Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

The Atmospheric Chemistry and Climate Model Intercomparison Project (ACCMIP): Overview and Description of Models, Simulations and Climate Diagnostics

The Atmospheric Chemistry and Climate Model Intercomparison Project (ACCMIP) consists of a series of time slice experiments targeting the long-term changes in atmospheric composition between 1850 and 2100, with the goal of documenting composition changes and the associated radiative forcing. In this overview paper, we introduce the ACCMIP activity, the various simulations performed (with a requested set of 14) and the associated model output. The 16 ACCMIP models have a wide range of horizontal and vertical resolutions, vertical extent, chemistry schemes and interaction with radiation and clouds. While anthropogenic and biomass burning emissions were specified for all time slices in the ACCMIP protocol, it is found that the natural emissions are responsible for a significant range across models, mostly in the case of ozone precursors. The analysis of selected present-day climate diagnostics (precipitation, temperature, specific humidity and zonal wind) reveals biases consistent with state-of-the-art climate models. The model-to- model comparison of changes in temperature, specific humidity and zonal wind between 1850 and 2000 and between 2000 and 2100 indicates mostly consistent results. However, models that are clear outliers are different enough from the other models to significantly affect their simulation of atmospheric chemistry.

humidity↗

Climate Drivers of Global Wildfire Burned Area

Wildfire is an integral part of the Earth system, but at the same time it can pose serious threats to human society and to certain types of terrestrial ecosystems. Meteorological conditions are a key driver of wildfire activity and extent, which led to the emergence of the use of fire danger indices that depend solely on weather conditions. The Canadian Fire Weather Index (FWI) is a widely used fire danger index of this kind. Here, we evaluate how well the FWI, its components, and the climate variables from which it is derived, correlate with observation-based burned area (BA) for a variety of world regions. We use a novel technique, according to which monthly BA are grouped by size for each Global Fire Emissions Database (GFED) pyrographic region. We find strong correlations of BA anomalies with the FWI anomalies, as well as with the underlying deviations from their climatologies for the four climate variables from which FWI is estimated, namely, temperature, relative humidity, precipitation, and wind. We quantify the relative sensitivity of the observed BA to each of the four climate variables, finding that this relationship strongly depends on the pyrographic region and land type. Our results indicate that the BA anomalies strongly correlate with FWI anomalies at a GFED region scale, compared to the strength of the correlation with individual climate variables. Additionally, among the individual climate variables that comprise the FWI, relative humidity and temperature are the most influential factors that affect the observed BA. Our results support the use of the composite fire danger index FWI, as well as its sub-indices, the Build-Up Index (BUI) and the Initial Spread Index (ISI), comparing to single climate variables, since they are found to correlate better with the observed forest or non-forest BA, for the most regions across the globe.

Wildfire↗

Proton Exchange Membranes for Fuel Cells

Proton exchange membrane, also known as polymer electrolyte membrane, fuel cells (PEMFCs) offer the promise of efficient conversion of chemical energy of fuel, such as hydrogen or methanol, into electricity with minimal pollution. Their widespread use to power zero-emission automobiles as part of a hydrogen economy can contribute to enhanced energy security and reduction in greenhouse gas emissions. However, the commercial viability of PEMFC technology is hindered by high cost associated with the membrane electrode assembly (MEA) and poor membrane durability under prolonged operation at elevated temperature. Membranes for automotive fuel cell applications need to perform well over a period comparable to the life of an automotive engine and under heavy load cycling including start-stop cycling under sub-freezing conditions. The combination of elevated temperature, changes in humidity levels, physical stresses and harsh chemical environment contribute to membrane degradation. Perfluorinated sulfonic acid (PFSA)-based membranes, such as Nafion®, have been the mainstay of PEMFC technology. Their limitations, in terms of cost and poor conductivity at low hydration, have led to continuing research into membranes that have good proton conductivity at elevated temperatures above 120 °C and under low humidity conditions. Such membranes have the potential to avoid catalyst poisoning, simplify fuel cell design and reduce the cost of fuel cells. Hydrocarbon-based membranes are being developed as alternatives to PFSA membranes, but concerns about chemical and mechanical stability and durability remain. Novel anhydrous membranes based on polymer gels infused with protic ionic liquids have also been recently proposed, but considerable fundamental research is needed to understand proton transport in novel membranes and evaluate durability under fuel cell operating conditions. In order to advance this promising technology, it is essential to rationally design the next generation of PEMs based on an understanding of chemistry, membrane morphology and proton transport obtained from experiment, theory and computer simulation.

