SU-F-J-89: Assessment of Delivered Dose in Understanding HCC Tumor Progression Following SBRT

Purpose: It is well documented that the delivered dose to patients undergoing radiotherapy (RT) is often different from the planned dose due to geometric variability and uncertainties in patient positioning. Recent work suggests that accumulated dose to the GTV is a better predictor of progression compared to the minimum planned dose to the PTV. The purpose of this study is to evaluate if deviations from the planned dose can contributed to tumor progression. Methods: From 2010 to 2014 an in-house Phase II clinical trial of adaptive stereotactic body RT was completed. Of the 90 patients enrolled, 7 patients had a local recurrence defined on contrast enhanced CT or MR imaging 3–21 months after completion of RT. Retrospective dose accumulation was performed using a biomechanical model-based deformable image registration algorithm (DIR) to accumulate the dose based on the kV CBCT acquired prior to each fraction for soft tissue alignment of the patient. The DIR algorithm was previously validated for geometric accuracy in the liver (target registration error = 2.0 mm) and dose accumulation in a homogeneous image, similar to a liver CBCT (gamma index = 91%). Following dose accumulation, the minimum dose to 0.5 cc of the GTV was compared between the planned and accumulated dose. Work is ongoing to evaluate the tumor control probability based on the planned and accumulated dose. Results: DIR and dose accumulation was performed on all fractions for 6 patients with local recurrence. The difference in minimum dose to 0.5 cc of the GTV ranged from −0.3–2.3 Gy over 3–5 fractions. One patient had a potentially significant difference in minimum dose of 2.3 Gy. Conclusion: Dose accumulation can reveal tumor underdosage, improving our ability to understand recurrence and tumor progression patterns, and could aid in adaptive re-planning during therapy to correct for this. This work was supported in part by NIH P01CA059827.

60 APPLIED LIFE SCIENCES↗

WOBBLE: A Proposed Mission to Characterize Past and Present Water on Mars

WOBBLE ("Water Observations from a Balloon Borne Light Explorer") is a mission concept study for a small robotic probe to explore Mars and to accomplish a scientific mission compatible with the goals of the NASA Code S enterprise. The detection of past or present water is a crucial goal for Mars exploration, representing a cross-cutting science theme relevant to past or extant life, climate history, sample return missions and eventual human exploration. The WOBBLE mission concept was developed to study evidence of water using in-situ detection methods. The features on Mars most suited to this investigation are the gullies identified by Malin and Edgett as evidence for recent, near-surface runoff of liquid water. These features are typically located on the inside face of crater rims, where the local slope angle is at or near the angle of repose. This makes the terrain difficult or impossible to access with conventional wheeled rover technology. Combined with the small size of the gullies in relation to a standard landing error ellipse, scientific investigation of these features requires a new approach to surface mobility. WOBBLE uses a low-altitude balloon-borne platform to traverse the surface from the landing site, to the investigation site, and then rise up the slope to investigate the regions of interest at close range. Of the mobility technologies available for near-term Mars exploration, only a balloon platform is capable of a well targeted, detailed sampling of the gully regions over periods of days or more. The science approach embodied in WOBBLE is two-pronged, designed to investigate both the historical evidence of liquid water utilizing high-resolution geomorphology and the characterization of mineral deposits, and present subsurface liquid water using radar sounding techniques. The WOBBLE balloon is a high-pressure hydrogen gas design, 24 meters in diameter and lifting a total payload of 130 kg, including a high-resolution camera/IR imager, Raman spectrometer, and a ground penetrating radar (GPR) sounder. The stowed balloon and payload are designed to fit within the current airbag delivery system being built for the Mars Exploration Rovers. Characterization of local meteorological conditions and wind is made over the initial sols following landing and before balloon inflation. Following balloon inflation and launch, a controlled, targeted approach toward the identified regions of interest is made in a series of several low-altitude "hops," with the balloon tethered to the ground between the hop intervals. A "snake" system is used to control the altitude to a few tens of meters above the local ground level. Enroute to the target gully, GPR soundings and Raman spectroscopy measurements study past or present water, while continued camera bearings and meteorological measurements refine the next "hop" trajectory. Once at the gully/outflow region, GPR and Raman soundings continue while the camera obtains detailed, approx. 0.5 cm images for geomorphology studies. The WOBBLE concept is applicable to Mars Scout, Mars Surveyor, or Discovery class missions.

