Full data acquisition in Kelvin Probe Force Microscopy: Mapping dynamic electric phenomena in real space

Kelvin probe force microscopy (KPFM) has provided deep insights into the role local electronic, ionic and electrochemical processes play on the global functionality of materials and devices, even down to the atomic scale. Conventional KPFM utilizes heterodyne detection and bias feedback to measure the contact potential difference (CPD) between tip and sample. This measurement paradigm, however, permits only partial recovery of the information encoded in bias- and time-dependent electrostatic interactions between the tip and sample and effectively down-samples the cantilever response to a single measurement of CPD per pixel. This level of detail is insufficient for electroactive materials, devices, or solid-liquid interfaces, where non-linear dielectrics are present or spurious electrostatic events are possible. Here, we simulate and experimentally validate a novel approach for spatially resolved KPFM capable of a full information transfer of the dynamic electric processes occurring between tip and sample. General acquisition mode, or G-Mode, adopts a big data approach utilising high speed detection, compression, and storage of the raw cantilever deflection signal in its entirety at high sampling rates (> 4 MHz), providing a permanent record of the tip trajectory. We develop a range of methodologies for analysing the resultant large multidimensional datasets involving classical, physics-based and information-based approaches. Physics-based analysis of G-Mode KPFM data recovers the parabolic bias dependence of the electrostatic force for each cycle of the excitation voltage, leading to a multidimensional dataset containing spatial and temporal dependence of the CPD and capacitance channels. We use multivariate statistical methods to reduce data volume and separate the complex multidimensional data sets into statistically significant components that can then be mapped onto separate physical mechanisms. Overall, G-Mode KPFM offers a new paradigm to study dynamic electric phenomena in electroactive interfaces as well as offer a promising approach to extend KPFM to solid-liquid interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Midlatitude Oceanic Cloud and Precipitation Properties as Sampled By the ARM Eastern North Atlantic Observatory

Marine low clouds are critical to the climate system because of their extensive coverage and associated controls on boundary layer dynamics and radiative energy balance. The primary foci for this study are marine low cloud observations over a heavily instrumented site on the Azores archipelago in the eastern North Atlantic (ENA) and their associated raindrop size distribution (DSD) properties, relative low-cloud contributions to the precipitation, and additional sampling (instrument, environmental) considerations. The contribution from low clouds (e.g., cloud top < 4 km) to the overall precipitation over midlatitude oceans is poorly understood, in part because of the lack of coupled, high-quality measurements of precipitation and low-cloud properties. Cloud regime and precipitation breakdowns performed for a multi-year record emphasize the diurnal precipitation cycle and DSD characteristics for both low and deeper clouds. Results demonstrate that marine low clouds over this ENA location account for a significant (45%) contribution to the total rainfall and exhibit a diurnal cycle in cloud (thickness, top, base) and precipitation characteristics similar to satellite records. Additional controls on observed surface rainfall characteristics of low clouds allowed by the extended ground-based facility datasets are also explored. From those analyses, it is suggested that the synoptic state exerts a significant control on low-cloud and surface precipitation properties.

Giangrande, Scott↗

Optimized Uncertainty Quantification Algorithm Within a Dynamic Event Tree Framework

Methods for developing Phenomenological Identification and Ranking Tables (PIRT) for nuclear power plants have been a useful tool in providing insight into modelling aspects that are important to safety. These methods have involved expert knowledge with regards to reactor plant transients and thermal-hydraulic codes to identify are of highest importance. Quantified PIRT provides for rigorous method for quantifying the phenomena that can have the greatest impact. The transients that are evaluated and the timing of those events are typically developed in collaboration with the Probabilistic Risk Analysis. Though quite effective in evaluating risk, traditional PRA methods lack the capability to evaluate complex dynamic systems where end states may vary as a function of transition time from physical state to physical state . Dynamic PRA (DPRA) methods provide a more rigorous analysis of complex dynamic systems. A limitation of DPRA is its potential for state or combinatorial explosion that grows as a function of the number of components; as well as, the sampling of transition times from state-to-state of the entire system. This paper presents a method for performing QPIRT within a dynamic event tree framework such that timing events which result in the highest probabilities of failure are captured and a QPIRT is performed simultaneously while performing a discrete dynamic event tree evaluation. The resulting simulation results in a formal QPIRT for each end state. The use of dynamic event trees results in state explosion as the number of possible component states increases. This paper utilizes a branch and bound algorithm to optimize the solution of the dynamic event trees. The paper summarizes the methods used to implement the branch-and-bound algorithm in solving the discrete dynamic event trees.

