Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Explicit Finite Element Modeling of Multilayer Composite Fabric for Gas Turbine Engine Containment Systems, Phase II: Material Model Development and Simulation of Experiments - Part 3

A team consisting of Arizona State University, Honeywell Engines, Systems & Services, the National Aeronautics and Space Administration Glenn Research Center, and SRI International collaborated to develop computational models and verification testing for designing and evaluating turbine engine fan blade fabric containment structures. This research was conducted under the Federal Aviation Administration Airworthiness Assurance Center of Excellence and was sponsored by the Aircraft Catastrophic Failure Prevention Program. The research was directed toward improving the modeling of a turbine engine fabric containment structure for an engine blade-out containment demonstration test required for certification of aircraft engines. The research conducted in Phase II began a new level of capability to design and develop fan blade containment systems for turbine engines. Significant progress was made in three areas: (1) further development of the ballistic fabric model to increase confidence and robustness in the material models for the Kevlar(TradeName) and Zylon(TradeName) material models developed in Phase I, (2) the capability was improved for finite element modeling of multiple layers of fabric using multiple layers of shell elements, and (3) large-scale simulations were performed. This report concentrates on the material model development and simulations of the impact tests.

Zylon↗

A high-resolution pseudo-polygon discrete element model for regional sea ice

Here, this work presents a pseudo-polygon discrete element model for high-resolution sea ice simulations. A scale-invariant bonded particle contact model is proposed to model joints between sea ice floes based on the smeared fracture model and a lattice spring beam model, and the Mohr–Coulomb failure criterion is implemented to represent the shearing failure mechanism of sea ice packings under complex loadings. All mechanical parameters of the bond model can be directly determined from laboratory tests. Validations of the proposed model are made by investigations of mechanical response and failure criteria of field sea ice sheets. Compared with the field observations of sea ice from satellite radar and in situ stress sensors, the proposed model is capable of reproducing the typical constitutive behavior and the Coulomb friction envelope of field sea ice. Finally, the proposed discrete element sea ice model is used to study the effect of loading rates on mechanical behavior including failure strength of regional sea ice.

54 ENVIRONMENTAL SCIENCES↗

Formulation and calibration of two-dimensional constitutive models for composite structures based on panel tests

Steel Plate Concrete (SC) composite members have been widely adopted because of its cost-efficiency and enhanced structural behavior. While researchers have attempted to study its in-plane shear behavior in the past twenty years, very limited number of large-scale pure shear tests were performed due to the challenge of experimental set-up and the availability of facilities. In this paper, a series of uniaxial loading tests and two full-scale pure shear panel tests of SC members were reported, on which the “mechanics-based Membrane Model of SC elements (MM-SC)” is developed. The MM-SC model is based on the fixed-angle crack formulation and the smeared-crack formulation, in which the experimental-based uniaxial constitutive models are implemented, considering the local buckling of faceplate, the tension stiffening of steel plate, the strength degradation of cracked concrete and the confinement effect of concrete. The proposed MM-SC model is subsequently incorporated into the object-oriented software OpenSEES. Finally, the simulation results of proposed model well predict the SC test observations in terms of critical branch points and structural behaviors, including initial stiffness, cracking strength, post-crack stiffness, yield strength, maximum strength, and failure modes.

42 ENGINEERING↗

A technique for evaluating the application of the pin-level stuck-at fault model to VLSI circuits

Accurate fault models are required to conduct the experiments defined in validation methodologies for highly reliable fault-tolerant computers (e.g., computers with a probability of failure of 10 to the -9 for a 10-hour mission). Described is a technique by which a researcher can evaluate the capability of the pin-level stuck-at fault model to simulate true error behavior symptoms in very large scale integrated (VLSI) digital circuits. The technique is based on a statistical comparison of the error behavior resulting from faults applied at the pin-level of and internal to a VLSI circuit. As an example of an application of the technique, the error behavior of a microprocessor simulation subjected to internal stuck-at faults is compared with the error behavior which results from pin-level stuck-at faults. The error behavior is characterized by the time between errors and the duration of errors. Based on this example data, the pin-level stuck-at fault model is found to deliver less than ideal performance. However, with respect to the class of faults which cause a system crash, the pin-level, stuck-at fault model is found to provide a good modeling capability.

