Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Effect of parallactic refraction correction on station height determination

The effect of omitting the parallactic refraction correction for satellite optical observations in the determination of station coordinates is analyzed for a large satellite data distribution. A significant error effect is seen in station heights. A geodetic satellite data distribution of 23 close earth satellites, containing 30,000 optical observations obtained by 13 principal Baker-Nunn camera sites, is employed. This distribution was used in a preliminary Goddard Earth Model (GEM 1) for the determination of the gravity field of the earth and geocentric tracking station locations. The parallactic refraction correction is modeled as an error on the above satellite data and a least squares adjustment for station locations is obtained for each of the 13 Baker-Nunn sites. Results show an average station height shift of +8 meters with a dispersion of plus or minus 0.7 meters for individual sites. Station latitude and longitude shifts amounted to less than a meter. Similar results are obtained from a theoretical method employing a probability distribution for the satellite optical observations.

Lerch, F. J.↗

Efficient grid generation

Because the governing equations in fluid dynamics contain partial differentials and are too difficult in most cases to solve analytically, these differentials are generally replaced by finite difference terms. These terms contain terms in the solution at nearby states. This procedure discretizes the field into a finite number of states. These states, when plotted, form a grid, or mesh, of points. It is at these states, or field points, that the solution is found. The optimum choice of states, the x, y, z coordinate values, minimizes error and computational time. But the process of finding these states is made more difficult by complex boundaries, and by the need to control step size differences between the states, that is, the need to control the spacing of field points. One solution technique uses a different set of state variables, which define a different coordinate system, to generate the grid more easily. A new method, developed by Dr. Joseph Steger, combines elliptic and hyperbolic partial differential equations into a mapping function between the physical and computational coordinate systems. This system of equations offers more control than either equation provides alone. The Steger algorithm was modified in order to allow bodies with stronger concavities to be used, offering the possibility of generating a single grid about multiple bodies. Work was also done on identifying areas where grid breakdown occurs.

Seki, Rycichi↗

Tensor networks, p -adic fields, and algebraic curves: arithmetic and the AdS 3 /CFT 2 correspondence

One of the many remarkable properties of conformal field theory in two dimensions is its connection to algebraic geometry. Since every compact Riemann surface is a projective algebraic curve, many constructions of interest in physics (which a priori depend on the analytic structure of the spacetime) can be formulated in purely algebraic language. This opens the door to interesting generalizations, obtained by taking another choice of field: for instance, the p-adics. Herein, we generalize the $\mathrm{AdS} / \mathrm{CFT}$ correspondence according to this principle; the result is a formulation of holography in which the bulk geometry is discrete—the Bruhat–Tits tree for $\mathrm{PGL} (2, \mathbb{Q}_p)$—but the group of bulk isometries nonetheless agrees with that of boundary conformal transformations and is not broken by discretization. We anticipate that this forms the natural geometric setting for tensor networks that have been proposed as models of bulk reconstruction via quantum error correcting codes; in certain cases, geodesics in the Bruhat–Tits tree reproduce those constructed using quantum error correction. Other aspects of holography also hold: Standard holographic results for massive free scalar fields in a fixed background carry over to the tree, whose vertical direction can be interpreted as a renormalization-group scale for modes in the boundary $\mathrm{CFT}$. Higher-genus bulk geometries (the $\mathrm{BTZ}$ black hole and its generalizations) can be understood straightforwardly in our setting, and the Ryu–Takayanagi formula for the entanglement entropy appears naturally