Udrea, Bogdan↗

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Between Infrared Optical and Stereoscopic X-Ray Technologies for Patient Setup in Image Guided Stereotactic Radiotherapy

Purpose: To compare infrared (IR) optical vs. stereoscopic X-ray technologies for patient setup in image-guided stereotactic radiotherapy. Methods and Materials: Retrospective data analysis of 233 fractions in 127 patients treated with hypofractionated stereotactic radiotherapy was performed. Patient setup at the linear accelerator was carried out by means of combined IR optical localization and stereoscopic X-ray image fusion in 6 degrees of freedom (6D). Data were analyzed to evaluate the geometric and dosimetric discrepancy between the two patient setup strategies. Results: Differences between IR optical localization and 6D X-ray image fusion parameters were on average within the expected localization accuracy, as limited by CT image resolution (3 mm). A disagreement between the two systems below 1 mm in all directions was measured in patients treated for cranial tumors. In extracranial sites, larger discrepancies and higher variability were observed as a function of the initial patient alignment. The compensation of IR-detected rotational errors resulted in a significantly improved agreement with 6D X-ray image fusion. On the basis of the bony anatomy registrations, the measured differences were found not to be sensitive to patient breathing. The related dosimetric analysis showed that IR-based patient setup caused limited variations in three cases, with 7% maximum dose reduction in the clinical target volume and no dose increase in organs at risk. Conclusions: In conclusion, patient setup driven by IR external surrogates localization in 6D featured comparable accuracy with respect to procedures based on stereoscopic X-ray imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A crystal plasticity model with an atomistically informed description of grain boundary sliding for improved predictions of deformation fields

Crystal plasticity (CP) is a powerful meso-scale technique for deformation modeling in polycrystalline materials. Crystal plasticity models typically do not include an explicit description of grain boundary (GB) sliding, which could lead to inaccurate predictions of strain distributions, especially in the vicinity of GBs. In the present study, a CP model is developed that includes GB sliding as an additional deformation mechanism and models the interaction between slip and GB sliding. Atomistic simulations are used to formulate the constitutive model for GB sliding and its interaction with incident slip. The deformation fields and structure of the GBs are obtained directly from experimental characterization and are faithfully reproduced as bicrystal systems for molecular dynamics simulations. The GBs are modeled as random-type (non-coincidence, asymmetrical) boundaries as observed from experimental data. The underlying atomistic-scale mechanism for pure sliding of random GBs was found to be analogous to fluid-flow. The interaction between incident slip and a sliding GB caused local increases in stress concentration, which further led to a momentary increase in the local sliding rate. The displacement profiles at the sliding GBs computed from the CP model with sliding accommodation are 38% more accurate than the baseline CP model as quantified by the mean squared error between the simulations and experiment. Here these results help improve the sophistication and accuracy of deformation modeling by including physics-based descriptions for GB sliding and its interaction with slip, eventually leading to more reliable predictions of micromechanical quantities.

36 MATERIALS SCIENCE↗

A method to correct coordinate distortion in EBSD maps

Drift during electron backscatter diffraction mapping leads to coordinate distortions in resulting orientation maps, which affects, in some cases significantly, the accuracy of analysis. A method, thin plate spline, is introduced and tested to correct such coordinate distortions in the maps after the electron backscatter diffraction measurements. The accuracy of the correction as well as theoretical and practical aspects of using the thin plate spline method is discussed in detail. By comparing with other correction methods, it is shown that the thin plate spline method is most efficient to correct different local distortions in the electron backscatter diffraction maps. - Highlights: • A new method is suggested to correct nonlinear spatial distortion in EBSD maps. • The method corrects EBSD maps more precisely than presently available methods. • Errors less than 1–2 pixels are typically obtained. • Direct quantitative analysis of dynamic data are available after this correction.

