Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Microgrid Cyber Security Reference Architecture (V.1.0)

This document summarizes the on-going cyber security work and resulting cyber security reference architecture for a secure microgrid control system network. The architecture pre sented here provides guidelines and security recommendations for the implementation of a secure microgrid control system at Department of Defense (DOD) installations. The mi crogrid is designed using the Energy Surety MicrogridTM (ESM) methodology developed by Sandia National Laboratories (SNL). Microgrids developed using the ESM methodology demonstrate— • increased reliability for critical mission loads resulting from the interconnection of electrical generation assets using the existing distribution network • reduced reliance on diesel-generated backup power through the use of renewable energy sources during outages • increased efficiency of diesel backup generators through careful, coordinated operation across the microgrid system • reduced operational risk through a strong focus on cyber security The design of a microgrid control system needs to be more robust than that of a traditional industrial control system (ICS) for the following reasons: • The microgrid is used in emergency situations and may be critical to continuity of operations of an installation. • The microgrid must function during active attack by a capable adversary. As such, the traditional design and implementation for an ICS may not be sufficient for implementing a robust and secure microgrid.

Veitch, Cynthia K.↗

Optimization and Control Theory for Smart (Power) Grids [Slides]

The national interest in a broad class of problems loosely characterized as the smart grid is rapidly growing. At its core, the smart grid is the modernization of our existing electric power systems through improvements in efficiency, increased robustness and resiliency, integration of time-variable renewable generation, and reduction of environmental impacts. To date, the focus of most commercial entities has been on development of hardware such as smart meters and green technologies. However, with the exception of a handful of academic researchers, there has been limited research on optimization, control and more broadly, the information science required to effectively utilize this hardware. Our proposal targets development of the basic information science that will effectively bridge this gap. Using our expertise in information theory, network analysis, infrastructure analysis and power engineering, we will develop new algorithms for optimal design of the nation's next generation power transmission and distribution system that address the realities and challenges of the future grid. We focus on three core information science challenges in Grid Design, Grid Control and Grid Stability by considering a set of challenging problems. First, we study efficient and robust integration of geographically widespread renewable generation by solving large, cutting-edge optimization problems that incorporate difficult constraints imposed by the transmission of electrical power. Second, we consider two load balancing problems in the low-voltage distribution grid: development of robust and efficient distributed control techniques and algorithms based on queuing theory. These tools will enable high penetration of small-scale distributed generation and plug-in hybrid vehicles with limited or no communications. We will also develop efficient control algorithms for maintaining an operational distribution grid via switching of redundant lines. Third, we will develop a preventive toolbox capable of detecting instabilities and failures prior to their occurrence. Damaging failures and cascading outages, which can result in billions of dollars worth of damage, have substantial economic consequences. We will focus on estimating the probability of these outages, identifying their signatures and precursors, and developing detection algorithms for alerting the transmission grid operator. The new challenges in IS&T for smart grids require coherent advances in analysis and control, stability and reliability metrics, state estimation, data aggregation and assimilation, and communication middleware for the grid as well as understanding consumer response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Development of an Integrated Workstation Automation Hub

Miscellaneous Electronic Loads (MELs) account for one third of all electricity consumption in U.S. commercial buildings, and are drivers for a significant energy use in India. Many of the MEL-specific plug-load devices are concentrated at workstations in offices. The use of intelligence, and integrated controls and communications at the workstation for an Office Automation Hub – offers the opportunity to improve both energy efficiency and occupant comfort, along with services for Smart Grid operations. Software and hardware solutions are available from a wide array of vendors for the different components, but an integrated system with interoperable communications is yet to be developed and deployed. In this study, we propose system- and component-level specifications for the Office Automation Hub, their functions, and a prioritized list for the design of a proof-of-concept system. Leveraging the strength of both the U.S. and India technology sectors, this specification serves as a guide for researchers and industry in both countries to support the development, testing, and evaluation of a prototype product. Further evaluation of such integrated technologies for performance and cost is necessary to identify the potential to reduce energy consumptions in MELs and to improve occupant comfort.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Can a Nuclear-Assisted Biofuels System Enable Liquid Biofuels as the Economic Low-carbon Replacement for All Liquid Fossil Fuels and Hydrocarbon Feedstocks and Enable Negative Carbon Emissions?

