Application of a Planar Doppler Velocimetry System to a High Reynolds Number Compressible Jet

A Planar Doppler Velocimetry (PDV) system has been constructed and used to investigate the instantaneous turbulent velocity structure of a round high-speed compressible air jet with a low-speed co-flow. The exit condition was Mach=0.85 at ambient pressure, yielding a Reynolds number of about 650,000 on diameter. The PDV system was installed at NASA Langley Research Center in the Small Anechoic Jet Facility (SAJF), a chamber in which both the acoustic and aerodynamic properties of jets can be studied. For this test, the goal was to gather data which can be used to relate the turbulence structure of the jet to the levels and character of the acoustic noise produced by the jet. The current PDV system can acquire single-velocity-component, single-shot, planar images (15ns exposures) at 30 Hz. For this paper, the primary data set consists of 240 frames of velocity data acquired with both the jet and the low-speed co-flow seeded with light-scattering articles. Thus, velocities could be measured everywhere in the jet shear layer, both in the jet fluid and in the entrained co-flow. Some data were also taken with only the jet flow seeded. These provided mixing concentration images along with the reduced velocity fields. Other images were taken with only the co-flow seeded. These produced unique quantitative images of high speed entrainment. Optical "laser speckle" noise is the largest source of random noise in pulsed PDV systems. Components for the PDV imaging system were specifically selected to minimize speckle noise. To reduce systematic velocity errors due to laser drift, a frequency monitoring reference leg with a temperature-tuned reference iodine cell, was employed. In the course of this study, a novel flow seeder was developed. It enabled continuously variable seeding of the flow with particles of Sheared Pyrogenic Amorphous Hydrophobic Silica (SPAHS). The seeder comprised a dry fluidized bed hopper and a supersonic nozzle "pickup." Shearing action in the pickup dispersed the seed material in an exceptionally fine cloud (approximately 0.3 micron). These particles followed the flow well, did not clump or cake on screens or model surfaces, and were not susceptible to evaporation. Because of the refractory nature of the particles, SPAHS seeding should also be applicable to anticipated future testing at high temperatures.

Smith, Michael W.↗

Hardening Doppler Global Velocimetry Systems for Large Wind Tunnel Applications

The development of Doppler Global Velocimetry from a laboratory curiosity to a wind tunnel instrumentation system is discussed. This development includes system advancements from a single velocity component to simultaneous three components, and from a steady state to instantaneous measurement. Improvements to system control and stability are discussed along with solutions to real world problems encountered in the wind tunnel. This on-going development program follows the cyclic evolution of understanding the physics of the technology, development of solutions, laboratory and wind tunnel testing, and reevaluation of the physics based on the test results.

Meyers, James F.↗

Instantaneous Doppler Global Velocimetry Measurements of a Rotor Wake: Lessons Learned

A combined Doppler Global Velocimetry (DGV) and Projection Moir Interferometry (PMI) investigation of a helicopter rotor wake flow field and rotor blade deformation is presented. The three-component DGV system uses a single-frequency, frequency-doubled Nd:YAG laser to obtain instantaneous velocity measurements in the flow. The PMI system uses a pulsed laser-diode bar to obtain blade bending and twist measurements at the same instant that DGV measured the flow. The application of pulse lasers to DGV and PMI in large-scale wind tunnel applications represents a major step forward in the development of these technologies. As such, a great deal was learned about the difficulties of using these instruments to obtain instantaneous measurements in large facilities. Laser speckle and other image noise in the DGV data images were found to be traceable to the Nd:YAG laser. Although image processing techniques were used to virtually eliminate laser speckle noise, the source of low-frequency image noise is still under investigation. The PMI results agreed well with theoretical predictions of blade bending and twist.

Meyers, James↗

Application of Doppler Global Velocimetry to Supersonic Flows

The design and implementation of Doppler Global Velocimetry (DGV) for testing in the Langley Unitary Plan Wind Tunnel is presented. The discussion begins by outlining the characteristics of the tunnel and the test environment, with potential problem areas highlighted. Modifications to the optical system design to implement solutions for these problems are described. Since this tunnel entry was the first ever use of DGV in a supersonic wind tunnel, the test series was divided into three phases, each with its own goal. Phase I determined if condensation provided sufficient scattered light for DGV applications. Phase II studied particle lag by measuring the flow about an oblique shock above an inclined flat plate. Phase III investigated the supersonic vortical flow field above a 75-degree delta wing at 24-degrees angle of attack. Example results from these tests are presented.

Meyers, James F.↗

Development of Doppler Global Velocimetry as a Flow Diagnostics Tool

The development of Doppler global velocimetry is described from its inception to its use as a flow diagnostics tool. Its evolution is traced from an elementary one-component laboratory prototype, to a full three-component configuration operating in a wind tunnel at focal distances exceeding 15 m. As part of the developmental process, several wind tunnel flow field investigations were conducted. These included supersonic flow measurements about an oblique shock, subsonic and supersonic measurements of the vortex flow above a delta wing, and three-component measurements of a high-speed jet.

