Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Preliminary On-Orbit Neutron Dose Equivalent and Energy Spectrum Results from the ISS-RAD Fast Neutron Detector (FND)

The ISS-RAD instrument was activated on ISS on February 1st, 2016. Integrated in ISS-RAD, the Fast Neutron Detector (FND) performs, for the first time on ISS, routine and precise direct neutron measurements between 0.5 and 8 MeV. Preliminary results for neutron dose equivalent and neutron flux energy distributions from online/on-board algorithms and offline ground analyses will be shown, along with comparisons to simulated data and previously measured neutron spectral data. On-orbit data quality and pre-launch analysis validation results will be discussed as well.

Semones, Edward↗

Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora

The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/c charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm 0.6$% and 84.1$\pm 0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.

43 PARTICLE ACCELERATORS↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Increases in Future AR Count and Size: Overview of the ARTMIP Tier 2 CMIP5/6 Experiment

Abstract The Atmospheric River (AR) Tracking Method Intercomparison Project (ARTMIP) is a community effort to systematically assess how the uncertainties from AR detectors (ARDTs) impact our scientific understanding of ARs. This study describes the ARTMIP Tier 2 experimental design and initial results using the Coupled Model Intercomparison Project (CMIP) Phases 5 and 6 multi‐model ensembles. We show that AR statistics from a given ARDT in CMIP5/6 historical simulations compare remarkably well with the MERRA‐2 reanalysis. In CMIP5/6 future simulations, most ARDTs project a global increase in AR frequency, counts, and sizes, especially along the western coastlines of the Pacific and Atlantic oceans. We find that the choice of ARDT is the dominant contributor to the uncertainty in projected AR frequency when compared with model choice. These results imply that new projects investigating future changes in ARs should explicitly consider ARDT uncertainty as a core part of the experimental design.

54 ENVIRONMENTAL SCIENCES↗

Performance and calibration of quark/gluon-jet taggers using 140 fb -1 of pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

The identification of jets originating from quarks and gluons, often referred to as quark/gluon tagging, plays an important role in various analyses performed at the Large Hadron Collider, as Standard Model measurements and searches for new particles decaying to quarks often rely on suppressing a large gluon-induced background. This paper describes the measurement of the efficiencies of quark/gluon taggers developed within the ATLAS Collaboration, using $\sqrt{s}$ = 13 TeV proton–proton collision data with an integrated luminosity of 140 fb -1 collected by the ATLAS experiment. Two taggers with high performances in rejecting jets from gluon over jets from quarks are studied: one tagger is based on requirements on the number of inner-detector tracks associated with the jet, and the other combines several jet substructure observables using a boosted decision tree. A method is established to determine the quark/gluon fraction in data, by using quark/gluon-enriched subsamples defined by the jet pseudorapidity. Differences in tagging efficiency between data and simulation are provided for jets with transverse momentum between 500 GeV and 2 TeV and for multiple tagger working points.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of β n and spectrum of n = 1 applied fields on fast ion losses in DIII-D

Abstract The effect of n = 1 magnetic perturbations (MPs) on prompt fast ion losses in DIII-D has been investigated using the light ion beam probe technique. The effect of normalized beta, β n , and the plasma response to the MPs is studied for several MP spectra. Magnetics data show a strong dependence of plasma response to β n that depends on the phase difference in perturbation coils, Δ ϕ U L . For most phases, the response increases with β n , however, the response is suppressed for phases between 180 ∘ and 240 ∘ . Experimental data from scintillator based fast ion loss detectors shows that relative fluctuation of lost ions (20%–30% of the steady signal) does not diminish across the L- to H-mode transition for Δ ϕ U L = 240 ∘ , despite the 34% decrease in radial response field and 50% decrease in poloidal response field. Simulations of the DIII-D discharges using M3D-C1 and ASCOT5 find that prompt losses from neutral beam injection in each investigated case hit the first wall at several concentrated locations: the vessel floor, midplane diagnostic ports, vessel ceiling, and inner wall. Simulated losses from co-injection neutral beams are born outside the last closed flux surface, corresponding to radial orbit displacements of 3–6 cm due to the MPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam modeling in optical storage systems

A computer model has been developed that simulates light propagating through an optical data storage system. A model of a laser beam that originates at a laser diode, propagates through an optical system, interacts with a optical disk, reflects back from the optical disk into the system, and propagates to data and servo detectors is discussed.

Treptau, J. P.↗

Micro pulse lidar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering has been demonstrated. The transmitter of the micropulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited by optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that systems built on the micropulse lidar concept are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Micro pulse laser radar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering is disclosed. The transmitter of the micro pulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited to optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that micropulse lider systems are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Tidal Stripping of a White Dwarf by an Intermediate-mass Black Hole

During the inspiralling of a white dwarf (WD) into an intermediate-mass black hole (~10 2-5 M ⊙ ), both gravitational waves (GWs) and electromagnetic (EM) radiation are emitted. Once the eccentric orbit's pericenter radius approaches the tidal radius, the WD would be tidally stripped upon each pericenter passage. The accretion of this stripped mass would produce EM radiation. It is suspected that the recently discovered new types of transients, namely the quasiperiodic eruptions and the fast ultraluminous x-ray bursts, might originate from such systems. Modeling these flares requires a prediction of the amount of stripped mass from the WD and the details of the mass supply to the accretion disk. We run hydrodynamical simulations to study the orbital parameter dependence of the stripped mass. We find that our results match the analytical estimate that the stripped mass is proportional to z 5/2 , where z is the excess depth by which the WD overfills its instantaneous Roche lobe at the pericenter. The corresponding fallback rate of the stripped mass is calculated, which may be useful in interpreting the individual flaring light curve in candidate EM sources. We further calculate the long-term mass-loss evolution of a WD during its inspiral and the detectability of the GW and EM signals. The EM signal from the mass-loss stage can be easily detected: the limiting distance is ~320(M h /10 4 M ⊙ ) Mpc for the Einstein Probe. The GW signal, for space-borne detectors such as Laser Interferometer Space Antenna or TianQin, can be detected only within the Local Supercluster (~33 Mpc).