Palumbo, Daniel L.↗

Log-Based Recovery in Asynchronous Distributed Systems

A log-based mechanism is described for restoring consistent states to replicated data objects after failures. Preserving a causal form of consistency based on the notion of virtual time is focused upon in this report. Causal consistency has been shown to apply to a variety of applications, including distributed simulation, task decomposition, and mail delivery systems. Several mechanisms have been proposed for implementing causally consistent recovery, most notably those of Strom and Yemini, and Johnson and Zwaenepoel. The mechanism proposed here differs from these in two major respects. First, a roll-forward style of recovery is implemented. A functioning process is never required to roll-back its state in order to achieve consistency with a recovering process. Second, the mechanism does not require any explicit information about the causal dependencies between updates. Instead, all necessary dependency information is inferred from the orders in which updates are logged by the object servers. This basic recovery technique appears to be applicable to forms of consistency other than causal consistency. In particular, it is shown how the recovery technique can be modified to support an atomic form of consistency (grouping consistency). By combining grouping consistency with casual consistency, it may even be possible to implement serializable consistency within this mechanism.

Kane, Kenneth Paul↗

Advanced Information Processing System (AIPS)-based fault tolerant avionics architecture for launch vehicles

An avionics architecture for the advanced launch system (ALS) that uses validated hardware and software building blocks developed under the advanced information processing system program is presented. The AIPS for ALS architecture defined is preliminary, and reliability requirements can be met by the AIPS hardware and software building blocks that are built using the state-of-the-art technology available in the 1992-93 time frame. The level of detail in the architecture definition reflects the level of detail available in the ALS requirements. As the avionics requirements are refined, the architecture can also be refined and defined in greater detail with the help of analysis and simulation tools. A useful methodology is demonstrated for investigating the impact of the avionics suite to the recurring cost of the ALS. It is shown that allowing the vehicle to launch with selected detected failures can potentially reduce the recurring launch costs. A comparative analysis shows that validated fault-tolerant avionics built out of Class B parts can result in lower life-cycle-cost in comparison to simplex avionics built out of Class S parts or other redundant architectures.

Lala, Jaynarayan H.↗

Adaptive Flight Control Research at NASA

A broad overview of current adaptive flight control research efforts at NASA is presented, as well as some more detailed discussion of selected specific approaches. The stated objective of the Integrated Resilient Aircraft Control Project, one of NASA s Aviation Safety programs, is to advance the state-of-the-art of adaptive controls as a design option to provide enhanced stability and maneuverability margins for safe landing in the presence of adverse conditions such as actuator or sensor failures. Under this project, a number of adaptive control approaches are being pursued, including neural networks and multiple models. Validation of all the adaptive control approaches will use not only traditional methods such as simulation, wind tunnel testing and manned flight tests, but will be augmented with recently developed capabilities in unmanned flight testing.

Motter, Mark A.↗

Solid Rocket Launch Vehicle Explosion Environments

Empirical explosion data from full scale solid rocket launch vehicle accidents and tests were collected from all available literature from the 1950s to the present. In general data included peak blast overpressure, blast impulse, fragment size, fragment speed, and fragment dispersion. Most propellants were 1.1 explosives but a few were 1.3. Oftentimes the data from a single accident was disjointed and/or missing key aspects. Despite this fact, once the data as a whole was digitized, categorized, and plotted clear trends appeared. Particular emphasis was placed on tests or accidents that would be applicable to scenarios from which a crew might need to escape. Therefore, such tests where a large quantity of high explosive was used to initiate the solid rocket explosion were differentiated. Also, high speed ground impacts or tests used to simulate such were also culled. It was found that the explosions from all accidents and applicable tests could be described using only the pressurized gas energy stored in the chamber at the time of failure. Additionally, fragmentation trends were produced. Only one accident mentioned the elusive "small" propellant fragments, but upon further analysis it was found that these were most likely produced as secondary fragments when larger primary fragments impacted the ground. Finally, a brief discussion of how this data is used in a new launch vehicle explosion model for improving crew/payload survival is presented.