08 HYDROGEN↗

Optimal Synthesis of a Pulverized Coal Power Plant with Carbon Capture

Coal constitutes an important source of fuel for the production of power in the United States. For instance, in January 2009, pulverized coal (PC) power plants alone contributed to over 45 percent of the Nation's total electric power production. However, PC power plants also contribute to increased emissions of greenhouse gases principally carbon-dioxide (CO2). Recently, various carbon capture strategies have been under active investigation so as to make these plants compete with the more environmental friendly renewable energy sources. One such technology that has received considerable success is the capture of CO2 by an amine-based solvent extraction process. However, an aqueous absorption/stripping technology when used in a PC power plant can reduce the net power output of the plant by as much as 20-40%. The energy penalty comes from heating up the solvent in the regenerator, balancing the enthalpy of reaction, and water stripping. This energy penalty poses considerable limitations on commercial viability of the solvent extraction process and, as a result, various energy-saving modifications have been proposed in the literature ranging from the use of hybrid solvents to novel stripper configurations. In this paper, we show that the energy penalty can be further reduced by heat integration of various PC plant components with the carbon capture system. In addition to the release of greenhouse gases to the environment, PC plants also consume a large amount of freshwater. It is estimated that subcritical and supercritical PC plants have water losses of 714 gal/MWh and 639 gal/MWh, respectively. Water loss is based on an overall balance of the plant source and exit streams. This includes coal moisture, air humidity, process makeup, cooling tower makeup (equivalent to evaporation plus blowdown), process losses (including losses through reactions, solids entrainment, and process makeup/blowdown) and flue gas losses. The primary source of water used in PC power plants is the closed-loop steam-based (Rankine) power cycles. These plants need to condense large quantities of low-pressure steam back to water so that it can be reused to produce high pressure steam. However, this requires the removal of large quantities of heat from the low pressure steam in the condensation process. This is usually done by transferring the heat to cooling water, which in turn transfers this heat to the environment by evaporation to the atmosphere. Also, the inclusion of a carbon capture process can increase the raw water usage by as much as 95 percent. In this work, we use heat exchanger network synthesis followed by an optimization approach to process synthesis for developing strategies for reducing water use in a supercritical PC power plant with a carbon capture and compression system. Uncertainties associated with dry bulb temperature, relative humidity, and demand will also be considered in this analysis.

01 COAL, LIGNITE, AND PEAT↗

Building America Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet)

As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed-humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowner's wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ASME AG-1 Section FC Qualified HEPA Filters; a Particle Loading Comparison - 13435

High Efficiency Particulate Air (HEPA) Filters used to protect personnel, the public and the environment from airborne radioactive materials are designed, manufactured and qualified in accordance with ASME AG-1 Code section FC (HEPA Filters) [1]. The qualification process requires that filters manufactured in accordance with this ASME AG-1 code section must meet several performance requirements. These requirements include performance specifications for resistance to airflow, aerosol penetration, resistance to rough handling, resistance to pressure (includes high humidity and water droplet exposure), resistance to heated air, spot flame resistance and a visual/dimensional inspection. None of these requirements evaluate the particle loading capacity of a HEPA filter design. Concerns, over the particle loading capacity, of the different designs included within the ASME AG-1 section FC code[1], have been voiced in the recent past. Additionally, the ability of a filter to maintain its integrity, if subjected to severe operating conditions such as elevated relative humidity, fog conditions or elevated temperature, after loading in use over long service intervals is also a major concern. Although currently qualified HEPA filter media are likely to have similar loading characteristics when evaluated independently, filter pleat geometry can have a significant impact on the in-situ particle loading capacity of filter packs. Aerosol particle characteristics, such as size and composition, may also have a significant impact on filter loading capacity. Test results comparing filter loading capacities for three different aerosol particles and three different filter pack configurations are reviewed. The information presented represents an empirical performance comparison among the filter designs tested. The results may serve as a basis for further discussion toward the possible development of a particle loading test to be included in the qualification requirements of ASME AG-1 Code sections FC and FK[1]. (authors)

42 ENGINEERING↗

A Thermal Model for the Performance Analysis of Large Scale Spent Fuel Cooling Pond - 19173

