Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “filled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Magnetic properties and pairing tendencies of the iron-based superconducting ladder BaFe 2 S 3 : Combined ab initio and density matrix renormalization group study

The recent discovery of superconductivity under high pressure in the two-leg ladder compound BaFe 2 S 3 [H. Takahashi et al., Nat. Mater. 14, 1008 (2015)] opens a broad avenue of research, because it represents the first report of pairing tendencies in a quasi-one-dimensional iron-based high-critical-temperature superconductor. Similarly, as in the case of the cuprates, ladders and chains can be far more accurately studied using many-body techniques and model Hamiltonians than their layered counterparts, particularly if several orbitals are active. In this publication, we derive a two-orbital Hubbard model from first principles that describes individual ladders of BaFe 2 S 3 . The model is studied with the density matrix renormalization group. These first reported results are exciting for two reasons: (i) at half-filling, ferromagnetic order emerges as the dominant magnetic pattern along the rungs of the ladder, and antiferromagnetic order along the legs, in excellent agreement with neutron experiments; and (ii) with hole doping, pairs form in the strong coupling regime, as found by studying the binding energy of two holes doped on the half-filled system. In addition, orbital selective Mott phase characteristics develop with doping, with only oneWannier orbital receiving the hole carriers while the other remains half-filled. Lastly, these results suggest that the analysis of models for iron-based two-leg ladders could clarify the origin of pairing tendencies and other exotic properties of iron-based high-critical-temperature superconductors in general.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmark study of the two-dimensional Hubbard model with auxiliary-field quantum Monte Carlo method

Ground-state properties of the Hubbard model on a two-dimensional square lattice are studied by the auxiliary-field quantum Monte Carlo method. Accurate results for energy, double occupancy, effective hopping, magnetization, and momentum distribution are calculated for interaction strengths of U/t from 2 to 8, for a range of densities including half-filling and n = 0.3,0.5,0.6, 0.75, and 0.875. At half-filling, the results are numerically exact. Away from half-filling, the constrained path Monte Carlo method is employed to control the sign problem. Our results are obtained with several advances in the computational algorithm, which are described in this paper in detail. We discuss the advantages of generalized Hartree-Fock trial wave functions and its connection to pairing wave functions, as well as the interplay with different forms of Hubbard-Stratonovich decompositions. We study the use of different twist angle sets when applying the twist averaged boundary conditions. We propose the use of quasirandom sequences, which improves the convergence to the thermodynamic limit over pseudorandom and other sequences. With it and a careful finite size scaling analysis, we are able to obtain accurate values of ground-state properties in the thermodynamic limit. Detailed results for finite-sized systems up to 16 × 16 are also provided for benchmark purposes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ferromagnetism beyond Lieb's theorem

The noninteracting electronic structures of tight-binding models on bipartite lattices with unequal numbers of sites in the two sublattices have a number of unique features, including the presence of spatially localized eigenstates and flat bands. When a uniform on-site Hubbard interaction U is turned on, Lieb proved rigorously that at half-filling (ρ = 1) the ground state has a nonzero spin. In this paper we consider a “CuO 2 lattice” (also known as “Lieb lattice,” or as a decorated square lattice), in which “d orbitals” occupy the vertices of the squares, while “ p orbitals” lie halfway between two d orbitals; both d and p orbitals can accommodate only up to two electrons. We use exact determinant quantum Monte Carlo (DQMC) simulations to quantify the nature of magnetic order through the behavior of correlation functions and sublattice magnetizations in the different orbitals as a function of U and temperature; we have also calculated the projected density of states, and the compressibility. Here, we study both the homogeneous (H) case, U d = U p , originally considered by Lieb, and the inhomogeneous (IH) case, U d ≠ U p . For the H case at half-filling, we found that the global magnetization rises sharply at weak coupling, and then stabilizes towards the strong-coupling (Heisenberg) value, as a result of the interplay between the ferromagnetism of like sites and the antiferromagnetism between unlike sites; we verified that the system is an insulator for all U. For the IH system at half-filling, we argue that the case U p ≠ U d falls under Lieb's theorem, provided they are positive definite, so we used DQMC to probe the cases U p = 0, U d = U and Up = U, U d = 0. We found that the different environments of d and p sites lead to a ferromagnetic insulator when U d = 0; by contrast, U p = 0 leads to to a metal without any magnetic ordering. In addition, we have also established that at density ρ = 1/3, strong antiferromagnetic correlations set in, caused by the presence of one fermion on each d site.