Richardson, E. H.↗

Testing with the Laser-Enhanced Arc Jet Facility (LEAF) at NASA Ames Research Center

NASA's new Laser-Enhanced Arcjet Facility (LEAF) employs 200 kilowatts of continuous-wave fiber lasers, combined with a 60-megawatt arc plasma jet, to simulate the combined radiative and convective heating is now operational and Orion heat-shield material is undergoing testing. This upgrade to the existing Interaction Heating Facility (IHF) involves the addition of high-power fiber lasers that project 1070nm radiative energy into the existing vacuum chamber. The optically expanded laser beam enters a side window of the test chamber to form either a uniform 150 x 150 mm or a 425 x 425 mm square spot on a wedge-shaped model holder. Combined heating levels of up to 180 W/cm2 convective with either 300 W/cm2 or 100 W/cm2 are achievable. This allows the arc jet and lasers to simulate dynamic entry-heating profiles encountered during entry by the Orion crew capsule for the lunar return conditions. New computational investigations are underway to explore testing with the objective of defining ablative material failure limit. Typical arc-jet testing is performed with test article that are stagnation or wedge geometries. The existing convective heating test facility combined with test article design limits how high a combined shear, heat-flux and pressure conditions can be achieved. With the addition of laser power of 200 kW, much higher combined conditions of high heat-flux, pressure and shear is achievable on a wedge or a swept-cylinder article. Such testing possibilities will allow us to progressively increase the combined conditions and explore when an ablative TPS material may fail. The presentation provides an overview of the LEAF and present results from the on-going Orion Testing.

Venkatapathy, Ethiraj↗

Plant responses to rising vapor pressure deficit

Recent decades have been characterized by increasing temperatures worldwide, resulting in an exponential climb in vapor pressure deficit (VPD). VPD has been identified as an increasingly important driver of plant functioning in terrestrial biomes and has been established as a major contributor in recent drought‐induced plant mortality independent of other drivers associated with climate change. Despite this, few studies have isolated the physiological response of plant functioning to high VPD, thus limiting our understanding and ability to predict future impacts on terrestrial ecosystems. An abundance of evidence suggests that stomatal conductance declines under high VPD and transpiration increases in most species up until a given VPD threshold, leading to a cascade of subsequent impacts including reduced photosynthesis and growth, and higher risks of carbon starvation and hydraulic failure. Incorporation of photosynthetic and hydraulic traits in ‘next‐generation’ land‐surface models has the greatest potential for improved prediction of VPD responses at the plant‐ and global‐scale, and will yield more mechanistic simulations of plant responses to a changing climate. By providing a fully integrated framework and evaluation of the impacts of high VPD on plant function, improvements in forecasting and long‐term projections of climate impacts can be made.

mortality↗

Diurnal cycle of precipitation over the tropics and central United States: intercomparison of general circulation models

Diurnal precipitation is a fundamental mode of variability that climate models have difficulty in accurately simulating. Here, in this work, the diurnal cycle of precipitation (DCP) in participating climate models from the Global Energy and Water Exchanges' DCP project is evaluated over the tropics and central United States. Common model biases such as excessive precipitation over the tropics, too frequent light-to-moderate rain, and the failure to capture propagating convection in the central United States still exist. Over the central United States, the issues of too weak rainfall intensity in climate runs is well improved in their hindcast runs with initial conditions from numerical weather prediction analyses. But the improvement is minimal over the central Amazon. Incorporating the role of the large-scale environment in convective triggering processes helps resolve the phase-locking issue in many models where precipitation often incorrectly peaks near noon due to maximum insolation over land. Allowing air parcels to be lifted above the boundary layer improves the simulation of nocturnal precipitation which is often associated with the propagation of mesoscale systems. Including convective memory in cumulus parameterizations acts to suppress light-to-moderate rain and promote intense rainfall; however, it also weakens the diurnal variability. Simply increasing model resolution (with cumulus parameterizations still used) cannot fully resolve the biases of low-resolution climate models in DCP. The hierarchy modeling framework from this study is useful for identifying the missing physics in models and testing new development of model convective processes over different convective regimes.