This report integrates the results of a series of studies and workshops to address the question: Can a nuclear-assisted biofuels system enable liquid biofuels as the economic low-carbon replacement for all liquid fossil fuels and hydrocarbon feedstocks and simultaneously enable negative carbon emissions? “Economic” is defined as economically competitive relative to other low-carbon replacement options for crude oil. “All” refers to the capability to replace the 18 million barrels of oil per day used by the United States. “Nuclear-assisted” refers to the provision of massive quantities of low-carbon heat and hydrogen at the refinery to fully utilize the carbon content of the cellulosic biomass feedstocks for liquid hydrocarbon production. A system is proposed that decarbonizes about half of the U.S. economy while improving long-term soil productivity and sequestering carbon from the atmosphere. In the U.S. almost half the energy consumed by the final customer is in the form of liquid hydrocarbons produced from crude oil. Liquid hydrocarbons are used as (1) an energy source, (2) a method for daily-to-seasonal energy storage, (3) a chemical feedstock, (4) a chemical reducing agent, (5) a method to enhance high-temperature heat transfer in many furnaces and industrial processes and (6) other purposes. As a consequence, the U.S. consumes ~18 million barrels of crude oil per day to produce liquid hydrocarbons. While there are substitutes for liquid hydrocarbons for some applications, our assessment is that the costs and difficulty will dramatically increase if liquid hydrocarbon use goes much below the equivalent of 10 million barrels per day of crude oil. New uses of liquid hydrocarbons to partly replace coal and natural gas could increase demand beyond the equivalent of 10 million barrels of oil per day. One can produce and burn liquid hydrocarbons from biomass without any net addition of carbon dioxide to the atmosphere. Plants grow by removing carbon dioxide from the atmosphere; thus, burning biomass does not result in any net addition of carbon dioxide to the atmosphere. Biomass is typically 40% oxygen. To remove this oxygen to create hydrocarbon liquids, there are two options. The first option is to use biomass as (1) a feedstock, (2) an energy source to operate the process and (3) a supply of carbon to remove the biomass oxygen as carbon dioxide. The second option is to use external heat and hydrogen to remove the oxygen as water and produce liquid hydrocarbons. The use of massive quantities of external heat and hydrogen for hydrocarbon liquid fuels production reduces the biomass feedstock per unit of liquid hydrocarbon product by more than a factor of two reducing land use by more than a factor of two. Many cellulosic feedstocks unsuitable for liquid hydrocarbon production are viable feedstocks with external heat and hydrogen inputs. As a result, there is sufficient cellulosic feedstocks to meet U.S. and global liquid fuels hydrocarbon demand without significant impacts on food and fiber prices. The heat and hydrogen (heat plus electricity) are produced using base-load nuclear power plants—the most economic form of nuclear energy. If low-price natural gas, there is also the option of producing hydrogen from natural gas with sequestration of the carbon dioxide. The biomass is locally processed in depots to produce commodity feedstocks that can be shipped long distances to large biorefineries (250,000 barrels per day, oil equivalent) similar to existing refineries except modifications of front-end processes. The depot system enables local recycle of nutrients back to the soil. The biorefinery can produce variable quantities of liquid hydrocarbon fuels and carbon dioxide for sequestration enabling removal of carbon dioxide from the atmosphere. Preliminary estimates are that the liquid hydrocarbon costs are equivalent to crude oil at between $60 and $70 per barrel. The largest cost is for hydrogen with biomass feedstocks and refinery costs a smaller fraction of the total cost.