97 MATHEMATICS AND COMPUTING↗

SU-E-T-584: Optical Tracking Guided Patient-Specific VMAT QA with ArcCHECK

Purpose: To investigate the novel use of an in-house optical tracking system (OTS) to improve the efficacy of VMAT QA with a cylindrical dosimeter (ArcCHECK™). Methods: The translational and rotational setup errors of ArcCHECK are convoluted which makes it challenging to position the device efficiently and accurately. We first aligned the ArcCHECK to the machine cross-hair at three cardinal angles (0°, 90°, and 270°) to establish a reference position. Four infrared reflective markers were attached to the back of the device. An OTS with 0.2mm/0.2° accuracy was used to control its setup uncertainty. Translational uncertainties of 1 mm and 2 mm in three directions (in, right, and up) were applied on the device. Four open beams of various field sizes and six clinical VMAT arcs were delivered and measured for all simulated setup errors. The measurements were compared with Pinnacle™ calculations using Gamma analysis to evaluate the impact of setup uncertainty. This study also evaluated the improvement in setup reproducibility and efficiency with the aid of the OTS. Results: For open beams, with 3%/3mm, the mean passing rates dropped by less than 5% for all shifts; with 2%/2mm, two significant drops(>5%) were observed: 15.38±6.75% for 2 mm lateral shift and 9.35±4.88% for 2 mm longitudinal shift. For VMAT arcs, the mean passing rates using 2%/2mm dropped by 10.47±7.46% and 22.02±11.39% for 1 and 2 mm shift, respectively. With 3%/3mm, significant drop only occurred with 2 mm longitudinal shift (13.73±8.30%). Setup time could be reduced by >15 min with the aid of the OTS. Conclusion: OTS is an effective tool for separating translational and rotational uncertainties. The current VMAT QA solution was not strongly sensitive to translation errors of 2mm with widely accepted criterion (3%/3mm). This finding raises concerns regarding the efficacy of such QA system in detecting errors in the dynamic VMAT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

An analytical method to calculate equivalent fields to irregular symmetric and asymmetric photon fields

Equivalent field is frequently used for central axis depth-dose calculations of rectangular- and irregular-shaped photon beams. As most of the proposed models to calculate the equivalent square field are dosimetry based, a simple physical-based method to calculate the equivalent square field size was used as the basis of this study. The table of the sides of the equivalent square or rectangular fields was constructed and then compared with the well-known tables by BJR and Venselaar, et al. with the average relative error percentage of 2.5 ± 2.5% and 1.5 ± 1.5%, respectively. To evaluate the accuracy of this method, the percentage depth doses (PDDs) were measured for some special irregular symmetric and asymmetric treatment fields and their equivalent squares for Siemens Primus Plus linear accelerator for both energies, 6 and 18 MV. The mean relative differences of PDDs measurement for these fields and their equivalent square was approximately 1% or less. As a result, this method can be employed to calculate equivalent field not only for rectangular fields but also for any irregular symmetric or asymmetric field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of directional radiation models on the interpretation of earth radiation budget measurements

A parameter estimation technique is presented to estimate the radiative flux density distribution over the earth from a set of radiometer measurements at satellite altitude. The technique analyzes measurements from a wide field of view, horizon to horizon, nadir pointing sensor with a mathematical technique to derive the radiative flux density estimates at the top of the atmosphere for resolution elements smaller than the sensor field of view. A computer simulation of the data analysis technique is presented for both earth-emitted and reflected radiation. The errors resulting from the assumed directional radiation model, spatial model and random measurement error have little effect on the global mean radiation. Zonal estimates were found to be more sensitive to the spatial model than to the directional radiation model. Results from analyzing medium field of view measurements showed a much greater sensitivity to the directional radiation model even on a global scale.

Green, R. N.↗

SU-E-T-299: Small Fields Profiles Correction Through Detectors Spatial Response Functions and Field Size Dependence Analysis

Purpose: To calculate the spatial response function of various radiation detectors, to evaluate the dependence on the field size and to analyze the small fields profiles corrections by deconvolution techniques. Methods: Crossline profiles were measured on a Novalis Tx 6MV beam with a HDMLC. The configuration setup was SSD=100cm and depth=5cm. Five fields were studied (200×200mm2,100×100mm2, 20×20mm2, 10×10mm2and 5×5mm2) and measured were made with passive detectors (EBT3 radiochromic films and TLD700 thermoluminescent detectors), ionization chambers (PTW30013, PTW31003, CC04 and PTW31016) and diodes (PTW60012 and IBA SFD). The results of passive detectors were adopted as the actual beam profile. To calculate the detectors kernels, modeled by Gaussian functions, an iterative process based on a least squares criterion was used. The deconvolutions of the measured profiles were calculated with the Richardson-Lucy method. Results: The profiles of the passive detectors corresponded with a difference in the penumbra less than 0.1mm. Both diodes resolve the profiles with an overestimation of the penumbra smaller than 0.2mm. For the other detectors, response functions were calculated and resulted in Gaussian functions with a standard deviation approximate to the radius of the detector in study (with a variation less than 3%). The corrected profiles resolve the penumbra with less than 1% error. Major discrepancies were observed for cases in extreme conditions (PTW31003 and 5×5mm2 field size). Conclusion: This work concludes that the response function of a radiation detector is independent on the field size, even for small radiation beams. The profiles correction, using deconvolution techniques and response functions of standard deviation equal to the radius of the detector, gives penumbra values with less than 1% difference to the real profile. The implementation of this technique allows estimating the real profile, freeing from the effects of the detector used for the acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the Effect of Lidar Turbulence Error on Wind Power Prediction