36 MATERIALS SCIENCE↗

Shape of magnetic domain walls formed by coupling to mobile charges

Magnetic domain walls, which are crucially important in both fundamental physics and technical applications, often have a preference in their form due to many different origins, such as the crystalline shape, lattice symmetry, and magnetic anisotropy. Here we theoretically investigate yet another origin stemming from the coupling to mobile charges in itinerant magnets. Performing a large-scale numerical simulation in a minimal model for itinerant magnets, i.e., the Kondo lattice model with classical localized spins, we show that the shape of magnetic domain walls depends on the electronic band structure and electron filling. While Néel and 120° antiferromagnetic states do not show a strong preference in the shape of domain walls, noncoplanar spin states with scalar chiral ordering have distinct directional preferences of the domain walls depending on the electron filling. We find that the directional preference is rationalized by the wave-number dependence of the effective magnetic interactions induced by the mobile charges, which are set by the band structure and electron filling. Finally, we also observe that, in the noncoplanar chiral states, an electric current is induced along the domain walls owing to the spin Berry phase mechanism, with different spatial distributions depending on whether the bulk state is metallic or insulating.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonequilibrium relaxation and aging scaling of the Coulomb and Bose glass

We employ Monte Carlo simulations to investigate the nonequilibrium relaxation properties of the two- and three-dimensional Coulomb glass with different long-range repulsive interactions. Specifically, we explore the aging scaling laws in the two-time density autocorrelation function. We find that, in the time window and parameter range accessible to us, the scaling exponents are not universal, depending on the filling fraction and temperature: As either the temperature decreases or the filling fraction deviates more from half filling, the exponents reflect markedly slower relaxation kinetics. In comparison with a repulsive Coulomb potential, appropriate for impurity states in strongly disordered semiconductors, we observe that, for logarithmic interactions, the soft pseudogap in the density of states is considerably broader, and the dependence of the scaling exponents on external parameters is much weaker. Furthermore, the latter situation is relevant for flux creep in the disorder-dominated Bose glass phase of type-II superconductors subject to columnar pinning centers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cascades between Light and Heavy Fermions in the Normal State of Magic-Angle Twisted Bilayer Graphene

We present a framework for understanding the cascade transitions and the Landau level degeneracies of twisted bilayer graphene. The Coulomb interaction projected onto narrow bands causes the charged excitations at an integer filling to disperse, forming new bands. If the excitation moves the filling away from the charge neutrality point, then it has a band minimum at the moiré Brillouin zone center with a small mass that compares well with the experiment; if towards the charge neutrality point, then it has a much larger mass and a higher degeneracy. At a nonzero density away from an integer filling the excitations interact. The system on the small mass side has a large bandwidth and forms a Fermi liquid. On the large mass side the bandwidth is narrow, the compressibility is negative and the Fermi liquid is likely unstable. This explains the observed sawtooth features in compressibility, the Landau fans pointing away from charge neutrality and their degeneracies. The framework sets the stage for superconductivity at lower temperatures.

36 MATERIALS SCIENCE↗

Kondo Lattice Model of Magic-Angle Twisted-Bilayer Graphene: Hund’s Rule, Local-Moment Fluctuations, and Low-Energy Effective Theory