09 BIOMASS FUELS↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

One Earth Energy FEED Process Design Basis

This report establishes the process design basis for the front-end engineering design (FEED) of a carbon capture and injection facility at One Earth Energy's (OEE) ethanol production plant in Gibson City, Illinois, developed as part of the Illinois Storage Corridor CarbonSAFE Phase III project. The facility is designed to compress and dehydrate up to approximately 458,000 metric tonnes of CO 2 per year, sourced directly from OEE's ethanol fermenters, for permanent injection into a saline aquifer approximately four miles from the plant. At normal operating conditions, the system will process 1,290 metric tonnes of CO 2 per day, assuming 355 operating days per year and an ethanol production rate of 160 million gallons per year. The proposed process trains a multistage centrifugal blower with a five-stage reciprocating compressor, delivering CO 2 to the injection wellhead at up to 1,500 psig. Triethylene glycol (TEG) dehydration, applied after the fourth compression stage, reduces water content to a target of 10 lb/MMscf, well within the 30 lb/MMscf injection limit. Beyond dehydration, no additional treatment is required; trace impurities including oxygen and nitrogen will remain in the injected stream. Key design considerations include the absence of spare cooling tower capacity at the site, necessitating new cooling infrastructure, and the need for a new electrical substation to support large motor loads. The facility is designed for continuous, largely unattended operation, monitored around the clock by existing OEE operations staff. This document serves as the foundational reference for all subsequent detailed engineering activities associated with the OEE CO 2 injection facility.

01 COAL, LIGNITE, AND PEAT↗

Thin Silicon MEMS Contact-Stress Sensor

This thin, MEMS contact-stress (CS) sensor continuously and accurately measures time-varying, solid interface loads in embedded systems over tens of thousands of load cycles. Unlike all other interface load sensors, the CS sensor is extremely thin (< 150 {micro}m), provides accurate, high-speed measurements, and exhibits good stability over time with no loss of calibration with load cycling. The silicon CS sensor, 5 mm{sup 2} and 65 {micro}m thick, has piezoresistive traces doped within a load-sensitive diaphragm. The novel package utilizes several layers of flexible polyimide to mechanically and electrically isolate the sensor from the environment, transmit normal applied loads to the diaphragm, and maintain uniform thickness. The CS sensors have a highly linear output in the load range tested (0-2.4 MPa) with an average accuracy of {+-} 1.5%.

42 ENGINEERING↗

Ambient and Initial Temperature Effects on Energy Consumption Rate Modeled in FASTSim

Ambient and initial temperatures significantly impact the energy consumption rate (ECR) of battery electric vehicles (BEVs) due to auxiliary loads and the temperature dependence of battery efficiency. This study introduces a streamlined, physics-based thermal modeling approach within the FASTSim tool that bridges the gap between oversimplified constant-load models and computationally expensive high-fidelity simulations. By employing a lumped thermal mass framework, the model captures fundamental energy balances and critical non-linear energy penalties while maintaining the computational efficiency required for expansive sensitivity studies. The simulations evaluated a compact BEV hatchback with a resistive heater over city (UDDS) and highway (HWFET) test cycles. Compared to a 22 degrees Celsius initial and ambient temperature baseline, a -7 degrees Celsius initial/ambient temperature resulted in a 221% increase in the ECR for the city cycle and a 100% increase for the highway cycle. Conversely, a 45 degrees Celsius initial / 40 degrees Celsius ambient temperature resulted in a 40% increase for UDDS and an 18% increase for HWFET. These results demonstrate that while cold conditions impose the most severe energy penalties due to resistive heating, the impact is consistently more pronounced in city driving where auxiliary loads represent a larger proportion of total energy. This lightweight yet robust framework enables researchers to rapidly quantify BEV thermal sensitivity across diverse climates without the need for high-overhead simulation environments.

33 ADVANCED PROPULSION SYSTEMS↗

Autonomous power subsystem design for an Outer Planet Spacecraft.

This paper describes the overall design of the Thermoelectric Outer Planet Spacecraft (TOPS) power subsystem. It discusses the implementation of spacecraft requirements into a fault-tolerant design in which an on-board self-test and repair computer is utilized to provide autonomous operation. Development of a protected bus concept is discussed whereby electrical power supplied to essential spacecraft loads is maintained in the event of major on-board power blackouts. Particular attention is given to describing the interfaces and operation of the power subsystem with the spacecraft control computer subsystem. Autonomous power management operations are discussed where the on-board computer adjusts the spacecraft load demand to provide maximum utilization of source power for a given mission mode.