58 GEOSCIENCES↗

A Vacuum Drying Study of Simulated Failed Nuclear Fuel (FY23)

This report documents work performed under the Office of Spent Fuel and Waste Disposition’s (SFWD’s) Spent Fuel and Waste Science and Technology program for the US Department of Energy (DOE) Office of Nuclear Energy (NE). This work was performed to fulfill Level 4 milestone M4SF-23OR010203013. Over the 70 years of light-water reactor (LWR) operation, fuel rod failures have occurred during reactor operation. Based on the Unified Database that SFWD maintains, there are ~5,400 LWR fuel rods that developed leaks during reactor operation of the >19 million rods operated. The Unified Database indicates that ~4,200 of these rods remain in the spent fuel pool, and ~1,200 are in dry storage canisters. It is expected that all failed rods are “waterlogged” in the spent fuel pool, meaning the inside of the rods contain some volume of water. There are two related objectives of this work. The first is to develop a simple and inexpensive experiment to better understand removal of water from inside failed spent nuclear fuel (SNF) rods, and the second is to develop a model to predict drying of simulated failed fuel in the simple experiment. Once a model captures the phenomenon in the simple experiment, it can be extended to predict drying under more prototypical conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gateway Integrated ECLSS Model Analysis of Intermodule Ventilation Failures

The Gateway Integrated ECLSS Model (GIEM) is a set of two independent models, made in Aspen Custom Modeler (ACM) and Thermal Desktop (TD), of the Gateway stack and each modules' associated environment control and life support system (ECLSS). The GIEM utilizes the 41-Node Metabolic Man (METMAN) to simulate crew inside the Gateway consuming O2 and producing CO2, H2O, and heat for the ECLSS to remove. The modules and visiting vehicles all have different levels of ECLSS capabilities and may rely on other modules and Intermodular Ventilation (IMV), which is used to exchange gas between the modules, to ensure the entire Gateway environment is controlled. If IMV were to fail or be turned off, some vehicles may have limited access to necessary ECLSS functions. This analysis focuses on evaluating O2, CO2, and H2O levels when crew are in vehicles without their own life support and IMV has failed to evaluate how long before the atmosphere is unsafe for the crew. This analysis uses the integrated nature of the GIEM to look at time to effect for O2 depletion and CO2 and H2O buildup when crew are working in vehicles that have been cut off from the ECLSS-active portion of the stack. This information is used to inform for how long crew can safely continue working in the ECLSS-inactive vehicles before experiencing a requirement violation or physical limitation and can be referenced when developing maintenance and emergency response concept of operations (ConOps).

Lawrence Barrett↗

Popcorning Failures in Polymer and MnO2 Tantalum Capacitors

Popcorning is a well-known effect in plastic encapsulated microcircuits (PEM) and it occurs in chip tantalum capacitors. The sensitivity of components to the presence of moisture during soldering is characterized by the moisture sensitivity level (MSL); however, contrary to PEMs, there is no standard procedure for establishing MSL for tantalum capacitors.The effect of absorbed moisture on soldering related degradation and failures in tantalum capacitors have not been studied properly yet, and there is no sufficient information regarding the difference in the sensitivity to soldering between polymer and MnO2 capacitors. In this work, 16 types of polymer and 9 types of MnO2 tantalum capacitors with different moisture content have been tested before and after reflow soldering. The level of moisture release during soldering has been estimated and thermo-mechanical analysis used to assess deformation of capacitorsduring soldering simulations. Results show that moisture uptake in similar parts is approximately two times greater in polymer than in MnO2 capacitors. Cracking of the case and degradation of parameters can occur in both types of parts, but MnO2 capacitors are much more likely to fail catastrophically with a short circuit and possible ignition during the first power-on cycle. This type of failure in MnO2 capacitors is lot-related, can occur even at derated voltages and relatively low levels of moisture sorption that corresponds to room conditions. Baking before soldering is an effective measure to prevent failures even in lots susceptible to popcorning damage.

