Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

A large gap of radio frequency dielectric barrier atmospheric pressure glow discharge

A large gap was acquired between electrodes (up to 5.5 mm) of Ar atmospheric pressure glow discharge in radio frequency dielectric barrier discharge (rf-DBD). The discharge of Ar plasma was characterized by I-V curve and Lissajous plot, and the effective power of the discharge was calculated based on the measured Lissajous plot and found to be higher than 90% of the input power. To gain a thorough understanding of the mechanism, the rf-DBD with a single dielectric barrier layer operating in gamma mode glow discharge of N{sub 2} plasma was diagnosed in spatial resolution through optical emission spectroscopy. It was concluded that secondary electron emission might be responsible for the sustainable glow discharge in the large gap rf-DBD plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applied spectroscopy in pulsed power plasmas

Applied spectroscopy is a powerful diagnostic tool for high energy density plasmas produced with modern pulsed power facilities. These facilities create unique plasma environments with a broad range of electron densities (10{sup 13}-10{sup 23} cm{sup -3}) and temperatures (10{sup 0}-10{sup 3} eV) immersed in strong magnetic (>100 T) and electric (up to 1 GV/m) fields. This paper surveys the application of plasma spectroscopy to diagnose a variety of plasma conditions generated by pulsed power sources including: magnetic field penetration into plasma, measuring the time-dependent spatial distribution of 1 GV/m electric fields, opacity measurements approaching stellar interior conditions, characteristics of a radiating shock propagating at 330 km/s, and determination of plasma conditions in imploded capsule cores at 150 Mbar pressures. These applications provide insight into fundamental properties of nature in addition to their importance for addressing challenging pulsed power science problems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High intensity, plasma-induced electron emission from large area carbon nanotube array cathodes

The plasma-induced electron emission properties of large area carbon nanotube (CNT) array cathodes under different pulse electric fields were investigated. The formation and expansion of cathode plasmas were proved; in addition, the cathodes have higher emission current in the double-pulse mode than that in the single-pulse mode due to the expansion of plasma. Under the double-pulse electric field of 8.16 V/mum, the plasma's expansion velocity is about 12.33 cm/mus and the highest emission current density reached 107.72 A/cm{sup 2}. The Cerenkov radiation was used to diagnose the distribution of electron beams, and the electron beams' generating process was plasma-induced emission.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spectroscopic study of a long high-electron-density argon plasma column generated at atmospheric pressure

A stable plasma column is generated in a quartz tube using a pair of hollow electrodes driven by a sinusoidal power supply of 45 kHz at atmospheric pressure in argon. Two distinct operating modes (low-current and high-current modes) are identified through observing its discharge phenomena, measuring its electrical characteristics, and determining the gas temperatures by spectroscopic diagnosis of Q branch of UV OH spectrum. The electron density in the high-current mode is diagnosed by Stark broadening and is found to be two orders higher than that in low-current mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Acceleration to high velocities and heating by impact using Nike KrF laser

The Nike krypton fluoride laser [S. P. Obenschain, S. E. Bodner, D. Colombant, et al., Phys. Plasmas 3, 2098 (1996)] is used to accelerate planar plastic foils to velocities that for the first time reach 1000 km/s. Collision of the highly accelerated deuterated polystyrene foil with a stationary target produces approxGbar shock pressures and results in heating of the foil to thermonuclear temperatures. The impact conditions are diagnosed using DD fusion neutron yield, with approx10{sup 6} neutrons produced during the collision. Time-of-flight neutron detectors are used to measure the ion temperature upon impact, which reaches 2-3 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven plasma jets propagating in an ambient gas studied with optical and proton diagnostics

The results of an experiment to propagate laser-generated plasma jets into an ambient medium are presented. The jets are generated via laser irradiation of a foam-filled cone target, the results and characterization of which have been reported previously [Loupias et al., Phys. Rev. Lett. 99, 265001 (2007)] for propagation in vacuum. The introduction of an ambient medium of argon at varying density is seen to result in the formation of a shock wave, and the shock front displays perturbations that appear to grow with time. The system is diagnosed with the aid of proton radiography, imaging the perturbed structure in the dense parts of the shock with high resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Research Activities At The RCNP Cyclotron Facility

The Research Center for Nuclear Physics (RCNP) cyclotron cascade system has been operated to provide high quality beams for various experiments. In order to increase the physics research opportunities, the Azimuthally Varying Field (AVF) cyclotron facility was upgraded recently. A flat-topping system and an 18-GHz superconducting Electron Cyclotron Resonance (ECR) ion source were introduced to improve the beam's quality and intensity. A new beam line was installed to diagnose the characteristics of the beam to be injected into the ring cyclotron and to bypass the ring cyclotron and directly transport low energy beams from the AVF cyclotron to experimental halls. A separator is equipped to provide RI beams produced by fusion reactions at low energy and by projectile fragmentations at high energy. Development has continued to realize the designed performance of these systems.