Currently, cup anemometers on meteorological towers are used to measure wind speeds and turbulence intensity to make decisions about wind turbine class and site suitability; however, as modern turbine hub heights increase and wind energy expands to complex and remote sites, it becomes more difficult and costly to install meteorological towers at potential sites. As a result, remote-sensing devices (e.g., lidars) are now commonly used by wind farm managers and researchers to estimate the flow field at heights spanned by a turbine. Although lidars can accurately estimate mean wind speeds and wind directions, there is still a large amount of uncertainty surrounding the measurement of turbulence using these devices. Errors in lidar turbulence estimates are caused by a variety of factors, including instrument noise, volume averaging, and variance contamination, in which the magnitude of these factors is highly dependent on measurement height and atmospheric stability. As turbulence has a large impact on wind power production, errors in turbulence measurements will translate into errors in wind power prediction. The impact of using lidars rather than cup anemometers for wind power prediction must be understood if lidars are to be considered a viable alternative to cup anemometers.In this poster, the sensitivity of power prediction error to typical lidar turbulence measurement errors is assessed. Turbulence estimates from a vertically profiling WINDCUBE v2 lidar are compared to high-resolution sonic anemometer measurements at field sites in Oklahoma and Colorado to determine the degree of lidar turbulence error that can be expected under different atmospheric conditions. These errors are then incorporated into a power prediction model to estimate the sensitivity of power prediction error to turbulence measurement error. Power prediction models, including the standard binning method and a random forest method, were developed using data from the aeroelastic simulator FAST for a 1.5 MW turbine. The impact of lidar turbulence error on the predicted power from these different models is examined to determine the degree of turbulence measurement accuracy needed for accurate power prediction.

17 WIND ENERGY↗

Errors in magnetic direction finding due to nonvertical lightning channels

A theory showing that errors in lightning magnetic direction finding due to nonvertical source orientations are minimized by detecting the field from the lowest possible channel section is presented. For 99 cloud-to-ground lightning channels photographed in Arizona, 45 exhibited a bottom few hundred meters within about 8 deg of the vertical, the standard deviation of the distribution of lower-channel tilt angles being about 18 deg. These experimental results, coupled with theory, suggest that if a wideband gated direction finder is used, polarization errors due to nonvertical sources can be kept less than 1 deg for lightning beyond 10 km.

Uman, M. A.↗

Code verification for practically singular equations

We report the method-of-moments implementation of the electric-field integral equation (EFIE) yields many code-verification challenges due to the various sources of numerical error and their possible interactions. Matters are further complicated by singular integrals, which arise from the presence of a Green's function. To address these singular integrals, an approach is presented in wherein both the solution and Green's function are manufactured. Because the arising equations are poorly conditioned, they are reformulated as a set of constraints for an optimization problem that selects the solution closest to the manufactured solution. In this paper, we demonstrate how, for such practically singular systems of equations, computing the truncation error by inserting the exact solution into the discretized equations cannot detect certain orders of coding errors. On the other hand, the discretization error from the optimal solution is a more sensitive metric that can detect orders less than those of the expected convergence rate.