This paper presents a thermal model for the performance analysis of a large scale cooling pond for the long term storage of spent nuclear fuel. The model has been developed using the knowledge gained from fundamental investigation using CFD and has been validated by comparing against reliable experimental and/or numerical data. It was then applied in the context of operation of a large scale pond to ascertain the sensitivity of various operational and environmental conditions. To develop the model, the water body along with the heating elements was considered as one zone and humid air inside the building as another zone, both of which are considered as well-mixed zones. Various input conditions namely, total heat load from the heat source, environmental temperature and relative humidity, ventilation rate, efficiency of the cooling tower, recirculation and make-up water flow rates have been programmed in the model. The statistical method AVONA has been used to assess the influence of the above variables. The results reveal that the efficiency of the cooling tower is the most influential parameter on the cooling performance of cooling pond within the considered values of heat load. It has also been found that the majority of the heat is taken by the recirculating water for very high heat load while the other modes of heat transfer are small but not insignificant. The model is capable of simulating the scenario of loss of cooling water and suggests that it can be used for managing a large pond efficiently as well as recovery from an accident situation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemistry and Reactivity of Oxide Films on Aluminum Clad Test Reactor Fuels - 19294

This paper describes recent work performed to assess the degradation of aluminum spent nuclear fuel (ASNF) as part of an ongoing Department of Energy project. As part of a multi-task effort, this paper specifically describes efforts initiated in 2018 to better understand chemical phenomena and degradation in ASNF). In this paper experimental and modeling activities are described. The modeling effort presents initial results in two areas potentially influencing stability. Using an established electrolyte model based on experimental data, the solubility of aluminum as a function of temperature and pH was examined. This work describes interesting results for the minimum pH providing relevant data that was not available from the literature. It was found that solubility increases with temperature and that the minimum pH shifts to low pH with increase in temperature. The second area involves understanding the metallurgy of aluminum alloys during fuel drying. In this study, the temperature range from 100 deg. C to 300 deg. C was analyzed. Thermodynamic models predict that AA1100 will not experience significant phase changes while the more highly alloyed AA6061 and AA5052 may experience significant phase changes. These thermodynamic measurements establish a potential for phase changes during drying, however they do not predict the kinetics for such processes. Phase 1 of the experimental program has initiated and results are forthcoming. The test program will examine aluminum oxidation under anticipated dry storage conditions (temperature and humidity). Examination of localized corrosion due to tight crevices and galvanic contact (with stainless steel) will be included. Finally, water deliquescence will be assessed using thermogravimetric analysis with dynamic humidity profiles. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concoction and Appraisal of Radiation Hardened Polyurethane Foams for DOE Decontamination and Decommissioning (D and D) Operations

Since World War 2, a number of nuclear facilities have been relocating their nuclear waste to long term storage, or final disposition. These facilities face monumental challenges in cleaning up the fixated transferrable radioactive waste that is left in these facilities after initial cleaning operations have ended. SRNL has identified a solution that is utilizing two-part epoxy foams with heavy metal additives for fixating and shielding transferable radioactive material that has accumulated in non uniform volumes. The purpose of this experiment is to make a library of data of physical characteristics of each foam and additive combination that will have data concerning how the material cures and performs in different environments with varying temperatures and how it will act and perform after being irradiated. Materials Being Tested: - Foam iT 7FR, Foam iT 23FR, 3M Fire Barrier foam, and Hilti CP620 foam; - Additives Bi, Bi2O{sub 3}, Na{sub 2}WO{sub 3}, and WO{sub 3} at 12.5% and 25%. What's being investigated: - Expansion data from each foam; - Radiation shielding data for each foam combination; - Peak temperatures for each foam. Utilized a FLIR thermal camera to find peak temperature and time it took the foam to reach it. No noticeable difference in volume or weight after blank foam samples sat in the environmental chamber for 24 hours except the 3M foam at the extreme relative humidity of 90% highlighted above. The more additives used in the foam, the more they were able to shield. The foams begin to saturate around 100% wt% where more additive used will not increase the shielding capability of the foam. Similar thermal dispersion in blanks and in samples with Bi additive. Time taken to peak temperature is very similar between the two. Similar peak temperatures in blanks and in Bi samples. Hilti had slightly elevated temperatures. All foams maintained their physical properties post environmental chamber except the 3M foam. With the increased sponginess from the high relative humidity's, 3M may be disqualified for further testing if its mechanical properties also suffer. While curing all foams had their peak temperature occur between 40 deg. C and 70 deg. C except the Hilti which occurred above 90 deg. C with and without additive. With this information, no foams would be disqualified. After radiation shielding studies, it was found that IT 14 with Bismuth and Bismuth Oxide Additives provided the best shielding of Co-60 with over 9% attenuation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deliquescence and efflorescence of small particles: Unifying perspectives from nucleation theory

We examine size dependent deliquescence/efflorescence phase transformation for particles down to several nanometers in size. A thin layer criterion (TLC) is introduced to define a deliquescence relative humidity (DRH) for small particles. The usual bulk deliquescence conditions are recovered in the limit of large dry particle size. Nano-size particles are shown to deliquesce to metastable states via a nucleation process at relative humidity just below the DRH. The nucleation barrier is located at a critical solution layer thickness and vanishes at the DRH defined by the TLC. Methods from nucleation theory form the basis for the analysis and yield new insights into the theory, facilitate the interpretation of measurements, and point to unification of deliquescence and efflorescence processes for particles in the nano regime. Methods include thermodynamic area constructions, Legendre transforms relating the binary free-energy surfaces for deliquescence and efflorescence processes, and application of nucleation theorems.