43 PARTICLE ACCELERATORS↗

Benefits and Challenges of the Use of High-Z Plasma Facing Materials in Fusion Devices

The use of high-Z plasma facing components requires intensive research in all areas, i.e. in plasma wall-interaction, in the physics of the confined plasma, diagnostic, and in material development. Only a few present day divertor tokamaks - mainly Alcator C-Mod and ASDEX Upgrade - gained experience with the refractory metals molybdenum and tungsten, respectively. ASDEX Upgrade was stepwise converted from graphite to tungsten PFCs and in parallel a reduction of the deuterium retention by almost a factor of ten has been observed due to the strong suppression of D co-deposition with carbon. The deuterium retained in W is in line with laboratory results. In order to diagnose W sources and the W content in the main plasma adequate spectroscopic methods had to be developed. As expected from the sputtering threshold of Mo and W, negligible erosion by the thermal divertor background plasma is found in ASDEX Upgrade and Alcator C-Mod under low temperature divertor conditions. However, erosion by fast particles and intrinsic impurities, which additionally might be accelerated in rectified electrical fields observed during ion cyclotron frequency heating, plays an important role. The Mo and W concentrations in the plasma centre are strongly affected by plasma transport and variations up to a factor of 50 are observed for similar influxes. However, it could be demonstrated that sawteeth and turbulent transport driven by central heating can suppress central accumulation. The inward transport of high-Z ions at the edge can be efficiently reduced by 'flushing' the pedestal region caused by frequent edge instabilities. Since with metal walls the edge radiation by low-Z impurities is reduced, it has to be substituted in a pure high-Z device by artificially injected low-Z impurities in order to keep the power load at an acceptable level. Experiments at ASDEX Upgrade suggest that a regime with benign erosion and favourable confinement can be achieved. Extrapolations to ITER and DEMO are difficult since the physics of plasma transport is not yet completely understood, the particle and energy fluxes are orders of magnitude higher and the technical boundary conditions in DEMO strongly differ from those of present day devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A uniformly redundant imaging array of penumbral apertures coupled with a heuristic reconstruction for hard x-ray and neutron imaging

A coded imaging and decoding (image reconstruction) scheme was developed for diagnosing a hot and dense region emitting hard x-rays and neutrons in laser-fusion plasmas. Because the imager was a uniformly redundant array of penumbral aperture (URPA) arranged in an M-matrix, URPA leads to N times (N: the total number of apertures) enhancement of signal intensity in comparison with a single penumbral aperture. A recorded penumbral image was reconstructed by a computer-based heuristic method to reduce artifacts caused by noises contained in a penumbral image. Applicability of this technique was investigated by imaging x-rays emitted from laser-produced plasmas, demonstrating a spatial resolution of 16 {mu}m. Under the present conditions, the spatial resolution was determined dominantly by a detector resolution (10.5 {mu}m) and a signal-to-noise ratio of the obtained penumbral image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary results from the Alcator C-Mod polarimeter

A poloidally viewing far infrared polarimeter diagnostic is being developed for the Alcator C-Mod tokamak, and will be used to determine the q-profile and to study density and magnetic field fluctuations. A three-chord version of what will eventually be up to a ten-chord system has been designed and fabricated and will be installed on C-Mod before the end of the current run period. Bench tests of a single chord mock-up of this system show acceptable noise levels for the planned measurements. We will discuss the analysis and experimental techniques used to diagnose and reduce noise sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quiet periods in edge turbulence preceding the L-H transition in the National Spherical Torus Experiment

This paper describes the first observations in the National Spherical Torus Experiment (NSTX) [S. M. Kaye et al., Phys. Plasmas 8, 1977 (2001)] of ''quiet periods'' in the edge turbulence preceding the low-to-high (L-H) mode transition, as diagnosed by the gas puff imaging (GPI) diagnostic near the outer midplane separatrix. During these quiet periods the GPI D{sub {alpha}}light emission pattern was transiently similar to that seen during H-mode, i.e., with a relatively small fraction of the GPI light emission located outside the separatrix. These quiet periods had a frequency of {approx}3 kHz for at least 30 ms before the L-H transition, and were correlated with changes in the direction of the local poloidal velocity. The GPI turbulence images were also analyzed to obtain an estimate for the dimensionless poloidal shearing S=(dV{sub p}/dr)(L{sub r}/L{sub p}){tau}. The values of S were strongly modulated by the quiet periods but did not significantly vary during the {approx}30 ms preceding the L-H transition. Since neither the quiet periods nor the shear flow increased immediately preceding the L-H transition, neither of these appears to be the trigger for this transition, at least for these cases in NSTX.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualizing Iron Deposition in Multiple Sclerosis Cadaver Brains