For this work, we apply a generalized Schrieffer-Wolff transformation to the extended Anderson-like topological heavy fermion (THF) model for the magic-angle (θ=1.05°) twisted bilayer graphene (MATBLG) [Phys. Rev. Lett. 129, 047601 (2022)], to obtain its Kondo lattice limit. In this limit localized $\mathcal{f}$ electrons on a triangular lattice interact with topological conduction $\mathcal{c}$ electrons. By solving the exact limit of the THF model, we show that the integer fillings ν=0, ±1, ±2 are controlled by the heavy $\mathcal{f}$ electrons, while ν=±3 is at the border of a phase transition between two $\mathcal{f}$-electron fillings. For ν=0, ±1, ±2, we then calculate the Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions between the $\mathcal{f}$ moments in the full model and analytically prove the SU(4) Hund’s rule for the ground state which maintains that two $\mathcal{f}$ electrons fill the same valley-spin flavor. Our (ferromagnetic interactions in the) spin model dramatically differ from the usual Heisenberg antiferromagnetic interactions expected at strong coupling. We show the ground state in some limits can be found exactly by employing a positive semidefinite “bond-operators” method. We then compute the excitation spectrum of the $\mathcal{f}$ moments in the ordered ground state, prove the stability of the ground state favored by RKKY interactions, and discuss the properties of the Goldstone modes, the (reason for the accidental) degeneracy of (some of) the excitation modes, and the physics of their phase stiffness. We develop a low-energy effective theory for the $\mathcal{f}$ moments and obtain analytic expressions for the dispersion of the collective modes. We discuss the relevance of our results to the spin-entropy experiments in TBG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation effects in magic-angle twisted bilayer graphene: An auxiliary-field quantum Monte Carlo study

Magic-angle twisted bilayer graphene (MATBG) presents a fascinating platform for investigating the effects of electron interactions in topological flat bands. The Bistritzer-MacDonald (BM) model provides a simplified quantitative description of the flat bands. Introducing long-range Coulomb interactions leads to an interacting BM (IBM) Hamiltonian, a momentum-space continuum description which offers a very natural starting point for many-body studies of MATBG. Accurate and reliable many-body computations in the IBM model are challenging, however, and have been limited mostly to special fillings or smaller lattice sizes. We employ a state-of-the-art auxiliary-field quantum Monte Carlo (AFQMC) method to study the IBM model, which constrains the sign problem to enable accurate treatment of large system sizes. We determine ground-state properties and quantify errors compared to mean-field theory calculations. Our calculations identify correlated metal states and their competition with the insulating Kramers intervalley-coherent state at both half-filling and charge neutrality. Additionally, we investigate one- and three-quarter fillings, and examine the effect of many-body corrections beyond single Slater determinant solutions. We discuss the effect that details of the IBM Hamiltonian have on the results, including different forms of double-counting corrections, and the need to establish and precisely specify many-body Hamiltonians to allow more direct and quantitative comparisons with experiments in MATBG. Published by the American Physical Society 2025

Xiao, Zhi-Yu (ORCID:0000000219531579)↗

Microscopic origin of temperature-dependent magnetism in spin-orbit-coupled transition metal compounds

A few 4 d and 5 d transition metal compounds with various electron fillings were recently found to exhibit magnetic susceptibilities χ and magnetic moments that deviate from the well-established Kotani model. This model has been considered for decades to be the canonical expression for descriing the temperature dependence of magnetism in systems with nonnegligible spin-orbit coupling effects. In this paper, we uncover the origin of such discrepancies and determine the applicability and limitations of the Kotani model by calculating the temperature dependence of the magnetic moments of a series of 4 d (Ru-based) and 5 d (W-based) systems at different electron fillings. For this purpose, we perform exact diagonalization of -derived relativistic multiorbital Hubbard models on finite clusters and compute their magnetic susceptibilities. Comparison with experimentally measured magnetic properties indicates that contributions such as a temperature-independent χ 0 background, crystal field effects, Coulomb and Hund's couplings, and intersite interactions—not included in the Kotani model—are especially crucial for correctly describing the temperature dependence of χ and magnetic moments at various electron fillings in these systems. Based on our results, we propose a generalized approach beyond the Kotani model to accurately describe their magnetism. Published by the American Physical Society 2025

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spaced Orthocyclic Winding Pattern for Improved Die Compressed Coils

Winding fill, coil fill, or packing factor, is critical to the performance of many types of electromagnetic devices from electric machines to actuators, transformers, inductors, etc. One technique to increase the packing of conductors in the winding area is to compress round magnet wire conductors in a die, so that they deform and air voids between coil turns are removed. The winding layout of the coil turns on a bobbin before compression has a direct impact on the achievable coil fill and the damage to the coil insulation or conductors after compression. It is thought that winding the turns in an orthocyclic pattern on the bobbin before compression would minimize damage to the turns. This however causes turns to displace during the winding compression process. A new pre-compression winding pattern is proposed, a spaced orthocyclic winding, to minimize turn displacement and damage. A design of experiments study has been carried out to optimize this winding method and to compare it to the traditional orthocyclic winding.