36 MATERIALS SCIENCE↗

Practical solutions for reliable triple probe measurements in magnetized plasmas

The triple probe method to obtain local, time-resolved measurements of density, electron temperature and plasma potential is investigated in detail. The difficulties in obtaining reliable measurements with this technique are discussed and overcome. These include phase delay errors, ion sheath expansion and limited bandwidth due to stray capacitance to ground. In particular, a relatively simple electronic circuit is described to strongly reduce stray capacitance. Measurements with the triple probe are presented in a plasma characterized by interchange-driven turbulence in the TORPEX device. The measured time-averaged and time-dependent, conditionally averaged parameters are cross-checked with other Langmuir probe based techniques, and show good agreement. Triple probe measurements show that electron temperature fluctuations are sufficiently large, such that the identification of plasma potential fluctuations with fluctuations of the floating potential is not a good approximation. Over a large radial region, the time-averaged fluctuation-induced particle flux can, however, be deduced from floating potential only. This is because the phase shift between density and electron temperature is close to zero there and temperature fluctuations do not give rise to a net radial particle transport.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fidelity CFD Simulation of Mixed Convection and Forced Convection in a Pebble Bed Test Reactor Core

The Hermes low-power [35-MW(thermal)] reactor will be built and operated by Kairos Power LLC (KP) to demonstrate its fluoride salt-cooled high-temperature reactor (FHR) technology. In the KP FHR, the reactor core is composed of randomly packed pebbles with TRISO fuel particles inside with FLiBe flow upward through the core acting as a coolant. Previous numerical and experimental studies have been limited to either a small-size bed or to a lack of detailed measurements for heat transfer. Here, to address the lack of high-fidelity heat transfer data in a real-size FHR core, in this study, we simulated a pebble bed core with 34 374 pebbles randomly packed, similar to the Hermes reactor's size. The core radius was 14 times that of the pebble diameter, while the core height was 45 times. In this work, we were particularly interested in a mixed convection regime, where buoyancy is important. Therefore, we performed several large-eddy simulations at different Reynolds numbers (160 to 1000) with gravitational force included. The spectral element computational fluid dynamics code NekRS with graphics processing unit acceleration was used for this study. The low-Mach number approximation was applied to address property changes in the FLiBe and to account for buoyancy. A pure hexahedral mesh with 60 million elements was generated by the Voronoi cell method. At the polynomial order of 5, the total degrees of freedom was 7.5 billion. The developed case in this work is the first of its kind in terms of size and complexity. The local numerical data across the domain were obtained and compared with empirical correlations. After examining the data, we found the following conclusions. For pressure drop, the Reger correlation predicted less than a 5% error. On the other hand, for heat transfer, the Wakao correlation outperformed the others. Based on our findings, we recommend the use of the Wakao correlation for the Nusselt number calculation, and for pressure drop, the KTA (Kerntechnischer Ausschuss) correclation, among the available experimental correlations. In conclusion, the Reger direct numerical simulation-driven correlation for pressure drops should also be considered, given its best agreement with our calculations.

Mixed Convection↗

DEEP NEAR-INFRARED SPECTROSCOPY OF PASSIVELY EVOLVING GALAXIES AT z {approx}> 1.4

We present the results of new near-IR spectroscopic observations of passive galaxies at z {approx}> 1.4 in a concentration of BzK-selected galaxies in the COSMOS field. The observations have been conducted with Subaru/MOIRCS, and have resulted in absorption lines and/or continuum detection for 18 out of 34 objects. This allows us to measure spectroscopic redshifts for a sample that is almost complete to K{sub AB} = 21. COSMOS photometric redshifts are found in fair agreement overall with the spectroscopic redshifts, with a standard deviation of {approx}0.05; however, {approx}30% of objects have photometric redshifts systematically underestimated by up to {approx}25%. We show that these systematic offsets in photometric redshifts can be removed by using these objects as a training set. All galaxies fall in four distinct redshift spikes at z = 1.43, 1.53, 1.67, and 1.82, with this latter one including seven galaxies. SED fits to broadband fluxes indicate stellar masses in the range of {approx}4-40 Multiplication-Sign 10{sup 10} M{sub Sun} and that star formation was quenched {approx}1 Gyr before the cosmic epoch at which they are observed. The spectra of several individual galaxies have allowed us to measure their H{delta}{sub F} indices and the strengths of the 4000 A break, which confirms their identification as passive galaxies, as does a composite spectrum resulting from the co-addition of 17 individual spectra. The effective radii of the galaxies have been measured on the COSMOS HST/ACS i{sub F814W}-band image, confirming the coexistence at these redshifts of passive galaxies, which are substantially more compact than their local counterparts with others that follow the local effective radius-stellar mass relation. For the galaxy with the best signal-to-noise spectrum we were able to measure a velocity dispersion of 270 {+-} 105 km s{sup -1} (error bar including systematic errors), indicating that this galaxy lies closely on the virial relation given its stellar mass and effective radius.