Meyers, James F.↗

Estimation of diastolic intraventricular pressure gradients by Doppler M-mode echocardiography

Previous studies have shown that small intraventricular pressure gradients (IVPG) are important for efficient filling of the left ventricle (LV) and as a sensitive marker for ischemia. Unfortunately, there has previously been no way of measuring these noninvasively, severely limiting their research and clinical utility. Color Doppler M-mode (CMM) echocardiography provides a spatiotemporal velocity distribution along the inflow tract throughout diastole, which we hypothesized would allow direct estimation of IVPG by using the Euler equation. Digital CMM images, obtained simultaneously with intracardiac pressure waveforms in six dogs, were processed by numerical differentiation for the Euler equation, then integrated to estimate IVPG and the total (left atrial to left ventricular apex) pressure drop. CMM-derived estimates agreed well with invasive measurements (IVPG: y = 0.87x + 0.22, r = 0.96, P < 0.001, standard error of the estimate = 0.35 mmHg). Quantitative processing of CMM data allows accurate estimation of IVPG and tracking of changes induced by beta-adrenergic stimulation. This novel approach provides unique information on LV filling dynamics in an entirely noninvasive way that has previously not been available for assessment of diastolic filling and function.

Non-NASA Center↗

Determinants of diastolic myocardial tissue Doppler velocities: influences of relaxation and preload

Myocardial tissue Doppler echocardiography (TDE) has been proposed as a tool for the assessment of diastolic function. Controversy exists regarding whether TDE measurements are influenced by preload. In this study, left ventricular volume and high-fidelity pressures were obtained in eight closed-chest dogs during intermittent caval occlusion. The time constant of isovolumic ventricular relaxation (tau) was altered with varying doses of dobutamine and esmolol. Peak early diastolic myocardial (E(m)) and transmitral (E) velocities were measured before and after preload reduction. The relative effects of changes in preload and relaxation were determined for E(m) and compared with their effects on E. The following results were observed: caval occlusion significantly decreased E (DeltaE = 16.4 +/- 3.3 cm/s, 36.6 +/- 13.7%, P < 0.01) and E(m) (DeltaE(m) = 1. 3 +/- 0.4 cm/s, 32.5 +/- 26.1%, P < 0.01) under baseline conditions. However, preload reduction was similar for E under all lusitropic conditions (P = not significant), but these effects on E(m) decreased with worsening relaxation. At tau < 50 ms, changes in E(m) with preload reduction were significantly greater (DeltaE(m) = 2.8 +/- 0.6 cm/s) than at tau = 50-65 ms (DeltaE(m) = 1.2 +/- 0.2 cm/s) and at tau >65 ms (DeltaE(m) = 0.5 +/- 0.1 cm/s, P < 0.05). We concluded that TDE E(m) is preload dependent. However, this effect decreases with worsening relaxation.

NASA Discipline Cardiopulmonary↗

Signal Processing Schemes for Doppler Global Velocimetry

Two schemes for processing signals obtained from the Doppler global velocimeter are described. The analog approach is a simple, real time method for obtaining an RS-170 video signal containing the normalized intensity image. Pseudo colors are added using a monochromatic frame grabber producing a standard NTSC video signal that can be monitored and/or recorded. The digital approach is more complicated, but maintains the full resolution of the acquisition cameras with the capabilities to correct the signal image for pixel sensitivity variations and to remove of background light. Prototype circuits for each scheme are described and example results from the investigation of the vortical flow field above a 75-degree delta wing presented.

Meyers, James F.↗

Three Component Doppler Global Velocimeter Measurements of the Flow Above A Delta Wing

A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. To assess the capability of this new technique, three - component velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA Langley Basic Aerodynamics Research Tunnel. Measurements were made of the flow field at the 70-percent chord location at angles-of-attack of 20.5 and 40.0 degrees to investigate unburst and burst vortices. For comparison, previous fringe-type laser velocimeter measurements of the flow field at the same conditions are included.

Meyers, James F.↗

Investigation of the Vortical Flow Above an F/A-18 Using Doppler Global Velocimetry

The flow above an F/A-18 model, set to 25-degrees angle of attack, was measured using a Doppler global velocimeter, (DGV). The investigation indicated that the complex flow contained many similarities to the vortical flow above a simple delta wing set to a high-angle of attack, including flow standard deviations greater than 30-percent of free- stream. These standard deviation levels were also comparable to results found during a previous investigation of the vortical flow above a YF-17 using fringe-type laser velocimetry. The global measurement capability of the DGV provided the first evidence that the burst vortices above the model were structured. These structures were found to maintain their spatial coherence while the flow varied in an overall sense.