42 ENGINEERING↗

Time-resolved x-ray diffraction techniques for bulk polycrystalline materials under dynamic loading

We have developed two techniques for time-resolved x-ray diffraction from bulk polycrystalline materials during dynamic loading. In the first technique, we synchronize a fast detector with loading of samples at strain rates of ∼10{sup 3}–10{sup 4} s{sup −1} in a compression Kolsky bar (split Hopkinson pressure bar) apparatus to obtain in situ diffraction patterns with exposures as short as 70 ns. This approach employs moderate x-ray energies (10–20 keV) and is well suited to weakly absorbing materials such as magnesium alloys. The second technique is useful for more strongly absorbing materials, and uses high-energy x-rays (86 keV) and a fast shutter synchronized with the Kolsky bar to produce short (∼40 μs) pulses timed with the arrival of the strain pulse at the specimen, recording the diffraction pattern on a large-format amorphous silicon detector. For both techniques we present sample data demonstrating the ability of these techniques to characterize elastic strains and polycrystalline texture as a function of time during high-rate deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing dynamical symmetry breaking using quantum-entangled photons

Here, we present an input/output analysis of photon-correlation experiments whereby a quantum mechanically entangled bi-photon state interacts with a material sample placed in one arm of a Hong–Ou–Mandel apparatus. We show that the output signal contains detailed information about subsequent entanglement with the microscopic quantum states in the sample. In particular, we apply the method to an ensemble of emitters interacting with a common photon mode within the open-system Dicke model. Our results indicate considerable dynamical information concerning spontaneous symmetry breaking can be revealed with such an experimental system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of PDMS- g -PDMS Bottlebrush Polymers by Broadband Dielectric Spectroscopy

Poly(dimethylsiloxane) (PDMS)-based bottlebrush polymers, PDMS-g-PDMS, have been synthesized by anionic polymerization in combination with a condensation-based grafting reaction. Bottlebrush polymers show intriguing features, e.g., extremely low viscosities. Hereby, studies of their dynamics are rare. Therefore, we focus on the segmental relaxation by broadband dielectric spectroscopy. An increasing cross-sectional radius proportional to the increasing side chain length has been observed by small-angle neutron scattering over three samples. Here, a comparison of the segmental relaxation times of the bottlebrushes with the respective linear chains reveals slower dynamics in the former. For longer chains, this effect vanishes.

36 MATERIALS SCIENCE↗

Mechanisms of material removal and mass transport in focused ion beam nanopore formation

Despite the widespread use of focused ion beam (FIB) processing as a material removal method for applications ranging from electron microscope sample preparation to nanopore processing for DNA sequencing, the basic material removal mechanisms of FIB processing are not well understood. We present the first complete atomistic simulation of high-flux FIB using large-scale parallel molecular dynamics (MD) simulations of nanopore fabrication in freestanding thin films. We focus on the root mechanisms of material removal and rearrangement and describe the role of explosive boiling in forming nanopores. FIB nanopore fabrication is typically understood to occur via sputter erosion. This can be shown to be the case in low flux systems, where individual ion impacts are sufficiently separated in time that they may be considered as independent events. But our detailed MD simulations show that in high flux FIB processing, above a threshold level at which thermal effects become significant, the primary mechanism of material removal changes to a significantly accelerated, thermally dominated process. Under these conditions, the target is heated by the ion beam faster than heat is conducted away by the material, leading quickly to melting, and then continued heating to nearly the material critical temperature. This leads to explosive boiling of the target material with spontaneous bubble formation and coalescence. Mass is rapidly rearranged at the atomistic scale, and material removal occurs orders of magnitude faster than would occur by simple sputtering. While the phenomenology is demonstrated computationally in silicon, it can be expected to occur at lower beam fluxes in other cases where thermal conduction is suppressed due to material properties, geometry, or ambient thermal conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Realization of higher thermoelectric performance by dynamic doping of copper in n-type PbTe

It is a great challenge to optimize a material's thermoelectric performance due to the strong correlation between its thermoelectric-transport properties, especially the electrical-transport properties. Optimizing the peak zT using a constant carrier concentration is commonly adopted because of the difficulty in realizing the optimum temperature-dependent carrier concentration, but this is not meaningful for real applications, in which the average zT value over the working temperature range is much more important. Here we propose an effective strategy involving the dynamic doping effect of interstitial Cu atoms to fully optimize the electrical-transport properties of n-type PbTe over a wide temperature range. By using Cu intercalation, the temperature-dependent carrier concentration of PbTe is found to well match the theoretically optimal profile. Furthermore, high carrier mobility is largely maintained because the dynamic behavior of the interstitial Cu does not alter the band structure and therefore change the effective mass. Consequently, a peak zT of ~1.3 and a calculated leg efficiency of 12% were achieved for the sample with 0.2 at% Cu. Based on our findings, we further proposed a concept of ‘interstitial engineering’ to reinforce the dynamic doping effect, which is of fundamental importance for optimizing the thermoelectric properties.