97 MATHEMATICS AND COMPUTING↗

STEREO SECCHI COR1-A/B Intercalibration at 180 deg Separation

The twin Solar Terrestrial Relations Observatory (STEREO) spacecraft reached a separation angle of 180 degrees on 6 February 2011. This provided a unique opportunity to test the intercalibration between the Sun-Earth Connection Coronal and Heliospheric Investigation (SECCHI) telescopes on both spacecraft for areas above the limb. So long as the corona is optically thin, at 180 degree separation each spacecraft sees the same corona from opposite directions. Thus, the data should appear as mirror images of each other. We report here on the results of the comparison of the images taken by the inner coronagraph (COR1) on the STEREO Ahead and Behind spacecraft in the hours when the separation was close to 180 degrees. We find that the intensity values seen by the two telescopes agree with each other to a high degree of accuracy. This validates both the radiometric intercalibration between the COR1 telescopes, and the method used to remove instrumental background from the images. The relative error between COR1-A and COR1-B is found to be less than 10(exp -9) B/B solar over most of the field-of-view, growing to a few x 10(exp -9) B/B solar for the brighter pixels near the edge of the occulter. The primary source of error is the background determination. We also report on the analysis of star observations which show that the absolute radiometric calibration of either COR1 telescope has not changed significantly since launch.

Thompson, W. T.↗

DPSK based low cost radio over fiber system for communication

The field of radio communication always demands high data rate, large bandwidth, low Bit Error Rate and flexible adaptability to different technologies. The Radio Over Fiber (ROF) technology in which the modulated radio frequency signals are optically modulated and transported through the optical fibers, largely reduce the installation costs and complexity. The present work describes a low-cost DPSK based full duplex two channel ROF communication system between a central station and two base stations in which the optical carrier frequency in the downlink is recovered and reused in the uplink communication.

42 ENGINEERING↗

Automated Reaction Kinetics of Gas-Phase Organic Species over Multiwell Potential Energy Surfaces

Automation of rate-coefficient calculations for gas-phase organic species became possible in recent years and has transformed how we explore these complicated systems computationally. Kinetics workflow tools bring rigor and speed and eliminate a large fraction of manual labor and related error sources. In this paper we give an overview of this quickly evolving field and illustrate, through five detailed examples, the capabilities of our own automated tool, KinBot. Here we bring examples from combustion and atmospheric chemistry of C-, H-, O-, and N-atom-containing species that are relevant to molecular weight growth and autoxidation processes. The examples shed light on the capabilities of automation and also highlight particular challenges associated with the various chemical systems that need to be addressed in future work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intrinsic selectivity and structure sensitivity of Rhodium catalysts for C 2+ oxygenate production [On the intrinsic selectivity and structure sensitivity of Rhodium catalysts for C 2+ oxygenate production]

Synthesis gas (CO + H 2 ) conversion is a promising route to converting coal, natural gas, or biomass into synthetic liquid fuels. Rhodium has long been studied as it is the only elemental catalyst that has demonstrated selectivity to ethanol and other C 2+ oxygenates. However, the fundamentals of syngas conversion over rhodium are still debated. In this work a microkinetic model is developed for conversion of CO and H 2 into methane, ethanol, and acetaldehyde on the Rh (211) and (111) surfaces, chosen to describe steps and close-packed facets on catalyst particles. The model is based on DFT calculations using the BEEF-vdW functional. The mean-field kinetic model includes lateral adsorbate–adsorbate interactions, and the BEEF-vdW error estimation ensemble is used to propagate error from the DFT calculations to the predicted rates. The model shows the Rh(211) surface to be ~6 orders of magnitude more active than the Rh(111) surface, but highly selective toward methane, while the Rh(111) surface is intrinsically selective toward acetaldehyde. A variety of Rh/SiO 2 catalysts are synthesized, tested for catalytic oxygenate production, and characterized using TEM. The experimental results indicate that the Rh(111) surface is intrinsically selective toward acetaldehyde, and a strong inverse correlation between catalytic activity and oxygenate selectivity is observed. Furthermore, iron impurities are shown to play a key role in modulating the selectivity of Rh/SiO 2 catalysts toward ethanol. The experimental observations are consistent with the structure-sensitivity predicted from theory. As a result, this work provides an improved atomic-scale understanding and new insight into the mechanism, active site, and intrinsic selectivity of syngas conversion over rhodium catalysts and may also guide rational design of alloy catalysts made from more abundant elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating PV power from aggregate power measurements within the distribution grid