54 ENVIRONMENTAL SCIENCES↗

The influence of clouds and diffuse radiation on ecosystem-atmosphere CO2 and CO18O exhanges

This study evaluates the potential impact of clouds on ecosystem CO{sub 2} and CO{sub 2} isotope fluxes ('isofluxes') in two contrasting ecosystems (a broadleaf deciduous forest and a C{sub 4} grassland), in a region for which cloud cover, meteorological, and isotope data are available for driving the isotope-enabled land surface model, ISOLSM. Our model results indicate a large impact of clouds on ecosystem CO{sub 2} fluxes and isofluxes. Despite lower irradiance on partly cloudy and cloudy days, predicted forest canopy photosynthesis was substantially higher than on clear, sunny days, and the highest carbon uptake was achieved on the cloudiest day. This effect was driven by a large increase in light-limited shade leaf photosynthesis following an increase in the diffuse fraction of irradiance. Photosynthetic isofluxes, by contrast, were largest on partly cloudy days, as leaf water isotopic composition was only slightly depleted and photosynthesis was enhanced, as compared to adjacent clear sky days. On the cloudiest day, the forest exhibited intermediate isofluxes: although photosynthesis was highest on this day, leaf-to-atmosphere isofluxes were reduced from a feedback of transpiration on canopy relative humidity and leaf water. Photosynthesis and isofluxes were both reduced in the C{sub 4} grass canopy with increasing cloud cover and diffuse fraction as a result of near-constant light limitation of photosynthesis. These results suggest that some of the unexplained variation in global mean {delta}{sup 18}O of CO{sub 2} may be driven by large-scale changes in clouds and aerosols and their impacts on diffuse radiation, photosynthesis, and relative humidity.

54 ENVIRONMENTAL SCIENCES↗

High temperature fuel cell membranes based on poly(arylene ether)s containing benzimidazole groups

Development of new high-performance polymer membranes that retain their proton conductivity under low humidity conditions is one of the most critical requirements to commercialize PEMFC systems. Current sulfonated proton exchange membranes acquire proton conductivity by water that solvates ion and carries proton. Consequently, a loss of water under low RH conditions immediately results in a loss of proton conductivity. One approach to maintain proton conductivity under low RH conditions is to replace water with a less volatile proton solvent. Kreuer has pointed out the possibility to develop fully polymeric proton-conducting membranes based on nitrogen-containing heterocycles such as imidazole, benzimidazole, and pyrazole. We have attempted to blend those less volatile proton solvent with sulfonated copolymers such as polystyrene sulfonic acid, Nafion, poly(arylene ether sulfone, BPSH-xx). [Ref. DOE review meeting 2007 and 2008] However, we observed that imidazole was slowly sublimated out as temperature and humidity increases which could cause poisoning of electro-catalyst, corrosion and losing conductivity. In this presentation, we report the synthesis of novel poly(arylene ether sulfone)s containing benzimidazole groups These benzimidazole containing polymer was blended with sulfonated poly(arylene ether sulfone). In the blend system, benzimidazole group attached to the polysulfone acts as a medium through the basic nitrogen for transfer of protons between the sulfonic acid groups. Proton conductivity of the blend membranes was investigated as a function of water content at 80 C and compared the performance with water based proton conduction system.

36 MATERIALS SCIENCE↗

Merged Sounding VAP Version 2.0

The Merged Sounding Value-Added Product (VAP) has been in the ARM and ASR pipeline since 2001. Output data streams have been added to the Evaluation Products section of the ARM website for the past five years. Currently, there are data for all of the ACRF fixed sites and all deployments of the Mobile Facility. Fifty-three years of Merged Sounding data is available as an evaluation product. The process of moving all to the ARM Data Archive has been started and will be completed shortly. A second version of the Merged Sounding VAP was developed to address several concerns: (1) Vaisala radiosondes have inherent problems obtaining an accurate measurement of relative humidity, (2) the profile can be extended from 20 km to 60 km above ground level based upon the height achieved by ECMWF profiles, and (3) ECMWF temperatures require adjustments at high altitude (between 1mb and 100 mb). Solutions to these issues have been incorporated in the new version of this VAP. Along with producing that second version of Merged Sounding, a secondary data stream - Sonde Adjust - was created. This VAP incorporates any humidity corrections to the Vaisala RS-80, RS-90, and RS-92 radiosondes. The algorithms used to perform these corrections are documented by Wang et. al. (2002), Turner et. al. (2003), and Miloshevich et. al. (2004, 2009).