25 ENERGY STORAGE↗

Impact of Inverter-Interfaced Renewable Generation on Transient Stability at Varying Levels of Penetration: Preprint

The transient dynamics of conventional power systems are dominated by synchronous generators, and low-inertia inverters serve as the primary interface between power systems and renewable energy resources. Increasing penetration levels of inverter-interfaced generation are impacting the transient dynamics of power systems. In this paper, we attempt to quantify these impacts at different penetration levels. An elementary system including one inverter, one synchronous generator, and one load is studied under different parameter variations to assess the transient dynamics of the system. To quantify transient stability, the post-fault regions of attraction of the system are estimated by the sample-based basin stability approach with parallel computing technology. The simulation results suggest that different inverter penetration levels, inertias of the generator, inverter controller gains, and phase-locked loop controller gains have a clear impact on the regions of attraction as well as on the transient dynamics of proposed systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NID Copper Sample Analysis

The current focal point of the nuclear physics program at PNNL is the MAJORANA DEMONSTRATOR, and the follow-on Tonne-Scale experiment, a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0νββ). This experiment requires the use of germanium isotopically enriched in 76Ge. The DEMONSTRATOR will utilize 76Ge from Russia, but for the Tonne-Scale experiment it is hoped that an alternate technology under development at Nonlinear Ion Dynamics (NID) will be a viable, US-based, lower-cost source of separated material. Samples of separated material from NID require analysis to determine the isotopic distribution and impurities. The MAJORANA DEMONSTRATOR is a DOE and NSF funded project with a major science impact. DOE is funding NID through an SBIR grant for development of their separation technology for application to the Tonne-Scale experiment. The Environmental Molecular Sciences facility (EMSL), a DOE user facility at PNNL, has the required mass spectroscopy instruments for making these isotopic measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR and for the development of the future separation technology required for the Tonne-Scale experiment. A sample of isotopically separated copper was provided by NID to PNNL for isotopic analysis as a test of the NID technology. The results of that analysis are reported here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

General trends of dihedral conformational transitions in a globular protein

In this paper, dihedral conformational transitions are analyzed systematically in a model globular protein, cytochrome P450cam, to examine their structural and chemical dependences through combined conventional molecular dynamics (cMD), accelerated molecular dynamics (aMD) and adaptive biasing force (ABF) simulations. The aMD simulations are performed at two acceleration levels, using dihedral and dual boost, respectively. In comparison with cMD, aMD samples protein dihedral transitions approximately two times faster on average using dihedral boost, and ~3.5 times faster using dual boost. In the protein backbone, significantly higher dihedral transition rates are observed in the bend, coil, and turn flexible regions, followed by the β bridge and β sheet, and then the helices. Moreover, protein side chains of greater length exhibit higher transition rates on average in the aMD-enhanced sampling. Side chains of the same length (particularly Nχ = 2) exhibit decreasing transition rates with residues when going from hydrophobic to polar, then charged and aromatic chemical types. The reduction of dihedral transition rates is found to be correlated with increasing energy barriers as identified through ABF free energy calculations. In conclusion, these general trends of dihedral conformational transitions provide important insights into the hierarchical dynamics and complex free energy landscapes of functional proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Formation of helices with controllable chirality in gel-fiber composites

While microscale helices with specified chirality are pervasive in biological systems, driving purely synthetic materials to self-organize into such useful structures remains a significant challenge. Through theory and simulations, we model the behavior of initially flat ribbons of gel-fiber composites and show that these materials self-organize into three-dimensional helices with the application of heat. We specifically focus on thermo-responsive gels, which shrink when heated to a point near the lower critical solubility temperature (LCST). Within the composite, regions of the LCST gel that lie far from the fibers can readily shrink in response to the increased temperature; however, near the fibers the network is inhibited from undergoing the heat-induced collapse. This competition between the constrained and the unconstrained regions of the heated sample plays a vital role in the structural evolution of the material. Additionally, we find that this dynamic process can be controlled through the careful placement of the fibers on the outer surface of the gel. We specifically identify fiber arrangements that lead to the formation of helical structures with controlled chirality. Moreover, we isolate scenarios where constraining the movement of one or both the free ends of the sample promotes and stabilizes the formation of helical structures with specified handedness. Such structurally tailored composites are useful for creating mechanically robust actuators, and “appendages” for soft robots that can controllably curl and uncurl with variations in temperature.