33 ADVANCED PROPULSION SYSTEMS↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Detector to detector corrections: A comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams

Purpose: The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Methods: Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm{sup 2} to 4.2 × 4.2 cm{sup 2} and the measurements were extended to larger fields of up to 10 × 10 cm{sup 2}. Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm{sup 3} to 0.3 cm{sup 3}). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. Results: For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm{sup 3} air filled ionization chamber and were as high as 1.924 for the 0.3 cm{sup 3} ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm{sup 3}. Conclusions: The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al{sub 2}O{sub 3}:C, or scintillators.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams

Purpose: The electron fluence inside a parallel-plate ionization chamber positioned in a water phantom and exposed to a clinical electron beam deviates from the unperturbed fluence in water in absence of the chamber. One reason for the fluence perturbation is the well-known “inscattering effect,” whose physical cause is the lack of electron scattering in the gas-filled cavity. Correction factors determined to correct for this effect have long been recommended. However, more recent Monte Carlo calculations have led to some doubt about the range of validity of these corrections. Therefore, the aim of the present study is to reanalyze the development of the fluence perturbation with depth and to review the function of the guard rings. Methods: Spatially resolved Monte Carlo simulations of the dose profiles within gas-filled cavities with various radii in clinical electron beams have been performed in order to determine the radial variation of the fluence perturbation in a coin-shaped cavity, to study the influences of the radius of the collecting electrode and of the width of the guard ring upon the indicated value of the ionization chamber formed by the cavity, and to investigate the development of the perturbation as a function of the depth in an electron-irradiated phantom. The simulations were performed for a primary electron energy of 6 MeV. Results: The Monte Carlo simulations clearly demonstrated a surprisingly large in- and outward electron transport across the lateral cavity boundary. This results in a strong influence of the depth-dependent development of the electron field in the surrounding medium upon the chamber reading. In the buildup region of the depth-dose curve, the in–out balance of the electron fluence is positive and shows the well-known dose oscillation near the cavity/water boundary. At the depth of the dose maximum the in–out balance is equilibrated, and in the falling part of the depth-dose curve it is negative, as shown here the first time. The influences of both the collecting electrode radius and the width of the guard ring are reflecting the deep radial penetration of the electron transport processes into the gas-filled cavities and the need for appropriate corrections of the chamber reading. New values for these corrections have been established in two forms, one converting the indicated value into the absorbed dose to water in the front plane of the chamber, the other converting it into the absorbed dose to water at the depth of the effective point of measurement of the chamber. In the Appendix, the in–out imbalance of electron transport across the lateral cavity boundary is demonstrated in the approximation of classical small-angle multiple scattering theory. Conclusions: The in–out electron transport imbalance at the lateral boundaries of parallel-plate chambers in electron beams has been studied with Monte Carlo simulation over a range of depth in water, and new correction factors, covering all depths and implementing the effective point of measurement concept, have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of separation.

60 APPLIED LIFE SCIENCES↗

Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy

Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % {sup 6}LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % {sup 6}LiOH solution based on the simulation results. Experimental characterization of the depth dose distributions of the neutron and gamma-ray components along the central axis was performed at Heavy Water Neutron Irradiation Facility installed at Kyoto University Reactor using activation foils and thermoluminescent dosimeters, respectively. Results: Simulation results demonstrated that the absorbing effect for thermal neutrons occurred when the LiOH concentration was over 1%. The most effective Li-6 concentration was determined to be enriched {sup 6}LiOH with a solubility approaching its upper limit. Experiments confirmed that the thermal neutron flux and secondary gamma-ray dose rate decreased substantially; however, the fast neutron flux and primary gamma-ray dose rate were hardly affected in the 10%-{sup 6}LiOH phantom. It was confirmed that the dose contribution of fast neutrons is improved from approximately 10% in the pure water phantom to approximately 50% in the 10%-{sup 6}LiOH phantom. Conclusions: The dual phantom technique using the combination of a pure water phantom and a 10%-{sup 6}LiOH phantom developed in this work provides an effective method for dose estimation of the fast neutron component in BNCT. Improvement in the accuracy achieved with the proposed technique results in improved RBE estimation for biological experiments and clinical practice.

60 APPLIED LIFE SCIENCES↗