Capacitor↗

Four-Stage Multi-Physics Simulations to Assist Temperature Sensor Design for Industrial-Scale Coal-Fired Boiler

The growth of renewable energy sources presents a pressing challenge to the operation and maintenance of existing fossil fuel power plants, given that fossil fuel remains the predominant fuel source, responsible for over 60% of electricity generation in the United States. One of the main concerns within these fossil fuel power plants is the unpredictable failure of boiler tubes, resulting in emergency maintenance with significant economic and societal consequences. A reliable high-temperature sensor is necessary for in situ monitoring of boiler tubes and the safety of fossil fuel power plants. In this study, a comprehensive four-stage multi-physics computational framework is developed to assist the design, optimization installation, and operation of the high-temperature stainless-steel and quartz coaxial cable sensor (SSQ-CCS) for coal-fired boiler applications. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. With the simulation-guided sensor installation plan, the newly designed SSQ-CCSs have been employed for field testing for more than 430 days. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

42 ENGINEERING↗

Simulated Solar Flare X-Ray and Thermal Cycling Durability Evaluation of Hubble Space Telescope Thermal Control Candidate Replacement Materials

During the Hubble Space Telescope (HST) second servicing mission (SM2), astronauts noticed that the multilayer insulation (MLI) covering the telescope was damaged. Large pieces of the outer layer of MLI (aluminized Teflon fluorinated ethylene propylene (Al-FEP)) were torn in several locations around the telescope. A piece of curled up Al-FEP was retrieved by the astronauts and was found to be severely embrittled, as witnessed by ground testing. Goddard Space Flight Center (GSFC) organized a HST MLI Failure Review Board (FRB) to determine the damage mechanism of FEP in the HST environment, and to recommend replacement insulation material to be installed on HST during the third servicing mission (SM3) in 1999. Candidate thermal control replacement materials were chosen by the FRB and tested for environmental durability under various exposures and durations. This paper describes durability testing of candidate materials which were exposed to charged particle radiation, simulated solar flare x-ray radiation and thermal cycling under load. Samples were evaluated for changes in solar absorptance and tear resistance. Descriptions of environmental exposures and durability evaluations of these materials are presented.

deGroh, Kim K.↗

TERRA Battery Thermal Control Anomaly - Simulation and Corrective Actions

The TERRA spacecraft was launched in December 1999 from Vandenberg Air Force Base, becoming the flagship of NASA's Earth Observing System program to gather data on how the planet's processes create climate. Originally planned as a 5 year mission, it still provides valuable science data after nearly 10 years on orbit. On October 13th, 2009 at 16:23z following a routine inclination maneuver, TERRA experienced a battery cell failure and a simultaneous failure of several battery heater control circuits used to maintain cell temperatures and gradients within the battery. With several cells nearing the minimum survival temperature, preventing the electrolyte from freezing was the first priority. After several reset attempts and power cycling of the control electronics failed to reestablish control authority on the primary side of the controller, it was switched to the redundant side, but anomalous performance again prevented full heater control of the battery cells. As the investigation into the cause of the anomaly and corrective action continued, a battery thermal model was developed to be used in determining the control ability remaining and to simulate and assess corrective actions. Although no thermal model or detailed reference data of the battery was available, sufficient information was found to allow a simplified model to be constructed, correlated against pre-anomaly telemetry, and used to simulate the thermal behavior at several points after the anomaly. It was then used to simulate subsequent corrective actions to assess their impact on cell temperatures. This paper describes the rapid development of this thermal model, including correlation to flight data before and after the anomaly., along with a comparative assessment of the analysis results used to interpret the telemetry to determine the extent of damage to the thermal control hardware, with near-term corrective actions and long-term operations plan to overcome the anomaly.

Grob, Eric W.↗

Characterizing Impacts of Storage Faults on HPC Applications: A methodology and insights

In recent years, the increasing complexity in scientific simulations and emerging demands for training heavy artificial intelligence models require massive and fast data accesses, which urges high-performance computing (HPC) platforms to equip with more advanced storage infrastructures such as solid-state disks (SSDs). While SSDs offer high-performance I/O, it remains unclear about the reliability challenges faced by the HPC applications under the SSD-related failures, in particular, failures resulting in data corruptions. The goal of this paper is to understand the impact of SSD-related data corruptions on the behaviors of complex HPC applications. To this end, we propose FFIS, a FUSE-based fault injection framework that systematically introduces storage faults into the application layer to model the errors originated from SSDs. FFIS is able to plant different I/O related faults into the data returned from underlying file systems, which also enables the investigation on the error resilience characteristics of the scientific file format for the first time. We demonstrate the use of FFIS with three representative real HPC applications, show how each application reacts to the data corruptions, and provide insights on the error resilience of the widely-adopted HDF5 file format for the HPC applications.

Fang, Bo↗