36 MATERIALS SCIENCE↗

Dynamic Resistance of YBCO-Coated Conductors in Applied AC Fields with DC Transport Currents and DC Background Fields

In order to predict heat loads in future saturable core fault-current-limiting devices due to ac fringing fields, dynamic resistance in YBCO-coated conductors was measured at 77 K in peak ac fields up to 25 mT at 60 Hz and in dc fields up to 1 T. With the sample orientation set such that the conductor face was either parallel or perpendicular to the ac and dc applied fields, the dynamic resistance was measured at different fractions of the critical current to determine the relationship between the dc transport current and the applied fields. With respect to field orientation, the dynamic resistance for ac fields that were perpendicular to the conductor face was significantly higher than when the ac fields were parallel to the conductor face. It was also observed that the dynamic resistance: (1) increased with increasing fraction of the dc transport current to the critical current, (2) was proportional to the inverse of the critical current, and (3) demonstrated a linear dependence with the applied ac field once a threshold field was exceeded. This functional behavior was consistent with a critical state model for the dynamic resistance, but discrepancies in absolute value of the dynamic resistance suggested that further theoretical development is needed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic resolution convergent beam electron diffraction analysis using convolutional neural networks

Two types of convolutional neural network (CNN) models, a discrete classification network and a continuous regression network, were trained to determine local sample thickness from convergent beam diffraction (CBED) patterns of SrTiO 3 collected in a scanning transmission electron microscope (STEM) at atomic column resolution. Acquisition of atomic resolution CBED patterns for this purpose requires careful balancing of CBED feature size in pixels, acquisition speed, and detector dynamic range. The training datasets were derived from multislice simulations, which must be convolved with incoherent source broadening. Sample thicknesses were also determined using quantitative high-angle annular dark-field (HAADF) STEM images acquired simultaneously. The regression CNN performed well on sample thinner than 35 nm, with 70% of the CNN results within 1 nm of HAADF thickness, and 1.0 nm overall root mean square error between the two measurements. The classification CNN was trained for a thicknesses up to 100 nm and yielded 66% of CNN results within one classification increment of 2 nm of HAADF thickness. Our approach depends on methods from computer vision including transfer learning and image augmentation.

36 MATERIALS SCIENCE↗

A Large Sample Volume Magic Angle Spinning Nuclear Magnetic Resonance Probe for In-Situ Investigations with Constant Flow of Reactants

A large-sample-volume constant-flow magic angle sample spinning (CF-MAS) NMR probe is reported for in-situ studies of the reaction dynamics, stable intermediates/transition states, and mechanisms of catalytic reactions. In our approach, the reactants are introduced into the catalyst bed using a fixed tube at one end of the MAS rotor while a second fixed tube, linked to a vacuum pump, is attached at the other end of the rotor. The pressure difference between both ends of the catalyst bed inside the sample cell space forces the reactants flowing through the catalyst bed, which improves the diffusion of the reactants and products. This design allows the use of a large sample volume for enhanced sensitivity and thus permitting in-situ 13C CF-MAS studies at natural abundance. As an example of application, we show that reactants, products and reaction transition states associated with the 2-butanol dehydration reaction over a mesoporous silicalite supported heteropoly acid catalyst (HPA/meso-silicalite-1) can all be detected in a single 13C CF-MAS NMR spectrum at natural abundance. Coke products can also be detected at natural 13C abundance and under the stopped flow condition. Furthermore, 1H CF-MAS NMR is used to identify the surface functional groups of HPA/meso-silicalite-1 under the condition of in-situ drying . We also show that the reaction dynamics of 2-butanol dehydration using HPA/meso-silicalite-1 as a catalyst can be explored using 1H CF-MAS NMR.

01 COAL, LIGNITE, AND PEAT↗

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Status Update for the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSMs) from Orano (formerly Transnuclear Inc.) and provides a description of the surface characterization activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. The goal of the testing is to collect highly defensible and detailed dust deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the decay heat and thermal hydraulic environment. Test and heater design is supported by detailed computational fluid dynamics modeling. Instrumentation throughout the canister, storage module, and environment will provide extensive information about thermal-hydraulic behavior. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment. Functional testing of the finalized heater assemblies and test apparatus is set to begin in December 2022. The proposed delivery of the canisters to the host test site is June/July 2023, which is well ahead of when the AHSM installations would be completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