79 ASTRONOMY AND ASTROPHYSICS↗

REEVALUATING THE MASS-RADIUS RELATION FOR LOW-MASS, MAIN-SEQUENCE STARS

We examine the agreement between the observed and theoretical low-mass (<0.8 M{sub Sun }) stellar main-sequence mass-radius relationship by comparing detached eclipsing binary (DEB) data with a new, large grid of stellar evolution models. The new grid allows for a realistic variation in the age and metallicity of the DEB population, characteristic of the local galactic neighborhood. Overall, our models do a reasonable job of reproducing the observational data. A large majority of the models match the observed stellar radii to within 4%, with a mean absolute error of 2.3%. These results represent a factor of two improvement compared to previous examinations of the low-mass mass-radius relationship. The improved agreement between models and observations brings the radius deviations within the limits imposed by potential starspot-related uncertainties for 92% of the stars in our DEB sample.

79 ASTRONOMY AND ASTROPHYSICS↗

ORBIT simulations of fast ion power loads on the wall of the Divertor Tokamak Test

Abstract Neutral beam injection in tokamaks produces a population of fast ions, which interact with 3D magnetic fields in a variety of ways, often resulting in energetic particle losses in very short times to the wall. Careful design of neutral beams and active control of error fields helps to keep these losses to a minimum. Nevertheless, past experience in tokamaks in the 1980s and detailed simulations for future machines, such as International Thermonuclear Experimental Reactor, suggest that very localized fast ion losses (‘hot spots’) can be present, even if the overall losses are low. In this paper, we discuss this issue in the Divertor Tokamak Test (DTT) project, and we show that in the standard single-null full-power scenario of the DTT, fast ions produce two hot spots, corresponding approximately to the beam injection and exit toroidal angles: the former being mainly due to prompt losses/passing particles, while the latter is due to trapped ions. However, the maximum power load in these spots is of the order ∼ 63 kW m −2 , below the tolerance of plasma-facing components of the machine.

Physics↗

Extreme Scale Infrasound Inversion and Prediction for Weather Characterization and Acute Event Detection

Accurate and timely weather predictions are critical to many aspects of society with a profound impact on our economy, general well-being, and national security. In particular, our ability to forecast severe weather systems is necessary to avoid injuries and fatalities, but also important to minimize infrastructure damage and maximize mitigation strategies. The weather community has developed a range of sophisticated numerical models that are executed at various spatial and temporal scales in an attempt to issue global, regional, and local forecasts in pseudo real time. The accuracy however depends on the time period of the forecast, the nonlinearities of the dynamics, and the target spatial resolution. Significant uncertainties plague these predictions including errors in initial conditions, material properties, data, and model approximations. To address these shortcomings, a continuous data collection occurs at an effort level that is even larger than the modeling process. It has been demonstrated that the accuracy of the predictions depends on the quality of the data and is independent to a certain extent on the sophistication of the numerical models. Data assimilation has become one of the more critical steps in the overall weather prediction business and consequently substantial improvements in the quality of the data would have transformational benefits. This paper describes the use of infrasound inversion technology, enabled through exascale computing, that could potentially achieve orders of magnitude improvement in data quality and therefore transform weather predictions with significant impact on many aspects of our society.

58 GEOSCIENCES↗

ASCEND: Asymptotically compatible strong form foundations for nonlocal discretization

Nonlocal models naturally handle a range of physics of interest to SNL, but discretization of their underlying integral operators poses mathematical challenges to realize the accuracy and robustness commonplace in discretization of local counterparts. This project focuses on the concept of asymptotic compatibility, namely preservation of the limit of the discrete nonlocal model to a corresponding well-understood local solution. We address challenges that have traditionally troubled nonlocal mechanics models primarily related to consistency guarantees and boundary conditions. For simple problems such as diffusion and linear elasticity we have developed complete error analysis theory providing consistency guarantees. We then take these foundational tools to develop new state-of-the-art capabilities for: lithiation-induced failure in batteries, ductile failure of problems driven by contact, blast-on-structure induced failure, brittle/ductile failure of thin structures. We also summarize ongoing efforts using these frameworks in data-driven modeling contexts. This report provides a high-level summary of all publications which followed from these efforts.