Meyers, James F.↗

Doppler Global Velocimeter Measurements of the Vortical Flow Above a Thin Delta Wing

A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. Data obtained using this technique will be used to correlate with other data sets for verification, and following verification, provide a quantified, highly detailed definition of the flow field. This will help to improve the understanding of fluid physics, supplement and broaden the database required to validate and refine computational fluid dynamics (CFD) models, and improve aircraft design methodology. To assess the capability of the technique, velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA - Langley Basic Aerodynamics Research Tunnel. Preliminary comparisons of the results were made with similar measurements obtained using a three component laser velocimeter indicate that this technique is capable of describing the entire three - component velocity flow field simultaneously within a measurement plane in real time.

Usry, Jimmy W.↗

Doppler Global Velocimetry: The Next Generation?

A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. To assess the capability of this new technique, velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA Langley Basic Aerodynamics Research Tunnel. The operation of the system is described along with the techniques developed to process the output images. The results are then compared with similar measurements obtained using a three component laser velocimeter.

Meyers, James F.↗

Doppler Global Velocimetry Measurements of the Vortical Flow Above an F/A-18

A Doppler global velocimeter was used to investigate the vortical flow above an F/A-18 model at 25-degrees angle of attack. The measurements indicate that the flow had the same characteristics as the vortical flow above a standard delta wing. The flow pattern indicating transition from stable to burst conditions found above the delta wing was also found at the 440 station above the F/A-18. Measurements downstream at the 524 station found that the flow velocity varied considerably, with standard deviations reaching 30 percent of free stream. However, individual data images indicated that the flow was spatially coherent, and not chaotic as expected.

Lee, Joseph W.↗

Assessing the Capability of Doppler Global Velocimetry to Measure Vortical Flow Fields

A new measurement technique, Doppler global velocimetry, has been described along with results from an experimental investigation of a vortical flow field. The results of this investigation, when compared to conventional laser velocimeter measurements, indicate that this technique is capable of describing the global velocity field within a measurement plane in real time. Further investigations are being conducted to correct the deficiencies described and to refine the measurement technique for flight applications.

Usry, Jimmy W.↗

Doppler Global Velocimetry: A New Way to Look at Velocity

A new laser velocimetry technique, Doppler global velocimetry, is described. This technique is capable of simultaneously measuring in real time the three components of velocity of an entire particle field illuminated by a laser light sheet. A prototype one-component velocimeter is described along with the signal processing electronics. The system was tested by measuring the velocity field from a rotating wheel and a small subsonic jet flow in the laboratory. The first wind tunnel test measured the vortical velocity field above a delta wing. The results are presented and compared with fringe-type laser velocimeter and five-hole probe data.

Meyers, James F.↗

Development of Doppler Global Velocimetry for Wind Tunnel Testing

The development of Doppler global velocimetry is described. Emphasis is placed on the modifications necessary to advance this nonintrusive laser based measurement technique from a laboratory prototype to a viable wind tunnel flow diagnostics tool. Several example wind tunnel flow field investigations are described to illustrate the versatility of the technique. Flow conditions ranged from incompressible to Mach 2.8 with measurement distances extending from 1 to 15 m.

Meyers, James F.↗

Investigation of Measurement Errors in Doppler Global Velocimetry

While the initial development phase of Doppler Global Velocimetry (DGV) has been successfully completed, there remains a critical next phase to be conducted, namely the determination of an error budget to provide quantitative bounds for measurements obtained by this technology. This paper describes a laboratory investigation that consisted of a detailed interrogation of potential error sources to determine their contribution to the overall DGV error budget. A few sources of error were obvious; e.g., iodine vapor adsorption lines, optical systems, and camera characteristics. However, additional non-obvious sources were also discovered; e.g., laser frequency and single-frequency stability, media scattering characteristics, and interference fringes. This paper describes each identified error source, its effect on the overall error budget, and where possible, corrective procedures to reduce or eliminate its effect.

Meyers, James F.↗

High Resolution Doppler Imager FY 2001,2002,2003 Operations and Algorithm Maintenance

During the performance period of this grant HRDI (High Resolution Doppler Imager) operations remained nominal. The instrument has suffered no loss of scientific capability and operates whenever sufficient power is available. Generally, there are approximately 5-7 days per month when the power level is too low to permit observations. The daily latitude coverage for HRDI measurements in the mesosphere, lower thermosphere (MLT) region are shown.It shows that during the time of this grant, HRDI operations collected data at a rate comparable to that achieved during the UARS (Upper Atmosphere Research Satellite) prime mission (1991 -1995). Data collection emphasized MLT wind to support the validation efforts of the TIDI instrument on TIMED, therefore fulfilling one of the primary objectives of this phase of the UARS mission. Skinner et al., (2003) present a summary of the instrument performance during this period.

Skinner, Wilbert↗