit of performance of the system and are thus suitable for the final project measurement campaign.

43 - PARTICLE ACCELERATORS↗

Chromium Grain-boundary Segregation and Effect of Ion Beam Cleaning on Fe-Ni-Cr Alloys

The grain boundaries play important role to control the mechanical strength of ternary alloys. From spacecrafts to naval vessels to nuclear reactors, stress corrosion cracking, brittleness, oxidation mostly originates at the grain boundaries and cause long term structural stability problems in most of the metallic structures [1]. Fe-Ni-Cr based ternary metal alloys have been widely studied for more than fifty years [2, 3]. Despite of vast amount of research, chromium diffusion in stainless steel or other Ni-Fe-Cr based ternary alloys is still an open scientific problem with challenges in structural stability and corrosion resistance [4]. Particularly, austenite Fe-Ni-Cr is looked upon favorably in space and jet engine industry for their improved resistance to stress corrosion cracking [5]. In solid oxide fuel cells (SOFC), Ni-alloys are frequently used as interconnects and seals [6]. In this communication, simultaneous energy dispersive spectroscopy (EDS) and electron backscatter diffraction (EBSD) mapping is utilized to study chemical and structural aspects of chromium segregation in Fe-Ni-Cr alloy. A focused Ga-ion beam is also utilized to study the effect of ion beam cleaning on EBSD image quality (IQ) and inverse pole figure (IPF) maps of Fe-Ni-Cr alloy.

30 DIRECT ENERGY CONVERSION↗

Cryo-EM visualization of viruses from partially irrigated soils

Viruses are numerically the most abundant forms on Earth, and most are present in soil. Even though viruses are highly abundant in soil and critical to rhizosphere function, visualizing the diverse morphotypes within soil has been challenging. The difficulty is primarily due to the heterogenous nature of isolated suspensions that typically contain nanometer to micron scale debris which renders protein crystallography for structural studies unfeasible and hinders cryo-electron microscopy due to ice thickness and contrast issues. Here we employed and compared a simple spin filtration method to cleanup solutions of extracted viruses for direct observation with cryo-electron microscopy. The method employs common physical biochemical separation steps to remove large and small debris which dramatically improves image quality and preservation of structural features to permit visualizing morphotypes not typically seen with conventional negative stain approaches. In addition to tailed and non-tailed polyhedral phages, several under reported or novel morphotypes of soil viruses are directly visualized as a particle library with both 2D and 3D information.

cryo-EM↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

PREPARING FOR ADVANCED LIGO: A STAR–GALAXY SEPARATION CATALOG FOR THE PALOMAR TRANSIENT FACTORY

The search for fast optical transients, such as the expected electromagnetic counterparts to binary neutron star mergers, is riddled with false positives (FPs) ranging from asteroids to stellar flares. While moving objects are readily rejected via image pairs separated by ∼1 hr, stellar flares represent a challenging foreground, significantly outnumbering rapidly evolving explosions. Identifying stellar sources close to and fainter than the transient detection limit can eliminate these FPs. Here, we present a method to reliably identify stars in deep co-adds of Palomar Transient Factory (PTF) imaging. Our machine-learning methodology utilizes the random forest (RF) algorithm, which is trained using >3×10{sup 6} sources with Sloan Digital Sky Survey (SDSS) spectra. When evaluated on an independent test set, the PTF RF model outperforms the SExtractor star classifier by ∼4%. For faint sources (r{sup ′}⩾21 mag), which dominate the field population, the PTF RF model produces a ∼19% improvement over SExtractor. To avoid false negatives in the PTF transient-candidate stream, we adopt a conservative stellar classification threshold, corresponding to a galaxy misclassification rate of 0.005. Ultimately, ∼1.70×10{sup 8} objects are included in our PTF point-source catalog, of which only ∼10{sup 6} are expected to be galaxies. We demonstrate that the PTF RF catalog reveals transients that otherwise would have been missed. To leverage its superior image quality, we additionally create an SDSS point-source catalog, which is also tuned to have a galaxy misclassification rate of 0.005. These catalogs have been incorporated into the PTF real-time pipelines to automatically reject stellar sources as non-extragalactic transients.

79 ASTRONOMY AND ASTROPHYSICS↗

The Star Formation Across Cosmic Time (SFACT) Survey. II. The First Catalog from a New Narrowband Survey for Emission-line Objects

Star Formation Across Cosmic Time (SFACT) is a new narrowband (NB) survey designed to detect faint emission-line galaxies (ELGs) and QSOs over a broad range of redshifts. Here we present the first list of SFACT candidates from our pilot-study fields. Using the WIYN 3.5 m telescope, we are able to achieve good image quality with excellent depth and routinely detect ELGs to r = 25.0. The limiting line flux of the survey is ~1.0 × 10 –16 erg s –1 cm –2 . SFACT targets three primary emission lines: Hα, [O III ] λ5007, and [O II ] λ3727. The corresponding redshift windows allow for the detection of objects at z ~ 0–1. With a coverage of 1.50 deg 2 in our three pilot-study fields, a total of 533 SFACT candidates have been detected (355 candidates deg –2 ). We detail the process by which these candidates are selected in an efficient and primarily automated manner, then tabulate accurate coordinates, broadband photometry, and NB fluxes for each source.

79 ASTRONOMY AND ASTROPHYSICS↗