97 MATHEMATICS AND COMPUTING↗

Efficiently improving the performance of noisy quantum computers

Using near-term quantum computers to achieve a quantum advantage requires efficient strategies to improve the performance of the noisy quantum devices presently available. We develop and experimentally validate two efficient error mitigation protocols named "Noiseless Output Extrapolation" and "Pauli Error Cancellation" that can drastically enhance the performance of quantum circuits composed of noisy cycles of gates. By combining popular mitigation strategies such as probabilistic error cancellation and noise amplification with efficient noise reconstruction methods, our protocols can mitigate a wide range of noise processes that do not satisfy the assumptions underlying existing mitigation protocols, including non-local and gate-dependent processes. We test our protocols on a four-qubit superconducting processor at the Advanced Quantum Testbed. We observe significant improvements in the performance of both structured and random circuits, with up to 86 &#x0025; improvement in variation distance over the unmitigated outputs. Our experiments demonstrate the effectiveness of our protocols, as well as their practicality for current hardware platforms.

97 MATHEMATICS AND COMPUTING↗

An Incompressible, Depth-Averaged Lattice Boltzmann Method for Liquid Flow in Microfluidic Devices with Variable Aperture

Two-dimensional (2D) pore-scale models have successfully simulated microfluidic experiments of aqueous-phase flow with mixing-controlled reactions in devices with small aperture. A standard 2D model is not generally appropriate when the presence of mineral precipitate or biomass creates complex and irregular three-dimensional (3D) pore geometries. We modify the 2D lattice Boltzmann method (LBM) to incorporate viscous drag from the top and bottom microfluidic device (micromodel) surfaces, typically excluded in a 2D model. Viscous drag from these surfaces can be approximated by uniformly scaling a steady-state 2D velocity field at low Reynolds number. We demonstrate increased accuracy by approximating the viscous drag with an analytically-derived body force which assumes a local parabolic velocity profile across the micromodel depth. Accuracy of the generated 2D velocity field and simulation permeability have not been evaluated in geometries with variable aperture. We obtain permeabilities within approximately 10% error and accurate streamlines from the proposed 2D method relative to results obtained from 3D simulations. Additionally, the proposed method requires a CPU run time approximately 40 times less than a standard 3D method, representing a significant computational benefit for permeability calculations.

58 GEOSCIENCES↗

Estimations of the Global Distribution and Time Series of UV Noontime Irradiance (305, 310, 324, 380 nm, and Erythemal) from TOMS and SeaWiFS Data

The amount of UV irradiance reaching the Earth's surface is estimated from the measured cloud reflectivity, ozone, aerosol amounts, and surface reflectivity time series from 1980 to 1992 and 1997 to 2000 to estimate changes that have occurred over a 21-year period. Recent analysis of the TOMS data shows that there has been an apparent increase in reflectivity (decrease in W) in the Southern Hemisphere that is related to a calibration error in EP-TOMS. Data from the well-calibrated SeaWiFS satellite instrument have been used to correct the EP-TOMS reflectivity and UV time series. After correction, some of the local trend features seen in the N7 time series (1980 to 1992) have been continued in the combined time series, but the overall zonal average and global trends have changed. In addition to correcting the EP-TOMS radiance calibration, the use of SeaWiFS cloud data permits estimation of UV irradiance at higher spatial resolution (1 to 4 km) than is available from TOMS (100 km) under the assumption that ozone is slowly varying over a scale of 100 km. The key results include a continuing decrease in cloud cover over Europe and North America with a corresponding increase in UV and a decrease in UV irradiance near Antarctica.

Herman, J.↗

Digital Receiver Phase Meter

The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density <5 microcycle/(Hz)1/2 and to be capable of determining the power spectral density of the phase difference over the frequency range from 1 mHz to 1 Hz. Such a phase meter could also be used on Earth to perform similar measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

Marcin, Martin↗

Considerations for Using Hybrid Ensemble-Variational Data Assimilation in NASA-GMAO's Next Reanalysis System

The Modern-Era Retrospective Analysis for Research and Applications, version 2 (MERRA-2) is the latest reanalysis produced by GMAO, and provides global data spanning the period 1980-present. The atmospheric data assimilation component of MERRA-2 used a 3D-Var scheme, which was operational at the time of its design. Since then, a Hybrid 3D-Var, then a Hybrid 4D-EnVar were implemented, adding an ensemble component to the data assimilation scheme. In this work, we will be examining the benefits of using hybrid ensemble flow-dependent covariances to represent errors and uncertainties in historic periods. Specifically, periods of pre- and post-satellites, as well as periods of active tropical cyclone seasons. Finally, we will also be exploring the use of adaptive localization scales.