Andrews, R. E.↗

Carbon fiber study. A compilation of an intergovernmental committee study

Carbon fibers have opened a wealth of new structural engineering and consumer product opportunities. The potential benefits are higher strength, and lighter weight military and commercial products, which portend energy savings and increases safety. Unfortunately, these benefits are not realized without risk. Inadvertent fiber release, during manufacture or by destruction of the resin binder in fire, is the major hazard associated with composites. The carbon (or graphite) fibers are finer than human hair and if released into the air, they can be easily transported by winds or currents. In contact with electrical devices, they can create resistive loading, short circuits, and arcing, resulting in stoppages or destruction. Their health impact is not fully known and requires careful research and analysis before any firm conclusions can be reached; however, based upon current available information, they are primarily an irritant to the eyes and skin, like fiberglass, rather than carcinogenic or destructive to lung tissue. Major manufacturers are aware of the unique problems associated with these materials and have successfully applied controls to avoid the inplant problems.

Source record↗

A program for the calculation of paraboloidal-dish solar thermal power plant performance

A program capable of calculating the design-point and quasi-steady-state annual performance of a paraboloidal-concentrator solar thermal power plant without energy storage was written for a programmable calculator equipped with suitable printer. The power plant may be located at any site for which a histogram of annual direct normal insolation is available. Inputs required by the program are aperture area and the design and annual efficiencies of the concentrator; the intercept factor and apparent efficiency of the power conversion subsystem and a polynomial representation of its normalized part-load efficiency; the efficiency of the electrical generator or alternator; the efficiency of the electric power conditioning and transport subsystem; and the fractional parasitic loses for the plant. Losses to auxiliaries associated with each individual module are to be deducted when the power conversion subsystem efficiencies are calculated. Outputs provided by the program are the system design efficiency, the annualized receiver efficiency, the annualized power conversion subsystem efficiency, total annual direct normal insolation received per unit area of concentrator aperture, and the system annual efficiency.

Bowyer, J. M., Jr.↗

CELCAP: A Computer Model for Cogeneration System Analysis

A description of the CELCAP cogeneration analysis program is presented. A detailed description of the methodology used by the Naval Civil Engineering Laboratory in developing the CELCAP code and the procedures for analyzing cogeneration systems for a given user are given. The four engines modeled in CELCAP are: gas turbine with exhaust heat boiler, diesel engine with waste heat boiler, single automatic-extraction steam turbine, and back-pressure steam turbine. Both the design point and part-load performances are taken into account in the engine models. The load model describes how the hourly electric and steam demand of the user is represented by 24 hourly profiles. The economic model describes how the annual and life-cycle operating costs that include the costs of fuel, purchased electricity, and operation and maintenance of engines and boilers are calculated. The CELCAP code structure and principal functions of the code are described to how the various components of the code are related to each other. Three examples of the application of the CELCAP code are given to illustrate the versatility of the code. The examples shown represent cases of system selection, system modification, and system optimization.

Source record↗

End-Loaded, Cavity-Backed, Cross-Slot Antennas

End-loaded, cavity-backed, cross-slot antennas developed for use in mobile/satellite service and other similar commercial services. Intended to transmit and receive in circular polarization at frequencies between 1 and 2 GHz. Fabricated and tuned to operating frequencies easily. Made without end loading or with end loading tailored to obtain various desirable electrical characteristics. Advantages include lower losses, lighter weights, smaller sizes, and greater bandwidths.

Manshadi, Farzin↗

Active member bridge feedback control for damping augmentation

An active damping augmentation approach using active members in a structural system is described. The problem of maximizing the vibration damping in a lightly damped structural system is considered using the analogy of impedance matching between the load and source impedances in an electrical network. The proposed active damping augmentation approach therefore consists of finding the desired active member impedances that maximize the vibration damping, and designing a feedback control in order to achieve desired active member impedances. This study uses a bridge feedback concept that feeds back a combination of signals from sensors of the axial force and relative velocity across the active member to realize the desired active member impedance. The proposed active damping augmentation approach and bridge feedback concept were demonstrated on a three-longeron softly suspended truss structure.

Chen, Gun-Shing↗