The increased integration of photovoltaic (PV) systems in distribution grids reduces visibility and situational awareness for utilities because the PV systems' power production is usually not monitored by them. To address this problem, a method called Contextually Supervised Source Separation (CSSS) has been recently adapted for real-time estimation of aggregate PV active power generation from aggregate net active and reactive power measurements at a point in a radially configured distribution grid (e.g., substation). In its original version, PV disaggregation is formulated as an optimization problem that fits linear regression models for the aggregate PV active power generation and true substation active power load. This paper extends the previous work by adding regularization terms in the objective function to capture additional contextual information such as smoothness, by adding new constraints, by introducing new regressors such as ambient temperature, and by investigating the use of time-varying regressors. Furthermore, we perform extensive parametric analysis to study tuning of the objective function weighting factors in a way that maximizes performance and robustness. The proposed PV disaggregation method can be applied to networks with either a single PV system (e.g., megawatt scale) or many distributed ones (e.g., residential scale) connected downstream of the substation. Simulation studies with real field recorded data show that the enhancements of the proposed method reduce disaggregation error by 58% in winter and 35% in summer compared to previous CSSS-based work. When compared against a commonly used transposition model based approach, the reduction in disaggregation error is more pronounced (78% reduction in winter and 45% in summer). Additional simulations indicate that the proposed algorithm is also applicable for PV systems with time-varying power factors. In conclusion, overall, our results show that—with appropriate modeling and tuning—it is possible to accurately estimate the aggregated PV active power generation of a distribution feeder with minimal or no additional sensor deployment.

14 SOLAR ENERGY↗

Correlation-aware binning for small-angle neutron scattering via Gaussian-process inference

Binning in small-angle neutron scattering (SANS) is typically performed empirically, with fixed parameters chosen for convenience rather than statistical optimality. Such practices often fail to balance statistical precision and spatial resolution, leading to inconsistencies across instruments and datasets. Here we establish a correlation-aware framework that determines the optimal bin width from first principles by extending the classical Freedman–Diaconis (FD) rule to account for inter-bin correlations with a Gaussian process. In this formulation, the scattering intensity is treated as a smooth stochastic field whose statistical coherence is described by a covariance matrix. Analytical expressions of errors derived from this model yield closed-form criteria that separate the total deviation into contributions from counting noise, aliasing distortion and curvature-dependent correlation effects. Expressed in reduced variables, the resulting dimensionless error surface reveals a continuous transition from the uncorrelated FD regime to the correlation-dominated limit, providing a unified description of noise suppression and resolution control. Because the formulation depends only on the profile characteristics of scattering intensity I(Q), specifically its average intensity and first- and second-order derivatives, it applies generally to any SANS measurement regardless of sample, instrument or geometry. Experimental validation using small- and ultra-small-angle neutron scattering data confirms the predicted scaling behavior, demonstrating that correlation-aware inference systematically reduces mean-squared error and enables information-efficient reproducible data reduction across materials and instruments.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

A Review of Human Reliability Needs in the U.S. Nuclear Industry

In this survey, 34 subject matter experts from the U.S. nuclear industry were interviewed to determine specific needs for human reliability analysis (HRA). Conclusions from the interviews are detailed in this article. A summary of the findings includes: (1) The need for improved guidance on the use of HRA methods generally and for specific applications. (2) The need for additional training in HRA to provide more hands-on experience in the application of HRA methods. (3) Thedevelopment of HRA approaches suitable for advanced reactors, severe accident situations, and low-power and shutdown applications. (4) The refinement of HRA methods to account forfactors such as crew variability, latent errors, more sophisticated dependency modeling, and errors of commission. (5) The continued need for simplified HRA methods appropriate for field applications. (6) The need for tighter coupling of HRA and human factors. (7) The need for improvements in the quantitative basis of HRA methods. These findings suggest the field of HRA is mature but still benefits from refinements.

human reliability analysis↗

WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration

Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints in the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.

60 APPLIED LIFE SCIENCES↗