Aim: To visualize and validate iron deposition in two cases of multiple sclerosis using rapid scanning X-Ray Fluorescence (RS-XRF) and Susceptibility Weighted Imaging (SWI). Material and Methods: Two (2) coronal cadaver brain slices from patients clinically diagnosed with multiple sclerosis underwent magnetic resonance imaging (MRI), specifically SWI to image iron content. To confirm the presence of iron deposits and the absence of zinc-rich myelin in lesions, iron and zinc were mapped using RS-XRF. Results: MS lesions were visualized using FLAIR and correlated with the absence of zinc by XRF. XRF and SWI showed that in the first MS case, there were large iron deposits proximal to the draining vein of the caudate nucleus as well as iron deposits associated with blood vessels throughout the globus pallidus. Less iron was seen in association with lesions than in the basal ganglia. The presence of larger amounts of iron correlated reasonably well between RS-XRF and SWI. In the second case, the basal ganglia appeared normal and acute perivascular iron deposition was absent. Conclusion: Perivascular iron deposition is seen in some but not all MS cases, giving credence to the use of SWI to assess iron involvement in MS pathology in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using gamma-ray emission to measure areal density of inertial confinement fusion capsules

Fusion neutrons streaming from a burning inertial confinement fusion capsule generate gamma rays via inelastic nuclear scattering in the ablator of the capsule. The intensity of gamma-ray emission is proportional to the product of the ablator areal density ({rho}R) and the yield of fusion neutrons, so by detecting the gamma rays we can infer the ablator areal density, provided we also have a measurement of the capsule's total neutron yield. In plastic-shell capsules, for example, {sup 12}C nuclei emit gamma rays at 4.44 MeV after excitation by 14.1 MeV neutrons from D+T fusion. These gamma rays can be measured by a new gamma-ray detector under development. Analysis of predicted signals is in progress, with results to date indicating that the method promises to be useful for diagnosing imploded capsules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Millimeter-wave radiometer diagnostics of harmonic electron cyclotron emission in the Levitated Dipole Experiment

A 110/137 GHz radiometer pair with collimated antenna pattern is being used to diagnose optically thin harmonic electron cyclotron emission from hot electrons in LDX. Signal levels of 0.1-1 keV and 110/137 ratios of 2-4 stationary with ECRH power have been observed. The large plasma core magnetic field gradient causes all relevant harmonics to be simultaneously viewed over a <(k,B) angular range of 0 deg. - 90 deg. representing a unique geometry for interpretation of ECE in terms of hot electron temperature and density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser generated neutron source for neutron resonance spectroscopy

A neutron source for neutron resonance spectroscopy has been developed using high-intensity, short-pulse lasers. This technique will allow robust measurement of interior ion temperature of laser-shocked materials and provide insight into material equation of state. The neutron generation technique uses laser-accelerated protons to create neutrons in LiF through (p,n) reactions. The incident proton beam has been diagnosed using radiochromic film. This distribution is used as the input for a (p,n) neutron prediction code which is validated with experimentally measured neutron yields. The calculation infers a total fluence of 1.8x10{sup 9} neutrons, which are expected to be sufficient for neutron resonance spectroscopy temperature measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion product diagnostics planned for Large Helical Device deuterium experiment

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt {gamma}-ray diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mach reflection in a warm dense plasma

The phenomenon of irregular shock-wave reflection is of importance in high-temperature gas dynamics, astrophysics, inertial-confinement fusion, and related fields of high-energy-density science. However, most experimental studies of irregular reflection have used supersonic wind tunnels or shock tubes, and few or no data are available for Mach reflection phenomena in the plasma regime. Similarly, analytic studies have often been confined to calorically perfect gases. We report the first direct observation, and numerical modeling, of Mach stem formation for a warm, dense plasma. Two ablatively driven aluminum disks launch oppositely directed, near-spherical shock waves into a cylindrical plastic block. The interaction of these shocks results in the formation of a Mach-ring shock that is diagnosed by x-ray backlighting. The data are modeled using radiation hydrocodes developed by AWE and LANL. The experiments were carried out at the University of Rochester's Omega laser [J. M. Soures, R. L. McCrory, C. P. Verdon et al., Phys. Plasmas 3, 2108 (1996)] and were inspired by modeling [A. M. Khokhlov, P. A. Hoeflich, E. S. Oran et al., Astrophys J. 524, L107 (1999)] of core-collapse supernovae that suggest that in asymmetric supernova explosion significant mass may be ejected in a Mach-ring formation launched by bipolar jets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