54 ENVIRONMENTAL SCIENCES↗

Scale dependence of entrainment-mixing mechanisms in cumulus clouds

This work empirically examines the dependence of entrainment-mixing mechanisms on the averaging scale in cumulus clouds using in situ aircraft observations during the Routine Atmospheric Radiation Measurement Aerial Facility Clouds with Low Optical Water Depths Optical Radiative Observations (RACORO) field campaign. A new measure of homogeneous mixing degree is defined that can encompass all types of mixing mechanisms. Analysis of the dependence of the homogenous mixing degree on the averaging scale shows that, on average, the homogenous mixing degree decreases with increasing averaging scales, suggesting that apparent mixing mechanisms gradually approach from homogeneous mixing to extreme inhomogeneous mixing with increasing scales. The scale dependence can be well quantified by an exponential function, providing first attempt at developing a scale-dependent parameterization for the entrainment-mixing mechanism. The influences of three factors on the scale dependence are further examined: droplet-free filament properties (size and fraction), microphysical properties (mean volume radius and liquid water content of cloud droplet size distributions adjacent to droplet-free filaments), and relative humidity of entrained dry air. It is found that the decreasing rate of homogeneous mixing degree with increasing averaging scales becomes larger with larger droplet-free filament size and fraction, larger mean volume radius and liquid water content, or higher relative humidity. The results underscore the necessity and possibility of considering averaging scale in representation of entrainment-mixing processes in atmospheric models.

54 ENVIRONMENTAL SCIENCES↗

A review of the remote sensing of lower tropospheric thermodynamic profiles and its indispensable role for the understanding and the simulation of water and energy cycles: REMOTE SENSING OF THERMODYNAMIC PROFILES

A review of remote sensing technology for lower tropospheric thermodynamic (TD) profiling is presented with focus on high accuracy and high temporal-vertical resolution. The contributions of these instruments to the understanding of the Earth system are assessed with respect to radiative transfer, land surface-atmosphere feedback, convection initiation, and data assimilation. We demonstrate that for progress in weather and climate research, TD profilers are essential. These observational systems must resolve gradients of humidity and temperature in the stable or unstable atmospheric surface layer close to the ground, in the mixed layer, in the interfacial layer—usually characterized by an inversion—and the lower troposphere. A thorough analysis of the current observing systems is performed revealing significant gaps that must be addressed to fulfill existing needs. We analyze whether current and future passive and active remote sensing systems can close these gaps. A methodological analysis and demonstration of measurement capabilities with respect to bias and precision is executed both for passive and active remote sensing including passive infrared and microwave spectroscopy, the global navigation satellite system, as well as water vapor and temperature Raman lidar and water vapor differential absorption lidar. Whereas passive remote sensing systems are already mature with respect to operational applications, active remote sensing systems require further engineering to become operational in networks. However, active remote sensing systems provide a smaller bias as well as higher temporal and vertical resolutions. For a suitable mesoscale network design, TD profiler system developments should be intensified and dedicated observing system simulation experiments should be performed.

58 GEOSCIENCES↗

Role of surface heat fluxes underneath cold pools

Abstract The role of surface heat fluxes underneath cold pools is investigated using cloud‐resolving simulations with either interactive or horizontally homogenous surface heat fluxes over an ocean and a simplified land surface. Over the ocean, there are limited changes in the distribution of the cold pool temperature, humidity, and gust front velocity, yet interactive heat fluxes induce more cold pools, which are smaller, and convection is then less organized. Correspondingly, the updraft mass flux and lateral entrainment are modified. Over the land surface, the heat fluxes underneath cold pools drastically impact the cold pool characteristics with more numerous and smaller pools, which are warmer and more humid and accompanied by smaller gust front velocities. The interactive fluxes also modify the updraft mass flux and reduce convective organization. These results emphasize the importance of interactive surface fluxes instead of prescribed flux boundary conditions, as well as the formulation of surface heat fluxes, when studying convection.

54 ENVIRONMENTAL SCIENCES↗