79 ASTRONOMY AND ASTROPHYSICS↗

Mariner Mars 1971 sun sensor model development and simulation

The sun sensor flight performance data were analyzed along with the results of a newly developed cruise sensor life in order to better understand cadmium sulfide sun sensor performance. A set of mathematical models was constructed which closely approximated the observed sun sensor flight and laboratory test results. These models revealed, among other things, that (1) the aging phenomena in the sintered cadmium sulfide light detector varies across the detector width in proportion to the illumination history, (2) the current cruise sun sensor design is extremely sensitive to changes in the reflected illumination within the sensor housing, (3) the reflected illumination within the detector housing is proportional to the area and intensity of the solar disk observed at the spacecraft, and (4) the acquisition sun sensor becomes a low impedance path across the sensor bridge when in the vicinity of a large-angular-diameter, low-intensity light source.

Schumacher, L.↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

SPARCLE: Validation of Observing System Simulations (SPace Readiness Coherent Lidar Experiment)

NASA recently approved a mission to fly a Doppler Wind Lidar (DWL) on a U.S. Space Shuttle. SPARCLE, managed by Marshall Space Flight Center in Huntsville, AL, is targeted for launch in March 2001. This mission is viewed as a necessary demonstration of a solid state (2 micron) lidar using coherent detection before committing resources to a 3-5 year research or operational mission. While, to many, this shuttle mission is seen as the first step in a series leading to a fully operational wind observing system, to others, it is a chance to validate predictions of performance based upon theoretical models, analyses of airborne and ground-based data, and sophisticated observing system simulation experiments. This paper will be presented in two parts: first a brief overview of the SPARCLE mission and second, a summary of current performance predictions and key contributions from ground- based and airborne DWL research. The SPARCLE instrument is a 100 mJ, 6 Hz, diode-pumped 2-micron laser with a .25 m telescope using heterodyne mixing in a fiber and an InGaAs detector. A 25 cm silicon wedge scanner will be used in step-stare modes with dwells ranging from 60 seconds to .5 seconds. Pointing knowledge is achieved with a dedicated GPS/INS mounted close to the lidar. NASA's Hitchhiker program is providing the instrument enclosures (2 cans) and mission logistics support. An on-board data system is sized to record 150 Gbytes of raw signal from a two 400 MHZ A/D converters. On-board signal processing will be used to control the frequency of the Local Oscillator. SPARCLE is predicted to have a single shot backscatter sensitivity near 1x10(exp -6) m-1 sr-1, To achieve higher sensitivity, shot accumulation will be employed. Ground-based, 2 micron DWLs have been used to assess the benefits of shot accumulation (approximately SQRT for SNR). Airborne programs like MACAWS have provided good datasets for evaluating various sampling strategies and signal processing algorithms. Using these real data to calibrate our simulation models, we can describe when and how well SPARCLE is expected to preform. Outputs from these performance models will be presented.

Emmitt, G. D.↗

The polarization sensitivity of GRETINA

Compton polarimeters have played an important role in the study of nuclear structure physics, but have often been limited in their applications because of relatively low -ray detection efficiency. With the advent of -ray tracking detector arrays, which feature nearly solid angle coverage and the ability to identify the location of Compton-scattering events to within a few millimeters, this limitation can be overcome. Here we present a characterization of the performance of the Gamma Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter using the 24 Mg(p,p') reaction at 2.45 MeV proton energy. We also discuss a new capability added to the simulation package UCGretina to simulate the emission of polarized photons, and compare it to the measured data. Lastly, we use these simulations to predict the performance of the Gamma Ray Energy Tracking Array (GRETA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two approaches for the optical isolation of cells: "megatiles" with grooved boundaries between cells, and a 3D-printed plastic frame hosting individual cells. Further, we found that the latter suppresses optical crosstalk to negligible levels while providing an easier assembly method. Overall, these performance studies can help inform calorimeter design and realistic simulations of 5D showers (time, energy, position) for the EIC and other experiments.

47 OTHER INSTRUMENTATION↗

Measurement of quark- and gluon-like jet fractions using jet charge in PbPb and pp collisions at 5.02 TeV

The momentum-weighted sum of the electric charges of particles inside a jet, known as jet charge, is sensitive to the electric charge of the particle initiating the parton shower. This paper presents jet charge distributions in $ \sqrt{s_{\mathrm{NN}}} $ = 5.02 TeV lead-lead (PbPb) and proton-proton (pp) collisions recorded with the CMS detector at the LHC. These data correspond to integrated luminosities of 404 μb$^{−1}$ and 27.4 pb$^{−1}$ for PbPb and pp collisions, respectively. Leveraging the sensitivity of the jet charge to fundamental differences in the electric charges of quarks and gluons, the jet charge distributions from simulated events are used as templates to extract the quark- and gluon-like jet fractions from data. The modification of these jet fractions is examined by comparing pp and PbPb data as a function of the overlap of the colliding Pb nuclei (centrality). This measurement tests the color charge dependence of jet energy loss due to interactions with the quark-gluon plasma. No significant modification between different centrality classes and with respect to pp results is observed in the extracted quark- and gluon-like jet fractions.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